Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros












Intervalo de año de publicación
1.
Acta Cir Bras ; 38: e384223, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37851786

RESUMEN

PURPOSE: To introduce a new low-cost simulation model for training basic surgical skills. METHODS: The training model was made from a mixture of 20 g of acetic silicone with 11 g of maize starch. Validation consisted of serial training sessions, evaluating the mean pre- and post-training time and the mean final score according to the global rating scale. RESULTS: A decrease in the time required to perform the sutures was observed, comparing the average post and pre-training time of each training day, with a significant correlation between the order of training and the time for performing the simulation. CONCLUSIONS: The presented model proved to be capable of simulating the basic suture training skills. It is easy to make, has low cost, and can be easily reproduced in educational institutions.


Asunto(s)
Competencia Clínica , Entrenamiento Simulado , Simulación por Computador , Suturas
2.
Acta Cir Bras ; 38: e383023, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37646762

RESUMEN

PURPOSE: To evaluate the viability of the porcine vas deferens as a realistic microsurgical training model for vasectomy reversal. METHODS: The model uses swine testicles (vas deferent), which are usually discarded in large street markets since they are not part of Brazilian cuisine. The spermatic cord was carefully dissected, and the vas deferens were isolated, measuring 10 cm in length. A paper quadrilateral with 5 cm2 was built to delimit the surgical training field. The objective of the model is to simulate only the microsurgical step when the vas deferens are already isolated. The parameters analyzed were: feasibility for reproducing the technique, patency before and after performing the vasovasostomy, cost of the model, ease of acquisition, ease of handling, execution time, and model reproducibility. RESULTS: The simulator presented low cost. All models made were viable with a texture similar to human, with positive patency obtained in 100% of the procedures. The internal and external diameters of the vas deferens varied between 0.2-0.4 mm and 2-3 mm, respectively, with a mean length of 9 ± 1.2 cm. The total procedure time was 43.28 ± 3.22 minutes. CONCLUSIONS: The realistic model presented proved to be viable for carrying out vasectomy reversal training, due to its low cost, easy acquisition, and easy handling, and providing similar tissue characteristics to humans.


Asunto(s)
Cordón Espermático , Vasovasostomía , Humanos , Masculino , Animales , Porcinos , Reproducibilidad de los Resultados , Testículo/cirugía , Brasil
3.
Arch. endocrinol. metab. (Online) ; 67(3): 372-377, June 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1429753

RESUMEN

ABSTRACT Objective: To describe the distribution profile of thyroidectomies in Brazil from 2010 to 2020 from a macro-regional perspective. Materials and methods: This is a retrospective, detailed and descriptive study built on secondary data obtained from the Hospital Information System of the Unified Health System (SIH/SUS). We organized the data in tables and grouped them according to the federative unit, macro-region, type of procedure, mortality rate, and year of performance. We performed statistical analysis using the χ2 test to assess the association between the variables, observing a P value of < 0.05 and a confidence interval of 95%. Results: From 2010 to 2020, 160 219 thyroidectomy surgeries were performed, of which 77 812 (48.56%) were total, 38 064 (23.76%) partial and 41 191 (25.70%) oncological.The Southeast was responsible for the largest share of procedures, with 70 745 (44.15%), followed by the Northeast with 43 887 (27.39%). In 2020, the procedure was less performed, with 9226 (5.75%) surgeries. The total mortality rate was 0.16% during the study period. Conclusion: We found that thyroidectomies are carried out mainly in the Southeastern, Northeastern, and Southern regions, and showed a downward trend in 2020, which may be related to the COVID-19 pandemic. In addition, total thyroidectomy is the most performed surgery, and the Northern region had the highest mortality rate.

4.
Arch Endocrinol Metab ; 67(3): 372-377, 2023 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-37011372

RESUMEN

Objective: To describe the distribution profile of thyroidectomies in Brazil from 2010 to 2020 from a macro-regional perspective. Materials and methods: This is a retrospective, detailed and descriptive study built on secondary data obtained from the Hospital Information System of the Unified Health System (SIH/SUS). We organized the data in tables and grouped them according to the federative unit, macro-region, type of procedure, mortality rate, and year of performance. We performed statistical analysis using the χ2 test to assess the association between the variables, observing a P value of < 0.05 and a confidence interval of 95%. Results: From 2010 to 2020, 160 219 thyroidectomy surgeries were performed, of which 77 812 (48.56%) were total, 38 064 (23.76%) partial and 41 191 (25.70%) oncological. The Southeast was responsible for the largest share of procedures, with 70 745 (44.15%), followed by the Northeast with 43 887 (27.39%). In 2020, the procedure was less performed, with 9226 (5.75%) surgeries. The total mortality rate was 0.16% during the study period. Conclusion: We found that thyroidectomies are carried out mainly in the Southeastern, Northeastern, and Southern regions, and showed a downward trend in 2020, which may be related to the COVID-19 pandemic. In addition, total thyroidectomy is the most performed surgery, and the Northern region had the highest mortality rate.


Asunto(s)
COVID-19 , Tiroidectomía , Humanos , Tiroidectomía/métodos , Estudios Retrospectivos , Brasil/epidemiología , Pandemias
5.
Microorganisms ; 11(1)2023 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-36677424

RESUMEN

Mycobacterium tuberculosis (Mtb) Central Asian Strain (CAS) Lineage 3 (L3) genotype is predominantly found in East-Africa, Central-Asia, Western-Asia, and South-Asia; however, a new spoligotyping CAS/SIT2545 was found in northern regions of Brazil. We aimed to characterize and describe the genetic diversity and perform a phylogenetic assessment of this novel genotype. We performed 24-MIRU-VNTR loci and Whole-genome sequencing (WGS) of six Brazilian isolates previously spoligotyped. The libraries were prepared using a Nextera-XT kit and sequenced in a NextSeq 550 Illumina instrument. We performed lineage assignment and genomic characterization. From publicly available genomes of Mtb L3 and other lineages, we created a robust dataset to run the MTBSeq pipeline and perform a phylogenetic analysis. MIRU-VNTR and WGS confirmed CAS/SIT2545 belongs to L3. Out of 1691 genomes, 1350 (79.83%) passed in quality control (genomic coverage > 95%). Strain 431 differed in 52 single nucleotide variants (SNV), confirming it does not belong to the same transmission chain. The eight genomes from a global dataset clustered closer to Brazilian strains differed in >52 SNVs. We hypothesized L3 and L1 were introduced in Brazilian Northern in the same historical event; however, there is a need for additional studies exploring the genetic diversity of Mtb Brazilian Northern.

6.
Rev. bras. oftalmol ; 82: e0058, 2023. tab, graf
Artículo en Portugués | LILACS | ID: biblio-1521784

RESUMEN

RESUMO Objetivo Descrever e validar um modelo oftalmológico para treinamento de transplante e microssutura de córnea utilizando globo ocular bovino. Métodos Para a montagem do modelo de treinamento, o globo ocular foi disposto sob o campo cirúrgico, apoiado sobre um recipiente plástico cilíndrico comum de 3,5cm de diâmetro, para a retirada da córnea. Foi realizada uma incisão circular superficial, e, posteriormente, uma tesoura Castroviejo curva de 9 cm foi utilizada para remoção completa da córnea, que foi recolocada em sua posição original, para que, em seguida, fossem confeccionados nove pontos equidistantes, usando fio de nylon 10-0. Por fim, foram avaliados os seguintes critérios: tempo de realização das suturas; evolução do tempo e da qualidade a cada teste; e destreza e aperfeiçoamento da realização das suturas. Resultados O modelo descrito demonstrou-se viável e adequado para o treinamento de microssuturas na córnea, possibilitando aperfeiçoamento e ganho de habilidades cirúrgicas. Conclusão O modelo de treinamento microcirúrgico apresentado possui alta viabilidade para a simulação de cirurgias oftalmológicas e textura semelhante à do olho humano real, o que o torna próximo à realidade.


ABSTRACT Objective To describe and validate an ophthalmic model for corneal transplantation and micro suture training using a bovine eyeball as a model. Methods For the training model, the eyeball was placed under the sanitary field placed on the ends of a common 3.5cm diameter cylindrical plastic container for corneal removal. A superficial circular incision was made, then 9cm curved Castroviejo scissors were used for complete corneal removal. The cornea was replaced in its original position, and 10-0 nylon thread was used to perform the sutures, with 9 equidistant stitches. Finally, the following criteria were evaluated: suturing time, time and quality progression in each attempt, dexterity and suturing improvement. Results The described model proved to be feasible and suitable for corneal micro suture training, allowing improvement and gain of dexterity in the sport. Conclusion The presented microsurgical training model has a high feasibility for the simulation of ophthalmic surgeries, in addition to a texture similar to the real human eye, which makes it close to reality.


Asunto(s)
Animales , Oftalmología/educación , Trasplante de Córnea/educación , Modelos Animales , Entrenamiento Simulado/métodos , Microcirugia/educación , Materiales de Enseñanza , Bovinos , Técnicas de Sutura/educación , Educación Médica , Modelos Anatómicos
7.
Acta cir. bras ; 38: e384223, 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, VETINDEX | ID: biblio-1513542

RESUMEN

ABSTRACT Purpose: To introduce a new low-cost simulation model for training basic surgical skills. Methods: The training model was made from a mixture of 20 g of acetic silicone with 11 g of maize starch. Validation consisted of serial training sessions, evaluating the mean pre- and post-training time and the mean final score according to the global rating scale. Results: A decrease in the time required to perform the sutures was observed, comparing the average post and pre-training time of each training day, with a significant correlation between the order of training and the time for performing the simulation. Conclusions: The presented model proved to be capable of simulating the basic suture training skills. It is easy to make, has low cost, and can be easily reproduced in educational institutions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...