Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Saudi J Ophthalmol ; 38(1): 71-77, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38628420

RESUMEN

PURPOSE: The purpose of this study was to report visual and refractive outcomes in eyes that underwent intraocular lens (IOL) fixation in the absence of capsular support. METHODS: This was a retrospective chart review of cases undergoing posterior chamber iris-fixated IOL (IFIOL) and scleral-fixated IOL (SFIOL) implants from June 2014 to March 2020 with more than 3 months of follow-up and having a preoperative best-corrected visual acuity of 20/80 and more. RESULTS: Records of 120 eyes of 112 patients were reviewed. The mean age of the patients was 46.9 ± 22.3 (14.4-98.0) years, and 62% (n = 70) of participants were male. Most of the eyes (102: 85%) were aphakic at the time of surgery. The mean follow-up was 22.95 ± 17.1 months. The efficacy index of sutured IFIOL and glued SFIOL outperformed sutured SFIOL at 3 months and final visits postoperatively (P < 0.001). All techniques studied here resulted in a similar safety index at 3 months (P = 0.4). The mean predictive error (postoperative spherical equivalent refraction minus intended target refraction) was +0.07 ± 1.5 D and -0.12 ± 1.4 D at 3 months and the final postoperative visit, respectively. CONCLUSION: The studied techniques have relatively good visual and refractive outcomes in this series. In addition, techniques involving a small corneal incision with foldable IOL fixation to the iris or scleral tissue have superior efficacy and safety indices compared to creating large corneoscleral wounds for rigid IOL fixation techniques.

3.
Am J Case Rep ; 24: e942279, 2023 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-38051696

RESUMEN

BACKGROUND We report a case of late-onset chronic fistula in a decompensated cornea after multiple ocular surgeries and a recent phototherapeutic keratectomy (PTK). CASE REPORT A 73-year-old woman presented to our service with a past ocular history of bilateral chronic angle closure glaucoma and pseudophakic bullous keratopathy in the left eye. Given a history of long-term uncontrolled glaucoma with advanced disc cupping and poor visual potential, the patient underwent multiple palliative procedures, including, most recently, a PTK. Few years later she presented with a spontaneous late onset of slowly appearing corneal leak on fluorescein staining upon routine clinical examination. Corrected distance visual acuity was hand motion and intraocular pressure (IOP) was 40 mmHg in the affected eye. Serial anterior segment optical coherence tomography (AS-OCT) sections were obtained, which aided in understanding the current presentation and revealed distinctive multilayer corneal changes during the healing process. The patient was successfully managed with cyanoacrylate corneal gluing and ocular hypotensive medications, which halted the corneal leak. CONCLUSIONS We report a case of a rare finding of corneal fistula in an eye with multiple previous ocular surgeries, and provide an explanation of the possible etiopathogenesis. We also highlight the pivotal role of AS-OCT for evaluating such cases and stress the importance of early detection of similar subtle leaks in the setting of a formed anterior chamber, which can often be missed, carrying a risk of infection.


Asunto(s)
Córnea , Enfermedades de la Córnea , Fístula , Láseres de Excímeros , Queratectomía Fotorrefractiva , Anciano , Femenino , Humanos , Córnea/patología , Córnea/cirugía , Láseres de Excímeros/efectos adversos , Láseres de Excímeros/uso terapéutico , Queratectomía Fotorrefractiva/efectos adversos , Queratectomía Fotorrefractiva/métodos , Tomografía de Coherencia Óptica/métodos , Agudeza Visual , Fístula/diagnóstico , Fístula/etiología , Fístula/terapia , Enfermedad Crónica , Enfermedades de la Córnea/diagnóstico , Enfermedades de la Córnea/etiología , Enfermedades de la Córnea/terapia , Oftalmopatías/cirugía
4.
Am J Case Rep ; 24: e940535, 2023 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-37691282

RESUMEN

BACKGROUND The efficacy and safety of the implantable collamer lens (ICL) in correcting high astigmatism have been previously reported. They are commonly used as an alternative to laser refractive surgery due to advantages such as leaving the cornea untouched, inducing fewer higher-order aberrations, resulting in better optical and visual quality, and it is a reversible procedure. We aim to present the outcome of ICL in managing anisometropia without cataract in an eye with unilateral lenticular coloboma. CASE REPORT A 27-year-old man with a Marfanoid body habitus was seeking refractive surgery for the correction of high astigmatism in the right eye. On presentation, the best corrected visual acuity was 20/30 and 20/20 in the right eye and left eye, respectively. Slit lamp examination indicated inferior lens coloboma extending from the 5 o'clock to the 7: 30 o'clock position in the right eye, after dilation of pupil. Following a complete refractive work-up, a toric ICL implantation was the presumed suitable surgery. Three weeks postoperatively, central vaulting was low, his ICL subluxated inferiorly, and the previously implanted temporal footplates were resting over the lenticular defect inferiorly. A high-resolution ultrasound biomicroscopy confirmed the presence of a ciliary body (CB) cyst at 9 o'clock position. Urgent explantation of the unstable ICL was performed. CONCLUSIONS This case report emphasizes the challenges and limitations associated with ICL implantation in patients with lenticular colobomas and coexisting CB cyst. Selecting smaller lenticular colobomas and avoiding direct interaction between the weak zonules area and the ICL haptics are important steps to ensure the stability of implanted lens.


Asunto(s)
Astigmatismo , Coloboma , Subluxación del Cristalino , Masculino , Humanos , Adulto , Coloboma/complicaciones , Coloboma/cirugía , Prótesis e Implantes , Subluxación del Cristalino/etiología , Subluxación del Cristalino/cirugía
5.
Risk Manag Healthc Policy ; 16: 1667-1677, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37641780

RESUMEN

Purpose: Needle-stick injuries (NSI) are a prominent route by which blood-borne infections are transmitted. The unique microsurgical nature of ophthalmic practice constitutes an additional risk to sustain injury. This study aimed to identify the epidemiological profile of needle-stick injuries in a tertiary eye center and to evaluate the implemented safety policy in preventing sharp injuries. Methods: This was a retrospective cross-sectional study of all sharp injuries that occurred at King Khalid Eye Specialist Hospital (KKESH). Data on all reported sharp injury incidents from 2013 to 2021 were collected. The mechanisms of injury, context, location, and type of prick were collected and analyzed. Also, this study involved an institution-based survey for all ophthalmic staff. Results: Two hundred and one sharp injury incidents were reported over 9 years. Physicians sustained 46.8% (n=94) of injuries, followed by nurses and ophthalmic technicians, 40.8% (n=82) and 7% (14); respectively. Operating and treatment rooms were the locations of 60.7% of incidents, whereas outpatient clinics and emergency rooms accounted for 19.4% and 13.4% of injuries, respectively. Conclusion: The current findings add to the growing body of literature on the importance of NSI prevention and reporting strategies. In the present study, sharp injuries were most commonly encountered by ophthalmic staff in the operating rooms. Continuous staff education on handling sharp instruments, encouraging anonymous reporting, and up-to-date revisions of guidelines and policies are of paramount importance to lessen the burden of sharp injuries.

6.
Cancers (Basel) ; 15(14)2023 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-37509256

RESUMEN

The pivotal role of p53 in the regulation of a vast array of cellular functions has been the subject of extensive research. The biological activity of p53 is not strictly limited to cell cycle arrest but also includes the regulation of homeostasis, DNA repair, apoptosis, and senescence. Thus, mutations in the p53 gene with loss of function represent one of the major mechanisms for cancer development. As expected, due to its key role, p53 is expressed throughout the human body including the eye. Specifically, altered p53 signaling pathways have been implicated in the development of conjunctival and corneal tumors, retinoblastoma, uveal melanoma, and intraocular melanoma. As non-selective cancer chemotherapies as well as ionizing radiation can be associated with either poor efficacy or dose-limiting toxicities in the eye, reconstitution of the p53 signaling pathway currently represents an attractive target for cancer therapy. The present review discusses the role of p53 in the pathogenesis of these ocular tumors and outlines the various pharmacological activators of p53 that are currently under investigation for the treatment of ocular malignancies.

7.
Am J Case Rep ; 24: e939940, 2023 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-37386760

RESUMEN

BACKGROUND Refractive surgery is one of the most frequently performed ocular surgeries worldwide. Implantation of the posterior chamber phakic intraocular lens has advantages over laser vision correction, especially in high refractive error cases. We present a case of a young adult women with poor vision who underwent bilateral posterior chamber phakic intraocular lens explantation due to high vault, shallow anterior chambers, and a picture of cone-rod dystrophy. CASE REPORT A 23-year-old woman was referred for poor vision following an implantation of bilateral toric implantable collamer lens (ICL) implantation when she was 18 years old for high myopic astigmatism and anisometropia. On presentation, the best corrected visual acuity was 4-6/200 and 2-3/200 in the right eye and left eye, respectively. Slit lamp examination indicated a clear cornea with pigment deposition on the endothelium, high ICL vault, shallow anterior chamber, and bowing of the iris bilaterally. The patient underwent bilateral removal of the ICLs on separate visits, yet the vision remained unchanged. Diagnostics revealed that the patient had bull's eye maculopathy with atrophy due to her cone-rod dystrophy, which caused the poor vision. CONCLUSIONS This report emphasizes the need for careful and appropriate patient and intraocular size selection for refractive surgery. It indicates the importance of thorough medical examination, including genetic testing, fundus examination, and optical coherence tomography when retinal dystrophy is suspected. Generally, close follow-up is crucial in the setting of high vaulting following ICL implantation to prevent secondary complications.


Asunto(s)
Distrofias de Conos y Bastones , Lentes Intraoculares Fáquicas , Baja Visión , Femenino , Adulto Joven , Humanos , Adulto , Adolescente , Lentes Intraoculares Fáquicas/efectos adversos , Remoción de Dispositivos , Atrofia
8.
Cornea ; 42(9): 1183-1186, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-36881012

RESUMEN

PURPOSE: The purpose of this study was to report the outcomes of using gamma-irradiated sterile cornea (GISC) as a deep lamellar keratoplasty (DALK) graft in a patient with keratoconus. METHODS: This is a case report. RESULTS: A 33-year-old male patient diagnosed with keratoconus underwent DALK using a GISC and developed a persistent epithelial defect which eventually led to sterile keratolysis necessitating further surgical interventions. Management and slitlamp photography, anterior segment optical coherence tomography (AS-OCT), and histopathological examination of the explanted graft are described in detail. CONCLUSIONS: This is the first reported case of sterile keratolysis after the use of GISC lenticule in DALK in a healthy patient with keratoconus. The underlying pathophysiology is not clearly understood, and some theories have been proposed in this report. Surgeons need to be aware of this rare complication and are encouraged to have a low threshold for graft replacement to ensure good clinical and visual outcomes. Developing a prospective complication registry to document complications after the use of GISC lenticules in ophthalmic surgery is recommended.


Asunto(s)
Trasplante de Córnea , Queratocono , Masculino , Humanos , Adulto , Queratoplastia Penetrante/métodos , Agudeza Visual , Estudios Prospectivos , Resultado del Tratamiento , Estudios Retrospectivos , Trasplante de Córnea/efectos adversos , Trasplante de Córnea/métodos
9.
Am J Ophthalmol Case Rep ; 29: 101768, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36570105

RESUMEN

Purpose: to present the signs, symptoms and management of two cases of traumatic dislocation of implantable collamer lens (ICL) after direct blunt trauma. Observations: at presentation, we noted diffuse conjunctival hyperemia, and clear cornea in the right eye of the first patient. The anterior chamber showed +2 pigmented cells, a distorted, nasally peaked pupil with one-foot plate in front of the iris. The second case had a dislocation of the inferonasal footplate into the anterior chamber without endothelial touch. Conclusions and importance: Dislocation of an implantable collamer lens (ICL) is rare but carries the risk of long-term complications, particularly after trauma. Ophthalmologists should identify dislocation and timely intervention can mitigate the risk of complications.ICL dislocation can be vision threatening. Ophthalmologists should identify dislocation and timely intervention can mitigate the risk of complications.

10.
Int Ophthalmol ; 43(6): 1935-1943, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36471221

RESUMEN

PURPOSE: To assess the magnitude severity and determinants of eyestrain and the use of digital devices in a Saudi population during the COVID-19 pandemic lockdown. METHODS: This web-based survey was conducted in September 2020 and enrolled only Saudi nationals 15 years or older. Data were collected on demographics, eye strain related symptoms, severity, and the use of optical aids during the COVID-19 lockdown. The frequency and severity of eye strain were calculated. A Computer Vision Syndrome (CVS) score was graded as none/mild moderate and severe, based on the sum of 15-eye strain related signs and symptoms. Correlation analysis was performed for determinants of CVS. RESULTS: The study sample was comprised of 2009 individuals with median age of 20 years. Among those who used digital devices for more than 6 h daily, the main reasons for use were work and social purposes among 68.4%, and 61% of respondents, respectively. The prevalence of knowledge on CVS and the '20-20 rule for using digital devices' was 9.4% and 6.9, respectively. The most common symptoms of eye strain from digital device usage were headache, burning, itching, tearing, and redness of eyes. Six hours of daily usage of digital devices was positively associated to the grade of eye strain severity during the COVID-19 lockdown (P < 0.05)). CONCLUSION: The Saudi population experienced eye strain during COVID-19 lockdown due to excessive digital devices usage. Longer duration of digital device usage was associated to eye strain. Health care providers should educate the general population on measures to mitigate eye strain due to digital devices. Trial registration ID None applicable.


Asunto(s)
Astenopía , COVID-19 , Adulto , Humanos , Adulto Joven , Astenopía/epidemiología , Astenopía/etiología , Control de Enfermedades Transmisibles , COVID-19/epidemiología , Pandemias , Síndrome
11.
Risk Manag Healthc Policy ; 15: 2335-2342, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36531203

RESUMEN

Purpose: Preventive measures to mitigate the spread of coronavirus, minimized workload on health-care systems and redirected resources to COVID-19 patients resulting in a reduction of elective procedures such as cataract surgery. We report the changes in monthly cataract surgery rate and its associated determinants at a tertiary eye hospital during different periods of the pandemic. Studying the impact of COVID-19 pandemic on cataract surgery rate will help health-care policymakers to better understand the barriers to overcome the expected surgical backlog. Methods: A retrospective review of medical records was performed for cataract surgeries from November 2018 to January 2022, five thousand and ninety-two eyes that underwent cataract surgery during different phases of the COVID-19 pandemic were included. The monthly cataract surgery rate (MCSR) was calculated and compared before (Phase 1), during (Phase 2) and after the COVID-19 pandemic (Phase 3 and 4). Changes in monthly cataract surgery rate during and after the pandemic were presented as ratios and compared pre- to post-pandemic levels to evaluate the impact of different determinants. Results: Of 9701 cataract patients, 5092 (52.5%) were operated in P1, 71 (0.73%) in P2, 116 (1.2%) in P3 and 4422 (45.6%) in P4. The MCSR varied significantly based on the degree of visual impairment in the operated and fellow eyes, and by the type of operating surgeon (P < 0.05). Age, gender, laterality, and place of residence were not significantly different throughout the study period. During phase 1135 (2.6%) eyes had rupture of the posterior capsule (PCR), while 6 eyes (8.4%) had PCR in phase 2. Conclusion: The monthly cataract surgery rate declined during the pandemic and has not recovered to pre-pandemic levels. This should alert the key stakeholders to address the identified barriers to surpassing the baseline monthly surgical rate as this is crucial to eliminate the surgical backlog after the pandemic.

12.
Front Oncol ; 12: 1000677, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36338723

RESUMEN

MDM2 is the principal inhibitor of p53, and MDM2 inhibitors can disrupt the physical interaction between MDM2 and p53. The half-life of p53 is very short in normal cells and tissues, and an uncontrolled increase in p53 levels has potential harmful effects. It has been shown that p53 is frequently mutated in most cancers; however, p53 mutations are rare in retinoblastoma. Therefore, therapeutic strategies aimed at increasing the expression levels of wild-type p53 are attractive. In this minireview, we discuss the potential use of nutlin-3, the prototype small molecule inhibitor that disrupts the MDM2-p53 interaction, for the treatment of retinoblastoma. Although p53 has pleiotropic biological effects, the functions of p53 depend on its sub-cellular localization. In the nucleus, p53 induces the transcription of a vast array of genes, while in mitochondria, p53 regulates mitochondrial metabolism. This review also discusses the relative contribution of p53-mediated gene transcription and mitochondrial perturbation for retinoblastoma treatment.

13.
Saudi J Ophthalmol ; 36(2): 171-176, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36211313

RESUMEN

PURPOSE: To study the risk factors, visual outcomes, and sequelae of phacoemulsification surgery complicated by retained lens fragments (RLFs). METHODS: This single-center case-control study enrolled consecutive eyes complicated by RLF and compared them to age- and gender-matched uneventful cataract surgery cases at a tertiary care teaching hospital. Biometric, intraoperative, and postoperative data were collected. The primary outcome measures were risk factors, visual outcomes, and rate of postoperative complications. RESULTS: The study and control groups included 282 and 289 eyes, respectively. The estimated incidence of RLF was 1.47% during the study. We found a statistically higher risk of RLF among diabetics (P < 0.001), those with a history of intravitreal injections (P = 0.001), eyes with dense nuclear sclerosis, anterior capsular cataract (P < 0.001), and posterior polar cataract (P = 0.01). There was a statistically higher risk of RLF in eyes with a higher mean preoperative visual acuity (logarithm of the minimum angle of resolution) (P < 0.001) and in cases performed by trainees (P < 0.001). Most eyes in the RLF group (n = 207, 73.4%) retained their preoperative vision or experienced a one-line improvement in visual acuity and 14 eyes (5.3%) experienced more than one-line improvement in vision. CONCLUSION: Although RLFs are rare, they can affect the quality of postoperative vision and outcomes of complicated phacoemulsification surgery.

14.
Front Med (Lausanne) ; 9: 902713, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35911386

RESUMEN

Starting from the beginning of the severe acute respiratory syndrome Coronavirus-2 (SARS-CoV-2) global pandemic, most of the published data has concentrated on the respiratory signs and symptoms of Covid-19 infection, underestimating the presence and importance of ocular manifestations, such as conjunctivitis, usually reported in SARS-CoV-2 infected patients. With the present review we intend to resume the ocular involvement in SARS-CoV-2 infection and the recent discoveries about the different cell types and tissues of the eye that can be directly infected by SARS-CoV-2 and propagate the infection. Moreover, reviewing literature data about p53 expression in normal and diseased eye tissues, we hypothesize that the pleiotropic protein p53 present at high levels in cornea, conjunctiva and tear film might play a protective role against SARS-CoV-2 infection. Since p53 can be easily up-regulated by using small molecule non-genotoxic inhibitors of MDM2, we propose that topical use of Nutlin-3, the prototype member of MDM2 inhibitors, might protect the anterior surface of the eye from SARS-CoV-2 infection, reducing the spreading of the virus.

