Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 95(10)2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-39365114

RESUMEN

Rheological characteristics exhibit significant variations at nanoscale confinement or near interfaces, compared to bulk rheological properties. To bridge the gap between nano- and bulk-scale rheology, allowing for a better and holistic understanding of rheology, developing a single experimental platform that provides rheological measurements across different scales, from nano to bulk, is desirable. Here, we present the novel methodology for multiscale rheology using a highly sensitive atomic force microscope based on a quartz tuning fork (QTF) force sensor. We employ microscale and nanoscale shear probes attached to the QTF, oscillating parallel to a substrate surface for rheological measurements as a function of the tip-substrate distance with sub-nanometer resolution. Silicone oils with viscosities ranging from 5 cSt to 10 000 cSt are used as calibration samples, and we have successfully derived the bulk rheological moduli. Furthermore, an increase in modulus is observed within the regime of tribo-nanorheology at distances less than 50 nm from the surface. Through such multiscale measurements, it is confirmed that this increase is due to the formation of a layered structure of silicone oil polymers on the solid surface. These results provide a comprehensive understanding of the tribo-rheological properties of complex fluids across different scales.

2.
Anim Cells Syst (Seoul) ; 28(1): 481-494, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39364144

RESUMEN

Quantum dots have diverse biomedical applications, from constructing biological infrastructures like medical imaging to advancing pharmaceutical research. However, concerns about human health arise due to the toxic potential of quantum dots based on heavy metals. Therefore, research on quantum dots has predominantly focused on oxidative stress, cell death, and other broader bodily toxicities. This study investigated the toxicity and cellular responses of mouse embryonic stem cells (mESCs) and mouse adult stem cells (mASCs) to nitrogen-doped carbon quantum dots (NCQDs) made of non-metallic materials. Cells were exposed to NCQDs, and we utilized a fluorescent ubiquitination-based cell system to verify whether NCQDs induce cytotoxicity. Furthermore, we validated the differentiation-inducing impact of NCQDs by utilizing embryonic stem cells equipped with the Oct4 enhancer-GFP reporter system. By analyzing gene expression including Crebzf, Chop, and ATF6, we also observed that NCQDs robustly elicited endoplasmic reticulum (ER) stress. We confirmed that NCQDs induced cytotoxicity and abnormal differentiation. Interestingly, we also confirmed that low concentrations of NCQDs stimulated cell proliferation in both mESCs and mASCs. In conclusion, NCQDs modulate cell death, proliferation, and differentiation in a concentration-dependent manner. Indiscriminate biological applications of NCQDs have the potential to cause cancer development by affecting normal cell division or to fail to induce normal differentiation by affecting embryonic development during pregnancy. Therefore, we propose that future biomedical applications of NCQDs necessitate comprehensive and diverse biological studies.

3.
Nano Converg ; 11(1): 4, 2024 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-38279984

RESUMEN

Halide perovskites have emerged as promising materials for various optoelectronic devices because of their excellent optical and electrical properties. In particular, halide perovskite quantum dots (PQDs) have garnered considerable attention as emissive materials for light-emitting diodes (LEDs) because of their higher color purities and photoluminescence quantum yields compared to conventional inorganic quantum dots (CdSe, ZnSe, ZnS, etc.). However, PQDs exhibit poor structural stabilities in response to external stimuli (moisture, heat, etc.) owing to their inherent ionic nature. This review presents recent research trends and insights into improving the structural stabilities of PQDs. In addition, the origins of the poor structural stabilities of PQDs and various methods to overcome this drawback are discussed. The structural degradation of PQDs is mainly caused by two mechanisms: (1) defect formation on the surface of the PQDs by ligand dissociation (i.e., detachment of weakly bound ligands from the surface of PQDs), and (2) vacancy formation by halide migration in the lattices of the PQDs due to the low migration energy of halide ions. The structural stabilities of PQDs can be improved through four methods: (1) ligand modification, (2) core-shell structure, (3) crosslinking, and (4) metal doping, all of which are presented in detail herein. This review provides a comprehensive understanding of the structural stabilities and opto-electrical properties of PQDs and is expected to contribute to future research on improving the device performance of perovskite quantum dot LEDs (PeLEDs).

4.
Nanoscale Adv ; 5(8): 2271-2279, 2023 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-37056614

RESUMEN

Manipulating the surface chemistry of graphene is critical to many applications that are achievable by chemical functionalization. Specifically, tailoring the spatial distribution of functional groups offers more opportunities to explore functionality using continuous changes in surface energy. To this end, careful consideration is required to demonstrate the chemical gradient on graphene surfaces, and it is necessary to develop a technique to pattern the spatial distribution of functional groups. Here, we demonstrate the tailoring of a chemical gradient through direct mechanochemical cleavage of atoms from chemically functionalized graphene surfaces via an atomic force microscope. Additionally, we define the surface characteristics of the fabricated sample by using lateral force microscopy revealing the materials' intrinsic properties at the nanoscale. Furthermore, we perform the cleaning process of the obtained lateral force images by using a machine learning method of truncated singular value decomposition. This work provides a useful technique for many applications utilizing continuous changes in the surface energy of graphene.

5.
Nat Commun ; 14(1): 1891, 2023 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-37045823

RESUMEN

The generation of high-purity localized trions, dynamic exciton-trion interconversion, and their spatial modulation in two-dimensional (2D) semiconductors are building blocks for the realization of trion-based optoelectronic devices. Here, we present a method for the all-optical control of the exciton-to-trion conversion process and its spatial distributions in a MoS2 monolayer. We induce a nanoscale strain gradient in a 2D crystal transferred on a lateral metal-insulator-metal (MIM) waveguide and exploit propagating surface plasmon polaritons (SPPs) to localize hot electrons. These significantly increase the electrons and efficiently funnel excitons in the lateral MIM waveguide, facilitating complete exciton-to-trion conversion even at ambient conditions. Additionally, we modulate the SPP mode using adaptive wavefront shaping, enabling all-optical control of the exciton-to-trion conversion rate and trion distribution in a reversible manner. Our work provides a platform for harnessing excitonic quasiparticles efficiently in the form of trions at ambient conditions, enabling high-efficiency photoconversion.

6.
Allergy Asthma Immunol Res ; 15(3): 316-335, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37075797

RESUMEN

PURPOSE: Obstructive sleep apnea (OSA), a highly prevalent and potentially serious sleep disorder, requires effective screening tools. Saliva is a useful biological fluid with various metabolites that might also influence upper airway patency by affecting surface tension in the upper airway. However, little is known about the composition and role of salivary metabolites in OSA. Therefore, we investigated the metabolomics signature in saliva from the OSA patients and evaluated the associations between identified metabolites and salivary surface tension. METHODS: We studied 68 subjects who visited sleep clinic due to the symptoms of OSA. All underwent full-night in-lab polysomnography. Patients with apnea-hypopnea index (AHI) < 10 were classified to the control, and those with AHI ≥ 10 were the OSA groups. Saliva samples were collected before and after sleep. The centrifuged saliva samples were analyzed by liquid chromatography with high-resolution mass spectrometry (ultra-performance liquid chromatography-tandem mass spectrometry; UPLC-MS/MS). Differentially expressed salivary metabolites were identified using open source software (XCMS) and Compound Discoverer 2.1. Metabolite set enrichment analysis (MSEA) was performed using MetaboAnalyst 5.0. The surface tension of the saliva samples was determined by the pendant drop method. RESULTS: Three human-derived metabolites (1-palmitoyl-2-[5-hydroxyl-8-oxo-6-octenoyl]-sn-glycerol-3-phosphatidylcholine [PHOOA-PC], 1-palmitoyl-2-[5-keto-8-oxo-6-octenoyl]-sn-glycerol-3-phosphatidylcholine [KPOO-PC], and 9-nitrooleate) were significantly upregulated in the after-sleep salivary samples from the OSA patients compared to the control group samples. Among the candidate metabolites, only PHOOA-PC was correlated with the AHI. In OSA samples, salivary surface tension decreased after sleep. The differences in surface tension were negatively correlated with PHOOA-PC and 9-nitrooleate concentrations. Furthermore, MSEA revealed that arachidonic acid-related metabolism pathways were upregulated in the after-sleep samples from the OSA group. CONCLUSIONS: This study revealed that salivary PHOOA-PC was correlated positively with the AHI and negatively with salivary surface tension in the OSA group. Salivary metabolomic analysis may improve our understanding of upper airway dynamics and provide new insights into novel biomarkers and therapeutic targets in OSA.

7.
Nanoscale Adv ; 5(4): 1070-1078, 2023 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-36798505

RESUMEN

The micropipette, pencil-shaped with an aperture diameter of a few micrometers, is a potentially promising tool for the three-dimensional (3D) printing of individual microstructures based on its capability to deliver low volumes of nanomaterial solution on a desired spot resulting in micro/nanoscale patterning. Here, we demonstrate a direct 3D printing technique in which a micropipette with a cadmium selenide (CdSe) quantum dot (QD) solution is guided by an atomic force microscope with no electric field and no piezo-pumping schemes. We define the printed CdSe QD wires, which are a composite material with a QD-liquid coexistence phase, by using photoluminescence and Raman spectroscopy to analyze their intrinsic properties and additionally demonstrate a means of directional falling.

8.
Materials (Basel) ; 15(15)2022 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-35955153

RESUMEN

"Wear and Corrosion Resistance Technology of Thin Film Materials" is a new and open Special Issue published in Materials, presenting research and review papers that focus on the wear and corrosion resistance of various materials, new scientific issues and their useful applications in wear and corrosion research and industrial sectors [...].

9.
Nanomicro Lett ; 14(1): 13, 2021 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-34862935

RESUMEN

Additive manufacturing-also known as 3D printing-has attracted much attention in recent years as a powerful method for the simple and versatile fabrication of complicated three-dimensional structures. However, the current technology still exhibits a limitation in realizing the selective deposition and sorting of various materials contained in the same reservoir, which can contribute significantly to additive printing or manufacturing by enabling simultaneous sorting and deposition of different substances through a single nozzle. Here, we propose a dielectrophoresis (DEP)-based material-selective deposition and sorting technique using a pipette-based quartz tuning fork (QTF)-atomic force microscope (AFM) platform DEPQA and demonstrate multi-material sorting through a single nozzle in ambient conditions. We used Au and silica nanoparticles for sorting and obtained 95% accuracy for spatial separation, which confirmed the surface-enhanced Raman spectroscopy (SERS). To validate the scheme, we also performed a simulation for the system and found qualitative agreement with the experimental results. The method that combines DEP, pipette-based AFM, and SERS may widely expand the unique capabilities of 3D printing and nano-micro patterning for multi-material patterning, materials sorting, and diverse advanced applications.

10.
Nanomaterials (Basel) ; 11(6)2021 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-34204454

RESUMEN

The accurate measurement of nanoscale mechanical characteristics is crucial in the emerging field of soft condensed matter for industrial applications. An atomic force microscope (AFM) can be used to conduct nanoscale evaluation of the Young's modulus on the target surface based on site-specific force spectroscopy. However, there is still a lack of well-organized study about the nanomechanical interpretation model dependence along with cantilever stiffness and radius of the tip apex for the Young's modulus measurement on the soft materials. Here, we present the fast and accurate measurement of the Young's modulus of a sample's entire scan surface using the AFM in a newly developed PinPointTM nanomechanical mode. This approach enables simultaneous measurements of topographical data and force-distance data at each pixel within the scan area, from which quantitative visualization of the pixel-by-pixel topographical height and Young's modulus of the entire scan surface was realized. We examined several models of contact mechanics and showed that cantilevers with proper mechanical characteristics such as stiffness and tip radius can be used with the PinPointTM mode to accurately evaluate the Young's modulus depending on the sample type.

11.
Phys Chem Chem Phys ; 23(21): 12387-12394, 2021 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-34027528

RESUMEN

Ionic liquids (ILs) are emerging as novel solvents that exhibit peculiar mechanical properties in the form of thin films on metal surfaces under normal pressure. However, the mechanical properties of ILs in the form of nano-meniscus have not been analyzed yet. Here, we investigate the shear viscoelasticity of a single IL meniscus at the nanoscale. To characterize the shear rheological properties of ILs, we employ a quartz tuning fork-based atomic force microscope, conduct dynamic force spectroscopy, and analyse shear properties using the non-Newtonian-Maxwell model. The elastic response of the IL nanomeniscus is found to be about 25 times higher than that of the bulk IL bridge, whereas the viscous responses are similar. In addition, by conducting shear velocity-dependent measurements, we find that the IL meniscus shows nonlinear rheological behaviours. Interestingly, we observe that the relaxation time of the IL increases at a tip-substrate distance of about 60 nm.

12.
Nanoscale ; 13(14): 6991-6996, 2021 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-33885500

RESUMEN

Surface tension is a key parameter for understanding nucleation in the very initial stage of phase transformation. Although surface tension has been predicted to vary with the curvature of the liquid-vapor interface, particularly at the large curvature of, e.g., the subnanometric critical nucleus, experimental study still remains challenging due to inaccessibility to such a small cluster. Here, by directly measuring the critical size of a single capillary-condensed nanomeniscus using atomic force microscopy, we address the curvature dependence of surface tension of alcohols and observe that the surface tension is doubled for ethanol and n-propanol with a radius-of-curvature of ∼-0.46 nm. We also find that the interface of larger negative (positive) curvature exhibits larger (smaller) surface tension, which evidently governs nucleation at the ∼1 nm scale and below, indicating more facilitated nucleation than normally expected. Such well characterized curvature effects contribute to better understanding and accurate analysis of nucleation occurring in various fields including materials science and atmospheric science.

13.
Phys Rev E ; 99(5-1): 052202, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-31212563

RESUMEN

We theoretically investigate the nonlinear behavior of a buckled tip near the bifurcation point under external stress. We present a mechanical model for the buckled tip and derive the governing equation that describes the "buckling-to-flipping" nonlinear transition of the tip motion. Our minimal mechanistic model fully captures the velocity-dependent flipping phenomena, in which the flip position of the tip varies with the speed of the surface motion, as consistently observed in previous experiments. The present study could be applicable for sensitive detection of directional surface motion such as seismic waves.

14.
Sensors (Basel) ; 19(12)2019 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-31207882

RESUMEN

A quartz tuning fork and its qPlus configuration show different characteristics in their dynamic features, including peak amplitude, resonance frequency, and quality factor. Here, we present an electromechanical model that comprehensively describes the dynamic responses of an electrically driven tuning fork and its qPlus configuration. Based on the model, we theoretically derive and experimentally validate how the peak amplitude, resonance frequency, quality factor, and normalized capacitance are changed when transforming a tuning fork to its qPlus configuration. Furthermore, we introduce two experimentally measurable parameters that are intrinsic for a given tuning fork and not changed by the qPlus configuration. The present model and analysis allow quantitative prediction of the dynamic characteristics in tuning fork and qPlus, and thus could be useful to optimize the sensors' performance.

15.
Sensors (Basel) ; 19(8)2019 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-30991660

RESUMEN

We introduce a nanopipette/quartz tuning fork (QTF)-atomic force microscope (AFM) for nanolithography and a nanorod/QTF-AFM for nanoscratching with in situ detection of shear dynamics during performance. Capillary-condensed nanoscale water meniscus-mediated and electric field-assisted small-volume liquid ejection and nanolithography in ambient conditions are performed at a low bias voltage (~10 V) via a nanopipette/QTF-AFM. We produce and analyze Au nanoparticle-aggregated nanowire by using nanomeniscus-based particle stacking via a nanopipette/QTF-AFM. In addition, we perform a nanoscratching technique using in situ detection of the mechanical interactions of shear dynamics via a nanorod/QTF-AFM with force sensor capability and high sensitivity.

16.
Sensors (Basel) ; 18(8)2018 Aug 11.
Artículo en Inglés | MEDLINE | ID: mdl-30103506

RESUMEN

Mechanical sensors provide core keys for high-end research in quantitative understanding of fundamental phenomena and practical applications such as the force or pressure sensor, accelerometer and gyroscope. In particular, in situ sensitive and reliable detection is essential for measurements of the mechanical vibration and displacement forces in inertial sensors or seismometers. However, enhancing sensitivity, reducing response time and equipping sensors with a measurement capability of bidirectional mechanical perturbations remains challenging. Here, we demonstrate the buckling cantilever-based non-linear dynamic mechanical sensor which addresses intrinsic limitations associated with high sensitivity, reliability and durability. The cantilever is attached on to a high-Q tuning fork and initially buckled by being pressed against a solid surface while a flexural stress is applied. Then, buckling instability occurs near the bifurcation region due to lateral movement, which allows high-sensitive detection of the lateral and perpendicular surface acoustic waves with bandwidth-limited temporal response of less than 1 ms.

17.
Sci Rep ; 8(1): 8462, 2018 05 31.
Artículo en Inglés | MEDLINE | ID: mdl-29855619

RESUMEN

When the surface of water is curved at nanoscale as a bubble, droplet and meniscus, its surface tension is expected to be smaller than that of planar interface, which still awaits experimental studies. Here, we report static and dynamic force spectroscopy that measures the capillary force of a single nanoscale water meniscus at constant curvature condition. Based on the Young-Laplace equation, the results are used to obtain the effective surface tension (ST) of the meniscus, which decreases to less than 20% of the bulk value at the radius-of-curvature (ROC) below 25 nm, while indicating the bulk behaviour above ~130 nm ROC. Interestingly, such a possibility provides a qualitative resolution of the unsettled discrepancies between experiments and theories in the thermodynamic activation processes for the mentioned three types of nano-curvatured water. Our results may not only lead to development of microscopic theories of ST as well as further experimental investigations, but also help better understanding of the ST-induced nanoscale dynamics such as cluster growth or protein folding, and the ST-controlled design of nano-biomaterials using the nano-meniscus.

18.
Proc Natl Acad Sci U S A ; 115(12): 2884-2889, 2018 03 20.
Artículo en Inglés | MEDLINE | ID: mdl-29511105

RESUMEN

Buckling, first introduced by Euler in 1744 [Euler L (1744) Opera Omnia I 24:231], a sudden mechanical sideways deflection of a structural member under compressive stress, represents a bifurcation in the solution to the equations of static equilibrium. Although it has been investigated in diverse research areas, such a common nonlinear phenomenon may be useful to devise a unique mechanical sensor that addresses the still-challenging features, such as the enhanced sensitivity and polarization-dependent detection capability. We demonstrate the bifurcation-enhanced sensitive measurement of mechanical vibrations using the nonlinear buckled cantilever tip in ambient conditions. The cantilever, initially buckled with its tip pinned, flips its buckling near the bifurcation point (BP), where the buckled tip becomes softened. The enhanced mechanical sensitivity results from the increasing fluctuations, unlike the typical linear sensors, which facilitate the noise-induced buckling-to-flipping transition of the softened cantilever. This allows the in situ continuous or repeated single-shot detection of the surface acoustic waves of different polarizations without any noticeable wear of the tip. We obtained the sensitivity above 106 V(m/s)-1, a 1,000-fold enhancement over the conventional seismometers. Our results lead to development of mechanical sensors of high sensitivity, reproducibility, and durability, which may be applied to detect, e.g., the directional surface waves on the laboratory as well as the geological scale.

19.
Nano Lett ; 17(9): 5587-5594, 2017 09 13.
Artículo en Inglés | MEDLINE | ID: mdl-28770607

RESUMEN

The atomic force microscope (AFM) offers a rich observation window on the nanoscale, yet many dynamic phenomena are too fast and too weak for direct AFM detection. Integrated cavity-optomechanics is revolutionizing micromechanical sensing; however, it has not yet impacted AFM. Here, we make a groundbreaking advance by fabricating picogram-scale probes integrated with photonic resonators to realize functional AFM detection that achieve high temporal resolution (<10 ns) and picometer vertical displacement uncertainty simultaneously. The ability to capture fast events with high precision is leveraged to measure the thermal conductivity (η), for the first time, concurrently with chemical composition at the nanoscale in photothermal induced resonance experiments. The intrinsic η of metal-organic-framework individual microcrystals, not measurable by macroscale techniques, is obtained with a small measurement uncertainty (8%). The improved sensitivity (50×) increases the measurement throughput 2500-fold and enables chemical composition measurement of molecular monolayer-thin samples. Our paradigm-shifting photonic readout for small probes breaks the common trade-off between AFM measurement precision and ability to capture transient events, thus transforming the ability to observe nanoscale dynamics in materials.

20.
Nanoscale ; 9(23): 7771-7780, 2017 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-28426088

RESUMEN

Improving the power conversion efficiency of photovoltaic (PV) devices is challenging because the generation, separation and collection of electron-hole pairs are strongly dependent on details of the nanoscale chemical composition and defects which are often poorly known. In this work, two novel scanning probe nano-spectroscopy techniques, direct-transmission near-field scanning optical microscopy (dt-NSOM) and photothermal induced resonance (PTIR), are implemented to probe the distribution of defects and the bandgap variation in thin lamellae extracted from polycrystalline CdTe PV devices. dt-NSOM provides high-contrast spatially-resolved maps of light transmitted through the sample at selected wavelengths. PTIR provides absorption maps and spectra over a broad spectral range, from visible to mid-infrared. Results show variation of the bandgap through the CdTe thickness and from grain to grain that is spatially uncorrelated with the distributions of shallow and deep defects.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...