Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 101
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Bioact Mater ; 41: 553-563, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39246838

RESUMEN

Chronic bladder dysfunction due to bladder disease or trauma is detrimental to affected patients as it can lead to increased risk of upper urinary tract dysfunction. Current treatment options include surgical interventions that enlarge the bladder with autologous bowel tissue to alleviate pressure on the upper urinary tract. This highly invasive procedure, termed bladder augmentation enterocystoplasty (BAE), significantly increases the risk of patient morbidity and mortality due to the incompatibility between bowel and bladder tissue. Therefore, patients would significantly benefit from an alternative treatment strategy that can regenerate healthy tissue and restore overall bladder function. Previous research has demonstrated the potential of citrate-based scaffolds co-seeded with bone marrow-derived stem/progenitor cells as an alternative graft for bladder augmentation. Recognizing that contact guidance can potentially influence tissue regeneration, we hypothesized that microtopographically patterned scaffolds would modulate cell responses and improve overall quality of the regenerated bladder tissue. We fabricated microgrooved (MG) scaffolds using the citrate-based biomaterial poly (1,8-octamethylene-citrate-co-octanol) (POCO) and co-seeded them with human bone marrow-derived mesenchymal stromal cells (MSCs) and CD34+ hematopoietic stem/progenitor cells (HSPCs). MG POCO scaffolds supported MSC and HSPC attachment, and MSC alignment within the microgrooves. All scaffolds were characterized and assessed for bladder tissue regeneration in an established nude rat bladder augmentation model. In all cases, normal physiological function was maintained post-augmentation, even without the presence of stem/progenitor cells. Urodynamic testing at 4-weeks post-augmentation for all experimental groups demonstrated that bladder capacity increased and bladder compliance was normal. Histological evaluation of the regenerated tissue revealed that cell-seeded scaffolds restored normal bladder smooth muscle content and resulted in increased revascularization and peripheral nerve regeneration. The presence of microgrooves on the cell-seeded scaffolds increased microvasculature formation by 20 % and urothelial layer thickness by 25 % in the regenerating tissue. Thus, this work demonstrates that microtopography engineering can influence bladder tissue regeneration to improve overall anatomical structure and re-establish bladder physiology.

2.
Bioact Mater ; 41: 427-439, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39188380

RESUMEN

Approaches to regenerating bone often rely on integrating biomaterials and biological signals in the form of cells or cytokines. However, from a translational point of view, these approaches are challenging due to the sourcing and quality of the biologic, unpredictable immune responses, complex regulatory paths, and high costs. We describe a simple manufacturing process and a material-centric 3D-printed composite scaffold system (CSS) that offers distinct advantages for clinical translation. The CSS comprises a 3D-printed porous polydiolcitrate-hydroxyapatite composite elastomer infused with a polydiolcitrate-graphene oxide hydrogel composite. Using a micro-continuous liquid interface production 3D printer, we fabricate a precise porous ceramic scaffold with 60 wt% hydroxyapatite resembling natural bone. The resulting scaffold integrates with a thermoresponsive hydrogel composite in situ to fit the defect, which is expected to enhance surface contact with surrounding tissue and facilitate biointegration. The antioxidative properties of citrate polymers prevent long-term inflammatory responses. The CSS stimulates osteogenesis in vitro and in vivo. Within 4 weeks in a calvarial critical-sized bone defect model, the CSS accelerated ECM deposition (8-fold) and mineralized osteoid (69-fold) compared to the untreated. Through spatial transcriptomics, we demonstrated the comprehensive biological processes of CSS for prompt osseointegration. Our material-centric approach delivers impressive osteogenic properties and streamlined manufacturing advantages, potentially expediting clinical application for bone reconstruction surgeries.

3.
Res Sq ; 2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-39108474

RESUMEN

Composite cranial defects have individual functional and aesthetic ramifications, as well as societal burden, while posing significant challenges for reconstructive surgeons. Single-stage composite reconstruction of these deformities entail complex surgeries that bear many short- and long-term risks and complications. Current research on composite scalp-cranial defects is sparse and one-dimensional, often focusing solely on bone or skin. Thus, there is an unmet need for a simple, clinically relevant composite defect model in rodents, where there is a challenge in averting healing of the skin component via secondary intention. By utilizing a customizable (3D-printed) wound obturator, the scalp wound can be rendered non-healing for a long period (more than 6 weeks), with the cranial defect patent. The wound obturator shows minimal biotoxicity and will not cause severe endocranium-granulation adhesion. This composite defect model effectively slowed the scalp healing process and preserved the cranial defect, embodying the characteristics of a "chronic composite defect". In parallel, an autologous reconstruction model was established as the positive control. This positive control exhibited reproducible healing of the skin within 3 weeks with variable degrees of osseointegration, consistent with clinical practice. Both models provide a stable platform for subsequent research not only for composite tissue engineering and scaffold design but also for mechanistic studies of composite tissue healing.

4.
ACS Appl Mater Interfaces ; 16(34): 45422-45432, 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39102678

RESUMEN

Implantable polymeric biodegradable devices, such as biodegradable vascular scaffolds, cannot be fully visualized using standard X-ray-based techniques, compromising their performance due to malposition after deployment. To address this challenge, we describe a new radiopaque and photocurable liquid polymer-ceramic composite (mPDC-MoS2) consisting of methacrylated poly(1,12 dodecamethylene citrate) (mPDC) and molybdenum disulfide (MoS2) nanosheets. The composite was used as an ink with microcontinuous liquid interface production (µCLIP) to fabricate bioresorbable vascular scaffolds (BVS). Prints exhibited excellent crimping and expansion mechanics without strut failures and, importantly, with X-ray visibility in air and muscle tissue. Notably, MoS2 nanosheets displayed physical degradation over time in phosphate-buffered saline solution, suggesting the potential for producing radiopaque, fully bioresorbable devices. mPDC-MoS2 is a promising bioresorbable X-ray-visible composite material suitable for 3D printing medical devices, such as vascular scaffolds, that require noninvasive X-ray-based monitoring techniques for implantation and evaluation. This innovative biomaterial composite system holds significant promise for the development of biocompatible, fluoroscopically visible medical implants, potentially enhancing patient outcomes and reducing medical complications.


Asunto(s)
Disulfuros , Molibdeno , Impresión Tridimensional , Andamios del Tejido , Molibdeno/química , Disulfuros/química , Andamios del Tejido/química , Implantes Absorbibles , Polímeros/química , Materiales Biocompatibles/química , Citratos/química , Animales
5.
Sci Adv ; 10(23): eadk3081, 2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38848367

RESUMEN

Clinical outcomes for total-pancreatectomy followed by intraportal islet autotransplantation (TP-IAT) to treat chronic pancreatitis (CP) are suboptimal due to pancreas inflammation, oxidative stress during islet isolation, and harsh engraftment conditions in the liver's vasculature. We describe a thermoresponsive, antioxidant macromolecule poly(polyethylene glycol citrate-co-N-isopropylacrylamide) (PPCN) to protect islet redox status and function and to enable extrahepatic omentum islet engraftment. PPCN solution transitions from a liquid to a hydrogel at body temperature. Islets entrapped in PPCN and exposed to oxidative stress remain functional and support long-term euglycemia, in contrast to islets entrapped in a plasma-thrombin biologic scaffold. In the nonhuman primate (NHP) omentum, PPCN is well-tolerated and mostly resorbed without fibrosis at 3 months after implantation. In NHPs, autologous omentum islet transplantation using PPCN restores normoglycemia with minimal exogenous insulin requirements for >100 days. This preclinical study supports TP-IAT with PPCN in patients with CP and highlights antioxidant properties as a mechanism for islet function preservation.


Asunto(s)
Trasplante de Islotes Pancreáticos , Islotes Pancreáticos , Epiplón , Estrés Oxidativo , Trasplante de Islotes Pancreáticos/métodos , Epiplón/metabolismo , Animales , Islotes Pancreáticos/metabolismo , Islotes Pancreáticos/efectos de los fármacos , Estrés Oxidativo/efectos de los fármacos , Ácido Cítrico/farmacología , Humanos , Antioxidantes/farmacología , Pancreatitis Crónica/metabolismo , Pancreatitis Crónica/cirugía , Pancreatitis Crónica/patología , Polietilenglicoles/química , Polietilenglicoles/farmacología , Masculino , Transición de Fase
6.
Adv Mater ; 36(32): e2402871, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38801111

RESUMEN

Citrate-based biodegradable polymers have emerged as a distinctive biomaterial platform with tremendous potential for diverse medical applications. By harnessing their versatile chemistry, these polymers exhibit a wide range of material and bioactive properties, enabling them to regulate cell metabolism and stem cell differentiation through energy metabolism, metabonegenesis, angiogenesis, and immunomodulation. Moreover, the recent US Food and Drug Administration (FDA) clearance of the biodegradable poly(octamethylene citrate) (POC)/hydroxyapatite-based orthopedic fixation devices represents a translational research milestone for biomaterial science. POC joins a short list of biodegradable synthetic polymers that have ever been authorized by the FDA for use in humans. The clinical success of POC has sparked enthusiasm and accelerated the development of next-generation citrate-based biomaterials. This review presents a comprehensive, forward-thinking discussion on the pivotal role of citrate chemistry and metabolism in various tissue regeneration and on the development of functional citrate-based metabotissugenic biomaterials for regenerative engineering applications.


Asunto(s)
Materiales Biocompatibles , Ácido Cítrico , Humanos , Ácido Cítrico/química , Materiales Biocompatibles/química , Animales , Ingeniería de Tejidos/métodos , Polímeros/química , Durapatita/química , Durapatita/metabolismo
7.
Proc Natl Acad Sci U S A ; 121(14): e2400868121, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38547066

RESUMEN

Partial cystectomy procedures for urinary bladder-related dysfunction involve long recovery periods, during which urodynamic studies (UDS) intermittently assess lower urinary tract function. However, UDS are not patient-friendly, they exhibit user-to-user variability, and they amount to snapshots in time, limiting the ability to collect continuous, longitudinal data. These procedures also pose the risk of catheter-associated urinary tract infections, which can progress to ascending pyelonephritis due to prolonged lower tract manipulation in high-risk patients. Here, we introduce a fully bladder-implantable platform that allows for continuous, real-time measurements of changes in mechanical strain associated with bladder filling and emptying via wireless telemetry, including a wireless bioresorbable strain gauge validated in a benchtop partial cystectomy model. We demonstrate that this system can reproducibly measure real-time changes in a rodent model up to 30 d postimplantation with minimal foreign body response. Studies in a nonhuman primate partial cystectomy model demonstrate concordance of pressure measurements up to 8 wk compared with traditional UDS. These results suggest that our system can be used as a suitable alternative to UDS for long-term postoperative bladder recovery monitoring.


Asunto(s)
Vejiga Urinaria , Infecciones Urinarias , Animales , Humanos , Vejiga Urinaria/cirugía , Urodinámica/fisiología , Prótesis e Implantes , Cistectomía
8.
Adv Sci (Weinh) ; 11(27): e2305562, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38350724

RESUMEN

Conductive polymers (CPs) are widely studied for their ability to influence a myriad of tissue systems. While their mixed ionic/electronic conductivity is commonly considered the primary driver of these benefits, the mechanisms by which CPs influence cell fate remain unclear. In this study, CP-biomaterial interactions are investigated using collagen, due to its widespread prevalence throughout the body and in tissue engineering constructs. Collagen is functionalized with both electrostatically and covalently bound derivatives of the CP poly(3,4-ethylenedioxythiophene) (PEDOT) doped via backbone-tethered sulfonate groups, which enable high solubility and loading to the collagen biomatrix. Intrinsically doped scaffolds are compared to those incorporated with a commercially available PEDOT formulation, which is complexed with polyanionic polystyrene sulfonate (PSS). Low loadings of intrinsically doped PEDOT do not increase substrate conductivity compared to collagen alone, enabling separate investigation into CP loading and conductivity. Interestingly, higher PEDOT loading bolsters human mesenchymal stromal (hMSC) cell gene expression of Oct-4 and NANOG, which are key transcription factors regulating cell stemness. Conductive collagen composites with commercial PEDOT:PSS do not significantly affect the expression of these transcription factors in hMSCs. Furthermore, it is demonstrated that PEDOT regulates cellular fate independently from physical changes to the material but directly to the loading of the polymer.


Asunto(s)
Compuestos Bicíclicos Heterocíclicos con Puentes , Colágeno , Polímeros , Compuestos Bicíclicos Heterocíclicos con Puentes/farmacología , Compuestos Bicíclicos Heterocíclicos con Puentes/química , Polímeros/química , Colágeno/metabolismo , Colágeno/química , Humanos , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Ingeniería de Tejidos/métodos , Andamios del Tejido/química , Poliestirenos/química , Células Madre Mesenquimatosas/efectos de los fármacos , Células Madre Mesenquimatosas/metabolismo , Conductividad Eléctrica
9.
PNAS Nexus ; 3(2): pgae038, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38344009

RESUMEN

To date, there are no efficacious translational solutions for end-stage urinary bladder dysfunction. Current surgical strategies, including urinary diversion and bladder augmentation enterocystoplasty (BAE), utilize autologous intestinal segments (e.g. ileum) to increase bladder capacity to protect renal function. Considered the standard of care, BAE is fraught with numerous short- and long-term clinical complications. Previous clinical trials employing tissue engineering approaches for bladder tissue regeneration have also been unable to translate bench-top findings into clinical practice. Major obstacles still persist that need to be overcome in order to advance tissue-engineered products into the clinical arena. These include scaffold/bladder incongruencies, the acquisition and utility of appropriate cells for anatomic and physiologic tissue recapitulation, and the choice of an appropriate animal model for testing. In this study, we demonstrate that the elastomeric, bladder biomechanocompatible poly(1,8-octamethylene-citrate-co-octanol) (PRS; synthetic) scaffold coseeded with autologous bone marrow-derived mesenchymal stem cells and CD34+ hematopoietic stem/progenitor cells support robust long-term, functional bladder tissue regeneration within the context of a clinically relevant baboon bladder augmentation model simulating bladder trauma. Partially cystectomized baboons were independently augmented with either autologous ileum or stem-cell-seeded small-intestinal submucosa (SIS; a commercially available biological scaffold) or PRS grafts. Stem-cell synergism promoted functional trilayer bladder tissue regeneration, including whole-graft neurovascularization, in both cell-seeded grafts. However, PRS-augmented animals demonstrated fewer clinical complications and more advantageous tissue characterization metrics compared to ileum and SIS-augmented animals. Two-year study data demonstrate that PRS/stem-cell-seeded grafts drive bladder tissue regeneration and are a suitable alternative to BAE.

10.
Adv Mater ; 36(6): e2306326, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38043945

RESUMEN

Regenerative medicine aims to restore tissue and organ function without the use of prosthetics and permanent implants. However, achieving this goal has been elusive, and the field remains mostly an academic discipline with few products widely used in clinical practice. From a materials science perspective, barriers include the lack of proregenerative biomaterials, a complex regulatory process to demonstrate safety and efficacy, and user adoption challenges. Although biomaterials, particularly biodegradable polymers, can play a major role in regenerative medicine, their suboptimal mechanical and degradation properties often limit their use, and they do not support inherent biological processes that facilitate tissue regeneration. As of 2020, nine synthetic biodegradable polymers used in medical devices are cleared or approved for use in the United States of America. Despite the limitations in the design, production, and marketing of these devices, this small number of biodegradable polymers has dominated the resorbable medical device market for the past 50 years. This perspective will review the history and applications of biodegradable polymers used in medical devices, highlight the need and requirements for regenerative biomaterials, and discuss the path behind the recent successful introduction of citrate-based biomaterials for manufacturing innovative medical products aimed at improving the outcome of musculoskeletal surgeries.


Asunto(s)
Materiales Biocompatibles , Ingeniería de Tejidos , Materiales Biocompatibles/farmacología , Ácido Cítrico , Medicina Regenerativa , Polímeros , Citratos
11.
bioRxiv ; 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37961681

RESUMEN

Implantable polymeric biodegradable devices, such as biodegradable vascular stents or scaffolds, cannot be fully visualized using standard X-ray-based techniques, compromising their performance due to malposition after deployment. To address this challenge, we describe composites of methacrylated poly(1,12 dodecamethylene citrate) (mPDC) and MoS2 nanosheets to fabricate novel X-ray visible radiopaque and photocurable liquid polymer-ceramic composite (mPDC-MoS2). The composite was used as an ink with micro continuous liquid interface production (µCLIP) to fabricate bioresorbable vascular scaffolds (BVS). Prints exhibited excellent crimping and expansion mechanics without strut failures and, importantly, required X-ray visibility in air and muscle tissue. Notably, MoS2 nanosheets displayed physical degradation over time in a PBS environment, indicating the potential for producing bioresorbable devices. mPDC-MoS2 is a promising bioresorbable X-ray-visible composite material suitable for 3D printing medical devices, particularly vascular scaffolds or stents, that require non-invasive X-ray-based monitoring techniques for implantation and evaluation. This innovative composite system holds significant promise for the development of biocompatible and highly visible medical implants, potentially enhancing patient outcomes and reducing medical complications.

12.
Artículo en Inglés | MEDLINE | ID: mdl-37861912

RESUMEN

Peripheral artery disease (PAD) is a prevalent cardiovascular disease with risks of limb loss. Our objective is to establish an autologous cell source for vascular regeneration to achieve limb salvage in PAD. Six PAD patients (age 50-80) were enrolled with their peripheral blood collected to derive vascular endothelial cells (ECs) with two different approaches: (1) endothelial progenitor cell (EPC) approach and (2) induced pluripotent stem cell (iPSC) approach. The iPSC approach successfully generated patient-specific ECs for all PAD patients, while the EPC approach did not yield any colony-forming ECs in any of the patients. The patient-derived iPSC-ECs expressed endothelial markers and exhibited endothelial functions. However, elevated inflammatory status with VCAM-1 expression was observed in the patient-derived cells. Pharmacological treatment with resveratrol resulted in patient-specific responses in cell viability and VCAM-1 expression. Our study demonstrates the potential of iPSC-ECs for autologous regenerative therapy in PAD, offering promise for personalized treatments for ischemic PAD. Our study establishes autologous endothelial cells from induced pluripotent stem cells as a cellular resource for regenerative treatments in peripheral artery disease.

13.
Adv Healthc Mater ; 12(28): e2301280, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37407030

RESUMEN

Diabetic foot ulcers are chronic wounds that affect millions and increase the risk of amputation and mortality, highlighting the critical need for their early detection. Recent demonstrations of wearable sensors enable real-time wound assessment, but they rely on bulky electronics, making them difficult to interface with wounds. Herein, a miniaturized, wireless, battery-free wound monitor that measures lactate in real-time and seamlessly integrates with bandages for conformal attachment to the wound bed is introduced. Lactate is selected due to its multifaceted role in initiating healing. Studies in healthy and diabetic mice reveal distinct lactate profiles for normal and impaired healing wounds. A mathematical model based on the sensor data predicts wound closure rate within the first 3 days post-injury with ≈76% accuracy, which increases to ≈83% when pH is included. These studies underscore the significance of monitoring biomarkers during the inflammation phase, which can offer several benefits, including short-term use of wound monitors and their easy removal, resulting in lower risks of injury and infection at the wound site. Improvements in prediction accuracy can be achieved by designing mathematical models that build on multiple wound parameters such as pro-inflammatory and metabolic markers. Achieving this goal will require designing multi-analyte wound monitors.


Asunto(s)
Diabetes Mellitus Experimental , Pie Diabético , Animales , Ratones , Cicatrización de Heridas , Vendajes , Pie Diabético/diagnóstico , Lactatos
14.
Adv Healthc Mater ; 12(31): e2301683, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37327023

RESUMEN

Impaired wound healing is a common complication for diabetic patients and effective diabetic wound management remains a clinical challenge. Furthermore, a significant problem that contributes to patient morbidity is the suboptimal quality of healed skin, which often leads to reoccurring chronic skin wounds. Herein, a novel compound and biomaterial building block, panthenol citrate (PC), is developed. It has interesting fluorescence and absorbance properties, and it is shown that PC can be used in soluble form as a wash solution and as a hydrogel dressing to address impaired wound healing in diabetes. PC exhibits antioxidant, antibacterial, anti-inflammatory, and pro-angiogenic properties, and promotes keratinocyte and dermal fibroblast migration and proliferation. When applied in a splinted excisional wound diabetic rodent model, PC improves re-epithelialization, granulation tissue formation, and neovascularization. It also reduces inflammation and oxidative stress in the wound environment. Most importantly, it improves the regenerated tissue quality with enhanced mechanical strength and electrical properties. Therefore, PC could potentially improve wound care management for diabetic patients and play a beneficial role in other tissue regeneration applications.


Asunto(s)
Materiales Biocompatibles , Diabetes Mellitus Experimental , Animales , Humanos , Materiales Biocompatibles/farmacología , Ácido Cítrico/farmacología , Diabetes Mellitus Experimental/tratamiento farmacológico , Cicatrización de Heridas , Citratos
15.
Nat Biomed Eng ; 7(11): 1514-1529, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37308586

RESUMEN

Topographical cues on cells can, through contact guidance, alter cellular plasticity and accelerate the regeneration of cultured tissue. Here we show how changes in the nuclear and cellular morphologies of human mesenchymal stromal cells induced by micropillar patterns via contact guidance influence the conformation of the cells' chromatin and their osteogenic differentiation in vitro and in vivo. The micropillars impacted nuclear architecture, lamin A/C multimerization and 3D chromatin conformation, and the ensuing transcriptional reprogramming enhanced the cells' responsiveness to osteogenic differentiation factors and decreased their plasticity and off-target differentiation. In mice with critical-size cranial defects, implants with micropillar patterns inducing nuclear constriction altered the cells' chromatin conformation and enhanced bone regeneration without the need for exogenous signalling molecules. Our findings suggest that medical device topographies could be designed to facilitate bone regeneration via chromatin reprogramming.


Asunto(s)
Células Madre Mesenquimatosas , Osteogénesis , Ratones , Humanos , Animales , Cromatina , Constricción , Regeneración Ósea
16.
Sci Adv ; 9(8): eade4687, 2023 02 22.
Artículo en Inglés | MEDLINE | ID: mdl-36812305

RESUMEN

Chronic wounds, particularly those associated with diabetes mellitus, represent a growing threat to public health, with additional notable economic impacts. Inflammation associated with these wounds leads to abnormalities in endogenous electrical signals that impede the migration of keratinocytes needed to support the healing process. This observation motivates the treatment of chronic wounds with electrical stimulation therapy, but practical engineering challenges, difficulties in removing stimulation hardware from the wound site, and absence of means to monitor the healing process create barriers to widespread clinical use. Here, we demonstrate a miniaturized wireless, battery-free bioresorbable electrotherapy system that overcomes these challenges. Studies based on a splinted diabetic mouse wound model confirm the efficacy for accelerated wound closure by guiding epithelial migration, modulating inflammation, and promoting vasculogenesis. Changes in the impedance provide means for tracking the healing process. The results demonstrate a simple and effective platform for wound site electrotherapy.


Asunto(s)
Diabetes Mellitus , Terapia por Estimulación Eléctrica , Ratones , Animales , Implantes Absorbibles , Impedancia Eléctrica , Cicatrización de Heridas , Modelos Animales de Enfermedad , Inflamación
17.
Adv Healthc Mater ; 11(23): e2201955, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36168854

RESUMEN

Bioresorbable stents (BRS) hold great promise for the treatment of many life-threatening luminal diseases. Tracking and monitoring of stents in vivo is critical for avoiding their malposition and inadequate expansion, which often leads to complications and stent failure. However, obtaining high X-ray visibility of polymeric BRS has been challenging because of their intrinsic radiolucency. This study demonstrates the use of photopolymerization-based 3D printing technique to fabricate radiopaque BRS by incorporating iodixanol, a clinical contrast agent, into a bioresorbable citrate-based polymer ink. The successful volumetric dispersion of the iodixanol through the 3D-printing process confers strong X-ray visibility of the produced BRS. Following in vitro degradation, the 3D-printed BRS embedded in chicken muscle maintains high X-ray visibility for at least 4 weeks. Importantly, the 3D-printed radiopaque BRS demonstrates good cytocompatibility and strong mechanical competence in crimping and expansion, which is essential for minimally invasive stent deployment. In addition, it is found that higher loading concentrations of iodixanol, e.g. 10 wt.%, results in more strut fractures in stent crimping and expansion. To conclude, this study introduces a facile strategy to fabricate radiopaque BRS through the incorporation of iodixanol in the 3D printing process, which could potentially increase the clinical success of BRS.

18.
Macromol Biosci ; 22(8): e2200103, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35596668

RESUMEN

3D-printed hydrogel scaffolds functionalized with conductive polymers have demonstrated significant potential in regenerative applications for their structural tunability, physiochemical compatibility, and electroactivity. Controllably generating conductive hydrogels with fine features, however, has proven challenging. Here, micro-continuous liquid interface production (µCLIP) method is utilized to 3D print poly(2-hydroxyethyl methacrylate) (pHEMA) hydrogels. With a unique in-situ polymerization approach, a sulfonated monomer is first incorporated into the hydrogel matrix and subsequently polymerized into a conjugated polyelectrolyte, poly(4-(2,3-dihydro-thieno[3,4-b][1,4]dioxin-2-ylmethoxy)-butane-1 sulfonic acid sodium salt (PEDOT-S). Rod structures are fabricated at different crosslinking levels to investigate PEDOT-S incorporation and its effect on bulk hydrogel electronic and mechanical properties. After demonstrating that PEDOT-S does not significantly compromise the structures of the bulk material, pHEMA scaffolds are fabricated via µCLIP with features smaller than 100 µm. Scaffold characterization confirms PEDOT-S incorporation bolstered conductivity while lowering overall modulus. Finally, C2C12 myoblasts are seeded on PEDOT-pHEMA structures to verify cytocompatibility and the potential of this material in future regenerative applications. PEDOT-pHEMA scaffolds promote increased cell viability relative to their non-conductive counterparts and differentially influence cell organization. Taken together, this study presents a promising new approach for fabricating complex conductive hydrogel structures for regenerative applications.


Asunto(s)
Hidrogeles , Polihidroxietil Metacrilato , Conductividad Eléctrica , Hidrogeles/química , Hidrogeles/farmacología , Mioblastos , Impresión Tridimensional
19.
Nat Nanotechnol ; 17(3): 319-330, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35039683

RESUMEN

Standard oral rapamycin (that is, Rapamune) administration is plagued by poor bioavailability and broad biodistribution. Thus, this pleotropic mammalian target of rapamycin (mTOR) inhibitor has a narrow therapeutic window and numerous side effects and provides inadequate protection to transplanted cells and tissues. Furthermore, the hydrophobicity of rapamycin limits its use in parenteral formulations. Here, we demonstrate that subcutaneous delivery via poly(ethylene glycol)-b-poly(propylene sulfide) polymersome nanocarriers significantly alters rapamycin's cellular biodistribution to repurpose its mechanism of action for tolerance, instead of immunosuppression, and minimize side effects. While oral rapamycin inhibits T cell proliferation directly, subcutaneously administered rapamycin-loaded polymersomes modulate antigen presenting cells in lieu of T cells, significantly improving maintenance of normoglycemia in a clinically relevant, major histocompatibility complex-mismatched, allogeneic, intraportal (liver) islet transplantation model. These results demonstrate the ability of a rationally designed nanocarrier to re-engineer the immunosuppressive mechanism of a drug by controlling cellular biodistribution.


Asunto(s)
Trasplante de Células Madre Hematopoyéticas , Trasplante de Islotes Pancreáticos , Inmunosupresores/farmacología , Sirolimus/farmacología , Distribución Tisular
20.
Regen Eng Transl Med ; 8(1): 32-42, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-33786367

RESUMEN

Abstract: Poly(ethylene glycol) (PEG) is a nontoxic, hydrophilic polymer that is often covalently attached to proteins, drugs, tissues, or materials; a procedure commonly referred to as PEGylation. PEGylation improves solubility, circulation time, and reduces immunogenicity of therapeutic molecules. Currently, there are 21 PEGylated drugs approved by the Food and Drug Administration (FDA), and more in the developmental stage. In addition to the polymer's applications in the clinic, PEG is widely used as a solvent and emulsifying agent in the formulation of cosmetics, cleaning, and personal care products. Due to the ubiquitous presence of the polymer in everyday products, patients can develop antibodies against PEG (αPEG Abs) that can be problematic when a PEGylated drug is administered. These αPEG Abs can provoke hypersensitivity reactions, accelerated drug clearance, and decreased therapeutic efficacy. Herein, we review how the prevalence of PEG in everyday products has induced αPEG Abs within the general public as well as the effect of these Abs on the performance of PEGylated therapeutics. We will focus on clinical manifestations following the administration of PEGylated drugs. Lay Summary: Poly(ethylene glycol) (PEG) is a polymer found in products including cosmetics, personal care products, cleaning agents, medicine, and food. Due to the prevalence of PEG, people can develop antibodies (αPEG Abs) against the polymer, which recognize PEG as foreign. Of note, PEG is frequently incorporated into drug formulations to improve therapeutic efficacy. Complications can arise when a patient receiving a PEGylated drug has previously developed αPEG Abs from interactions with PEG in everyday products. The presence of high concentrations of αPEG Abs in blood can result in decreased treatment efficacy and allergic reactions to a wide range of therapeutics.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...