Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Ann Transplant ; 23: 554-560, 2018 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-30087315

RESUMEN

BACKGROUND Recent advances in ultrasound strain imaging facilitate more precise monitoring of subtle myocardial changes and thus may allow for more appropriate assessment of myocardium after orthotopic heart transplantation (OHT). This study aimed to explore longitudinal left ventricular (LV) and right ventricular (RV) function by speckle-tracking echocardiography (STE) during a 12-month follow-up period in relation to acute cellular rejection (ACR) degree ≥2R and the response to intense immunosuppressive therapy with intravenous steroids. MATERIAL AND METHODS Forty-five adult heart transplant recipients were prospectively assessed at a single center from January 2016 until June 2017. Echocardiography was performed serially at baseline and together with routine biopsies at 2 weeks and 1, 2, 3, 6, 9, and 12 months after OHT. Changes in graft function were evaluated using STE before and during ACR and in the resolving period of ACR. RESULTS A total of 220 pairs of biopsy specimens and strain recordings were analyzed. Moderate ACR was seen in 30 biopsies (13.6%). In the serial assessment, longitudinal strain parameters of the LV (global and 4-, 2-, 3-chamber longitudinal strain) and RV (global and free wall longitudinal strain) were decreased at baseline and improved significantly (P<0.001) within 12 months after OHT. The degree of improvement was not influenced by ACR. There were no significant differences in circumferential, radial, or longitudinal strain rate, or mechanical dyssynchrony. Reduced LV and RV longitudinal strain was related to ACR degree 2R and increased significantly (P<0.0005) during 3 days of intravenous methylprednisolone therapy. CONCLUSIONS Using the STE technique, we have documented an acute improvement in mechanical myocardial function following ACR steroid therapy and a progressive recovery of LV and RV longitudinal function during the first year after OHT.


Asunto(s)
Ecocardiografía/métodos , Rechazo de Injerto/diagnóstico por imagen , Trasplante de Corazón , Corazón/diagnóstico por imagen , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Estudios Prospectivos
3.
Kardiochir Torakochirurgia Pol ; 14(1): 76-78, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28515757

RESUMEN

Left ventricular assist device (LVAD) thrombosis remains a dreadful complication of mechanical circulatory support, with an incidence of 8-12% depending on the pump type and patient's comorbidities. Fibrinolysis may be considered early in pump thrombosis, but when contraindicated a pump exchange remains the only alternative. This short report documents an emergency LVAD exchange in a 55-year-old man who underwent LVAD (HeartWare Inc) implantation in 2013 as a bridge to transplantation. Four months after the initial surgery, he suffered from a hemorrhagic stroke despite properly managed anticoagulation. On February 17th, 2017 he was re-admitted with LVAD pump thrombosis. As fibrinolysis was contraindicated, an emergency pump exchange was performed via a limited thoracic incision in order to minimize surgical trauma, reduce intraoperative complications and facilitate immediate post-operative recovery. This report documents the very first LVAD pump exchange as well as the first one performed via a minimally invasive approach in Poland.

5.
Interact Cardiovasc Thorac Surg ; 17(2): 428-30, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23599186

RESUMEN

In this case report, we present a patient 28 years after mitral valve replacement with the Starr-Edwards prosthesis complicated by periprosthetic leak with severe aortic stenosis and moderate tricuspid regurgitation. We successfully repaired the periprosthetic regurgitation in a patient with extensive mitral annular calcification, without replacement of the valve. No apparent structural deterioration on the caged-ball valve was found. Moreover, aortic valve replacement and tricuspid annuloplasty were performed. One month after reoperation, the patient remained stable with improved clinical status and without any evidence for further paravalvular leak.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Anciano , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Anuloplastia de la Válvula Cardíaca , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/etiología , Diseño de Prótesis , Reoperación , Factores de Tiempo , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...