2.
Anal Chem ; 96(2): 794-801, 2024 01 16.
Artículo en Inglés | MEDLINE | ID: mdl-38127459

RESUMEN

Matrix-assisted laser desorption ionization (MALDI) mass spectrometry imaging (MSI) is a powerful analytical tool that enables molecular sample analysis while simultaneously providing the spatial context of hundreds or even thousands of analytes. However, because of the lack of a separation step prior to ionization and the immense diversity of biomolecules, such as lipids, including numerous isobaric species, the coupling of ultrahigh mass resolution (UHR) with MSI presents one way in which this complexity can be resolved at the spectrum level. Until now, UHR MSI platforms have been restricted to Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometers. Here, we demonstrate the capabilities of an Orbitrap-based UHR MSI platform to reach over 1,000,000 mass resolution in a lipid mass range (600-950 Da). Externally coupling the Orbitrap Q Exactive HF with the high-performance data acquisition system FTMS Booster X2 provided access to the unreduced data in the form of full-profile absorption-mode FT mass spectra. In addition, it allowed us to increase the time-domain transient length from 0.5 to 10 s, providing improvement in the mass resolution, signal-to-noise ratio, and mass accuracy. The resulting UHR performance generates high-quality MALDI MSI images and simplifies the identification of lipids. Collectively, these improvements resulted in a 1.5-fold increase in annotations, demonstrating the advantages of this UHR imaging platform for spatial lipidomics using MALDI-MSI.


Asunto(s)
Ciclotrones , Diagnóstico por Imagen , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Análisis de Fourier , Lípidos/análisis
3.
J Am Soc Mass Spectrom ; 34(7): 1359-1371, 2023 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-37319176

RESUMEN

We discuss the design, development, and evaluation of an Orbitrap/time-of-flight (TOF) mass spectrometry (MS)-based instrument with integrated UV photodissociation (UVPD) and time/mass-to-charge ratio (m/z)-resolved imaging for the comprehensive study of the higher-order molecular structure of macromolecular assemblies (MMAs). A bespoke TOF analyzer has been coupled to the higher-energy collisional dissociation cell of an ultrahigh mass range hybrid quadrupole-Orbitrap MS. A 193 nm excimer laser was employed to photofragment MMA ions. A combination of microchannel plates (MCPs)-Timepix (TPX) quad and MCPs-phosphor screen-TPX3CAM assemblies have been used as axial and orthogonal imaging detectors, respectively. The instrument can operate in four different modes, where the UVPD-generated fragment ions from the native MMA ions can be measured with high-mass resolution or imaged in a mass-resolved manner to reveal the relative positions of the UVPD fragments postdissociation. This information is intended to be utilized for retrieving higher-order molecular structural details that include the conformation, subunit stoichiometry, and molecular interactions as well as to understand the dissociation dynamics of the MMAs in the gas phase.

4.
J Am Soc Mass Spectrom ; 34(4): 720-727, 2023 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-36891615

RESUMEN

Mass spectrometry imaging (MSI) is a surface analysis technique that produces chemical images and is commonly used for biological and biomedical research. Multimodal imaging combines multiple imaging modes in order to get a more comprehensive view of a sample. Multimodal MSI images are often acquired using multiple MSI instruments, which leads to issues regarding image registration and increases the chance of sample damage or degradation during sample transfer. These problems can be solved by using a single instrument that can image in multiple modes. In order to improve the efficiency of multimodal imaging and investigate complementary modes of MSI, we have modified a prototype Bruker timsTOF fleX by adding secondary ion mass spectrometry (SIMS) and secondary electron (SE) imaging capabilities while preserving the ability to perform matrix-assisted laser desorption/ionization (MALDI). We show multimodal images collected on this instrument that required only trivial registration and were acquired without sample transfer between imaging trials. Furthermore, we characterize the performance of SIMS, SE, and MALDI imaging and compare the performance of the modified instrument to a commercial timsTOF fleX.


