Resultados 1 - 20 de 123
Filtrar
1.
Knee Surg Sports Traumatol Arthrosc ; 30(7): 2259-2266, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34665300

RESUMEN

PURPOSE: Meniscal surgery is one of the most common orthopaedic surgical interventions. Total meniscus replacements have been proposed as a solution for patients with irreparable meniscal injuries. Reliable fixation is crucial for the success and functionality of such implants. The aim of this study was to characterise an interference screw fixation system developed for a novel fibre-matrix-reinforced synthetic total meniscus replacement in an ovine cadaveric model. METHODS: Textile straps were tested in tension to failure (n = 15) and in cyclic tension (70-220 N) for 1000 cycles (n = 5). The textile strap-interference screw fixation system was tested in 4.5 mm-diameter single anterior and double posterior tunnels in North of England Mule ovine tibias aged > 2 years using titanium alloy (Ti6Al4Va) and polyether-ether-ketone (PEEK) screws (n ≥ 5). Straps were preconditioned, dynamically loaded for 1000 cycles in tension (70-220 N), the fixation slippage under cyclic loading was measured, and then pulled to failure. RESULTS: Strap stiffness was at least 12 times that recorded for human meniscal roots. Strap creep strain at the maximum load (220 N) was 0.005 following 1000 cycles. For all tunnels, pull-out failure resulted from textile strap slippage or bone fracture rather than strap rupture, which demonstrated that the textile strap was comparatively stronger than the interference screw fixation system. Pull-out load (anterior 544 ± 119 N; posterior 889 ± 157 N) was comparable to human meniscal root strength. Fixation slippage was within the acceptable range for anterior cruciate ligament graft reconstruction (anterior 1.9 ± 0.7 mm; posterior 1.9 ± 0.5 mm). CONCLUSION: These findings show that the textile attachment-interference screw fixation system provides reliable fixation for a novel ovine meniscus implant, supporting progression to in vivo testing. This research provides a baseline for future development of novel human meniscus replacements, in relation to attachment design and fixation methods. The data suggest that surgical techniques familiar from ligament reconstruction may be used for the fixation of clinical meniscal prostheses.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior , Menisco , Animales , Ligamento Cruzado Anterior/cirugía , Reconstrucción del Ligamento Cruzado Anterior/métodos , Fenómenos Biomecánicos , Tornillos Óseos , Humanos , Menisco/cirugía , Ovinos , Tibia/cirugía
2.
J Biomech ; 73: 153-160, 2018 05 17.
Artículo en Inglés | MEDLINE | ID: mdl-29622481

RESUMEN

Pre-clinical, bench-top assessment of Total Knee Replacements (TKR) can provide information about the inherent constraint provided by a TKR, which does not depend on the condition of the patient undergoing the arthroplasty. However little guidance is given by the ASTM standard on test configurations such as medial-lateral (M:L) loading distribution, flexion angle or restriction of secondary motions. Using a purpose built rig for a materials testing machine, four TKRs currently in widespread clinical use, including medial-pivot and symmetrical condyle types, were tested for anterior-posterior translational constraint. Compressive joint loads from 710 to 2000 N, and a range of medial-lateral (M:L) load distributions, from 70:30% to 30:70% M:L, were applied at different flexion angles with secondary motions unconstrained. It was found that TKA constraint was significantly less at 60 and 90° flexion than at 0°, whilst increasing the compressive joint load increased the force required to translate the tibia to limits of AP constraint at all flexion angles tested. Additionally when M:L load distribution was shifted medially, a coupled internal rotation was observed with anterior translation and external rotation with posterior translation. This paper includes some recommendations for future development of pre-clinical testing methods.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Fenómenos Mecánicos , Cadáver , Humanos , Articulación de la Rodilla/cirugía , Ensayo de Materiales , Rotación , Tibia/cirugía
3.
Foot Ankle Surg ; 24(3): 259-263, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29409249

RESUMEN

BACKGROUND: The first metatarsophalangeal joint may be fused in order to treat arthritis or instability. The use of shape-memory staples for fixation is well recognised, but little work has been done into the optimal configuration of staples. METHODS: The structural behaviour of first metatarsophalangeal joint (MTPJ) arthrodeses using shape-memory staples or crossed screws was studied using cadaveric porcine joints. Five fixation configurations were tested: single vertical or horizontal staple, paired staples in dorsal-medial configuration (0-90° to the sagittal plane), paired staples in oblique orthogonal configuration (45-135°); or two crossed screws. Specimens were loaded in cyclical dorsiflexion for 1000 cycles. Plantar gapping and shearing were measured. Specimens were then loaded to failure. RESULTS: Cyclic testing caused more shear in the 45-135° staples than the crossed screws (1.0mm±0.5mm compared to 0.14mm±0.4mm, p<0.01). No significant difference was found in plantar gap formation. Single vertical and horizontal single staples failed at 15N and 19. CONCLUSIONS: N, respectively. Paired 0-90° staples failed at 43N±9N, significantly lower than the 45-135° staples (141N±25N; p<0.001) and crossed screws (180N±67N; p<0.001). There was no significant difference between the 45-135° staples and crossed screws. Screws failed by sudden cortical fracture; staples displayed gradual pull-out and shearing. First MTPJ arthrodeses fixed with single staples are not recommended. Arthrodeses fixed with staples at 0-90° to the sagittal plane were significantly less strong than two crossed screws. However, positioning oblique staples at 45-135° significantly improved stability, creating a construct as strong as, crossed screws. None of the constructs was strong enough for immediate weight bearing.


Asunto(s)
Artritis/cirugía , Artrodesis/instrumentación , Tornillos Óseos , Articulación Metatarsofalángica/cirugía , Suturas , Soporte de Peso/fisiología , Animales , Artritis/fisiopatología , Fenómenos Biomecánicos , Modelos Animales de Enfermedad , Diseño de Equipo , Articulación Metatarsofalángica/fisiopatología , Porcinos
4.
Med Eng Phys ; 47: 210-213, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28651855

RESUMEN

This paper describes the quantitative assessment of a robotic testing platform, consisting of an industrial robot and a universal force-moment sensor, via the design of fixtures used to hold the tibia and femur of cadaveric knees. This platform was used to study the contributions of different soft tissues and the ability of implants and reconstruction surgeries to restore normal joint functions, in previously published literature. To compare different conditions of human joints, it is essential to reposition specimens with high precision after they have been removed for a surgical procedure. Methods and experiments carried out to determine the pose repeatability and measure errors in repositioning specimens are presented. This was achieved using an optical tracking system (fusion Track 500, Atracsys Switzerland) to measure the position and orientation of bespoke rigid body markers attached to the tibial and femoral pots after removing and reinstalling them inside the rigs. The pose repeatability was then evaluated by controlling the robotic platform to move a knee joint repeatedly to/from a given pose while tracking the position and orientation of a rigid body marker attached to the tibial fixture. The results showed that the proposed design ensured a high repeatability in repositioning the pots with standard deviations for the computed distance and angle between the pots at both ends of the joint equal to 0.1mm, 0.01mm, 0.13° and 0.03° for the tibial and femoral fixtures respectively. Therefore, it is possible to remove and re-setup a joint with high precision. The results also showed that the errors in repositioning the robotic platform (that is: specimen path repeatability) were 0.11mm and 0.12°, respectively.


Asunto(s)
Articulaciones/fisiología , Posicionamiento del Paciente/métodos , Postura/fisiología , Rango del Movimiento Articular/fisiología , Robótica/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
J Mech Behav Biomed Mater ; 50: 277-89, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26164218

RESUMEN

Bone substitute composite materials with poly(L-lactide-co-glycolide) (PLGA) matrices and four different bioactive fillers: CaCO3, hydroxyapatite (HA), 45S5 Bioglass(®) (45S5 BG), and ICIE4 bioactive glass (a lower sodium glass than 45S5 BG) were produced via melt blending, extrusion and moulding. The viscoelastic, mechanical and thermal properties, and the molecular weight of the matrix were measured. Thermogravimetric analysis evaluated the effect of filler composition on the thermal degradation of the matrix. Bioactive glasses caused premature degradation of the matrix during processing, whereas CaCO3 or HA did not. All composites, except those with 45S5 BG, had similar mechanical strength and were stiffer than PLGA alone in compression, whilst all had a lower tensile strength. Dynamic mechanical analysis demonstrated an increased storage modulus (E') in the composites (other than the 45S5 BG filled PLGA). The effect of water uptake and early degradation was investigated by short-term in vitro aging in simulated body fluid, which indicated enhanced water uptake over the neat polymer; bioactive glass had the greatest water uptake, causing matrix plasticization. These results enable a direct comparison between bioactive filler type in poly(α-hydroxyester) composites, and have implications when selecting a composite material for eventual application in bone substitution.


Asunto(s)
Sustitutos de Huesos/química , Ácido Láctico/química , Fenómenos Mecánicos , Ácido Poliglicólico/química , Temperatura , Materiales Biomiméticos/química , Líquidos Corporales , Ensayo de Materiales , Peso Molecular , Copolímero de Ácido Poliláctico-Ácido Poliglicólico , Factores de Tiempo
6.
Bone Joint J ; 97-B(4): 484-91, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25820886

RESUMEN

In this in vitro study of the hip joint we examined which soft tissues act as primary and secondary passive rotational restraints when the hip joint is functionally loaded. A total of nine cadaveric left hips were mounted in a testing rig that allowed the application of forces, torques and rotations in all six degrees of freedom. The hip was rotated throughout a complete range of movement (ROM) and the contributions of the iliofemoral (medial and lateral arms), pubofemoral and ischiofemoral ligaments and the ligamentum teres to rotational restraint was determined by resecting a ligament and measuring the reduced torque required to achieve the same angular position as before resection. The contribution from the acetabular labrum was also measured. Each of the capsular ligaments acted as the primary hip rotation restraint somewhere within the complete ROM, and the ligamentum teres acted as a secondary restraint in high flexion, adduction and external rotation. The iliofemoral lateral arm and the ischiofemoral ligaments were primary restraints in two-thirds of the positions tested. Appreciation of the importance of these structures in preventing excessive hip rotation and subsequent impingement/instability may be relevant for surgeons undertaking both hip joint preserving surgery and hip arthroplasty.


Asunto(s)
Acetábulo/fisiología , Articulación de la Cadera/fisiología , Cadera/fisiología , Ligamentos Articulares/fisiología , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Cadáver , Cartílago Articular/fisiología , Femenino , Fibrocartílago/fisiología , Humanos , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular , Rotación , Torque
7.
Knee Surg Sports Traumatol Arthrosc ; 23(6): 1763-9, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25552404

RESUMEN

PURPOSE: The popliteus tendon is crucial to postero-lateral stability and prone to iatrogenic injury intra-operatively. Its role in the stability of the replaced knee remains contentious. The aim of this study was to use computer navigation to quantify the effect of popliteus sectioning on the 'envelope of laxity' (EoL) offered by a posterior-stabilised (PS) total knee arthroplasty (TKA) and compare with that of the native knee. METHODS: Loaded cadaveric legs were mounted on a purpose built rig. EoL was measured in 3 degrees of freedom using computer navigation. Knees were subjectively stressed in varus/valgus, internal/external rotation and anterior draw. This was performed preoperatively, during TKA and after sectioning of the popliteus tendon. Real-time data were recorded at 0°, 30°, 60° and 90° of flexion as the operating surgeon stressed the knee in 3 degrees of freedom to its subjective endpoint. Mixed-effect modelling was used to quantify the effects of intervention on degree of laxity. RESULTS: In all conditions, there was an increase in laxity with knee flexion. Insertion of a PS TKA resulted in increased constraint, particularly in rotation. Sectioning of the popliteus did not result in a significant increase in knee laxity to 90º of knee flexion. However, at deeper flexion angles, tendon sectioning overcame the constraints of the implant resulting in a significant increase in rotatory and varus/valgus laxity towards the native condition. CONCLUSION: These findings support the view that certain current designs of PS knee replacement can constrain the knee in flexion in the absence of postero-lateral deficiency. For this implant, isolated sectioning of the popliteus tendon did not substantially generate abnormal knee laxity.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Inestabilidad de la Articulación/cirugía , Articulación de la Rodilla/cirugía , Cirugía Asistida por Computador , Traumatismos de los Tendones/fisiopatología , Anciano , Fenómenos Biomecánicos/fisiología , Cadáver , Femenino , Humanos , Inestabilidad de la Articulación/fisiopatología , Articulación de la Rodilla/fisiopatología , Masculino , Rango del Movimiento Articular/fisiología , Tendones/fisiología , Tendones/cirugía
8.
Physiol Meas ; 35(5): N29-40, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24711048

RESUMEN

Measuring gait asymmetry is an important feature when characterizing functional imbalance between limbs. This could be due to pathologies, such as osteoarthritis, stroke, or associated with the effects of surgeries such as hip arthroplasty. Generally, the study of asymmetry or imbalance has required the use of a gait lab or force plates, which could be expensive and difficult to use in home settings. This work validates the use of a light weight ear sensor (7.4 g) with an instrumented treadmill for 64 subjects (age (60.04 (15.36)) including healthy subjects (14) as well as subjects who had been treated for hip (17), knee-replacement surgery (21) and knee osteoarthritis (12). Subjects performed treadmill walking at several speeds on flat surfaces, inclines and declines. Accelerometer data from the ear sensor were segmented into consecutive steps and temporal features were extracted. The measures of gait cycle time and step-period asymmetry obtained from the ear sensor matched well those of the treadmill for flat surfaces, inclines and declines. The key implication of the study is that the proposed method could replace expensive equipment for monitoring temporal gait features in clinics as well as free-living environments, which is important for monitoring rehabilitation after surgery and the progress of diseases affecting limb imbalance.


Asunto(s)
Oído , Marcha/fisiología , Monitoreo Fisiológico/instrumentación , Adulto , Estudios de Casos y Controles , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis/fisiopatología , Factores de Tiempo
9.
Bone Joint J ; 96-B(3): 325-31, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24589786

RESUMEN

There have been differing descriptions of the anterolateral structures of the knee, and not all have been named or described clearly. The aim of this study was to provide a clear anatomical interpretation of these structures. We dissected 40 fresh-frozen cadaveric knees to view the relevant anatomy and identified a consistent structure in 33 knees (83%); we termed this the anterolateral ligament of the knee. This structure passes antero-distally from an attachment proximal and posterior to the lateral femoral epicondyle to the margin of the lateral tibial plateau, approximately midway between Gerdy's tubercle and the head of the fibula. The ligament is superficial to the lateral (fibular) collateral ligament proximally, from which it is distinct, and separate from the capsule of the knee. In the eight knees in which it was measured, we observed that the ligament was isometric from 0° to 60° of flexion of the knee, then slackened when the knee flexed further to 90° and was lengthened by imposing tibial internal rotation.


Asunto(s)
Articulación de la Rodilla/anatomía & histología , Ligamentos Articulares/anatomía & histología , Anciano , Anciano de 80 o más Años , Cadáver , Disección , Femenino , Humanos , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular , Fracturas de la Tibia/patología
10.
Knee Surg Sports Traumatol Arthrosc ; 22(8): 1736-43, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23832172

RESUMEN

PURPOSE: Functional outcomes after knee arthroplasty (TKA) remain poor. The ability to restore the soft tissue envelope intraoperatively may improve such outcomes. The aim of this study was to extend the scope of computer navigation as a tool to quantifying the envelope of laxity during subjective stress testing preoperatively and to quantify the effects of knee replacement and how it changes as a result of ligamentous failure. METHODS: Loaded cadaveric legs were mounted on a purpose-built rig. Envelope of laxity was measured in 3 degrees of freedom using computer navigation. Knees were subjectively stressed in varus/valgus, internal/external rotation and anterior draw. This was performed preoperatively, during TKA and after sequential sectioning of ligaments. Real-time data were recorded at 0°, 30°, 60° and 90° of flexion. Mixed effect modelling was used to quantify the effects of intervention on degree of laxity. RESULTS: In all cases, there was an increase in laxity with increasing flexion or ligament sectioning. Operator and movement cycle had no effect. Insertion of a TKA showed increased stability within the joint, especially in internal/external rotation and anterior drawer. Once the PCL and popliteus were cut, the implant only maintained some rotatory stability; thereafter, the soft tissue envelope failed. CONCLUSIONS: This work has shown a novel way by which computer navigation can be used to analyse soft tissue behaviour during TKA beyond the coronal plane and throughout range of motion. Despite subjective stress testing, our results show reproducible patterns of soft tissue behaviour-in particular a wide range of mid-flexion excursion. It also quantifies the limits within which a cruciate-retaining TKR can maintain knee stability. This functionality may guide the surgeon in identifying and/or preventing soft tissue imbalances intra-operatively, improving functional results.


Asunto(s)
Inestabilidad de la Articulación/fisiopatología , Articulación de la Rodilla/fisiología , Rodilla/fisiología , Artroplastia de Reemplazo de Rodilla , Cadáver , Cartílago Articular/fisiología , Humanos , Cápsula Articular/fisiología , Inestabilidad de la Articulación/diagnóstico , Ligamentos Articulares/fisiología , Modelos Anatómicos , Rango del Movimiento Articular , Cirugía Asistida por Computador
11.
Knee Surg Sports Traumatol Arthrosc ; 22(3): 534-42, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23728417

RESUMEN

PURPOSE: Poor knee extension function after total knee arthroplasty (TKA) is associated with factors including articular geometry and alignment. Femoral trochlear geometry has evolved from symmetrical to become more prominent proximal-laterally, with the groove aligned proximal-lateral to distal-medial. This study in vitro tested the hypothesis that a modern asymmetrical prosthesis would restore patellar tracking and stability to more natural behaviour than an older symmetrical prosthesis. METHODS: Six knees had their patellar tracking measured optically during active knee extension. Medial-lateral force versus displacement stability was measured at fixed angles of knee flexion. The measurements were repeated after inserting each of the symmetrical and asymmetrical TKAs. RESULTS: Significant differences of patellar lateral displacement stability, compared to normal, were not found at any angle of knee flexion. The patella tracked medial-laterally within 2.5 mm of the natural path with both TKAs. However, for both TKAs near knee extension, the patella was tilted laterally by approximately 6° and was also flexed approximately 8° more than in the natural knee. CONCLUSION: The hypothesis was not supported: The more anatomical component design did not provide more anatomical patellar kinematics and stability.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Articulación de la Rodilla/fisiología , Prótesis de la Rodilla , Rótula/fisiología , Fenómenos Biomecánicos , Fémur , Humanos , Articulación de la Rodilla/cirugía , Rótula/cirugía , Rango del Movimiento Articular , Rotación
12.
J Bone Joint Surg Br ; 93(11): 1440-8, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22058292

RESUMEN

This annotation considers the place of extra-articular reconstruction in the treatment of anterior cruciate ligament (ACL) deficiency. Extra-articular reconstruction has been employed over the last century to address ACL deficiency. However, the technique has not gained favour, primarily due to residual instability and the subsequent development of degenerative changes in the lateral compartment of the knee. Thus intra-articular reconstruction has become the technique of choice. However, intra-articular reconstruction does not restore normal knee kinematics. Some authors have recommended extra-articular reconstruction in conjunction with an intra-articular technique. The anatomy and biomechanics of the anterolateral structures of the knee remain largely undetermined. Further studies to establish the structure and function of the anterolateral structures may lead to more anatomical extra-articular reconstruction techniques that supplement intra-articular reconstruction. This might reduce residual pivot shift after an intra-articular reconstruction and thus improve the post-operative kinematics of the knee.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior/métodos , Ligamento Cruzado Anterior/cirugía , Traumatismos de la Rodilla/cirugía , Lesiones del Ligamento Cruzado Anterior , Reconstrucción del Ligamento Cruzado Anterior/tendencias , Humanos , Inestabilidad de la Articulación/diagnóstico , Inestabilidad de la Articulación/etiología , Inestabilidad de la Articulación/cirugía , Articulación de la Rodilla/fisiopatología , Resultado del Tratamiento
13.
J Bone Joint Surg Br ; 93(2): 237-44, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21282765

RESUMEN

The purpose of this study was to assess the stability of a developmental pelvic reconstruction system which extends the concept of triangular osteosynthesis with fixation anterior to the lumbosacral pivot point. An unstable Tile type-C fracture, associated with a sacral transforaminal fracture, was created in synthetic pelves. The new concept was compared with three other constructs, including bilateral iliosacral screws, a tension band plate and a combined plate with screws. The pubic symphysis was plated in all cases. The pelvic ring was loaded to simulate single-stance posture in a cyclical manner until failure, defined as a displacement of 2 mm or 2°. The screws were the weakest construct, failing with a load of 50 N after 400 cycles, with maximal translation in the craniocaudal axis of 12 mm. A tension band plate resisted greater load but failure occurred at 100 N, with maximal rotational displacement around the mediolateral axis of 2.3°. The combination of a plate and screws led to an improvement in stability at the 100 N load level, but rotational failure still occurred around the mediolateral axis. The pelvic reconstruction system was the most stable construct, with a maximal displacement of 2.1° of rotation around the mediolateral axis at a load of 500 N.


Asunto(s)
Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Huesos Pélvicos/lesiones , Huesos Pélvicos/cirugía , Placas Óseas , Tornillos Óseos , Fijación Interna de Fracturas/instrumentación , Humanos , Ilion/fisiopatología , Ensayo de Materiales/métodos , Modelos Anatómicos , Rotación , Sacro/fisiopatología , Estrés Mecánico
15.
J Med Eng Technol ; 34(3): 159-65, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20143960

RESUMEN

The purpose of this study was to develop a technique to use Roentgen stereophotogrammetric analysis (RSA) to measure migration of soft-tissue structures after rotator cuff repair. RSA stereo films were obtained; images were analysed using a semi-automatic software program allowing 3D viewing of results. RSA imaging experiments were performed to validate the technique, using a glass phantom with implanted RSA beads and an animal model with steel sutures as RSA markers which were moved known distances. Repeated measurements allowed assessment of inter- and intra-observer variability at a maximum of 1.06 mm. RSA analysis of the phantom showed a variation up to 0.22 mm for static and 0.28 mm for dynamic studies. The ovine tissue specimen demonstrated that using steel sutures as RSA markers in soft tissue is feasible, although less accurate than when measuring bone motion. This novel application of RSA to measure soft tissue migration is practicable and can be extended to in vivo studies.


Asunto(s)
Algoritmos , Imagenología Tridimensional/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Fotogrametría/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Lesiones del Manguito de los Rotadores , Manguito de los Rotadores/diagnóstico por imagen , Animales , Imagenología Tridimensional/instrumentación , Movimiento (Física) , Fantasmas de Imagen , Fotogrametría/instrumentación , Sensibilidad y Especificidad , Ovinos
16.
J Biomech ; 42(6): 665-70, 2009 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-19268951

RESUMEN

Few in-vitro studies have investigated changes in kinematics caused by total knee replacement (TKR) implantation. The advent of surgical navigation systems allows implant position to be measured accurately and the effects of alteration of TKR position and alignment investigated. A test rig and protocol were developed to compare the kinematics of TKR-implanted knees for different femoral component positions. The TKR was implanted and the component positions documented using a navigation system. The quadriceps was tensed and the knees were flexed and extended manually. Torques and drawer forces were applied to the tibia during knee flexion-extension, while recording the kinematics with the navigation system. The implant was removed and replaced on an intramedullary fixation that allowed proximal-distal, and internal-external rotation of the femoral component without conducting a repeated arthrotomy on the knee. The implant was repositioned using the navigation system to reproduce the previously achieved normally navigated position and the kinematics were recorded again. The recorded kinematics of the knee were not significantly different between both normal implantation and intramedullary remounting for tibial internal-external rotation, varus-valgus angulation, or posterior drawer, at any angle of knee flexion examined. Anterior drawer was increased approximately 2.5mm across the range 20-35 degrees knee flexion (p<0.05), but was otherwise not significantly different. This method of navigating implant components and of moving them within the closed knee (thus avoiding artefactual effects of repeated soft tissue manipulations) can now be used to quantify the effect on kinematics of alteration of the position of the femoral component.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Rodilla/fisiología , Fenómenos Biomecánicos , Humanos , Rodilla/cirugía , Estrés Mecánico
17.
Br J Sports Med ; 43(8): 574-8, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19042920

RESUMEN

OBJECTIVE: Acetabular labral tears predominantly affect young patients and are a source of hip pain in the athlete. Four causes of the initiation of labral tears have been proposed; trauma, hypolaxity of the anterior capsule, dysplasia and bony impingement. A further cause could be reduced biomechanical properties in the area most susceptible to tears. However, no work has defined these properties. DESIGN: 32 compressive and 32 tensile test samples were harvested from fresh-frozen cadaveric acetabula. The labrum was divided into eight areas to allow comparison around its circumference. Semiconfined compressive testing and tensile testing were performed at a displacement rate of 10 mm/min in a controlled environment of 100% humidity at 37 (SD 1) degrees C. SETTING: Cadaveric study. RESULTS: The mean compressive stiffness was 31.75 (SD 16.7) MPa, and the mean tensile elastic modulus was 24.7 (SD 10.8) MPa. The anterosuperior region had a significantly lower compressive elastic modulus than either of the posterior quadrants (p<0.05) and a significantly lower tensile modulus to the anterioinferior area (p<0.05). CONCLUSIONS: The biomechanical properties in the anterosuperior region may be a contributing factor to the initiation of labral tears.


Asunto(s)
Acetábulo/lesiones , Cartílago Articular/lesiones , Lesiones de la Cadera/etiología , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Cadáver , Módulo de Elasticidad , Humanos , Rotura , Resistencia a la Tracción/fisiología
18.
Knee Surg Sports Traumatol Arthrosc ; 16(12): 1121-32, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18802689

RESUMEN

The menisci of the knee act primarily to redistribute contact force across the tibio-femoral articulation. This meniscal function is achieved through a combination of the material, geometry and attachments of the menisci. The main ligaments that attach the menisci to the tibia (insertional ligaments, deep medial collateral ligament), the femur (meniscofemoral ligaments, deep medial collateral ligament) and each other (the anterior intermeniscal ligament) are the means by which the contact force between tibia and femur is distributed into hoop stresses in the menisci to reduce contact pressure at the joint. This means that the functional biomechanics of the menisci cannot be considered in isolation and should be considered as the functional biomechanics of the meniscus-meniscal ligament construct. This article presents the current knowledge on the anatomy and functional biomechanics of the meniscus and its associated ligaments. Much is known about the function of the meniscus-meniscal ligament construct; however, there still remain significant gaps in the literature in terms of the properties of the anterior intermeniscal ligament and its function, the properties of the insertional ligaments, and the most appropriate ways to reconstruct meniscal function surgically.


Asunto(s)
Fenómenos Biomecánicos/fisiología , Ligamentos Articulares/anatomía & histología , Meniscos Tibiales/anatomía & histología , Meniscos Tibiales/fisiología , Humanos , Ligamentos Articulares/fisiología
19.
J Bone Joint Surg Br ; 90(7): 864-9, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18591593

RESUMEN

Objective patellar instability has been correlated with dysplasia of the femoral trochlea. This in vitro study tested the hypothesis that trochleoplasty would increase patellar stability and normalise the kinematics of a knee with a dysplastic trochlea. Six fresh-frozen knees were loaded via the heads of the quadriceps. The patella was displaced 10 mm laterally and the displacing force was measured from 0 degrees to 90 degrees of flexion. Patellar tracking was measured from 0 degrees to 130 degrees of knee flexion using magnetic sensors. These tests were repeated after raising the central anterior trochlea to simulate dysplasia, and repeated again after performing a trochleoplasty on each specimen. The simulated dysplasia significantly reduced stability from that of the normal knee (p < 0.001). Trochleoplasty significantly increased the stability (p < 0.001), so that it did not then differ significantly from the normal knee (p = 0.244). There were small but statistically significant changes in patellar tracking (p< 0.001). This study has provided objective biomechanical data to support the use of trochleoplasty in the treatment of patellar instability associated with femoral trochlear dysplasia.


Asunto(s)
Inestabilidad de la Articulación/cirugía , Osteotomía/métodos , Rótula/cirugía , Fenómenos Biomecánicos/métodos , Cadáver , Medicina Basada en la Evidencia , Humanos , Inestabilidad de la Articulación/etiología , Rótula/anatomía & histología , Estrés Mecánico
20.
J Bone Joint Surg Br ; 90(4): 527-34, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18378934

RESUMEN

Anatomical descriptions of the lateral retinaculum have been published, but the attachments, name or even existence of its tissue bands and layers are ill-defined. We have examined 35 specimens of the knee. The deep fascia is the most superficial layer and the joint capsule is the deepest. The intermediate layer is the most substantial and consists of derivatives of the iliotibial band and the quadriceps aponeurosis. The longitudinal fibres of the iliotibial band merge with those of the quadriceps aponeurosis adjacent to the patella. These longitudinal fibres are reinforced by superficial arciform fibres and on the deep aspect by transverse fibres of the iliotibial band. The latter are dense and provide attachment of the iliotibial band to the patella and the tendon of vastus lateralis obliquus. Our study identifies two important new findings which are a constant connection of the deep fascia to the quadriceps tendon superior and lateral to the patella, and, a connection of the deeper transverse fibres to the tendon of vastus lateralis obliquus.


Asunto(s)
Articulación de la Rodilla/anatomía & histología , Ligamento Rotuliano/anatomía & histología , Humanos , Inestabilidad de la Articulación/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...