1.
Phys Med Biol ; 69(11)2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38729180

RESUMEN

The design of prompt-gamma detectors necessitates numerous Monte Carlo simulations to precisely develop and optimize the detection stages in proton therapy. Alongside the advancement of MC simulations, various variance reduction methods have been explored to speed-up calculations. Among these techniques, track-length estimators are interesting scoring methods for achieving both speed and accuracy in Monte Carlo simulations of rare events. This paper introduces an extension of the GATE vpgTLE module that incorporates the prompt-gamma emission time, which is tagged from the proton tracking, enhancing its utility for studies focused on detector design and optimization that rely on time measurements. The results obtained from a clinical radiotherapy plan are presented. We demonstrate that the new vpgTLE tally with time tagging is accurate, except for certain prompt-gamma lines corresponding to long mean-life nuclei.


Asunto(s)
Rayos gamma , Método de Montecarlo , Terapia de Protones , Factores de Tiempo , Protones , Planificación de la Radioterapia Asistida por Computador/métodos
2.
EJNMMI Phys ; 11(1): 15, 2024 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-38316677

RESUMEN

BACKGROUND: In peptide receptor radionuclide therapy (PRRT), accurate quantification of kidney activity on post-treatment SPECT images paves the way for patient-specific treatment. Due to the limited spatial resolution of SPECT images, the partial volume effect (PVE) is a significant source of quantitative bias. In this study, we aimed to evaluate the performance and robustness of anatomy-based partial volume correction (PVC) algorithms to recover the accurate activity concentration of realistic kidney geometries on [Formula: see text]Lu SPECT images recorded under clinical conditions. METHODS: Based on the CT scan data from patients, three sets of fillable kidneys with surface-to-volume (S:V) ratios ranging from 1.5 to 2.8 cm-1, were 3D printed and attached in a IEC phantom. Quantitative [Formula: see text]Lu SPECT/CT acquisitions were performed on a GE Discovery NM CT 870 DR camera for the three modified IEC phantoms and for 6 different Target-To-Background ratios (TBRs: 2, 4, 6, 8, 10, 12). Two region-based (GTM and Labbé) and five voxel-based (GTM + MTC, Labbé + MTC, GTM + RBV, Labbé + RBV and IY) methods were evaluated with this data set. Additionally, the robustness of PVC methods to Point Spread Function (PSF) discrepancies, registration mismatches and background heterogeneity was evaluated. RESULTS: Without PVC, the average kidney RCs across all TBRs ranged from 0.66 ± 0.05 (smallest kidney) to 0.80 ± 0.03 (largest kidney). For a TBR of 12, all anatomy-based method were able to recover the kidneys activity concentration with an error < 6%. All methods result in a comparable decline in RC restoration with decreasing TBR. The Labbé method was the most robust against PSF and registration mismatches but was also the most sensitive to background heterogeneity. Among the voxel-based methods, MTC images were less uniform than RBV and IY images at the outer edge of high uptake areas (kidneys and spheres). CONCLUSION: Anatomy-based PVE correction allows for accurate SPECT quantification of the [Formula: see text]Lu activity concentration with realistic kidney geometries. Combined with recent progress in deep-learning algorithms for automatic anatomic segmentation of whole-body CT, these methods could be of particular interest for a fully automated OAR dosimetry pipeline with PVE correction.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...