Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Radiol Med ; 126(4): 544-552, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33200307

RESUMEN

INTRODUCTION: Chest computed tomography (CT) examinations are performed routinely in some cystic fibrosis (CF) centers in order to evaluate lung disease progression in CF patients. Continuous CT technological advancement in theory could allows a lower radiation exposure of CF patients during chest CT examinations without an image quality reduction, and this could become increasingly important over time in order to reduce the cumulative radiation dose effects given the continuous increase of CF patients predicted median survival. OBJECTIVE: The aim of this study was to compare objective and subjective image quality and radiation dose between low-dose chest CT examinations performed in adult CF patients using a third-generation DSCT scanner and a 64-slices single-source CT (SSCT) scanner. MATERIALS AND METHODS: Between January 2016 and August 2019, 81 CF patients underwent low-dose chest CT examinations using both a 64-slices SSCT scanner (2016-2017) and a third-generation DSCT scanner (2018-2019). Objective image noise standard deviation (INSD), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), overall subjective image quality (OSIQ), subjective image noise (SIN), subjective evaluation of streaking artifacts (SA), movement artifacts (MA) and edge resolution (ER), dose-length product (DLP), volume computed tomography dose index (CTDIvol) and effective radiation dose (ERD) were compared between DSCT and SSCT examinations. DSCT examinations consisted in spiral inspiratory end expiratory acquisitions. SSCT examinations consisted in spiral inspiratory acquisitions and five axial expiratory ones. RESULTS: DSCT protocol showed statistically significant lower spiral inspiratory phase mean DLP, CTDIvol and ERD than SSCT protocol, with a 25% DLP, CTDIvol and ERD reduction. DSCT protocol showed statistically significant higher overall (inspiratory and expiratory phases) mean DLP, CTDIvol and ERD than SSCT protocol, with a 40% DLP, CTDIvol and ERD increase. Objective image quality (INSD, SNR and CNR) and SIN differences were not statistically significant, but subjective evaluation of DSCT images showed statistically significant better OSIQ and ER, as well as statistically significant lower SA and MA with respect to SSCT images. CONCLUSIONS: To our knowledge, this is the first study evaluating chest CT image quality and radiation dose in adult CF patients using a third-generation DSCT scanner, and it showed that technological advancements could be used in order to reduce radiation exposure of volumetric examinations. The spiral inspiratory dose reduction can be obtained with concomitant improvements in subjective image quality with comparable objective quality. This will probably allow a wider use of this imaging modality in order to assess bronchiectasis and will probably foster spiral expiratory acquisition for small airways disease evaluation.


Asunto(s)
Fibrosis Quística/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Dosis de Radiación , Adulto , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
4.
Pediatr Rep ; 4(3): e32, 2012 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-25396037

RESUMEN

Progress in medical and scientific research has increased the chances of survival for young patients with congenital diseases, children who, in the past, would not have had any chance of survival. Nowadays, congenital diseases can be treated with appropriate replacement therapies. These treatments can be difficult to administer in young patients because of the high frequency of administration (sometimes more than a dose per week), the use of intravenous infusion and the long-term or life-term requirement.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA