Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38888577

RESUMEN

Open surgical repair, often in the form of endarterectomy, is still the gold standard for steno-occlusive disease in the common femoral artery, despite the success of lower-risk endovascular alternatives in other peripheral arterial regions. Stenting in the common femoral artery is not widely adopted due to the proximity of the artery to the mobile hip joint, and the perceived risk this has on the stent structure due to kinking. The purpose of this review was to assess how hip movement contributes to the anatomical and biomechanical challenges proposed in the common femoral artery, and how these challenges impact the hemodynamics with both open surgical and endovascular stent treatments. The findings demonstrated that the common femoral artery is a fixed arterial segment which does not bend or twist as previously perceived. However, high degrees of bending and twisting are evident in the vessels directly proximal and distal to the common femoral artery. Mechanical testing suggests that the latest generation braided Nitinol stents could be well-suited to these challenges. Both endarterectomy and stenting provide good hemodynamic results regarding limb perfusion. However, other hemodynamic parameters, such as wall shear stress, may not be optimized with either modality, increasing the risk of chronic restenosis. As a high proportion of common femoral artery disease extends into the adjacent arterial segments, further research is warranted to ascertain the optimum hemodynamic stent configuration, as a lower-risk alternative to open surgery.

2.
Physiol Meas ; 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38838703

RESUMEN

Vascular ageing is the deterioration of arterial structure and function which occurs naturally with age, and which can be accelerated with disease. Measurements of vascular ageing are emerging as markers of cardiovascular risk, with potential applications in disease diagnosis and prognosis, and for guiding treatments. However, vascular ageing is not yet routinely assessed in clinical practice. A key step towards this is the development of technologies to assess vascular ageing. In this Roadmap, experts discuss several aspects of this process, including: measurement technologies; the development pipeline; clinical applications; and future research directions. The Roadmap summarises the state of the art, outlines the major challenges to overcome, and identifies potential future research directions to address these challenges.

3.
Heliyon ; 10(9): e30404, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38742066

RESUMEN

The Fontan circulation, designed for managing patients with a single functional ventricle, presents challenges in long-term outcomes. Computational methods offer potential solutions, yet their application in cardiology practice remains largely unexplored. Our aim was to assess the ability of a patient-specific, closed-loop, reduced-order blood flow model to simulate pulsatile blood flow in the Fontan circulation. Using one-dimensional models, we simulated the aorta, superior and inferior venae cavae, and right and left pulmonary arteries, while lumping heart chambers and remaining vessels into zero-dimensional models. The model was calibrated with patient-specific haemodynamic data from combined cardiac catheterisation and magnetic resonance exams, using a novel physics-based stepwise methodology involving simpler open-loop models. Testing on a 10-year-old, anesthetised patient, demonstrated the model's capability to replicate pulsatile pressure and flow in the larger vessels and ventricular pressure. Average relative errors in mean pressure and flow were 2.9 % and 3.6 %, with average relative point-to-point errors (RPPE) in pressure and flow at 5.2 % and 16.0 %. Comparing simulation results to measurements, mean aortic pressure and flow values were 50.7 vs. 50.4 mmHg and 41.6 vs. 41.9 ml/s, respectively, while ventricular pressure values were 28.7 vs. 27.4 mmHg. The model accurately described time-varying ventricular volume with a RPPE of 2.9 %, with mean, minimum, and maximum ventricular volume values for simulation results vs. measurements at 59.2 vs. 58.2 ml, 38.0 vs. 37.6 ml, and 76.0 vs. 74.4 ml, respectively. It provided physiologically realistic predictions of haemodynamic changes from pulmonary vasodilation and atrial fenestration opening. The new model and calibration methodology are freely available, offering a platform to virtually investigate the Fontan circulation's response to clinical interventions and explore potential mechanisms of Fontan failure. Future efforts will concentrate on broadening the model's applicability to a wider range of patient populations and clinical scenarios, as well as testing its effectiveness.

4.
Expert Rev Med Devices ; 21(4): 335-347, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38557297

RESUMEN

BACKGROUND: Regulation has a key role for medical devices throughout their lifecycle aiming to guarantee effectiveness and safety for users. Requirements of Regulation (EU) 2017/745 (MDR) have an impact on novel and previously approved systems. Identification of key stakeholders' needs can support effective implementation of MDR improving the translation to clinical practice of vascular ageing assessment. The aim of this work is to explore knowledge and perception of medical device regulatory framework in vascular ageing field. RESEARCH DESIGN AND METHODS: A survey was developed within VascAgeNet and distributed in the community by means of the EUSurvey platform. RESULTS: Results were derived from 94 participants (27% clinicians, 62% researchers, 11% companies) and evidenced mostly a fair knowledge of MDR (despite self-judged as poor by 51%). Safety (83%), validation (56%), risk management (50%) were considered relevant and associated with the regulatory process. Structured support and regulatory procedures connected with medical devices in daily practice at the institutional level are lacking (only 33% report availability of a regulatory department). CONCLUSIONS: Regulation was recognized relevant by the VascAgeNet community and specific support and training in medical device regulatory science was considered important. A direct link with the regulatory sector is not yet easily available.

5.
Comput Methods Programs Biomed ; 247: 108082, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38422893

RESUMEN

BACKGROUND AND OBJECTIVE: Aortic blood pressure (ABP) is a more effective prognostic indicator of cardiovascular disease than peripheral blood pressure. A highly accurate algorithm for non-invasively deriving the ABP wave, based on ultrasonic measurement of aortic flow combined with peripheral pulse wave measurements, has been proposed elsewhere. However, it has remained at the proof-of-concept stage because it requires a priori knowledge of the ABP waveform to calculate aortic pulse wave velocity (PWV). The objective of this study is to transform this proof-of-concept algorithm into a clinically feasible technique. METHODS: We used the Bramwell-Hill equation to non-invasively calculate aortic PWV which was then used to reconstruct the ABP waveform from non-invasively determined aortic blood flow velocity, aortic diameter, and radial pressure. The two aortic variables were acquired by an ultrasound system from 90 subjects, followed by recordings of radial pressure using a SphygmoCor device. The ABPs estimated by the new algorithm were compared with reference values obtained by cardiac catheterization (invasive validation, 8 subjects aged 62.3 ± 12.7 years) and a SphygmoCor device (non-invasive validation, 82 subjects aged 45.0 ± 17.8 years). RESULTS: In the invasive comparison, there was good agreement between the estimated and directly measured pressures: the mean error in systolic blood pressure (SBP) was 1.4 ± 0.8 mmHg; diastolic blood pressure (DBP), 0.9 ± 0.8 mmHg; mean blood pressure (MBP), 1.8 ± 1.2 mmHg and pulse pressure (PP), 1.4 ± 1.1 mmHg. In the non-invasive comparison, the estimated and directly measured pressures also agreed well: the errors being: SBP, 2.0 ± 1.4 mmHg; DBP, 0.8 ± 0.1 mmHg; MBP, 0.1 ± 0.1 mmHg and PP, 2.3 ± 1.6 mmHg. The significance of the differences in mean errors between calculated and reference values for SBP, DBP, MBP and PP were assessed by paired t-tests. The agreement between the reference methods and those obtained by applying the new approach was also expressed by correlation and Bland-Altman plots. CONCLUSION: The new method proposed here can accurately estimate ABP, allowing this important variable to be obtained non-invasively, using standard, well validated measurement techniques. It thus has the potential to relocate ABP estimation from a research environment to more routine use in the cardiac clinic. SHORT ABSTRACT: A highly accurate algorithm for non-invasively deriving the ABP wave has been proposed elsewhere. However, it has remained at the proof-of-concept stage because it requires a priori knowledge of the ABP waveform to calculate aortic pulse wave velocity (PWV). This study aims to transform this proof-of-concept algorithm into a clinically feasible technique. We used the Bramwell-Hill equation to non-invasively calculate aortic PWV which was then used to reconstruct the ABP waveform. The ABPs estimated by the new algorithm were compared with reference values obtained by cardiac catheterization or a SphygmoCor device. The results showed that there was good agreement between the estimated and directly measured pressures. The new method proposed can accurately estimate ABP, allowing this important variable to be obtained non-invasively, using standard, well validated measurement techniques. It thus has the potential to relocate ABP estimation from a research environment to more routine use in the cardiac clinic.


Asunto(s)
Presión Arterial , Análisis de la Onda del Pulso , Humanos , Presión Arterial/fisiología , Presión Sanguínea/fisiología , Determinación de la Presión Sanguínea , Manometría
6.
JRSM Cardiovasc Dis ; 13: 20480040231225384, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38314325

RESUMEN

Introduction: Photoplethysmogram signals from wearable devices typically measure heart rate and blood oxygen saturation, but contain a wealth of additional information about the cardiovascular system. In this study, we compared two signal-processing techniques: fiducial point analysis and Symmetric Projection Attractor Reconstruction, on their ability to extract new cardiovascular information from a photoplethysmogram signal. The aim was to identify fiducial point analysis and Symmetric Projection Attractor Reconstruction indices that could classify photoplethysmogram signals, according to age, sex and physical activity. Methods: Three datasets were used: an in-silico dataset of simulated photoplethysmogram waves for healthy male participants (25-75 years old); an in-vivo dataset containing 10-min photoplethysmogram recordings from 57 healthy subjects at rest (18-39 or > 70 years old; 53% female); and an in-vivo dataset containing photoplethysmogram recordings collected for 4 weeks from a single subject, in daily life. The best-performing indices from the in-silico study (5/48 fiducial point analysis and 6/49 Symmetric Projection Attractor Reconstruction) were applied to the in-vivo datasets. Results: Key fiducial point analysis and Symmetric Projection Attractor Reconstruction indices, which showed the greatest differences between groups, were found to be consistent across datasets. These indices were related to systolic augmentation, diastolic peak positioning and prominence, and waveform variability. Both fiducial point analysis and Symmetric Projection Attractor Reconstruction techniques provided indices that supported the classification of age and physical activity, but not sex. Conclusions: Both fiducial point analysis and Symmetric Projection Attractor Reconstruction techniques demonstrated utility in identifying cardiovascular differences between individuals and within an individual over time. Future research should investigate the potential utility of these techniques for extracting information on fitness and disease, to support healthcare-decision making.

7.
Am J Physiol Heart Circ Physiol ; 325(6): H1290-H1303, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37737734

RESUMEN

Vascular aging (VA) involves structural and functional changes in blood vessels that contribute to cardiovascular disease. Several noninvasive pulse wave (PW) indices have been proposed to assess the arterial stiffness component of VA in the clinic and daily life. This study investigated 19 of these indices, identified in recent review articles on VA, by using a database comprising 3,837 virtual healthy subjects aged 25-75 yr, each with unique PW signals simulated under various levels of artificial noise to mimic real measurement errors. For each subject, VA indices were calculated from filtered PW signals and compared with the precise theoretical value of aortic Young's modulus (EAo). In silico PW indices showed age-related changes that align with in vivo population studies. The cardio-ankle vascular index (CAVI) and all pulse wave velocity (PWV) indices showed strong linear correlations with EAo (Pearson's rp > 0.95). Carotid distensibility showed a strong negative nonlinear correlation (Spearman's rs < -0.99). CAVI and distensibility exhibited greater resilience to noise compared with PWV indices. Blood pressure-related indices and photoplethysmography (PPG)-based indices showed weaker correlations with EAo (rp and rs < 0.89, |rp| and |rs| < 0.84, respectively). Overall, blood pressure-related indices were confounded by more cardiovascular properties (heart rate, stroke volume, duration of systole, large artery diameter, and/or peripheral vascular resistance) compared with other studied indices, and PPG-based indices were most affected by noise. In conclusion, carotid-femoral PWV, CAVI and carotid distensibility emerged as the superior clinical VA indicators, with a strong EAo correlation and noise resilience. PPG-based indices showed potential for daily VA monitoring under minimized noise disturbances.NEW & NOTEWORTHY For the first time, 19 noninvasive pulse wave indices for assessing vascular aging were examined together in a single database of nearly 4,000 subjects aged 25-75 yr. The dataset contained precise values of the aortic Young's modulus and other hemodynamic measures for each subject, which enabled us to test each index's ability to measure changes in aortic stiffness while accounting for confounding factors and measurement errors. The study provides freely available tools for analyzing these and additional indices.


Asunto(s)
Análisis de la Onda del Pulso , Rigidez Vascular , Humanos , Envejecimiento/fisiología , Hemodinámica , Aorta , Arterias Carótidas , Rigidez Vascular/fisiología
8.
Front Cardiovasc Med ; 10: 1197842, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37424904

RESUMEN

Background: Arterial stiffening and peripheral wave reflections have been considered the major determinants of raised pulse pressure (PP) and isolated systolic hypertension, but the importance of cardiac contractility and ventricular ejection dynamics is also recognised. Methods: We examined the contributions of arterial compliance and ventricular contractility to variations in aortic flow and increased central (cPP) and peripheral (pPP) pulse pressure, and PP amplification (PPa) in normotensive subjects during pharmacological modulation of physiology, in hypertensive subjects, and in silico using a cardiovascular model accounting for ventricular-aortic coupling. Reflections at the aortic root and from downstream vessels were quantified using emission and reflection coefficients, respectively. Results: cPP was strongly associated with contractility and compliance, whereas pPP and PPa were strongly associated with contractility. Increased contractility by inotropic stimulation increased peak aortic flow (323.9 ± 52.8 vs. 389.1 ± 65.1 ml/s), and the rate of increase (3193.6 ± 793.0 vs. 4848.3 ± 450.4 ml/s2) in aortic flow, leading to larger cPP (36.1 ± 8.8 vs. 59.0 ± 10.8 mmHg), pPP (56.9 ± 13.1 vs. 93.0 ± 17.0 mmHg) and PPa (20.8 ± 4.8 vs. 34.0 ± 7.3 mmHg). Increased compliance by vasodilation decreased cPP (62.2 ± 20.2 vs. 45.2 ± 17.8 mmHg) without altering dP/dt, pPP or PPa. The emission coefficient changed with increasing cPP, but the reflection coefficient did not. These results agreed with in silico data obtained by independently changing contractility/compliance over the range observed in vivo. Conclusions: Ventricular contractility plays a key role in raising and amplifying PP, by altering aortic flow wave morphology.

9.
Comput Methods Programs Biomed ; 240: 107628, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37336151

RESUMEN

BACKGROUND AND OBJECTIVE: The blood pressure and flow waveforms carry valuable information about the condition of the cardiovascular system and a patient's health. Waveform analysis in health and pathological conditions can be performed in the time or frequency domains; the information to be emphasised defines the use of either domain. However, physicians are more familiar with the time domain, and the changes in the waveforms due to cardiovascular diseases and ageing are better characterised in such domain. On the other hand, the analysis of the vascular and geometrical variables determining the signatures in the frequency response of local vascular anomalies, such as aneurysms and stenoses, has not been thoroughly explored. This paper aims to characterise the signatures of obstructions (stenoses) and expansions (aneurysms) in the frequency response of tapered arteries. METHODS: The first step in our methodology was to incorporate the viscous response of the arterial wall into a one-dimensional elastic formulation that solves the governing equations in the frequency domain. As a second step, we imposed a volumetric flow excitation in arteries simulating the aorta with increasing geometry complexity: from straight to tapered arteries with local expansions or obstructions; and we assessed the frequency response. RESULTS: We found that the obstructions and expansions cause characteristic signatures in an artery's frequency response that are distinguishable from a health condition. The signatures of obstruction and expansions differ; the obstructions increase the magnitude of fundamental frequency and work as a close boundary condition. On the other hand, the expansions diminish the fundamental frequency and work as an open boundary condition. Furthermore, such signatures correlate to the distance between the artery's inlet and the anomaly's starting point and have the potential to pinpoint abnormalities non-invasively. CONCLUSIONS: We found that the obstructions and expansions cause characteristic signatures in an artery's frequency response that have the potential to detect and follow up on the development of vascular abnormalities. For the latter purpose, constant monitoring may be required; despite this not being a common clinical practice, the new wearable technology offers the possibility of continuous monitoring of biophysical markers such as the pressure waveform.


Asunto(s)
Enfermedades Vasculares , Constricción Patológica , Humanos , Arterias
10.
J Am Heart Assoc ; 12(10): e027414, 2023 05 16.
Artículo en Inglés | MEDLINE | ID: mdl-37183857

RESUMEN

Magnetic resonance imaging and computed tomography allow the characterization of arterial state and function with high confidence and thus play a key role in the understanding of arterial aging and its translation into the clinic. Decades of research into the development of innovative imaging sequences and image analysis techniques have led to the identification of a large number of potential biomarkers, some bringing improvement in basic science, others in clinical practice. Nonetheless, the complexity of some of these biomarkers and the image analysis techniques required for their computation hamper their widespread use. In this narrative review, current biomarkers related to aging of the aorta, their founding principles, the sequence, and postprocessing required, and their predictive values for cardiovascular events are summarized. For each biomarker a summary of reference values and reproducibility studies and limitations is provided. The present review, developed in the COST Action VascAgeNet, aims to guide clinicians and technical researchers in the critical understanding of the possibilities offered by these advanced imaging modalities for studying the state and function of the aorta, and their possible clinically relevant relationships with aging.


Asunto(s)
Arterias , Imagen por Resonancia Magnética , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos , Biomarcadores
11.
J Ultrasound Med ; 42(10): 2183-2213, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37148467

RESUMEN

Non-invasive ultrasound (US) imaging enables the assessment of the properties of superficial blood vessels. Various modes can be used for vascular characteristics analysis, ranging from radiofrequency (RF) data, Doppler- and standard B/M-mode imaging, to more recent ultra-high frequency and ultrafast techniques. The aim of the present work was to provide an overview of the current state-of-the-art non-invasive US technologies and corresponding vascular ageing characteristics from a technological perspective. Following an introduction about the basic concepts of the US technique, the characteristics considered in this review are clustered into: 1) vessel wall structure; 2) dynamic elastic properties, and 3) reactive vessel properties. The overview shows that ultrasound is a versatile, non-invasive, and safe imaging technique that can be adopted for obtaining information about function, structure, and reactivity in superficial arteries. The most suitable setting for a specific application must be selected according to spatial and temporal resolution requirements. The usefulness of standardization in the validation process and performance metric adoption emerges. Computer-based techniques should always be preferred to manual measures, as long as the algorithms and learning procedures are transparent and well described, and the performance leads to better results. Identification of a minimal clinically important difference is a crucial point for drawing conclusions regarding robustness of the techniques and for the translation into practice of any biomarker.


Asunto(s)
Arterias , Ultrasonografía Doppler , Humanos , Ultrasonografía/métodos , Arterias/diagnóstico por imagen , Algoritmos , Tecnología
12.
IEEE J Biomed Health Inform ; 27(7): 3622-3632, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37079413

RESUMEN

A novel temporal convolutional network (TCN) model is utilized to reconstruct the central aortic blood pressure (aBP) waveform from the radial blood pressure waveform. The method does not need manual feature extraction as traditional transfer function approaches. The data acquired by the SphygmoCor CVMS device in 1,032 participants as a measured database and a public database of 4,374 virtual healthy subjects were used to compare the accuracy and computational cost of the TCN model with the published convolutional neural network and bi-directional long short-term memory (CNN-BiLSTM) model. The TCN model was compared with CNN-BiLSTM in the root mean square error (RMSE). The TCN model generally outperformed the existing CNN-BiLSTM model in terms of accuracy and computational cost. For the measured and public databases, the RMSE of the waveform using the TCN model was 0.55 ± 0.40 mmHg and 0.84 ± 0.29 mmHg, respectively. The training time of the TCN model was 9.63 min and 25.51 min for the entire training set; the average test time was around 1.79 ms and 8.58 ms per test pulse signal from the measured and public databases, respectively. The TCN model is accurate and fast for processing long input signals, and provides a novel method for measuring the aBP waveform. This method may contribute to the early monitoring and prevention of cardiovascular disease.


Asunto(s)
Presión Arterial , Determinación de la Presión Sanguínea , Humanos , Determinación de la Presión Sanguínea/métodos , Presión Sanguínea/fisiología , Redes Neurales de la Computación , Frecuencia Cardíaca
13.
Am J Physiol Heart Circ Physiol ; 325(1): H1-H29, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-37000606

RESUMEN

Arterial pulse waves (PWs) such as blood pressure and photoplethysmogram (PPG) signals contain a wealth of information on the cardiovascular (CV) system that can be exploited to assess vascular age and identify individuals at elevated CV risk. We review the possibilities, limitations, complementarity, and differences of reduced-order, biophysical models of arterial PW propagation, as well as theoretical and empirical methods for analyzing PW signals and extracting clinically relevant information for vascular age assessment. We provide detailed mathematical derivations of these models and theoretical methods, showing how they are related to each other. Finally, we outline directions for future research to realize the potential of modeling and analysis of PW signals for accurate assessment of vascular age in both the clinic and in daily life.


Asunto(s)
Arterias , Fotopletismografía , Humanos , Arterias/fisiología , Fotopletismografía/métodos , Análisis de la Onda del Pulso , Modelos Cardiovasculares
14.
Eur J Prev Cardiol ; 30(11): 1101-1117, 2023 08 21.
Artículo en Inglés | MEDLINE | ID: mdl-36738307

RESUMEN

Prevention of cardiovascular disease (CVD) remains one of the largest public health challenges of our time. Identifying individuals at increased cardiovascular risk at an asymptomatic, sub-clinical stage is of paramount importance for minimizing disease progression as well as the substantial health and economic burden associated with overt CVD. Vascular ageing (VA) involves the deterioration in vascular structure and function over time and ultimately leads to damage in the heart, brain, kidney, and other organs. Vascular ageing encompasses the cumulative effect of all cardiovascular risk factors on the arterial wall over the life course and thus may help identify those at elevated cardiovascular risk, early in disease development. Although the concept of VA is gaining interest clinically, it is seldom measured in routine clinical practice due to lack of consensus on how to characterize VA as physiological vs. pathological and various practical issues. In this state-of-the-art review and as a network of scientists, clinicians, engineers, and industry partners with expertise in VA, we address six questions related to VA in an attempt to increase knowledge among the broader medical community and move the routine measurement of VA a little closer from bench towards bedside.