15.
Saudi J Ophthalmol ; 36(1): 47-52, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35971481

RESUMEN

PURPOSE: The purpose of the study is to compare the short-term outcomes of corneal collagen crosslinking (CXL) using the conventional (Dresden) protocol and an accelerated CXL (ACXL) protocol to stop keratoconus (KC) progression. METHODS: A chart review was performed for all the patients with KC who underwent CXL in the last 7 years. Data were compared at baseline and at all follow-up examinations for uncorrected visual acuity (UCVA), best spectacle corrected visual acuity (BCVA), keratometry (K), central corneal thickness, and complications of CXL. Pre- and post-intervention values were compared for each group. P < 0.05 was statistically significant. RESULTS: After the treatment, there was a statistically greater improvement in UCVA in the conventional CXL (CCXL) group (49%) compared to the ACXL group (34%) (P = 0.028). The improvement in BCVA was similar between the groups (P = 0.060). Gain of two lines of UCVA and stability were comparable between groups (P = 0.078 and P = 0.060, respectively). The average flat K and steep K values fluctuated remarkably across different follow-up assessments in both the groups. At 3 months of follow-up, there was a statistically significantly faster return to baseline levels of flat and steep Ks in the CCXL group (P = 0.028 and P = 0.002, respectively). CONCLUSION: The findings of the current study confirm the efficacy and safety of accelerated high-fluence CXL compared to CCXL. Both protocols were effective in stabilizing KC at 9th-month and the last follow-up visit. Larger prospective randomized controlled trials and longer follow-up are required to confirm our findings.

16.
Saudi J Ophthalmol ; 36(1): 64-69, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35971492

RESUMEN

PURPOSE: To evaluate the causes and long-term outcomes after intrastromal corneal ring segment (ICRS) explantation in the King Khaled Eye Specialist Hospital. METHODS: This was retrospective cohort study. Two groups were analyzed: Group one, ICRS surgery done in our hospital (n = 41) and group two, surgery done outside but removed in our hospital (n = 29). Causes and postoperative management after ICRS removal were analyzed. For statistical analysis, groups were analyzed into two subgroups of causes of ICRS removal: Visual disturbance versus extrusion/infection/neovascularization (NV) subgroups; and two subgroups of postoperative treatment: Corneal transplant (CT) versus Contact lens (CL)/eyeglasses subgroups. RESULTS: The most common cause of ICRS removal in group one was visual disturbance (45.2%) while in group two was extrusion (41.2%). CL is the preferable management after explantation. 76% of ICRS removal occurred during the first 4 years. In group 1, there was significant worse preimplantation visual acuity (P = 0.02) in CT subgroup versus CL/eyeglasses. CT subgroup had lower pachymetry of 437.4 µm (P = 0.04) and higher myopia of 8.05 (P = 0.03) than CL/eyeglasses subgroup. For group two, there was a significant improvement in uncorrected visual acuity in visual disturbances subgroup after explantation (P = 0.004). After explantation, visual disturbances subgroup had higher myopia -4.4 than extrusion subgroup -1.15 (P = 0.004). CONCLUSION: Seventy-six percent of ICRS removal occurred during the first 4 years. High myopia and pachymetry lower than 437 um were associated with visual disturbances and further management with corneal transplantation. High myopia was also associated with visual disturbances in surgeries done outside our hospital.

17.
Saudi J Ophthalmol ; 36(1): 1-2, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35971494
18.
Sci Rep ; 12(1): 11207, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-35778593

RESUMEN

To describe the presentation, histopathological characteristics, and management outcomes for corneal myxoma. This one-armed cohort study evaluated histologically confirmed consecutive cases of corneal myxoma. Data were evaluated on demographics, clinical presentation, management, histopathological and immunohistochemical features, and outcomes; visual acuity and corneal clarity. The study sample was comprised of 10 eyes (10 patients). The median age at presentation was 10.5 years. Five eyes had high intraocular pressure, four eyes had decreased distance visual acuity and one eye became discolored. Surgical management included penetrating keratoplasty (8 eyes), phototherapeutic keratectomy (1 eye), and evisceration because of a blind painful eye (1 eye). Postoperative best-corrected distance vision ranged from 20/20 to 20/60 (1 eye), < 20/60 to 20/200 (2 eyes), < 20/200 to 20/400 (1 eye), < 20/200 to light perception (4 eyes) and no light perception (1 eye). The histopathology of these lesions showed typical subepithelial proliferating spindle-shaped cells of mesenchymal origin within a myxoid stroma rich in glycosaminoglycan. The median duration of follow-up was 5 years. Recurrence was observed in an eye that underwent local excision. Corneal myxoma is a rare lesion that is presumably isolated, secondary, and reactive in nature. Surgically management yields reasonably favorable outcomes.


Asunto(s)
Mixoma , Queratectomía Fotorrefractiva , Ceguera , Estudios de Cohortes , Estudios de Seguimiento , Humanos , Láseres de Excímeros/uso terapéutico , Mixoma/diagnóstico , Mixoma/cirugía
19.
Cureus ; 14(4): e23837, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35530924

RESUMEN

Background In this study, we aimed to assess ophthalmologists' experience with teleophthalmology during the coronavirus disease 2019 (COVID-19) pandemic in the central region of Saudi Arabia. In addition, we evaluated their satisfaction level and explored their satisfaction determinants. Methodology We conducted an online survey for ophthalmologists who participated in the virtual ophthalmology clinic during COVID-19 between November 2020 and September 2021. The survey was used to evaluate ophthalmologists' experience with teleophthalmology during the pandemic. Ophthalmologists were asked to measure their satisfaction with equipment and technical issues, communication, and clinical assessment, and to provide an overall program evaluation. Data were analyzed via frequency measures (e.g., numbers, percentages, mean, and standard deviation). Results Out of the 113 ophthalmologists who were invited to participate in our study, 71 completed the survey. In total, 23 (32.4%) participants were general ophthalmologists, 15 (21.1%) were subspecialists in the cornea, 16 (22.5%) were subspecialists in glaucoma, one (1.4%) was a subspecialist in neuro-ophthalmology, seven (9.9%) were subspecialists in pediatric ophthalmology, eight (11.3%) were subspecialists in the retina, and one (1.4%) participant was a subspecialist in oculoplastic. Overall, 56.3% of the respondents were satisfied with teleophthalmology. Ophthalmologists who subspecialized in the retina demonstrated higher levels of satisfaction than other subspecialties. The most common challenge reported by ophthalmologists in the virtual consultation was the lack of adequate equipment to evaluate the patients (53.5%), followed by technical issues (43.7%) and the patients' lack of experience in using virtual consultation services (38%). Overall satisfaction score was the highest among ophthalmologists who reported providing at least five video consultations before the survey. Conclusions The findings from our study suggest that the subspeciality of ophthalmologists and the number of video consultations conducted by ophthalmologists are important determinants in their level of satisfaction with teleophthalmology. The majority of the respondents were satisfied with the virtual clinic during the COVID-19 pandemic. The current pandemic could pave the way for the future use of telemedicine in ophthalmology if virtual eye examinations become standardized.

20.
Clin Ophthalmol ; 16: 369-374, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35177895

RESUMEN

Type I Boston keratoprosthesis is implanted in patients with severely diseased eyes who are considered poor candidates for traditional keratoplasty. Glaucoma is considered a major visual comorbidity following the implantation of type I Boston keratoprosthesis (KPro). Eyes that receive a Boston KPro are at high risk of progression of pre-existing glaucoma and the development of de novo glaucoma. Both complications can limit best-corrected visual acuity postoperatively. Diagnosis and surveillance for glaucoma in KPro eyes are fundamental to mitigate the risk of visual morbidity. However, managing these patients presents several challenges. The diagnosis of glaucoma after KPro implantation is usually hindered by inaccurate intraocular pressure (IOP) measurements and unreliable ophthalmic investigations such as visual field testing and optical coherence tomography (OCT) of the retinal nerve fiber layer (RNFL). In these eyes, medical management of glaucoma with topical medications is usually insufficient, and glaucoma surgery is usually warranted either prior to or during KPro implantation. Options for glaucoma surgery include glaucoma drainage device (GDD) and cyclodestructive procedures. The aim of this article is to highlight the incidence, pathophysiology, diagnosis, and management options of glaucoma in eyes that have undergone type I Boston keratoprosthesis.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA