RESUMEN
BACKGROUND: Interns experience challenges in their transition from medical school to residency. Orientation is traditionally delivered by faculty and administrators and often does not address practical skills needed by interns during the transition. OBJECTIVES: The objective is to address traditional orientation gaps and improve incoming interns' transition experience. Methods: We identified opportunities with our intern orientation using a quality improvement methodology. Plan Do Study Act (PDSA) cycle 1 consisted of a pilot boot camp. PDSA cycle 2 was conducted over two weeks, June 9-23, 2021, at the Detroit Medical Center, Detroit, MI. Participation was voluntary. Residents were assigned incoming interns on a 1:1 basis. Five virtual sessions were conducted addressing: daily workflow, documentation, presentation skills, and utilization of the Electronic Health Record (EHR). All participants received pre- and post-program surveys. Results: Twenty-two rising second- and third-year residents (26%) and 22 incoming interns (58%) participated. There was a significant improvement in the understanding of daily workflow (mean improvement 0.957, p=0.003), and most tasks associated with EHR including comfort with the sign-out process (mean improvement 1.21; p=0.002), accessing specific team lists (mean improvement 1.75, p=0.001), writing orders (mean improvement 1.41; p=0.002), composing documentation (mean improvement 1.23; p=0.001). Writing notes improved significantly (mean improved by 0.52; p=0.04). Nearly all (93.2%) stated the program achieved its overall goals and believed (92.9%) the program should be continued for incoming intern classes. CONCLUSION: A targeted orientation bootcamp led by near-peers positively impacted the intern experience improving understanding of day-to-day responsibilities and comfort utilizing the electronic health record.
RESUMEN
Transcatheter mitral valve repair (TMVR) with the MitraClip system is now approved for degenerative and functional mitral regurgitation (MR). Atrial fibrillation (AF) is commonly seen in MR. In our study, we perform a pooled analysis of the existing data to investigate the outcomes of MitraClip in patients with versus without AF. We conducted a systematic search of PubMed, Google Scholar, and SCOPUS databases through December, 2022 for studies comparing the outcomes of TMVR using the MitraClip in patients with preexisting AF versus those without AF. A meta-analysis was performed to investigate the primary outcomes of all-cause mortality and heart failure (HF) hospitalization. Secondary outcomes were cardiovascular mortality, in-hospital mortality, stroke, New York Heart Association class I or II at follow-up, length of hospital stay, and procedural time. A total of 10 studies (n = 24,111; AF = 12,789; no AF = 11,322) were included in the final analysis. Preexisting AF was associated with higher overall all-cause mortality (odds ratio 1.55, 95% confidence interval 1.32 to 1.83, p <0.0002) and higher overall HF hospitalization rate (odds ratio 1.3, 95% confidence interval 1.08 to 1.56, p <0.0154). There was no statistically significant difference in cardiovascular mortality, in-hospital mortality, stroke, length of hospital stay, procedural time, or New York Heart Association class I/II at follow-up comparing AF versus no AF. The presence of AF in patients who underwent TMVR with MitraClip is associated with higher all-cause mortality and HF hospitalization. This should be taken into consideration in the management of MR patients.
RESUMEN
Background and objective Aspiration thrombectomy devices, such as the AngioJet Solent Omni (Boston Scientific Corporation, Marlborough, MA) have been approved by the US FDA for the treatment of thrombi in peripheral arterial disease, venous disease, and AV fistulas. However, there is a dearth of real-world data on the most common modes of failure and complications associated with the AngioJet Solent Omni. In this study, we aimed to address this scarcity of data. Methods The MAUDE (Manufacturer and User Facility Device Experience) database was queried for reports of device failure and adverse events spanning the period from October 2012 to December 2021. Results A total of 499 events were reported during the study period. After the exclusion of duplicate reports, the final analysis included 450 reports. The most common mode of failure was catheter breakage/kinking during suction thrombectomy with 137 reports (30%). The most common vessel associated with events was the superficial femoral artery or vein, which was documented in 82 reports (18.2%). The most common adverse clinical outcome was the embedding of a piece of the device in the patient, which occurred in seven reports (1.6%). There were seven (1.6%) events of death reported during the period studied. Conclusions Based on our findings, theAngioJet Solent Omni device provides promising results; however, it is important to evaluate device safety. It is associated with complications including device embedment, catheter breakage/kinking, and death, and these adverse events are linked to patient characteristics and risk factors.
RESUMEN
Background Aspiration thrombectomy devices, such as the AngioVac, allow the removal of thrombus, especially in patients with contraindications to anticoagulation use. The AngioVac was approved by the U.S. Food and Drug Administration to remove fresh, soft thrombi or emboli during extracorporeal bypass for up to six hours. Real-world data on the most common modes of failure and complications associated with the AngioVac are unavailable. Methods The Manufacturer and User Facility Device Experience database was queried for reports of the AngioVac device failure and adverse events from April 2013 to March 2022. Categorical variables were described as numbers, and all statistical calculations were performed with IBM SPSS Statistics, version 27.0 (IBM Corp., Armonk, NY). Results A total of 115 events were reported during the study period. After the exclusion of duplicate reports, the final cohort included 93 reports. The most common mode of failure for the AngioVac was physical damage of the device, with 13 reports (14%). The most common vessels associated with events were the superior vena cava and inferior vena cava, occurring in 23 reports (24.7%). The most common adverse clinical events were pulmonary embolism (PE), occurring in 33 reports (35.5%), and perforation, occurring in 16 reports (17.2%). Other less frequent adverse outcomes were arrhythmias, stroke, and foreign body device embedment. There were 45 deaths reported with the use of the AngioVac. Conclusions Aspiration thrombectomy devices provide promising efficacy; however, physicians should be aware of known adverse outcomes, even if they are infrequent. Based on this analysis, PE and vessel perforation were the most common adverse outcomes. Furthermore, the most common mode of failure was secondary to physical damage of the device.
RESUMEN
BACKGROUND: The Diamondback 360® Coronary Orbital Atherectomy System (Cardiovascular Systems Inc., St. Paul, MN) is the first and only orbital atherectomy system approved by the US FDA for the treatment of severely calcified lesions. While the device has proven to be safe in clinical trials, real-world data are minimal. METHODS: The Manufacturer and User Facility Device Experience (MAUDE) database was queried for reports on the Diamondback 360® Coronary from January 2019 to January 2022. RESULTS: A total of 566 events were reported during the study period. After the exclusion of duplicate reports, the final cohort included 547 reports. The most common mode of failure was break or separation of a device part (40.4%, n = 221) mainly due to breaking in the tip of the ViperWire (66.1%), driveshaft (22.7%), or crown (12.2%). The most common vessel associated with events was the left anterior descending artery (31.4%), followed by the right coronary artery (26.9%), left circumflex (21.6%), and left main coronary artery (6.4%). The most common clinical adverse outcome was perforation (33.0%, n = 181) with 23.7% resulting in cardiac tamponade. Most perforation cases were treated by covered stent (44.2%), surgery (30.5%), stent (98%), and balloon angioplasty (9%). There were 89 (16.3%) events of death with 67% due to perforation (p < 0.001). CONCLUSION: Our study provided a glimpse of real-world adverse outcomes and common modes of failure due to orbital atherectomy. The most common mode of failure was the break or separation of a device part and the most common complication was perforation according to the MAUDE database. It will help physicians to anticipate complications and escalate care appropriately.
RESUMEN
INTRODUCTION: Atrial fibrillation/flutter (AF) is common among patients with pulmonary hypertension (PH) and is associated with poor clinical outcomes. AF has been shown to occur more commonly among patients with postcapillary PH, although AF also occurs among patients with precapillary PH. The goal of this study was to evaluate the independent impact of PH hemodynamic phenotype on incident AF among patients with PH. METHODS: We retrospectively identified 262 consecutive patients, without a prior diagnosis of atrial arrhythmias, seen at the PH clinic at Mayo Clinic, Florida, between 1997 and 2017, who had right heart catheterization and echocardiography performed, with follow-up for outcomes through 2021. Kaplan-Meier analysis and Cox-proportional hazards regression modeling were used to evaluate the independent effect of PH hemodynamic phenotype on incident AF. RESULTS: Our study population was classified into two broad PH hemodynamic groups: precapillary (64.9%) and postcapillary (35.1%). The median age was 59.5 years (Q1: 48.4, Q3: 68.4), and 72% were female. In crude models, postcapillary PH was significantly associated with incident AF (HR 2.17, 95% CI: 1.26-3.74, p = 0.005). This association was lost following multivariable adjustment, whereas left atrial volume index remained independently associated with incident AF (aHR 1.30, 95% CI: 1.09-1.54, p = 0.003). CONCLUSION: We found PH hemodynamic phenotype was not significantly associated with incident AF in our patient sample; however, echocardiographic evidence of left atrial remodeling appeared to have a greater impact on AF development. Larger studies are needed to validate these findings and identify potential modifiable risk factors for AF in this population.
Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Hipertensión Pulmonar , Humanos , Femenino , Masculino , Fibrilación Atrial/complicaciones , Fibrilación Atrial/epidemiología , Fibrilación Atrial/diagnóstico , Hipertensión Pulmonar/epidemiología , Hipertensión Pulmonar/complicaciones , Estudios Retrospectivos , Atrios Cardíacos , Factores de Riesgo , Aleteo Atrial/complicaciones , HemodinámicaRESUMEN
Since its Food and Drug Administration approval in January 2007, the Angiosculpt scoring balloon catheter has been widely utilized in severely calcified stenotic vascular lesions. We sought to characterize the complication rates, failure modes, and outcomes associated with the Angiosculpt catheter. Using queried events from October 2013 to December 2020 from the Food and Drug Administration Manufacturer and User Facility Device Experience database, we analyzed the Angiosculpt scoring balloon catheter complication rates and mode of failure. A total of 248 complications were reported. Most reported complications occurred in the superficial femoral artery (SFA) (19.4%, nâ¯=â¯48), followed by the left anterior descending artery (8.1%, nâ¯=â¯20). Severe vessel calcifications were reported in (26.6%, nâ¯=â¯66) of the complications. Most complications occurred with damage to the device, such as tip break (44.8%, nâ¯=â¯111) and balloon rupture (26.6%, nâ¯=â¯66). Some complications were due to difficulties in the withdrawal of the catheter (23.8%, nâ¯=â¯59). Balloon rupture is observed at a significantly higher rate amongst calcified vessels (60.6% vs 14.8%), Pâ¯=â¯< 0.001, and in cases involving the SFA (39.4% vs 11.3%), Pâ¯=â¯< 0.001. All-cause complications in calcified vessels are associated with the SFA (39.4% vs 12.5%), Pâ¯=â¯< 0.001, and left anterior descending artery (16.7% vs 5.1%), Pâ¯=â¯< 0.001. The Angiosculpt scoring balloon catheter has a relatively low complication rate. Most complications were associated with a device tip break, balloon rupture, and difficulties in withdrawal in severely calcified vessels.
Asunto(s)
Catéteres , Vasos Coronarios , Humanos , Resultado del TratamientoRESUMEN
QT prolongation is present in 26-52% of cases of Takotsubo cardiomyopathy (TCM). It has been postulated to result from reduced cardiac repolarization reserve and reflects the transient myocardial insult observed in TCM. Bradycardia-induced QT interval prolongation is amplified by the occurrence of TCM, a combination that potentially carries a significant risk for torsade de pointes (TdP). We present a unique case of an 80-year-old female with TCM-related cardiac arrest. The patient had acquired long QT syndrome in which TCM myocardial insult led to the precipitation of a third-degree atrioventricular (AV) block and subsequent bradycardia-induced TdP. Due to the lack of robust literature, there is no clear guideline in the management of third-degree AV block in the setting of TCM. In our case, because of recurrent ventricular tachycardia (VT) and ventricular fibrillation (VF) arrest, we opted for temporary pacing at a high ventricular rate, followed by a biventricular implantable cardioverter-defibrillator (BiV/ICD). Follow-up 3 months later revealed improvement of left ventricular (LV) dysfunction and resolution of QT prolongation. However, the noticed AV conduction defects persisted. In the available literature, we identified five reported cases that bear similarity with our patient's presentation. The identified cases were middle-aged to elderly females with no significant cardiac history, who exhibited a similar triad of TCM associated with high-grade AV block, acquired long QT syndrome, and a rapid progression of bradycardia-induced TdP, resulting in a near cardiac arrest within the first 24 - 48 h of admission. It is crucial to monitor corrected QT (QTc), correct electrolyte abnormalities, and minimize QT-prolonging medications in patients with TCM. The recognition of AV conduction defects in patients with TCM is critical, especially if it is associated with significant QT prolongation. Such situations are underrecognized, and are potentially fatal, necessitating close monitoring and timely intervention.
RESUMEN
Antibiotic-associated diarrhea (AAD) describes any unexplained diarrhea associated with the use of antibiotics. AAD develops through diverse mechanisms, ranging from pharmacologic effects on gut motility to disturbance of the function and carbohydrate metabolism of the indigenous intestinal flora and overgrowth by pathogenic micro-organisms. Clostridioides difficile-associated diarrhea (CDAD) is a subset of AAD; however, it accounts only for a small percentage of diarrhea caused by antibiotics. Diarrhea has been reported as a side effect of daptomycin use, nevertheless, it's thought to be mild and carries significantly less risk of diarrhea than other alternative treatments of S. aureus bacteremia, i.e., vancomycin or cefazolin. The authors present an interesting case of daptomycin-associated diarrhea presenting with a protracted and severe course. Patient symptoms didn't improve with empiric Clostridioides difficile therapy and CDAD testing was negative. Diarrhea promptly resolved after discontinuation of daptomycin. Furthermore, a thorough literature review was conducted and discussed in this article to raise awareness of this under-recognized complication. Clinicians should be mindful of daptomycin-associated diarrhea along with its presentation and treatment. Further studies are needed to identify the pathophysiology of daptomycin-associated diarrhea and other forms of AAD. Understanding their mechanism could help prevent, treat, and reduce the significant medical costs associated with antibiotic adverse events.
RESUMEN
Background: The Turnpike catheters (Teleflex, Wayne, PA, USA) is a microcatheter that was approved by the Food and Drug Administration in November 2014 to be used to access discrete regions of the coronary and peripheral vasculature. Methods: The Manufacturer and User Facility Device Experience (MAUDE) database was queried for reports of the Turnpike catheters from March 2015 through August 2021. Results: A total of 216 reports were found during the study period. After excluding duplicate reports (n = 21), our final cohort included 195 reports. The most common failure mode was catheter tip break or detachment (83%, n = 165) which was significantly associated with over-torquing (p-value = 0.025). The most common clinical consequence was the entrapment of the catheter (33%, n = 65), followed by vessel injury (7.8% n = 15) and vessel occlusion (3.6%, n = 7). Most patients had no consequences (47.0%, n = 93) or recovered (11%, n = 22). A total of 4 deaths were reported. 35.8% of reports (n = 69) specified the presence of severe calcification in the target vessel. Over torquing by interventionists was reported in 33.2% of events (n = 64). Conclusion: Despite clinical trials demonstrating the safety of the Turnpike catheters, complications can still occur. These data serve to inform operators about potentional risks and complications associated with the use of the device. Physicians should avoid over-torqueing which seems to be the most common mechanism for device complications.
RESUMEN
Certain clinical scenarios should alert a physician to take a deeper look into causative pathological processes. This was evident in the case of a 41-year-old man who presented for recurrent micro thromboembolic strokes, which is atypical for the patient's age. Our desire to explain the pathological process led to the rare finding of a plasminogen activator inhibitor-1 polymorphism, which has been associated with an increased risk of cerebrovascular thrombosis. A defect in this pathway leads to the inhibition of the tissue plasminogen activator protein. This genetic polymorphism has relatively been unexplored in recent medical literature, and we are hoping that our case may inspire future research that could help potential targets of risk factor stratifications as well as the development of novel pharmacological options.
RESUMEN
Antiphospholipid syndrome (APS) is a rare coagulopathic disorder diagnosed with a combination of clinical/imaging findings with specific antibody titer elevations over a period of 12 weeks. The following case report will discuss the unusual and challenging hospital course of a patient with extensive autosomal dominant polycystic kidney disease (ADPKD) being treated for a multi-drug resistant urinary tract infection (UTI). The patient later developed multiple deep vein thrombosis (DVT) and was found to have antiphospholipid syndrome. Warfarin, the anticoagulant of choice for antiphospholipid syndrome, has a higher likelihood of intracerebral hemorrhage than direct oral anticoagulants. This is particularly challenging since patients with autosomal dominant polycystic kidney disease have a higher propensity to develop intracranial aneurysms (ICA).
RESUMEN
Lutetium-177 (177Lu) dotatate is a type of peptide receptor radioligand therapy (PRRT) using radiolabeled somatostatin for patients with progressive somatostatin receptor-positive gastrointestinal neuroendocrine tumors. While cases of therapy-related myeloid neoplasms (t-MN) have been described as a consequence of 177 Lu dotatate, there are no reports of hemolytic anemia associated with therapy. We present a case of a 68-year-old woman with metastatic low-grade neuroendocrine tumor who presented four weeks after the second dose of 177Lu dotatate with progressive fatigue and dyspnea. Laboratory workup was remarkable for hemolytic anemia. Lutetium-177 dotatate-induced hemolysis was suspected after ruling out other causes. Corticosteroid treatment was initiated with improvement in hemoglobin, and dose-reduced PRRT was planned upon discharge. Six months into the treatment course of 177Lu dotatate, macrocytic anemia was noticed on routine follow-up with normal vitamin B12 and folic acid levels. A bone marrow biopsy was done, revealing myelodysplastic syndrome (MDS) features. Given the temporal relationship between drug introduction and the objective findings, early-onset 177Lu dotatate-induced MDS was diagnosed with a plan for close hematologic follow-up. Myelodysplastic syndrome should be suspected when megaloblastic anemia develops in patients with previous 177Lu dotatate therapy. The latency period between initial treatment and MDS diagnosis reported in the literature ranges between 15 months to seven years. Apart from the unusually early onset of MDS, what is unique about our case is the development of hemolytic anemia after administration of PRRT. The clinical course and the brisk response to steroid therapy, suggest other mechanisms of PRRT toxicity besides DNA breaks, genetic mutations, and myelosuppression by an immune-mediated component that likely plays a role in 177Lu dotatate toxicity. Further investigation and monitoring are needed to identify the frequency of such adverse events and the pathophysiology of their occurrence.
RESUMEN
Background: We aim to conduct a comprehensive meta-analysis encompassing all studies to assess the efficacy of Vascepa in patients with diabetes mellitus (DM) in preventing or treating existing coronary artery disease (CAD). Methods: Digital databases were queried. Odds ratios (OR) were calculated for the following outcomes: composite outcome, all-cause mortality, and cardiovascular mortality. Results: A total of 4 randomized control trials (33,092 patients; Vascepa n = 16586; Placebo n = 16506) were included in our analysis. The overall mean age was 64.3 years old (Vascepa = 64.3 years; Placebo = 64.3 years). The sample was 61.5% male (Vascepa = 60.8%; Placebo = 62.1%). In patients with DM, Vascepa was found to have no significant effect on the primary composite outcome (OR 0.97, 95%CI 0.91-1.04, p > 0.05), all-cause mortality (OR 0.96, 95%CI 0.90-1.03, p > 0.05), and cardiovascular mortality (OR 0.90, 95%CI 0.74-1.10, p > 0.05). Subgroup analysis by Vascepa type and treatment type was similarly non-significant. Conclusion: Our study concluded that Vascepa did not affect cardiovascular outcomes in patients with DM.
RESUMEN
As more patients recover from COVID-19 infection, long-term complications are beginning to arise. Our case report will explore a debilitating long-term complication, Post-COVID Interstitial Lung Disease (PC-ILD). We will introduce a patient who developed PC-ILD in the setting of diffuse large B-cell lymphoma, outlining a difficult hospital course, including a positive COVID-19 polymerase chain reaction (PCR) for more than 3 months. We will then discuss the human body's physiological response to the virus and how our patient was not able to adequately mount an immune response. Finally, the pathophysiology of PC-ILD will be explored and correlated with the patient's subsequent computed tomographic images obtained over a 3-month period. The difficult hospital course and complex medical decision-making outlined in this case report serve as a reminder for health care providers to maintain vigilance in protecting our most vulnerable patient population from such a devastating disease process.
Asunto(s)
COVID-19/complicaciones , Huésped Inmunocomprometido , Enfermedades Pulmonares Intersticiales/complicaciones , Enfermedades Pulmonares Intersticiales/virología , Linfoma de Células B Grandes Difuso/complicaciones , SARS-CoV-2/patogenicidad , Anciano , COVID-19/virología , Humanos , Linfoma de Células B Grandes Difuso/inmunología , Masculino , SARS-CoV-2/inmunología , Síndrome Post Agudo de COVID-19RESUMEN
Background: Transcatheter aortic valve implantation (TAVI) has emerged as the standard of care for patients with severe aortic stenosis who are at high surgical risk. However, transcatheter valves can degenerate, and redo TAVI has been reported after surgical aortic valve implantation and post initial TAVI. Case Report: We describe the case of a 70-year-old male who presented with decompensated heart failure secondary to severe prosthetic valve insufficiency. The patient had a history of distant triple coronary artery bypass surgery in 2004, surgical ascending aortic aneurysm repair and stentless aortic valve replacement in 2012, and transcatheter CoreValve (Medtronic) implantation in 2015 for the failing stentless aortic valve. In 2019, the patient presented with heart failure symptoms. A 29-mm SAPIEN 3 valve (Edwards Lifesciences) was implanted for the third time (valve-in-valve-in-valve) with excellent clinical and echocardiographic results and no evidence of coronary obstruction. Conclusion: Early (<5 years) bioprosthetic valve insufficiency after initial valve-in-valve implantation can be successfully treated with a second TAVI.
RESUMEN
Esophago-pericardial fistulae is a rare and dreaded entity. Most reported cases in the literature were described in association with advanced upper gastrointestinal malignancies, prior surgical procedures, and radiofrequency atrial fibrillation ablation. It has been rarely reported in association with benign esophageal conditions. Surgery had been the mainstay of treatment, but there are increasingly reported cases treated successfully with esophageal stenting and pericardial drainage. In this article, we report a novel case of an esophago-pericardial fistulae occurring as a sequela of esophageal stent placed for the management of Boerhaave syndrome.
Asunto(s)
Fístula Esofágica , Perforación del Esófago , Enfermedades del Mediastino , Fístula Esofágica/etiología , Fístula Esofágica/cirugía , Perforación del Esófago/etiología , Perforación del Esófago/cirugía , Humanos , Enfermedades del Mediastino/etiología , Enfermedades del Mediastino/cirugía , StentsRESUMEN
There has been an accumulating evidence of association between COVID-19 (coronavirus disease 2019) infection and cardiovascular complications. We describe a case of a 58-year-old lady with a history of systolic heart failure and COVID-19 infection, who developed persistent symptomatic bradycardia, requiring pacemaker placement as unusual conductive tissue involvement of this novel coronavirus.
Asunto(s)
Bradicardia/diagnóstico , Bradicardia/virología , COVID-19/complicaciones , Bradicardia/terapia , Diagnóstico Diferencial , Electrocardiografía , Femenino , Humanos , Persona de Mediana Edad , Marcapaso Artificial , SARS-CoV-2RESUMEN
Takotsubo cardiomyopathy (TC) is a syndrome characterized by acute and transient regional systolic myocardial dysfunction. TC often mimics myocardial infarction without obstructive coronary disease. We present a case of a 48-year-old woman who developed TC following the onset of polymorphic ventricular tachycardia in the setting of methadone intoxication.
Asunto(s)
Taquicardia Ventricular , Cardiomiopatía de Takotsubo , Electrocardiografía , Femenino , Humanos , Metadona/efectos adversos , Persona de Mediana Edad , Taquicardia Ventricular/inducido químicamente , Cardiomiopatía de Takotsubo/inducido químicamenteRESUMEN
INTRODUCTION: Takotsubo Syndrome (TS) patients are at high risk of developing atrial fibrillation. We sought to investigate the outcomes and economic impact of atrial fibrillation on TS patients utilizing the National Inpatient Sample. METHODS: Patients with TS were identified in the National Inpatient Sample (NIS) database between 2010 and 2014 using the International Classification of Diseases, 9th Revision, Clinical Modification (ICD-9-CM), and subsequently were divided into two groups, those with and without atrial fibrillation. The primary outcome was all-cause in-hospital mortality in the two groups. Secondary outcomes were in-hospital complications. We also evaluated the length of hospital stay and the cost of hospitalization. Propensity score-matched analysis was performed to address potential confounding factors. RESULTS: Among the study population, the prevalence of atrial fibrillation was 17.57%. After matching, the atrial fibrillation group had no significant increase of in-hospital mortality (OR: 1.13; 95% CI: 0.94-1.35, pâ¯=â¯0.211). However, atrial fibrillation patients were more likely to develop cardiac arrest and ventricular arrhythmias (OR: 1.51, 95% CI: 1.26-1.80, pâ¯<â¯0.0001), have higher rate of major cardiac complications when combined as a single endpoint in-hospital complication (OR: 1.16, 95% CI: 1.04-1.29, p: 0.006), also they were more likely to stay longer in hospital (OR: 1.13, 95% CI: 1.08-1.19, pâ¯<â¯0.0001), and have increased cost of hospitalization (OR: 1.13, 95% CI 1.07-1.20, pâ¯<â¯0.0001). CONCLUSION: Atrial fibrillation does not increase in-hospital mortality in patients presenting with TS. However atrial fibrillation is associated with an increased risk of ventricular arrhythmias, length of stay, non-routine discharges and cost of hospitalization.