Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
J Clin Microbiol ; 61(10): e0026423, 2023 10 24.
Artículo en Inglés | MEDLINE | ID: mdl-37724874

RESUMEN

The current four-symptom screen recommended by the World Health Organization (WHO) is widely used as screen to initiate diagnostic testing for active pulmonary tuberculosis (TB), yet the performance is poor especially when TB prevalence is low. In contrast, more sensitive molecular tests are less suitable for placement at primary care level in low-resource settings. In order to meet the WHO End TB targets, new diagnostic approaches are urgently needed to find the missing undiagnosed cases. Proteomics-derived blood host biomarkers have been explored because protein detection technologies are suitable for the point-of-care setting and could meet cost targets. This study aimed to find a biomarker signature that fulfills WHO's target product profile (TPP) for a TB screening. Twelve blood-based protein biomarkers from three sample populations (Vietnam, Peru, and South Africa) were analyzed individually and in combinations via advanced statistical methods and machine learning algorithms. The combination of I-309, SYWC and kallistatin showed the most promising results to discern active TB throughout the data sets meeting the TPP for a triage test in adults from two countries (Peru and South Africa). The top-performing individual markers identified at the global level (I-309 and SYWC) were also among the best-performing markers at country level in South Africa and Vietnam. This analysis clearly shows that a host protein biomarker assay is feasible in adults for certain geographical regions based on one or two biomarkers with a performance that meets minimal WHO TPP criteria.


Asunto(s)
Mycobacterium tuberculosis , Tuberculosis Pulmonar , Tuberculosis , Adulto , Humanos , Triaje/métodos , Tuberculosis/diagnóstico , Tuberculosis Pulmonar/diagnóstico , Biomarcadores , Proteínas Sanguíneas/análisis , Sensibilidad y Especificidad
2.
PLOS Glob Public Health ; 3(6): e0001555, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37267241

RESUMEN

Serological assays have been used in seroprevalence studies to inform the dynamics of COVID-19. Lateral flow immunoassay (LFIA) tests are a very practical technology to use for this objective; however, one of their challenges may be variable diagnostic performance. Given the numerous available LFIA tests, evaluation of their accuracy is critical before real-world implementation. We performed a retrospective diagnostic evaluation study to independently determine the diagnostic accuracy of 4 different antibody-detection LFIA tests: Now Check (Bionote), CareStart (Access bio), Covid-19 BSS (Biosynex) and OnSite (CTK Biotech). The sample panel was comprised of specimens collected and stored in biobanks; specifically, specimens that were RT-PCR positive for SARS-CoV-2 collected at various times throughout the COVID-19 disease course and those that were collected before the pandemic, during 2018 or earlier, from individuals with upper respiratory symptoms but were negative for tuberculosis. Clinical performance (sensitivity and specificity) was analyzed overall, and subset across individual antibody isotypes, and days from symptoms onset. A very high specificity (98% - 100%) was found for all four tests. Overall sensitivity was variable, ranging from 29% [95% CI: 21%-39%] to 64% [95% CI: 54%-73%]. When considering detection of IgM only, the highest sensitivity was 42% [95% CI: 32%-52%], compared to 57% [95% CI: 47%-66%] for IgG only. When the analysis was restricted to at least 15 days since symptom onset, across any isotype, the sensitivity reached 90% for all four brands. All four LFIA tests proved effective for identifying COVID-19 antibodies when two conditions were met: 1) at least 15 days have elapsed since symptom onset and 2) a sample is considered positive when either IgM or IgG is present. With these considerations, the use of this assays could help in seroprevalence studies or further exploration of its potential uses.

3.
Lancet Microbe ; 3(9): e672-e682, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35907429

RESUMEN

BACKGROUND: Whole-genome sequencing (WGS) of Mycobacterium tuberculosis complex has become an important tool in diagnosis and management of drug-resistant tuberculosis. However, data correlating resistance genotype with quantitative phenotypic antimicrobial susceptibility testing (AST) are scarce. METHODS: In a prospective multicentre observational study, 900 clinical M tuberculosis complex isolates were collected from adults with drug-resistant tuberculosis in five high-endemic tuberculosis settings around the world (Georgia, Moldova, Peru, South Africa, and Viet Nam) between Dec 5, 2014, and Dec 12, 2017. Minimum inhibitory concentrations (MICs) and resulting binary phenotypic AST results for up to nine antituberculosis drugs were determined and correlated with resistance-conferring mutations identified by WGS. FINDINGS: Considering WHO-endorsed critical concentrations as reference, WGS had high accuracy for prediction of resistance to isoniazid (sensitivity 98·8% [95% CI 98·5-99·0]; specificity 96·6% [95% CI 95·2-97·9]), levofloxacin (sensitivity 94·8% [93·3-97·6]; specificity 97·1% [96·7-97·6]), kanamycin (sensitivity 96·1% [95·4-96·8]; specificity 95·0% [94·4-95·7]), amikacin (sensitivity 97·2% [96·4-98·1]; specificity 98·6% [98·3-98·9]), and capreomycin (sensitivity 93·1% [90·0-96·3]; specificity 98·3% [98·0-98·7]). For rifampicin, pyrazinamide, and ethambutol, the specificity of resistance prediction was suboptimal (64·0% [61·0-67·1], 83·8% [81·0-86·5], and 40·1% [37·4-42·9], respectively). Specificity for rifampicin increased to 83·9% when borderline mutations with MICs overlapping with the critical concentration were excluded. Consequently, we highlighted mutations in M tuberculosis complex isolates that are often falsely identified as susceptible by phenotypic AST, and we identified potential novel resistance-conferring mutations. INTERPRETATION: The combined analysis of mutations and quantitative phenotypes shows the potential of WGS to produce a refined interpretation of resistance, which is needed for individualised therapy, and eventually could allow differential drug dosing. However, variability of MIC data for some M tuberculosis complex isolates carrying identical mutations also reveals limitations of our understanding of the genotype and phenotype relationships (eg, including epistasis and strain genetic background). FUNDING: Bill & Melinda Gates Foundation, German Centre for Infection Research, German Research Foundation, Excellence Cluster Precision Medicine of Inflammation (EXC 2167), and Leibniz ScienceCampus EvoLUNG.


Asunto(s)
Mycobacterium tuberculosis , Tuberculosis Resistente a Múltiples Medicamentos , Tuberculosis , Antituberculosos/farmacología , Genómica , Humanos , Mycobacterium tuberculosis/genética , Fenotipo , Estudios Prospectivos , Rifampin/farmacología , Tuberculosis/tratamiento farmacológico , Tuberculosis Resistente a Múltiples Medicamentos/diagnóstico
4.
Parasite Epidemiol Control ; 5: e00103, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30923755

RESUMEN

OBJECTIVES: Localized cutaneous leishmaniasis and its evolving forms diffuse cutaneous leishmaniasis, mucosal leishmaniasis and cutaneous leishmaniasis recidivans, together with the visceral leishmaniasis sequelae post-kala azar dermal leishmaniasis account for about one million dermal leishmaniases cases per year worldwide. Although not lethal, the dermal leishmaniases cause chronic and disfiguring skin lesions, which are an important cause of morbidity and stigma.Microscopy remains the reference test for diagnosis of dermal leishmaniasis; however, it has low and variable sensitivity and requires well trained personnel. The technical complexity and cost of the more sensitive molecular techniques (e.g. PCR) limits their application in routine diagnosis in endemic areas. Point-of-care (POC) tests for early diagnosis are much needed in order to benefit both patients and communities, by reducing the risk of both sequelae and Leishmania transmission. To this end we developed a Target Product Profile (TPP) for a POC test for dermal leishmaniases. METHODS: The TPP was defined through several rounds of discussions and by consensus with stakeholders and experts in dermal leishmaniases from different type of organizations and endemic regions. RESULTS AND CONCLUSIONS: A rapid, simple and robust test that can be implemented in resource-limited settings, enabling decentralized diagnosis and treatment of dermal leishmaniasis should be developed. Ideally it should enable the diagnosis of all forms of dermal leishmaniasis, but the minimally accepted target would be localized cutaneous leishmaniasis. A minimum sensitivity of 95% and specificity of 90% would be required. The consensus was that the POC test should target Leishmania antigens.

5.
Pathog Dis ; 76(4)2018 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-29846561

RESUMEN

There are many resources available to mycobacterial researchers, including culture collections around the world that distribute biomaterials to the general scientific community, genomic and clinical databases, and powerful bioinformatics tools. However, many of these resources may be unknown to the research community. This review article aims to summarize and publicize many of these resources, thus strengthening the quality and reproducibility of mycobacterial research by providing the scientific community access to authenticated and quality-controlled biomaterials and a wealth of information, analytical tools and research opportunities.


Asunto(s)
Bancos de Muestras Biológicas , Investigación Biomédica/métodos , Biología Computacional/métodos , Bases de Datos Genéticas , Infecciones por Mycobacterium/microbiología , Mycobacterium/genética , Mycobacterium/patogenicidad , Humanos , Reproducibilidad de los Resultados
6.
J Clin Microbiol ; 56(7)2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29695527

RESUMEN

A novel pan-Leishmania loop-mediated isothermal amplification (LAMP) assay for the diagnosis of cutaneous and visceral leishmaniasis (CL and VL) that can be used in near-patient settings was developed. Primers were designed based on the 18S ribosomal DNA (rDNA) and the conserved region of minicircle kinetoplast DNA (kDNA), selected on the basis of high copy number. LAMP assays were evaluated for CL diagnosis in a prospective cohort trial of 105 patients in southwest Colombia. Lesion swab samples from CL suspects were collected and were tested using the LAMP assay, and the results were compared to those of a composite reference of microscopy and/or culture in order to calculate diagnostic accuracy. LAMP assays were tested on samples (including whole blood, peripheral blood mononuclear cells, and buffy coat) from 50 suspected VL patients from Ethiopia. Diagnostic accuracy was calculated against a reference standard of microscopy of splenic or bone marrow aspirates. To calculate analytical specificity, 100 clinical samples and isolates from fever-causing pathogens, including malaria parasites, arboviruses, and bacteria, were tested. We found that the LAMP assay had a sensitivity of 95% (95% confidence interval [CI], 87.2% to 98.5%) and a specificity of 86% (95% CI, 67.3% to 95.9%) for the diagnosis of CL. With VL suspects, the sensitivity of the LAMP assay was 92% (95% CI, 74.9% to 99.1%) and its specificity was 100% (95% CI, 85.8% to 100%) in whole blood. For CL, the LAMP assay is a sensitive tool for diagnosis and requires less equipment, time, and expertise than alternative CL diagnostics. For VL, the LAMP assay using a minimally invasive sample is more sensitive than the gold standard. Analytical specificity was 100%.


Asunto(s)
Leishmaniasis/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificación de Ácido Nucleico , Colombia , ADN de Cinetoplasto/genética , ADN Protozoario/genética , Etiopía , Leishmania/genética , Técnicas de Diagnóstico Molecular/normas , Técnicas de Amplificación de Ácido Nucleico/normas , Estudios Prospectivos , ARN Ribosómico 18S/genética , Estándares de Referencia , Sensibilidad y Especificidad
7.
PLoS Negl Trop Dis ; 12(2): e0006264, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29444079

RESUMEN

BACKGROUND: Confirmatory diagnosis of visceral leishmaniasis (VL), as well as diagnosis of relapses and test of cure, usually requires examination by microscopy of samples collected by invasive means, such as splenic, bone marrow or lymph node aspirates. This causes discomfort to patients, with risks of bleeding and iatrogenic infections, and requires technical expertise. Molecular tests have great potential for diagnosis of VL using peripheral blood, but require well-equipped facilities and trained personnel. More user-friendly, and field-amenable options are therefore needed. One method that could meet these requirements is loop-mediated isothermal amplification (LAMP) using the Loopamp Leishmania Detection Kit, which comes as dried down reagents that can be stored at room temperature, and allows simple visualization of results. METHODOLOGY/PRINCIPAL FINDINGS: The Loopamp Leishmania Detection Kit (Eiken Chemical Co., Japan), was evaluated in the diagnosis of VL in Sudan. A total of 198 VL suspects were tested by microscopy of lymph node aspirates (the reference test), direct agglutination test-DAT (in house production) and rK28 antigen-based rapid diagnostic test (OnSite Leishmania rK39-Plus, CTK Biotech, USA). LAMP was performed on peripheral blood (whole blood and buffy coat) previously processed by: i) a direct boil and spin method, and ii) the QIAamp DNA Mini Kit (QIAgen). Ninety seven of the VL suspects were confirmed as cases by microscopy of lymph node aspirates. The sensitivity and specificity for each of the tests were: rK28 RDT 98.81% and 100%; DAT 88.10% and 78.22%; LAMP-boil and spin 97.65% and 99.01%; LAMP-QIAgen 100% and 99.01%. CONCLUSIONS/SIGNIFICANCE: Due to its simplicity and high sensitivity, rK28 RDT can be used first in the diagnostic algorithm for primary VL diagnosis, the excellent performance of LAMP using peripheral blood indicates that it can be also included in the algorithm for diagnosis of VL as a simple test when parasitological confirmatory diagnosis is required in settings that are lower than the reference laboratory, avoiding the need for invasive lymph node aspiration.


Asunto(s)
Leishmania donovani/aislamiento & purificación , Leishmaniasis Visceral/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificación de Ácido Nucleico/métodos , Adolescente , Adulto , Antígenos de Protozoos/genética , Niño , Preescolar , Femenino , Humanos , Leishmania donovani/genética , Leishmaniasis Visceral/epidemiología , Leishmaniasis Visceral/parasitología , Masculino , Persona de Mediana Edad , Juego de Reactivos para Diagnóstico , Sensibilidad y Especificidad , Sudán , Temperatura , Adulto Joven
8.
Malar J ; 17(1): 29, 2018 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-29334955

RESUMEN

BACKGROUND: Malaria rapid diagnostic tests (RDTs) are becoming widely adopted for case management at community level. However, reports and anecdotal observations indicate that the blood transfer step poses a significant challenge to many users. This study sought to evaluate the inverted cup device in the hands of health workers in everyday clinical practice, in comparison with the plastic pipette, and to determine the volume accuracy of the device made of a lower-cost plastic. METHODS: The volume accuracy of inverted cup devices made of two plastics, PMMA and SBC, was compared by transferring blood 150 times onto filter paper and comparing the blood spot areas with those produced by 20 reference transfers with a calibrated micropipette. The ease of use, safety and acceptability of the inverted cup device and the pipette were evaluated by 50 health workers in Nigeria. Observations were recorded on pre-designed questionnaires, by the health workers themselves and by trained observers. Focus group discussions were also conducted. RESULTS: The volume accuracy assessment showed that the device made from the low-cost material (SBC) delivered a more accurate volume (mean 5.4 µL, SD 0.48 µL, range 4.5-7.0 µL) than the PMMA device (mean 5.9 µL, SD 0.48 µL, range 4.9-7.2 µL). The observational evaluation demonstrated that the inverted cup device performed better than the pipette in all aspects, e.g. higher proportions of health workers achieved successful blood collection (96%, vs. 66%), transfer of the required blood volume (90%, vs. 58%), and blood deposit without any loss (95%, vs. 50%). Majority of health workers also considered it' very easy' to use (81%),'very appropriate' for everyday use (78%), and 50% of them reported that it was their preferred BTD. CONCLUSIONS: The good volume accuracy and high acceptability of the inverted cup device shown in this study, along with observed ease of use and safety in hands of health workers, further strengthens prior findings which demonstrated its higher accuracy as compared with other BTDs in a laboratory setting. Altogether, these studies suggest that the inverted cup device should replace other types of devices for use in day-to-day malaria diagnosis with RDTs.


Asunto(s)
Competencia Clínica/estadística & datos numéricos , Agentes Comunitarios de Salud/estadística & datos numéricos , Pruebas Diagnósticas de Rutina/métodos , Malaria/diagnóstico , Pruebas Diagnósticas de Rutina/estadística & datos numéricos , Grupos Focales , Humanos , Nigeria
9.
J Clin Microbiol ; 55(4): 1066-1073, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28100602

RESUMEN

The spread of multidrug-resistant (MDR) tuberculosis (TB) and extensively drug-resistant (XDR) TB hampers global efforts in the fight against tuberculosis. To enhance the development and evaluation of diagnostic tests quickly and efficiently, well-characterized strains and samples from drug-resistant tuberculosis patients are necessary. In this project, the Foundation for Innovative New Diagnostics (FIND) has focused on the collection, characterization, and storage of such well-characterized reference materials and making them available to researchers and developers. The collection is being conducted at multiple centers in Southeast Asia, South America, Eastern Europe, and soon the sub-Saharan Africa regions. Strains are characterized for their phenotypic resistances and MICs to first-line drugs (FLDs) and second-line drugs (SLDs) using the automated MGIT 960 system following validated procedures and WHO criteria. Analysis of resistance-associated mutations is done by whole-genome sequencing (WGS) using the Illumina NextSeq system. Mycobacterial interspersed repetitive-unit-variable-number tandem-repeat analysis and WGS are used to determine strain lineages. All strains are maintained frozen at -80°C ± 10°C as distinct mother and daughter lots. All strains are extensively quality assured. The data presented here represent an analysis of the initial part of the collection. Currently, the bank contains 118 unique strains with extracted genomic DNA and matched sputum, serum, and plasma samples and will be expanded to a minimum of 1,000 unique strains over the next 3 years. Analysis of the current strains by phenotypic resistance testing shows 102 (86.4%), 10 (8.5%), and 6 (5.1%) MDR, XDR, and mono/poly resistant strains, respectively. Two of the strains are resistant to all 11 drugs that were phenotypically tested. WGS mutation analysis revealed FLD resistance-associated mutations in the rpoB, katG, inhA, embB, embA, and pncA genes; SLD resistance in the gyrA, gyrB, rrs, eis, and tlyA genes; and ethionamide resistance in the ethA genes. Most important lineages are represented in the bank, and further collections have been initiated to increase geographic and lineage diversity. The bank provides highly characterized and high-quality strains as a resource for researchers and developers in support of the development and evaluation of new diagnostics and drug resistance detection tools.


Asunto(s)
Bancos de Muestras Biológicas , Farmacorresistencia Bacteriana , Mycobacterium tuberculosis/aislamiento & purificación , Tuberculosis Resistente a Múltiples Medicamentos/diagnóstico , Humanos , Cooperación Internacional , Mycobacterium tuberculosis/efectos de los fármacos , Tuberculosis Resistente a Múltiples Medicamentos/microbiología
10.
PLoS One ; 11(12): e0168074, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27936225

RESUMEN

BACKGROUND: Control and elimination of human African trypanosomiasis (HAT) can be accelerated through the use of diagnostic tests that are more accurate and easier to deploy. The goal of this work was to evaluate the immuno-reactivity of antigens and identify candidates to be considered for development of a simple serological test for the detection of Trypanosoma brucei gambiense or T. b. rhodesiense infections, ideally both. METHODOLOGY/PRINCIPAL FINDINGS: The reactivity of 35 antigens was independently evaluated by slot blot and ELISA against sera from both T. b. gambiense and T. b. rhodesiense infected patients and controls. The antigens that were most reactive by both tests to T. b. gambiense sera were the membrane proteins VSG LiTat 1.3, VSG LiTat 1.5 and ISG64. Reactivity to T. b. rhodesiense sera was highest with VSG LiTat 1.3, VSG LiTat 1.5 and SRA, although much lower than with T. b. gambiense samples. The reactivity of all possible combinations of antigens was also calculated. When the slot blot results of 2 antigens were paired, a VSG LiTat 1.3- ISG75 combination performed best on T. b. gambiense sera, while a VSG LiTat 1.3-VSG LiTat 1.5 combination was the most reactive using ELISA. A combination of SRA and either VSG LiTat 1.3 or VSG LiTat 1.5 had the highest reactivity on T. b. rhodesiense sera according to slot blot, while in ELISA, pairing SRA with either GM6 or VSG LiTat 1.3 yielded the best results. CONCLUSIONS: This study identified antigens that were highly reactive to T. b. gambiense sera, which could be considered for developing a serological test for gambiense HAT, either individually or in combination. Antigens with potential for inclusion in a test for T. b. rhodesiense HAT were also identified, but because their reactivity was comparatively lower, a search for additional antigens would be required before developing a test for this form of the disease.


Asunto(s)
Antígenos de Protozoos/inmunología , Tripanosomiasis Africana/diagnóstico , Humanos , Inmunoglobulina G/inmunología , Inmunoglobulina M/inmunología , Tripanosomiasis Africana/inmunología
11.
BMC Infect Dis ; 15: 384, 2015 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-26395447

RESUMEN

BACKGROUND: Visceral leishmaniasis (VL) can be fatal without timely diagnosis and treatment. Treatment efficacies vary due to drug resistance, drug toxicity and co-morbidities. It is important to monitor treatment responsiveness to confirm cure and curtail relapse. Currently, microscopy of spleen, bone marrow or lymph node biopsies is the only definitive method to evaluate cure. A less invasive test for treatment success is a high priority for VL management. METHODS: In this study, we describe the development of a capture ELISA based on detecting Leishmania donovani antigens in urine samples and comparison with the Leishmania Antigen ELISA, also developed for the same purpose. Both were developed as prototype kits and tested on patient urine samples from Sudan, Ethiopia, Bangladesh and Brazil, along with appropriate control samples from endemic and non-endemic regions. Sensitivity and specificity were assessed based on accurate detection of patients compared to control samples. One-Way ANOVA was used to assess the discrimination capacity of the tests and Cohen's kappa was used to assess their correlation. RESULTS: The Leishmania Antigen Detect ELISA demonstrated >90% sensitivity on VL patient samples from Sudan, Bangladesh and Ethiopia and 88% on samples from Brazil. The Leishmania Antigen ELISA was comparable in performance except for lower sensitivity on Sudanese samples. Both were highly specific. To confirm utility in monitoring treatment, urine samples were collected from VL patients at days 0, 30 and 180 post-treatment. For the Leishmania Antigen Detect ELISA, positivity was high at day 0 at 95%, falling to 21% at day 30. At day 180, all samples were negative, corresponding well with clinical cure. A similar trend was also seen for the Leishmania Antigen ELISA albeit; with lower positivity of 91% at Day 0 and more patients, remaining positive at Days 30 and 180. DISCUSSION: The Leishmania Antigen Detect and the Leishmania Antigen ELISAs are standardized, user- friendly, quantitative and direct tests to detect Leishmania during acute VL as well as to monitor parasite clearance during treatment. They are a clear improvement over existing options. CONCLUSION: The ELISAs provide a non-invasive method to detect parasite antigens during acute infection and monitor its clearance upon cure, filling an unmet need in VL management. Further refinement of the tests with more samples from endemic regions will define their utility in monitoring treatment.


