Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Am Med Inform Assoc ; 31(8): 1735-1742, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38900188

RESUMEN

OBJECTIVES: Designing a framework representing radiology results in a standards-based data structure using joint Radiological Society of North America/American College of Radiology Common Data Elements (CDEs) as the semantic labels on standard structures. This allows radiologist-created report data to integrate with artificial intelligence-generated results for use throughout downstream systems. MATERIALS AND METHODS: We developed a framework modeling radiology findings as Health Level 7 (HL7) Fast Healthcare Interoperability Resources (FHIR) observations using CDE set/element identifiers as standardized semantic labels. This framework deploys CDE identifiers to specify radiology findings and attributes, providing consistent labels for radiology report concepts-diagnoses, recommendations, tabular/quantitative data-with built-in integration with RadLex, SNOMED CT, LOINC, and other ontologies. Observation structures fit within larger HL7 FHIR DiagnosticReport resources, providing output including both nuanced text and structured data. RESULTS: Labeling radiology findings as discrete data for interchange between systems requires two components: structure and semantics. CDE definitions provide semantic identifiers for findings and their component values. The FHIR observation resource specifies a structure for associating identifiers with radiology findings in the context of reports, with CDE-encoded observations referring to definitions for CDE identifiers in a central repository. The discussion includes an example of encoding pulmonary nodules on a chest CT as CDE-labeled observations, demonstrating the application of this framework to exchange findings throughout the imaging workflow, making imaging data available to downstream clinical systems. DISCUSSION: CDE-labeled observations establish a lingua franca for encoding, exchanging, and consuming radiology data at the level of individual findings, facilitating use throughout healthcare systems. IMPORTANCE: CDE-labeled FHIR observation objects can increase the value of radiology results by facilitating their use throughout patient care.


Asunto(s)
Elementos de Datos Comunes , Interoperabilidad de la Información en Salud , Semántica , Humanos , Sistemas de Información Radiológica/organización & administración , Sistemas de Información Radiológica/normas , Estándar HL7 , Inteligencia Artificial , Diagnóstico por Imagen , Registros Electrónicos de Salud
2.
J Imaging Inform Med ; 37(2): 899-908, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38315345

RESUMEN

The rapid growth of artificial intelligence (AI) and deep learning techniques require access to large inter-institutional cohorts of data to enable the development of robust models, e.g., targeting the identification of disease biomarkers and quantifying disease progression and treatment efficacy. The Observational Medical Outcomes Partnership Common Data Model (OMOP CDM) has been designed to accommodate a harmonized representation of observational healthcare data. This study proposes the Medical Imaging CDM (MI-CDM) extension, adding two new tables and two vocabularies to the OMOP CDM to address the structural and semantic requirements to support imaging research. The tables provide the capabilities of linking DICOM data sources as well as tracking the provenance of imaging features derived from those images. The implementation of the extension enables phenotype definitions using imaging features and expanding standardized computable imaging biomarkers. This proposal offers a comprehensive and unified approach for conducting imaging research and outcome studies utilizing imaging features.

3.
AJR Am J Roentgenol ; 222(4): e2329806, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38230904

RESUMEN

BACKGROUND. Examination protocoling is a noninterpretive task that increases radiologists' workload and can cause workflow inefficiencies. OBJECTIVE. The purpose of this study was to evaluate effects of an automated CT protocoling system on examination process times and protocol error rates. METHODS. This retrospective study included 317,597 CT examinations (mean age, 61.8 ± 18.1 [SD] years; male, 161,125; female, 156,447; unspecified sex, 25) from July 2020 to June 2022. A rules-based automated protocoling system was implemented institution-wide; the system evaluated all CT orders in the EHR and assigned a protocol or directed the order for manual radiologist protocoling. The study period comprised pilot (July 2020 to December 2020), implementation (January 2021 to December 2021), and postimplementation (January 2022 to June 2022) phases. Proportions of automatically protocoled examinations were summarized. Process times were recorded. Protocol error rates were assessed by counts of quality improvement (QI) reports and examination recalls and comparison with retrospectively assigned protocols in 450 randomly selected examinations. RESULTS. Frequency of automatic protocoling was 19,366/70,780 (27.4%), 68,875/163,068 (42.2%), and 54,045/83,749 (64.5%) in pilot, implementation, and postimplementation phases, respectively (p < .001). Mean (± SD) times from order entry to protocol assignment for automatically and manually protocoled examinations for emergency department examinations were 0.2 ± 18.2 and 2.1 ± 69.7 hours, respectively; mean inpatient examination times were 0.5 ± 50.0 and 3.5 ± 105.5 hours; and mean outpatient examination times were 361.7 ± 1165.5 and 1289.9 ± 2050.9 hours (all p < .001). Mean (± SD) times from order entry to examination completion for automatically and manually protocoled examinations for emergency department examinations were 2.6 ± 38.6 and 4.2 ± 73.0 hours, respectively (p < .001); for inpatient examinations were 6.3 ± 74.6 and 8.7 ± 109.3 hours (p = .001); and for outpatient examinations were 1367.2 ± 1795.8 and 1471.8 ± 2118.3 hours (p < .001). In the three phases, there were three, 19, and 25 QI reports and zero, one, and three recalls, respectively, for automatically protocoled examinations, versus nine, 19, and five QI reports and one, seven, and zero recalls for manually protocoled examinations. Retrospectively assigned protocols were concordant with 212/214 (99.1%) of automatically protocoled versus 233/236 (98.7%) of manually protocoled examinations. CONCLUSION. The automated protocoling system substantially reduced radiologists' protocoling workload and decreased times from order entry to protocol assignment and examination completion; protocol errors and recalls were infrequent. CLINICAL IMPACT. The system represents a solution for reducing radiologists' time spent performing noninterpretive tasks and improving care efficiency.


Asunto(s)
Tomografía Computarizada por Rayos X , Humanos , Femenino , Masculino , Estudios Retrospectivos , Persona de Mediana Edad , Tomografía Computarizada por Rayos X/métodos , Mejoramiento de la Calidad , Protocolos Clínicos , Flujo de Trabajo , Carga de Trabajo , Anciano , Adulto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...