Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Polymers (Basel) ; 15(14)2023 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-37514455

RESUMEN

This research paper aims to fabricate flexible PVA/Cs/TiO2 nanocomposite films consisting of polyvinyl alcohol (PVA), chitosan (Cs), and titanium oxide (TiO2) for application in energy storage devices. The samples were analyzed using X-ray diffraction (XRD), atomic force microscope (AFM), scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), and energy dispersive X-ray (EDX) techniques. The impact of TiO2 on the electrical impedance, conductivity, permittivity, and energy efficiency of the PVA/Cs was determined in a frequency range of 100 Hz to 5 GHz. The XRD, FTIR, and EDX results showed the successful fabrications of the PVA/Cs/TiO2. The SEM and AFM images illustrated that the TiO2 was loaded and distributed homogenously in PVA/Cs chains. In addition, the electrical conductivity was enhanced from 0.04 × 10-7 S.cm-1 of PVA/Cs to 0.25 × 10-7 S.cm-1 and 5.75 × 10-7 S.cm-1, respectively, for the composite PVA/Cs/0.01TiO2 and PVA/Cs/0.1TiO2, and the dielectric constant grew from 2.46 for PVA/Cs to 7.38 and 11.93, respectively. These results revealed that modifications were made to the produced films, paving the way for using the composite PVA/Cs/TiO2 films in different energy applications, such as electronic circuits and supercapacitors.

2.
Appl Radiat Isot ; 174: 109777, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34051528

RESUMEN

Auger emitting radioisotopes are of great interest in targeted radiotherapy because, once internalised in the tumour cells, they can deliver dose locally to the radiation sensitive targets, while not affecting surrounding cells. Geant4 is a Monte Carlo code widely used to characterise the physics mechanism at the basis of targeted radiotherapy. In this work, we benchmarked the modelling of the emission of Auger electrons in Geant4 deriving from the decay of 123I, 124I, 125I radionuclides against existing theoretical approaches. We also compared Geant4 against reference data in the case of 131Cs, which is of interest for brachytherapy. In the case of 125I and 131Cs, the simulation results are compared to experimental measurements as well. Good agreement was found between Geant4 and the reference data. As far as we know, this is the first study aimed to benchmark against experimental measurements the emission of Auger electrons in Geant4 for radiotherapy applications.


Asunto(s)
Benchmarking , Electrones , Radiofármacos/química , Método de Montecarlo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...