Asunto(s)
Electrones , Espectrometría de Masa de Ion Secundario , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Espectrometría de Masa de Ion Secundario/métodos
5.
Anal Chem ; 95(2): 1470-1479, 2023 01 17.
Artículo en Inglés | MEDLINE | ID: mdl-36574608

RESUMEN

The Timepix (TPX) is a position- and time-sensitive pixelated charge detector that can be coupled with time-of-flight mass spectrometry (TOF MS) in combination with microchannel plates (MCPs) for the spatially and temporally resolved detection of biomolecules. Earlier generation TPX detectors used in previous studies were limited by a moderate time resolution (at best 10 ns) and single-stop detection for each pixel that hampered the detection of ions with high mass-to-charge (m/z) values at high pixel occupancies. In this study, we have coupled an MCP-phosphor screen-TPX3CAM detection assembly that contains a silicon-coated TPX3 chip to a matrix-assisted laser desorption/ionization (MALDI)-axial TOF MS. A time resolution of 1.5625 ns, per-pixel multihit functionality, simultaneous measurement of TOF and time-over-threshold (TOT) values, and kHz readout rates of the TPX3 extended the m/z detection range of the TPX detector family. The detection of singly charged intact Immunoglobulin M ions of m/z value approaching 1 × 106 Da has been demonstrated. We also discuss the utilization of additional information on impact coordinates and TOT provided by the TPX3 compared to conventional MS detectors for the enhancement of the quality of the mass spectrum in terms of signal-to-noise (S/N) ratio. We show how the reduced dead time and event-based readout in TPX3 compared to the TPX improves the sensitivity of high m/z detection in both low and high mass measurements (m/z range: 757-970,000 Da). We further exploit the imaging capabilities of the TPX3 detector for the spatial and temporal separation of neutral fragments generated by metastable decay at different locations along the field-free flight region by simultaneous application of deflection and retarding fields.


Asunto(s)
Diagnóstico por Imagen , Silicio , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Iones , Rayos Láser
6.
Anal Chem ; 94(42): 14652-14658, 2022 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-36223179

RESUMEN

Mass spectrometry imaging (MSI) maps the spatial distributions of chemicals on surfaces. MSI requires improvements in throughput and spatial resolution, and often one is compromised for the other. In microprobe-mode MSI, improvements in spatial resolution increase the imaging time quadratically, thus limiting the use of high spatial resolution MSI for large areas or sample cohorts and time-sensitive measurements. Here, we bypass this quadratic relationship by combining a Timepix3 detector with a continuously sampling secondary ion mass spectrometry mass microscope. By reconstructing the data into large-field mass images, this new method, fast mass microscopy, enables orders of magnitude higher throughput than conventional MSI albeit yet at lower mass resolution. We acquired submicron, gigapixel images of fingerprints and rat tissue at acquisition speeds of 600,000 and 15,500 pixels s-1, respectively. For the first image, a comparable microprobe-mode measurement would take more than 2 months, whereas our approach took 33.3 min.


Asunto(s)
Microscopía , Espectrometría de Masa de Ion Secundario , Ratas , Animales , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos
7.
Anal Chem ; 94(19): 6939-6947, 2022 05 17.
Artículo en Inglés | MEDLINE | ID: mdl-35503862

RESUMEN

Radical resection for patients with oral cavity cancer remains challenging. Rapid evaporative ionization mass spectrometry (REIMS) of electrosurgical vapors has been reported for real-time classification of normal and tumor tissues for numerous surgical applications. However, the infiltrative pattern of invasion of oral squamous cell carcinomas (OSCC) challenges the ability of REIMS to detect low amounts of tumor cells. We evaluate REIMS sensitivity to determine the minimal amount of detected tumors cells during oral cavity cancer surgery. A total of 11 OSCC patients were included in this study. The tissue classification based on 185 REIMS ex vivo metabolic profiles from five patients was compared to histopathology classification using multivariate analysis and leave-one-patient-out cross-validation. Vapors were analyzed in vivo by REIMS during four glossectomies. Complementary desorption electrospray ionization-mass spectrometry imaging (DESI-MSI) was employed to map tissue heterogeneity on six oral cavity sections to support REIMS findings. REIMS sensitivity was assessed with a new cell-based assay consisting of mixtures of cell lines (tumor, myoblasts, keratinocytes). Our results depict REIMS classified tumor and soft tissues with 96.8% accuracy. In vivo REIMS generated intense mass spectrometric signals. REIMS detected 10% of tumor cells mixed with 90% myoblasts with 83% sensitivity and 82% specificity. DESI-MSI underlined distinct metabolic profiles of nerve features and a metabolic shift phosphatidylethanolamine PE(O-16:1/18:2))/cholesterol sulfate common to both mucosal maturation and OSCC differentiation. In conclusion, the assessment of tissue heterogeneity with DESI-MSI and REIMS sensitivity with cell mixtures characterized sensitive metabolic profiles toward in vivo tissue recognition during oral cavity cancer surgeries.


Asunto(s)
Metabolómica , Neoplasias de la Boca , Humanos , Espectrometría de Masas/métodos , Neoplasias de la Boca/cirugía , Análisis Multivariante , Espectrometría de Masa por Ionización de Electrospray/métodos
8.
J Mass Spectrom ; 57(4): e4820, 2022 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-35347816

RESUMEN

Time-of-flight (TOF) systems are one of the most widely used mass analyzers in native mass spectrometry (nMS) for the analysis of non-covalent multiply charged bio-macromolecular assemblies (MMAs). Typically, microchannel plates (MCPs) are employed for high mass native ion detection in TOF MS. MCPs are well known for their reduced detection efficiency when impinged by large slow moving ions. Here, a position- and time-sensitive Timepix (TPX) detector has been added to the back of a dual MCP stack to study the key factors that affect MCP performance for MMA ions generated by nMS. The footprint size of the secondary electron cloud generated by the MCP on the TPX for each individual ion event is analyzed as a measure of MCP performance at each mass-to-charge (m/z) value and resulted in a Poisson distribution. This allowed us to investigate the dependency of ion mass, ion charge, ion velocity, acceleration voltage, and MCP bias voltage on MCP response in the high mass low velocity regime. The study of measurement ranges; ion mass = 195 to 802,000 Da, ion velocity = 8.4 to 67.4 km/s, and ion charge = 1+ to 72+, extended the previously examined mass range and characterized MCP performance for multiply charged species. We derived a MCP performance equation based on two independent ion properties, ion mass and charge, from these results, which enables rapid MCP tuning for single MMA ion detection.

9.
Anal Chem ; 90(20): 12307-12313, 2018 10 16.
Artículo en Inglés | MEDLINE | ID: mdl-30205008

RESUMEN

Chemical identification often relies on matching measured chemical properties and/or spectral "fingerprints" of unknowns against their precompiled libraries. Chromatography, absorption spectroscopy, and mass spectrometry are all among analytical approaches that provide chemical measurement databases amenable to library searching. Occasionally, using conventional single-library or single-domain searches can lead to misidentification of unknowns. To improve chemical identification, we present a tandem gas chromatography/vacuum ultraviolet-mass spectrometry (GC/VUV-MS) chemical identification approach that utilizes databases from GC, VUV spectroscopy, and mass spectrometry analyses for a "multidomain" library search. Using standard chemical mixtures as well as aroma compounds as test cases, we demonstrate that multidatabase library searches utilizing GC, VUV, and MS data results in fully correct identification of chemical mixtures examined here that could only be identified with a 69.2% or an 88.5% success rate with MS or VUV library searches alone, respectively. Additionally, we introduce a library- and data domain-independent metric for evaluating the confidence of library search results. Using multidomain library searches improves both the chemical assignment accuracy and confidence.

10.
Anal Chem ; 90(7): 4878-4885, 2018 04 03.
Artículo en Inglés | MEDLINE | ID: mdl-29505232

RESUMEN

For wide class characterizations of volatile organic compounds (VOCs), conventional gas chromatography mass spectrometry (GC-MS)-based techniques are utilized. These GC-MS-based chemical identification approaches typically rely on library searches against ion fragmentation patterns of known compounds. Although MS library searches can often provide correct chemical identities, erroneous chemical assignments of structurally similar unknown compounds are also possible. Other detection systems, such as absorption spectrometers, have been used for VOC analysis and can provide complementary absorption data. Here, we demonstrate the analytical advantages of coupling vacuum ultraviolet (VUV) absorption spectroscopy and MS in tandem for the improved characterization of structurally similar VOCs. We also discuss technical considerations and limitations of coupling a VUV spectrometer to a quadrupole mass spectrometer. Moreover, we show that combining the isomer selectivity of VUV spectroscopy, as a nondestructive analyte detection approach, with the mass selectivity of MS in a VUV-MS detection system improves characterization of GC-eluting compounds. Utilizing GC/VUV-MS data, we demonstrate that orthogonal VUV and MS library searches improve identification of VOCs present in complex mixtures such as a mixed standard sample, a commercial perfume product, and an essential oil sample.

SELECCIÓN DE REFERENCIAS