Asunto(s)
Enfermedades Cardiovasculares , Humanos , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/epidemiología , Enfermedades Cardiovasculares/prevención & control , Arterias , Envejecimiento
15.
Comput Biol Med ; 155: 106654, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36791548

RESUMEN

BACKGROUND AND OBJECTIVE: The aortic pressure waveform (APW) provides reliable information for the diagnosis of cardiovascular disease. APW is often measured using a generalized transfer function (GTF) applied to the peripheral pressure waveform acquired noninvasively, to avoid the significant risks of invasive APW acquisition. However, the GTF ignores various physiological conditions, which affects the accuracy of the estimated APW. To solve this problem, this study utilized an adaptive transfer function (ATF) combined with a tube-load model to achieve personalized and accurate estimation of APW from the brachial pressure waveform (BPW). METHODS: The proposed method was validated using APWs and BPWs from 34 patients. The ATF was defined using a tube-load model in which pulse transit time and reflection coefficients were determined from, respectively, the diastolic-exponential-pressure-decay of the APW and a piece-wise constant approximation. The root-mean-square-error of overall morphology, mean absolute errors of common hemodynamic indices (systolic blood pressure, diastolic blood pressure and pulse pressure) were used to evaluate the ATF. RESULTS: The proposed ATF performed better in estimating diastolic blood pressure and pulse pressure (1.63 versus 1.94 mmHg, and 2.37 versus 3.10 mmHg, respectively, both P < 0.10), and produced similar errors in overall morphology and systolic blood pressure (3.91 versus 4.24 mmHg, and 2.83 versus 2.91 mmHg, respectively, both P > 0.10) compared to GTF. CONCLUSION: Unlike the GTF which uses fixed parameters trained on existing clinical datasets, the proposed method can achieve personalized estimation of APW. Hence, it provides accurate pulsatile hemodynamic measures for the evaluation of cardiovascular function.


Asunto(s)
Aorta , Presión Arterial , Humanos , Presión Sanguínea/fisiología , Determinación de la Presión Sanguínea/métodos , Hemodinámica
17.
Comput Methods Programs Biomed ; 227: 107213, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36356386

RESUMEN

BACKGROUND AND OBJECTIVE: This paper proposes a novel strategy to localize anomalies in the arterial network based on its response to controlled transient waves. The idea is borrowed from system identification theories in which wave reflections can render significant information about a target system. Cardiovascular system studies often focus on the waves originating from the heart pulsations, which are of low bandwidth and, hence, can hardly carry information about the arteries with the desired resolution. METHODS: Our strategy uses a relatively higher bandwidth transient signal to characterize healthy and unhealthy arterial networks through a frequency response function (FRF). We tested our novel approach on data simulated using a one-dimensional cardiovascular model that produced pulse waves in the larger arteries of the arterial network. Specifically, we excited the blood flow from the brachial artery with a relatively high bandwidth flow disturbance and collected the subsequent pressure waveform at peripheral positions. To better differentiate FRFs of healthy and unhealthy networks, we used a FRF that removes the effects of heart pulsations. RESULTS: Results demonstrate the ability of the proposed FRF to detect and follow-up on the development of a common carotid artery (CCA) stenosis. We tested distinct geometrical variations of the stenosis (size, length and position) and observed differences between the FRFs of healthy and unhealthy networks in all cases; such differences were mainly due to geometrical variations determined by the stenosis. CONCLUSIONS: We have provided a theoretical proof of concept that demonstrates the ability of our novel strategy to detect and track the development of CCA stenosis by using peripheral pressure waves that can be measured non-invasively in clinical practice.


Asunto(s)
Estenosis Carotídea , Humanos , Constricción Patológica , Arteria Braquial/diagnóstico por imagen , Arteria Braquial/fisiología , Modelos Cardiovasculares , Simulación por Computador , Presión Sanguínea/fisiología , Arterias Carótidas/diagnóstico por imagen , Arterias Carótidas/fisiología
18.
Int J Numer Method Biomed Eng ; 38(12): e3658, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36286406

RESUMEN

This study investigated the effects of cardiac properties variability on arterial pulse wave morphology using blood flow modelling and pulse wave analysis. A lumped-parameter model of the left part of the heart was coupled to a one-dimensional model of the arterial network and validated using reference pulse waveforms in turn verified by comparison with in vivo measurements. A sensitivity analysis was performed to assess the effects of variations in cardiac parameters on central and peripheral pulse waveforms. Results showed that left ventricle contractility, stroke volume, cardiac cycle duration, and heart valves impairment are determinants of central waveforms morphology, pulse pressure and its amplification. Contractility of the left atrium has negligible effects on arterial pulse waves. Results also suggested that it might be possible to infer left ventricular dysfunction by analysing the timing of the dicrotic notch and cardiac function by analysing PPG signals. This study has identified cardiac properties that may be extracted from in vivo central and peripheral pulse waves to assess cardiac function.


Asunto(s)
Hemodinámica , Análisis de la Onda del Pulso , Presión Sanguínea/fisiología , Corazón , Volumen Sistólico
19.
Comput Mech ; 70(4): 703-722, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36124206

RESUMEN

A key factor governing the mechanical performance of the heart is the bidirectional coupling with the vascular system, where alterations in vascular properties modulate the pulsatile load imposed on the heart. Current models of cardiac electromechanics (EM) use simplified 0D representations of the vascular system when coupling to anatomically accurate 3D EM models is considered. However, these ignore important effects related to pulse wave transmission. Accounting for these effects requires 1D models, but a 3D-1D coupling remains challenging. In this work, we propose a novel, stable strategy to couple a 3D cardiac EM model to a 1D model of blood flow in the largest systemic arteries. For the first time, a personalised coupled 3D-1D model of left ventricle and arterial system is built and used in numerical benchmarks to demonstrate robustness and accuracy of our scheme over a range of time steps. Validation of the coupled model is performed by investigating the coupled system's physiological response to variations in the arterial system affecting pulse wave propagation, comprising aortic stiffening, aortic stenosis or bifurcations causing wave reflections. Our first 3D-1D coupled model is shown to be efficient and robust, with negligible additional computational costs compared to 3D-0D models. We further demonstrate that the calibrated 3D-1D model produces simulated data that match with clinical data under baseline conditions, and that known physiological responses to alterations in vascular resistance and stiffness are correctly replicated. Thus, using our coupled 3D-1D model will be beneficial in modelling studies investigating wave propagation phenomena.

20.
Comput Methods Programs Biomed ; 219: 106781, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35378395

RESUMEN

BACKGROUND AND OBJECTIVE: Arterial stiffness, commonly assessed by carotid-femoral pulse wave velocity (cfPWV), is an independent biomarker for cardiovascular disease. The measurement of cfPWV, however, has been considered impractical for routine clinical application. Pulse wave analysis using a single pulse wave measurement in the radial artery is a convenient alternative. This study aims to identify pulse wave features for a more accurate estimation of cfPWV from a single radial pulse wave measurement. METHODS: From a dataset of 140 subjects, cfPWV was measured and the radial pulse waveform was recorded for 30 s twice in succession. Features were extracted from the waveforms in the time and frequency domains, as well as by wave separation analysis. All-possible regressions with bootstrapping, McHenry's select algorithm, and support vector regression were applied to compute models for cfPWV estimation. RESULTS: The correlation coefficients between the measured and estimated cfPWV were r = 0.81, r = 0.81, and r = 0.8 for all-possible regressions, McHenry's select algorithm, and support vector regression, respectively. The features selected by all-possible regressions are physiologically interpretable. In particular, the amplitude ratio of the diastolic peak to the notch of the radial pulse waveform (Rn,dr,P) is shown to be correlated with cfPWV. This correlation was further evaluated and found to be independent of wave reflections using a dataset (n = 3,325) of simulated pulse waves. CONCLUSIONS: The proposed method may serve as a convenient surrogate for the measurement of cfPWV. Rn,dr,P is associated with aortic pulse wave velocity and this association may not be dependent on wave reflection.


Asunto(s)
Análisis de la Onda del Pulso , Arteria Radial , Presión Sanguínea , Arterias Carótidas/fisiología , Velocidad de la Onda del Pulso Carotídeo-Femoral , Humanos , Análisis de la Onda del Pulso/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA