Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
2.
Innovations (Phila) ; 12(1): 46-49, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28129320

RESUMEN

OBJECTIVE: In patients with atrial fibrillation, 90% of embolic strokes originate from the left atrial appendage (LAA). Successful exclusion of the LAA is associated with a lower stroke rate in patients with atrial fibrillation. Surgical oversewing of the LAA is often incomplete when evaluated with transesophageal echocardiogram (TEE). External closure techniques of suturing and stapling have also demonstrated high failure rates with persistent flow and large stumps. We hypothesized that the precise visualization of a robotic LAA closure (RLAAC) would result in superior closure rates. METHODS: Before robotic mitral repair, patients underwent RLAAC; the base of the LAA was oversewn using a running 4-0 polytetrafluoroethylene suture in two layers. Postoperatively, the LAA was interrogated in multiple TEE views. Incomplete closure was defined as any flow across the LAA suture line or a residual stump of greater than 1 cm. RESULTS: Seventy-nine consecutive patients underwent RLAAC; no injuries occurred. On postrepair TEE, 73 of 79 patients had LAAs visualized well enough to thoroughly evaluate. Successful ligation was confirmed in 64 (87.7%) of 73 patients. Seven patients (9.6%) had small jet flow into the LAA; no residual stumps were noted. Two patients (2.7%) had undetermined flow. CONCLUSIONS: We have demonstrated excellent success with RLAAC; we postulate that this may be due to improved intracardiac visualization. Robotic LAA closure was more successful (87.7%) than previously reported results from the Left Atrial Appendage Occlusion Study for suture exclusion (45.5%) and staple closure (72.7%). With success rates equivalent to transcatheter device closures, RLAAC should be considered for robotic mitral valve surgical patients.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Procedimientos Quirúrgicos Cardíacos/instrumentación , Procedimientos Quirúrgicos Robotizados/métodos , Anciano , Procedimientos Quirúrgicos Cardíacos/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Técnicas de Cierre de Heridas/instrumentación
3.
J Thorac Cardiovasc Surg ; 148(6): 2787-93, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25212050

RESUMEN

OBJECTIVE: Systolic anterior motion (SAM) can occur after mitral valve repair (MVr), most frequently in patients with degenerative valve disease. Our initial observations (1981-1990) revealed that most patients with SAM can be successfully treated medically. Here the authors review the last 16 years of their experience with SAM after MVr. METHODS: Between January 1996 and October 2011, 1918 patients with degenerative mitral valve disease underwent MVr at our institution. We performed a retrospective analysis of SAM in this patient population. RESULTS: The incidence of SAM was 4.6% (89 of 1918) overall, 4.0% (77 of 1906) in patients who did not have SAM preoperatively (de novo). Compared with our previously published report, the incidence of SAM decreased from 6.4% to 4.0% (P = .03). Hospital mortality was 2.0% (38 of 1918) overall, 1.3% (14 of 1078) for isolated MVr. One patient with de novo SAM (1 of 77; 1.3%) died after emergency MVr. All patients with de novo SAM were successfully managed conservatively with intravenous fluids, α agonists, and/or ß blockers. A higher incidence of SAM was associated with a left ventricular ejection fraction greater than 60% (P = .01), posterior leaflet resection (P = .048), and hypertrophic obstructive cardiomyopathy (P < .01). The incidence of SAM was lower in patients who underwent device mitral annuloplasty with a semirigid posterior band compared with a complete ring (P = .03). CONCLUSIONS: In the more recent era, SAM occurs one-third less frequently after repair of degenerative mitral valve disease. Use of an incomplete annuloplasty band rather than a complete ring is associated with a lower incidence of SAM. The mainstay treatment of SAM continues to be medical management.


Asunto(s)
Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Anuloplastia de la Válvula Mitral/efectos adversos , Válvula Mitral/cirugía , Complicaciones Posoperatorias/fisiopatología , Sístole , Anciano , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/mortalidad , Enfermedades de las Válvulas Cardíacas/fisiopatología , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Mortalidad Hospitalaria , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Válvula Mitral/fisiopatología , Anuloplastia de la Válvula Mitral/instrumentación , Anuloplastia de la Válvula Mitral/mortalidad , Ciudad de Nueva York , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Diseño de Prótesis , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
4.
Echocardiography ; 30(8): E243-8, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23808930

RESUMEN

Anomalies of the membranous portion of the interventricular septum include perimembranous ventricular septal defect and/or membranous septal aneurysm (MSA). In congenitally corrected transposition of the great arteries (L-TGA in sinus solitus), the combination of ventricular inversion and arterial transposition creates a unique anatomic substrate that fosters subpulmonic left ventricular outflow tract obstruction by an MSA. The combination of an L-TGA with subpulmonic obstruction by an MSA is referred to as the windsock syndrome. We report a case of windsock syndrome in a 25-year-old man which is to our knowledge the first three-dimensional echocardiographic description of this congenital entity.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Defectos del Tabique Interventricular/diagnóstico por imagen , Transposición de los Grandes Vasos/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Adulto , Transposición Congénitamente Corregida de las Grandes Arterias , Diagnóstico Diferencial , Humanos , Masculino , Síndrome
5.
Circulation ; 114(1 Suppl): I573-6, 2006 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-16820640

RESUMEN

BACKGROUND: Mild and moderate functional ischemic mitral insufficiency present at the time of surgical revascularization present clinical uncertainty. It is unclear whether the relatively poor outcomes in this cohort are dependent on valvular function or related to left ventricular dysfunction. The purpose of this study was to examine the early and late outcomes in patients with less-than-severe functional ischemic mitral insufficiency at the time of isolated coronary artery bypass grafting (CABG). METHODS AND RESULTS: From 1996 through 2004, 2242 consecutive patients undergoing isolated CABG were identified as having none to moderate mitral regurgitation (MR) and no valve leaflet pathology. All of the patients at this single institution routinely had an intraoperative transesophageal echocardiography, prospectively quantified MR, and ejection fraction (EF). The New York State Cardiac Surgery Reporting System infrastructure was used to prospectively collect in-hospital patient variables and outcomes. Social Security Death Benefit Index was used to determine long-term survival. Odds ratio and significance (P value) are presented for each determined risk factor. There were 841 patients (37.5%) with no MR, 1137 (50.7%) with mild MR, and 264 (11.8%) with moderate MR. The patients with moderate MR were more likely to be older, female, and have more renal disease, previous MI, congestive heart failure, previous cardiac surgery, and lower EFs. Hospital mortality was independently and significantly associated with renal disease, decreasing EF, increasing age, previous cardiac operation, and cerebral vascular disease. Multivariable analysis revealed decreased survival with increasing age, previous operation, congestive heart failure, diabetes, nonelective operation, decreasing EF, and the presence of moderate MR (expbeta = 1.49; P=0.007) and mild MR (expbeta = 1.34; P=0.033). CONCLUSIONS: Independent of ventricular function, mild and moderate functional mitral insufficiency are associated with significantly decreased survival in patients undergoing CABG. Whether correction of moderate functional MR at the time of CABG improves outcome still needs to be determined.


Asunto(s)
Puente de Arteria Coronaria , Enfermedad Coronaria/complicaciones , Insuficiencia de la Válvula Mitral/etiología , Anciano , Estudios de Cohortes , Comorbilidad , Enfermedad Coronaria/cirugía , Femenino , Insuficiencia Cardíaca/epidemiología , Mortalidad Hospitalaria , Humanos , Enfermedades Renales/epidemiología , Tablas de Vida , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/fisiopatología , Infarto del Miocardio/epidemiología , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Volumen Sistólico , Análisis de Supervivencia , Resultado del Tratamiento , Disfunción Ventricular Izquierda/etiología
6.
J Am Soc Echocardiogr ; 17(10): 1050-2, 2004 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-15452470

RESUMEN

BACKGROUND: Transesophageal echocardiography (TEE) has become an integral part of the evaluation and monitoring of patients during cardiac operation. Until recently, the smallest TEE probe with multiplane imaging measured 13 mm in diameter. This size is now standard for adult TEE probes. Recently, a new TEE probe has become available (MiniMulti TEE probe, Philips Medical Systems, Andover, Mass), which has a diameter of 8 mm. Although using a smaller probe is attractive, the quality of images it generates when used in adults has not yet been examined. OBJECTIVE: The purpose of this study was to compare TEE studies done with both probes. METHODS: After informed consent was obtained, full intraoperative TEE studies were performed in 20 patients with a small pediatric probe. The study was then repeated using a standard adult probe. The studies were read in random order by two experienced echocardiographers blinded to probe used. For each study, 18 anatomic cardiac structures and 5 Doppler patterns were subjectively graded as excellent (1), good (2), fair (3), or poor (4) in quality. The average score for each structure or Doppler profile was computed for each probe. RESULTS: The average score for all findings was lower (better) for the adult TEE probe (1.4 +/- 0.4 vs 1.7 +/- 0.4; P =.003). When each finding was compared separately, several cardiac structures (left ventricle [LV], pericardium, right ventricle [RV], interatrial septum, left atrium, left atrial appendage, mitral valve, aortic valve) had better scores with the adult probe, and the differences for the LV and RV were larger than those for the other findings (LV scores differed by 0.7, P =.0004; RV scores differed by 0.5, P =.01). There was no significant difference between probes when evaluating venous structures (coronary sinus, superior vena cava, pulmonary vein), the thoracic aorta, or the right atrium or tricuspid valve. In addition, Doppler patterns were not significantly different with the two probes. There were two findings that were missed with the small probe and seen with the adult probe (one aortic plaque and one left atrial appendage thrombus). CONCLUSIONS: In the adult, the larger probe provides better images, particularly of the RV and LV. In addition, important findings may be missed with the smaller probe. However, if the adult probe cannot be passed, the pediatric probe is a reasonable alternative.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Ecocardiografía Transesofágica/instrumentación , Monitoreo Fisiológico/instrumentación , Anciano , Diseño de Equipo , Femenino , Humanos , Cuidados Intraoperatorios/instrumentación , Masculino , Persona de Mediana Edad
7.
Semin Thorac Cardiovasc Surg ; 16(2): 188-93, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15197696

RESUMEN

Triangular resection is a reconstructive option for treatment of anterior leaflet mitral disease with segmental prolapse. In our experience, it is a safe and reproducible technique, associated with low rates of recurrent MR or need for reoperation, as well as decreased likelihood for systolic anterior motion after mitral repair. We review our experience with this technique over a 25-year experience with mitral valve reconstruction.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Válvula Mitral/patología , Válvula Mitral/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Enfermedades de las Válvulas Cardíacas/mortalidad , Enfermedades de las Válvulas Cardíacas/cirugía , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Isquemia Miocárdica/mortalidad , Isquemia Miocárdica/cirugía , New York , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Cardiopatía Reumática/mortalidad , Cardiopatía Reumática/cirugía , Estadística como Asunto , Factores de Tiempo , Resultado del Tratamiento
8.
Ann Thorac Surg ; 77(2): 518-22; discussion 522, 2004 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-14759429

RESUMEN

BACKGROUND: Traditional mitral annuloplasty devices include both rigid rings, which restrict annular motion, and soft rings and bands, which can locally deform. Conflicting data exist regarding their impact on annular dynamics. We studied mitral annuloplasty with a semirigid partial band and with a nearly complete rigid ring. METHODS: Intraoperative three-dimensional transesophageal echocardiograms (n = 14) and predischarge transthoracic echocardiograms were retrospectively analyzed in patients undergoing mitral valve repair for degenerative disease with either a rigid ring (n = 77) or a semirigid partial band (n = 38). Each transesophageal echocardiogram was analyzed with TomTec three-dimensional software to produce cardiac cycle frame planimetry and to measure device geometry. Actual device sizes provided reference dimensions. Blinded analysis of Doppler data from transthoracic echocardiograms was performed. RESULTS: Validation of the quantitative transesophageal echocardiogram methodology revealed a 1.3% +/- 0.3% (mean +/- standard error of the mean) underestimation of actual linear dimension. With the semirigid partial band, systolic valve orifice area and intertrigonal distance decreased from 6.14 +/- 0.37 to 5.55 +/- 0.24 cm(2) (-9.6%; p = 0.01) and from 2.69 +/- 0.08 to 2.55 +/- 0.13 cm (-5.2%; p = 0.03), respectively. Systolic anterior-posterior distance decreased from 2.1 +/- 0.10 to 1.95 +/- 0.06 cm (-7.1%; p = 0.01) compared with diastole. In contrast, rigid ring orifice area was unchanged (4.12 +/- 0.15 to 4.10 +/- 0.16 cm(2); -0.5%; p = 0.48) during the cardiac cycle. Transthoracic echocardiography revealed significantly lower mitral inflow gradients with semirigid partial band (mean gradients compared with rigid ring, 4.0 +/- 0.3 versus 5.0 +/- 0.3 mm Hg; p = 0.02; peak gradients, 8.9 +/- 0.5 versus 11.1 +/- 0.5 mm Hg; p = 0.01). CONCLUSIONS: Three-dimensional transesophageal echocardiographic measurements of annular dynamics are valid and reliable when discrete annuloplasty devices are present. In contrast to the rigid ring, the semirigid partial band permits more physiologic geometric changes and is associated with lower postoperative mitral valve gradients.


Asunto(s)
Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Contracción Miocárdica/fisiología , Ecocardiografía Doppler , Elasticidad , Estudios de Seguimiento , Hemodinámica/fisiología , Humanos , Interpretación de Imagen Asistida por Computador , Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Diseño de Prótesis , Programas Informáticos
9.
J Am Soc Echocardiogr ; 16(11): 1204-10, 2003 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-14608297

RESUMEN

BACKGROUND: Patients after cardiac operation pose a challenge to the treating physician-these patients may become critically ill and are among the most difficult to image using transthoracic echocardiography. Several factors contribute to this, including difficulties in positioning the patient, inability of the patient to cooperate with instructions, surgical dressings, and hyperinflated lungs. Transesophageal echocardiography may be performed when transthoracic echocardiography is not diagnostic; however, transesophageal echocardiography is semi-invasive and does not lend itself to prolonged or repeated monitoring. METHODS: Recently, a new approach to echocardiography for use in the patient after operation has been introduced with the modification of the standard mediastinal drainage tube to allow for substernal epicardial echocardiography (SEE). The SEE tube has 2 lumens. The first allows for routine mediastinal drainage and the second has a blind end that permits the insertion of a standard transesophageal echocardiographic probe for high-resolution imaging as often as is desired over the period during which the mediastinal tube is in place. CONCLUSION: This article reviews the technique of SEE including a description of the method of performance of SEE (with representative images), a review of the published literature on this new modality, examples of clinical use, and a discussion of the advantages, indications, and limitations of SEE with an eye toward future directions for research.


Asunto(s)
Ecocardiografía Transesofágica/métodos , Ecocardiografía/métodos , Pericardio/diagnóstico por imagen , Esternón/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Ecocardiografía/instrumentación , Ecocardiografía Transesofágica/instrumentación , Diseño de Equipo/instrumentación , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Cuidados Intraoperatorios/instrumentación , Cuidados Intraoperatorios/métodos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Cuidados Posoperatorios/instrumentación , Cuidados Posoperatorios/métodos
10.
J Am Soc Echocardiogr ; 16(7): 751-5, 2003 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-12835662

RESUMEN

BACKGROUND: Patients with severe atheromatous aortic disease (AAD) undergoing coronary artery bypass grafting (CABG) have increased operative risks. The "off-pump" CABG (OPCAB) technique was evaluated in patients given the diagnosis of severe AAD by routine transesophageal echocardiography. METHODS: A total of 5737 patients underwent CABG, with 913 having transesophageal echocardiography findings of severe AAD. Of the patients with severe AAD, 678 (74.3%) had conventional CABG and 235 (25.7%) had OPCAB. RESULTS: Hospital mortality was 8.7% for conventional CABG and 5.1% for OPCAB (P =.08). Multivariate analysis revealed that increased mortality was significantly associated with acute myocardial infarction, conventional CABG, age, renal disease, history of stroke, and ejection fraction < 30%. Neurologic complications occurred in 6.3% of patients undergoing CABG and in 2.1% undergoing OPCAB (P =.01). Freedom from any complication was significantly greater with OPCAB. CONCLUSION: Routine intraoperative transesophageal echocardiography identifies patients with severe AAD. In these patients, OPCAB technique is associated with a lower risk of death, stroke, and all complications.


Asunto(s)
Enfermedades de la Aorta/diagnóstico por imagen , Arteriosclerosis/diagnóstico por imagen , Puente de Arteria Coronaria , Ecocardiografía Transesofágica , Enfermedades del Sistema Nervioso/epidemiología , Complicaciones Posoperatorias/epidemiología , Accidente Cerebrovascular/epidemiología , Anciano , Estudios de Casos y Controles , Puente de Arteria Coronaria/métodos , Puente de Arteria Coronaria/mortalidad , Femenino , Mortalidad Hospitalaria , Humanos , Cuidados Intraoperatorios , Masculino , Análisis Multivariante , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo
11.
Ann Thorac Surg ; 75(6): 1808-14, 2003 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-12822620

RESUMEN

BACKGROUND: Patients with reduced ventricular function undergoing aortic valve replacement have increased operative risks, but the impact of valvular pathophysiology and other risk factors has not been clearly defined. METHODS: From June 1992 through June 2002, 1,402 consecutive patients underwent isolated aortic valve surgery with or without coronary artery bypass grafting; of these patients, 416 had an ejection fraction less than 40% and are the subject of this report. These patients (mean age, 68.6) had severe stenosis (62.5%), severe regurgitation (30.3%), or mixed disease (7.2%). Aortic valve replacement plus coronary artery bypass grafting was performed in 48.4% of patients, and 27% had previous cardiac surgery. Follow-up included echocardiography and survival analysis. RESULTS: Hospital mortality was 10.1% (42 of 416), with no difference between aortic stenosis (9.6%) and regurgitation (11.1%). Multivariate analysis revealed that age (p = 0.002) and renal disease (odds ratio = 4.2; 95% confidence interval, 1.9 to 9.3; p = 0.001) were independently associated predictors of mortality. Valvular pathophysiology had no impact on mortality. Peripheral vascular disease, multivessel coronary disease, and renal disease were associated risks for any postoperative complication. Peripheral vascular disease (odds ratio = 12.3, p = 0.02), history of cerebrovascular disease (odds ratio = 4.8, p = 0.038), and diabetes (odds ratio = 2.7, p = 0.04) were associated risks for stroke. The ejection fraction was more than 40% in 52% of the patients who had postoperative echocardiography (mean follow-up, 6 months). Actuarial survival revealed no difference between pathophysiologic groups. CONCLUSIONS: Aortic valve surgery in patients with impaired ventricular function carries an acceptable operative risk that can be stratified by age and comorbidities. The type of valvular pathophysiology does not significantly affect mortality.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Puente de Arteria Coronaria , Estenosis Coronaria/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Disfunción Ventricular Izquierda/cirugía , Anciano , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Terapia Combinada , Comorbilidad , Estenosis Coronaria/mortalidad , Estenosis Coronaria/fisiopatología , Ecocardiografía , Femenino , Estudios de Seguimiento , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/fisiopatología , Factores de Riesgo , Volumen Sistólico/fisiología , Análisis de Supervivencia , Disfunción Ventricular Izquierda/mortalidad , Disfunción Ventricular Izquierda/fisiopatología
12.
Am J Cardiol ; 90(12): 1320-5, 2002 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-12480041

RESUMEN

Severe aortic plaques seen on transesophageal echocardiography (TEE) are a high-risk cause of stroke and peripheral embolization. Evidence to guide therapy is lacking. Retrospective information was obtained regarding the occurrence of embolic events (stroke, transient ischemic attacks, or peripheral emboli) in 519 patients with severe thoracic aortic plaque seen on TEE since 1988. Treatment with statins, warfarin, or antiplatelet medications was noted. Treatment was not randomized. In a matched-paired analysis, each patient taking each class of therapy was matched for age, gender, previous embolic event, hypertension, diabetes, congestive failure, and atrial fibrillation to someone not taking that medication. Multivariate analysis was also performed. An embolic event occurred in 111 patients (21%). Multivariate analysis showed that statin use was independently protective against recurrent events (p = 0.0001). Matched analysis also showed a protective effect of statins (p = 0.0004; absolute risk reduction 17%, relative risk reduction 59%, number needed to treat [n = 6]). No protective effect was found for warfarin or antiplatelet drugs. The odds ratio for embolic events was 0.3 (95% confidence interval [CI] 0.2 to 0.6) for statin therapy, 0.7 (95% CI 0.4 to 1.2) for warfarin, and 1.4 (95% CI 0.8 to 2.4) for antiplatelet agents. Thus, there is a protective effect of statin therapy, and no significant benefit of warfarin or antiplatelet drugs on the incidence of stroke and other embolic events in patients with severe thoracic aortic plaque on TEE.


Asunto(s)
Anticoagulantes/uso terapéutico , Enfermedades de la Aorta/tratamiento farmacológico , Arteriosclerosis/tratamiento farmacológico , Embolia/epidemiología , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Inhibidores de Agregación Plaquetaria/uso terapéutico , Accidente Cerebrovascular/epidemiología , Anciano , Aorta Torácica/diagnóstico por imagen , Enfermedades de la Aorta/diagnóstico por imagen , Arteriosclerosis/diagnóstico por imagen , Ecocardiografía Transesofágica , Embolia/prevención & control , Femenino , Humanos , Incidencia , Estudios Longitudinales , Masculino , Análisis Multivariante , Oportunidad Relativa , Estudios Retrospectivos , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento , Warfarina/uso terapéutico
13.
Arch Intern Med ; 162(20): 2345-7, 2002 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-12418948

RESUMEN

BACKGROUND: Aortic valve thickening (AVT) without aortic stenosis (AS) is common and was often considered benign. However, it has recently been found to be associated with increased morbidity and mortality. It is unknown whether patients with AVT are at risk for the development of AS. METHODS: Our echocardiography database from 1987 to 1993 was searched for cases of AVT with at least 1 year of echocardiographic follow-up. The risk of the development of AS was compared in patients with and without AVT. RESULTS: There were 2131 patients with AVT and at least 1 year of echocardiographic follow-up. Aortic stenosis developed in 338 patients (15.9%) (mild, 10.5%; moderate, 2.9%; and severe, 2.5%). Multivariate analysis, including age, left ventricular hypertrophy, and mitral annular calcification, revealed that only mitral annular calcification was independently and significantly associated with progression to AS. CONCLUSIONS: Aortic valve thickening without stenosis is common, and it may progress to significant AS. It is possible that this development of AS may be responsible for some of the increased morbidity and mortality in patients with AVT.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Válvula Aórtica/diagnóstico por imagen , Cardiomegalia/complicaciones , Cardiomegalia/diagnóstico por imagen , Anciano , Estenosis de la Válvula Aórtica/mortalidad , Cardiomegalia/mortalidad , Estudios de Cohortes , Ecocardiografía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Oportunidad Relativa , Medición de Riesgo , Tasa de Supervivencia , Factores de Tiempo
15.
Echocardiography ; 16(6): 595-602, 1999 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-11175197

RESUMEN

The recent development of endovascular catheters that are placed via the femoral artery and vein has enabled patients to be placed on cardiopulmonary bypass without the need for direct visualization of the heart or great vessels via sternotomy. This has allowed cardiac surgery to be performed through smaller, thoracotomy incisions. Placement of these catheters initially was performed under fluoroscopic guidance, which has major imaging limitations. Now, transesophageal echocardiography (TEE) has replaced fluoroscopy as the primary imaging technique to assist in the placement of endovascular catheters during minimally invasive, port-access cardiac surgery. In our institution, 449 port-access procedures have been performed from May 1996 through July 1998. We found that TEE is able to adequately visualize the cardiac structures and assist in the placement of the endovascular catheters in all patients. Fluoroscopy is helpful only as an aid to the use of TEE for placement of the coronary sinus catheter.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...