Asunto(s)
Antígenos de Protozoos/inmunología , Ensayo de Inmunoadsorción Enzimática/métodos , Leishmania donovani/inmunología , Leishmania donovani/aislamiento & purificación , Leishmaniasis Visceral/diagnóstico , Leishmaniasis Visceral/inmunología , Antígenos de Protozoos/orina , Bangladesh , Brasil , Etiopía , Humanos , Leishmaniasis Visceral/parasitología , Leishmaniasis Visceral/orina , Sensibilidad y Especificidad , Sudán
12.
Parasitology ; 141(14): 1891-7, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25111885

RESUMEN

Variation in clinical accuracy of molecular diagnostic methods for cutaneous leishmaniasis (CL) is commonly observed depending on the sample source, the method of DNA recovery and the molecular test. Few attempts have been made to compare these variables. Two swab and aspirate samples from lesions of patients with suspected CL (n = 105) were evaluated alongside standard diagnosis by microscopic detection of amastigotes or culture of parasites from lesion material. Three DNA extraction methods were compared: Qiagen on swab and aspirate specimens, Isohelix on swabs and Boil/Spin of lesion aspirates. Recovery of Leishmania DNA was evaluated for each sample type by real-time polymerase chain reaction detection of parasitic 18S rDNA, and the diagnostic accuracy of the molecular method determined. Swab sampling combined with Qiagen DNA extraction was the most efficient recovery method for Leishmania DNA, and was the most sensitive (98%; 95% CI: 91-100%) and specific (84%; 95% CI: 64-95%) approach. Aspirated material was less sensitive at 80% (95% CI: 70-88%) and 61% (95% CI: 50-72%) when coupled to Qiagen or Boil-Spin DNA extraction, respectively. Swab sampling of lesions was painless, simple to perform and coupled with standardized DNA extraction enhances the feasibility of molecular diagnosis of CL.


Asunto(s)
Leishmania/aislamiento & purificación , Leishmaniasis Cutánea/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Adolescente , Adulto , Anciano , Niño , Preescolar , ADN Protozoario/genética , Estudios de Factibilidad , Femenino , Humanos , Leishmania/genética , Leishmaniasis Cutánea/parasitología , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Piel/parasitología , Manejo de Especímenes , Adulto Joven
13.
Malar J ; 11: 406, 2012 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-23217104

RESUMEN

BACKGROUND: As more point of care diagnostics become available, the need to transport and store perishable medical commodities to remote locations increases. As with other diagnostics, malaria rapid diagnostic tests (RDTs) must be highly reliable at point of use, but exposure to adverse environmental conditions during distribution has the potential to degrade tests and accuracy. In remote locations, poor quality diagnostics and drugs may have significant negative health impact that is not readily detectable by routine monitoring. This study assessed temperature and humidity throughout supply chains used to transport and store health commodities, such as RDTs. METHODS: Monitoring devices capable of recording temperature and humidity were deployed to Burkina Faso (8), Senegal (10), Ethiopia (13) and the Philippines (6) over a 13-month period. The devices travelled through government supply chains, usually alongside RDTs, to health facilities where RDTs are stored, distributed and used. The recording period spanned just over a year, in order to avoid any biases related to seasonal temperature variations. RESULTS: In the four countries, storage and transport temperatures regularly exceeded 30.0°C; maximum humidity level recorded was above 94% for the four countries. In three of the four countries, temperatures recorded at central storage facilities exceeded pharmaceutical storage standards for over 20% of the time, in another case for a majority of the time; and sometimes exceeded storage temperatures at peripheral sites. CONCLUSIONS: Malaria RDTs were regularly exposed to temperatures above recommended limits for many commercially-available RDTs and other medical commodities such as drugs, but rarely exceeded the recommended storage limits for particular products in use in these countries. The results underline the need to select RDTs, and other commodities, according to expected field conditions, actively manage the environmental conditions in supply chains in tropical and sub-tropical climates. This would benefit from a re-visit of current global standards on stability of medical commodities based in tropical and sub-tropical climatic zones.


Asunto(s)
Malaria/diagnóstico , Sistemas de Atención de Punto , Juego de Reactivos para Diagnóstico , Burkina Faso , Clima , Almacenaje de Medicamentos/normas , Etiopía , Humanos , Humedad , Filipinas , Sistemas de Atención de Punto/normas , Sistemas de Atención de Punto/estadística & datos numéricos , Juego de Reactivos para Diagnóstico/normas , Juego de Reactivos para Diagnóstico/estadística & datos numéricos , Servicios de Salud Rural , Senegal , Temperatura
14.
Am J Trop Med Hyg ; 87(3): 437-446, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22848096

RESUMEN

The National Malaria Control Center of Zambia introduced rapid diagnostic tests (RDTs) to detect Plasmodium falciparum as a pilot in some districts in 2005 and 2006; scale up at a national level was achieved in 2009. Data on RDT use, drug consumption, and diagnostic results were collected in three Zambian health districts to determine the impact RDTs had on malaria case management over the period 2004-2009. Reductions were seen in malaria diagnosis and antimalarial drug prescription (66.1 treatments per facility-month (95% confidence interval [CI] = 44.7-87.4) versus 26.6 treatments per facility-month (95% CI = 11.8-41.4)) pre- and post-RDT introduction. Results varied between districts, with significant reductions in low transmission areas but none in high areas. Rapid diagnostic tests may contribute to rationalization of treatment of febrile illness and reduce antimalarial drug consumption in Africa; however, their impact may be greater in lower transmission areas. National scale data will be necessary to confirm these findings.


Asunto(s)
Antimaláricos/uso terapéutico , Artemisininas/uso terapéutico , Pruebas Diagnósticas de Rutina/estadística & datos numéricos , Prescripciones de Medicamentos/estadística & datos numéricos , Malaria Falciparum/diagnóstico , Malaria Falciparum/tratamiento farmacológico , Preescolar , Bases de Datos Factuales , Pruebas Diagnósticas de Rutina/métodos , Humanos , Proyectos Piloto , Plasmodium falciparum , Estudios Retrospectivos , Zambia/epidemiología
15.
PLoS One ; 6(4): e18419, 2011 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-21494674

RESUMEN

BACKGROUND: While WHO recently recommended universal parasitological confirmation of suspected malaria prior to treatment, debate has continued as to whether wide-scale use of rapid diagnostic tests (RDTs) can achieve this goal. Adherence of health service personnel to RDT results has been poor in some settings, with little impact on anti-malarial drug consumption. The Senegal national malaria control programme introduced universal parasite-based diagnosis using malaria RDTs from late 2007 in all public health facilities. This paper assesses the impact of this programme on anti-malarial drug consumption and disease reporting. METHODS AND FINDINGS: Nationally-collated programme data from 2007 to 2009 including malaria diagnostic outcomes, prescription of artemisinin-based combination therapy (ACT) and consumption of RDTs in public health facilities, were reviewed and compared. Against a marked seasonal variation in all-cause out-patient visits, non-malarial fever and confirmed malaria, parasite-based diagnosis increased nationally from 3.9% of reported malaria-like febrile illness to 86.0% over a 3 year period. The prescription of ACT dropped throughout this period from 72.9% of malaria-like febrile illness to 31.5%, reaching close equivalence to confirmed malaria (29.9% of 584,873 suspect fever cases). An estimated 516,576 courses of inappropriate ACT prescription were averted. CONCLUSIONS: The data indicate high adherence of anti-malarial prescribing practice to RDT results after an initial run-in period. The large reduction in ACT consumption enabled by the move from symptom-based to parasite-based diagnosis demonstrates that effective roll-out and use of malaria RDTs is achievable on a national scale through well planned and structured implementation. While more detailed information on management of parasite-negative cases is required at point of care level to assess overall cost-benefits to the health sector, considerable cost-savings were achieved in ACT procurement. Programmes need to be allowed flexibility in management of these funds to address increases in other programmatic costs that may accrue from improved diagnosis of febrile disease.


Asunto(s)
Antimaláricos/uso terapéutico , Pruebas Diagnósticas de Rutina , Malaria/diagnóstico , Malaria/tratamiento farmacológico , Juego de Reactivos para Diagnóstico , Animales , Humanos , Parásitos/aislamiento & purificación , Salud Pública/estadística & datos numéricos , Senegal
16.
Malar J ; 10: 30, 2011 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-21303528

RESUMEN

BACKGROUND: Malaria rapid diagnostic tests (RDTs) are increasingly used by remote health personnel with minimal training in laboratory techniques. RDTs must, therefore, be as simple, safe and reliable as possible. Transfer of blood from the patient to the RDT is critical to safety and accuracy, and poses a significant challenge to many users. Blood transfer devices were evaluated for accuracy and precision of volume transferred, safety and ease of use, to identify the most appropriate devices for use with RDTs in routine clinical care. METHODS: Five devices, a loop, straw-pipette, calibrated pipette, glass capillary tube, and a new inverted cup device, were evaluated in Nigeria, the Philippines and Uganda. The 227 participating health workers used each device to transfer blood from a simulated finger-prick site to filter paper. For each transfer, the number of attempts required to collect and deposit blood and any spilling of blood during transfer were recorded. Perceptions of ease of use and safety of each device were recorded for each participant. Blood volume transferred was calculated from the area of blood spots deposited on filter paper. RESULTS: The overall mean volumes transferred by devices differed significantly from the target volume of 5 microliters (p < 0.001). The inverted cup (4.6 microliters) most closely approximated the target volume. The glass capillary was excluded from volume analysis as the estimation method used is not compatible with this device. The calibrated pipette accounted for the largest proportion of blood exposures (23/225, 10%); exposures ranged from 2% to 6% for the other four devices. The inverted cup was considered easiest to use in blood collection (206/226, 91%); the straw-pipette and calibrated pipette were rated lowest (143/225 [64%] and 135/225 [60%] respectively). Overall, the inverted cup was the most preferred device (72%, 163/227), followed by the loop (61%, 138/227). CONCLUSIONS: The performance of blood transfer devices varied in this evaluation of accuracy, blood safety, ease of use, and user preference. The inverted cup design achieved the highest overall performance, while the loop also performed well. These findings have relevance for any point-of-care diagnostics that require blood sampling.


Asunto(s)
Recolección de Muestras de Sangre/métodos , Pruebas Diagnósticas de Rutina/métodos , Malaria/diagnóstico , Seguridad de la Sangre/métodos , Recolección de Muestras de Sangre/instrumentación , Pruebas Diagnósticas de Rutina/instrumentación , Personal de Salud , Humanos , Malaria/sangre , Nigeria , Filipinas , Reproducibilidad de los Resultados , Uganda
17.
Malar J ; 9: 129, 2010 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-20470441

RESUMEN

BACKGROUND: Accurate diagnosis is essential for prompt and appropriate treatment of malaria. While rapid diagnostic tests (RDTs) offer great potential to improve malaria diagnosis, the sensitivity of RDTs has been reported to be highly variable. One possible factor contributing to variable test performance is the diversity of parasite antigens. This is of particular concern for Plasmodium falciparum histidine-rich protein 2 (PfHRP2)-detecting RDTs since PfHRP2 has been reported to be highly variable in isolates of the Asia-Pacific region. METHODS: The pfhrp2 exon 2 fragment from 458 isolates of P. falciparum collected from 38 countries was amplified and sequenced. For a subset of 80 isolates, the exon 2 fragment of histidine-rich protein 3 (pfhrp3) was also amplified and sequenced. DNA sequence and statistical analysis of the variation observed in these genes was conducted. The potential impact of the pfhrp2 variation on RDT detection rates was examined by analysing the relationship between sequence characteristics of this gene and the results of the WHO product testing of malaria RDTs: Round 1 (2008), for 34 PfHRP2-detecting RDTs. RESULTS: Sequence analysis revealed extensive variations in the number and arrangement of various repeats encoded by the genes in parasite populations world-wide. However, no statistically robust correlation between gene structure and RDT detection rate for P. falciparum parasites at 200 parasites per microlitre was identified. CONCLUSIONS: The results suggest that despite extreme sequence variation, diversity of PfHRP2 does not appear to be a major cause of RDT sensitivity variation.


Asunto(s)
Antígenos de Protozoos/genética , Inmunoensayo/métodos , Malaria Falciparum/diagnóstico , Plasmodium falciparum/genética , Plasmodium falciparum/aislamiento & purificación , Proteínas Protozoarias/genética , Animales , Antígenos de Protozoos/inmunología , ADN Protozoario/genética , Variación Genética , Humanos , Inmunoensayo/normas , Malaria Falciparum/genética , Malaria Falciparum/parasitología , Plasmodium falciparum/inmunología , Reacción en Cadena de la Polimerasa , Proteínas Protozoarias/inmunología , Juego de Reactivos para Diagnóstico , Sensibilidad y Especificidad , Análisis de Secuencia de ADN
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...