Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38885105

RESUMEN

Cough is an important symptom in children with acute and chronic respiratory disease. Daily cough is common in Cystic Fibrosis (CF) and increased cough is a symptom of pulmonary exacerbation. To date, cough assessment is primarily subjective in clinical practice and research. Attempts to develop objective, automatic cough counting tools have faced reliability issues in noisy environments and practical barriers limiting long-term use. This single-center pilot study evaluated usability, acceptability and performance of a mechanoacoustic sensor (MAS), previously used for cough classification in adults, in 36 children with CF over brief and multi-day periods in four cohorts. Children whose health was at baseline and who had symptoms of pulmonary exacerbation were included. We trained, validated, and deployed custom deep learning algorithms for accurate cough detection and classification from other vocalization or artifacts with an overall area under the receiver-operator characteristic curve (AUROC) of 0.96 and average precision (AP) of 0.93. Child and parent feedback led to a redesign of the MAS towards a smaller, more discreet device acceptable for daily use in children. Additional improvements optimized power efficiency and data management. The MAS's ability to objectively measure cough and other physiologic signals across clinic, hospital, and home settings is demonstrated, particularly aided by an AUROC of 0.97 and AP of 0.96 for motion artifact rejection. Examples of cough frequency and physiologic parameter correlations with participant-reported outcomes and clinical measurements for individual patients are presented. The MAS is a promising tool in objective longitudinal evaluation of cough in children with CF.

2.
Nat Biomed Eng ; 7(10): 1229-1241, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37783757

RESUMEN

Cardiovascular health is typically monitored by measuring blood pressure. Here we describe a wireless on-skin system consisting of synchronized sensors for chest electrocardiography and peripheral multispectral photoplethysmography for the continuous monitoring of metrics related to vascular resistance, cardiac output and blood-pressure regulation. We used data from the sensors to train a support-vector-machine model for the classification of haemodynamic states (resulting from exposure to heat or cold, physical exercise, breath holding, performing the Valsalva manoeuvre or from vasopressor administration during post-operative hypotension) that independently affect blood pressure, cardiac output and vascular resistance. The model classified the haemodynamic states on the basis of an unseen subset of sensor data for 10 healthy individuals, 20 patients with hypertension undergoing haemodynamic stimuli and 15 patients recovering from cardiac surgery, with an average precision of 0.878 and an overall area under the receiver operating characteristic curve of 0.958. The multinodal sensor system may provide clinically actionable insights into haemodynamic states for use in the management of cardiovascular disease.


Asunto(s)
Fotopletismografía , Dispositivos Electrónicos Vestibles , Humanos , Hemodinámica/fisiología , Presión Sanguínea/fisiología , Electrocardiografía
3.
J Orthop Res ; 41(1): 54-62, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35384025

RESUMEN

Serial examination and direct measurement of intracompartmental pressure (ICP) are suboptimal strategies for the detection of acute compartment syndrome (CS) because they are operator-dependent and yield information that only indirectly reflects intracompartmental muscle perfusion. As a result, instances of unnecessary fasciotomy and unrecognized CS are relatively common. Recently, near-infrared spectroscopy (NIRS)-based systems for compartment monitoring have generated interest as an adjunct tool. Under ideal conditions, NIRS directly measures the oxygenation of intracompartmental muscle (StO2 ), thereby obviating the challenges of interpreting equivocal clinical examination or ICP data. Despite these potential advantages, existing NIRS sensors are plagued by technical difficulties that limit clinical utility. Most of these limitations relate to their transcutaneous design that makes them susceptible to both interference from intervening skin/subcutaneous tissue, underlying hematoma, and instability of the skin-sensor interface. Here, we present a flexible, wireless, Bluetooth-enabled, percutaneously introducible intramuscular NIRS device that directly and continuously measures the StO2 of intracompartmental muscle. Proof of concept for this device is demonstrated in a swine lower extremity balloon compression model of acute CS, wherein we simultaneously track muscle oxygenation, ICP, and compartment perfusion pressure (PP). The observed StO2 decreased with increasing ICP and decreasing PP and then recovered following pressure reduction. The mean change in StO2 as the PP was decreased from baseline to 30 mmHg was -7.6%. The mean difference between baseline and nadir StO2 was -17.4%. Cross-correlations (absolute value) describing the correspondence between StO2 and ICP were >0.73. This novel intramuscular NIRS device identifies decreased muscle perfusion in the setting of evolving CS.


Asunto(s)
Síndromes Compartimentales , Espectroscopía Infrarroja Corta , Porcinos , Animales , Músculos , Síndromes Compartimentales/diagnóstico
4.
J Reconstr Microsurg ; 39(3): 231-237, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35952677

RESUMEN

BACKGROUND: Commercially available near infrared spectroscopy devices for continuous free flap tissue oxygenation (StO2) monitoring can only be used on flaps with a cutaneous component. Additionally, differences in skin quality and pigmentation may alter StO2 measurements. Here, we present a novel implantable heat convection probe that measures microvascular blood flow for peripheral monitoring of free flaps, and is not subject to the same issues that limit the clinical utility of near-infrared spectroscopy. METHODS: The intratissue microvascular flow-sensing device includes a resistive heater, 4 thermistors, a small battery, and a Bluetooth chip, which allows connection to a smart device. Convection of applied heat is measured and mathematically transformed into a measurement of blood flow velocity. This was tested alongside Vioptix T.Ox in a porcine rectus abdominis myocutaneous flap model of arterial and venous occlusion. After flap elevation, the thermal device was deployed intramuscularly, and the cutaneous T.Ox device was applied. Acland clamps were alternately applied to the flap artery and veins to achieve 15 minutes periods of flap ischemia and congestion with a 15 minutes intervening recovery period. In total, five devices were tested in three flaps in three separate pigs over 16 vaso-occlusive events. RESULTS: Flow measurements were responsive to both ischemia and congestion, and returned to baseline during recovery periods. Flow measurements corresponded closely with measured StO2. Cross-correlation at zero lag showed agreement between these two sensing modalities. Two novel devices tested simultaneously on the same flap showed only minor variations in flow measurements. CONCLUSION: This novel probe is capable of detecting changes in tissue microcirculatory blood flow. This device performed well in a swine model of flap ischemia and congestion, and shows promise as a potentially useful clinical tool. Future studies will investigate performance in fasciocutaneous flaps and characterize longevity of the device over a period of several days.


Asunto(s)
Colgajos Tisulares Libres , Colgajo Miocutáneo , Porcinos , Animales , Microcirculación , Colgajos Tisulares Libres/irrigación sanguínea , Isquemia , Complicaciones Posoperatorias , Arterias
5.
Appl Phys Rev ; 9(4): 041307, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36467868

RESUMEN

Measurements of the thermal properties of the skin can serve as the basis for a noninvasive, quantitative characterization of dermatological health and physiological status. Applications range from the detection of subtle spatiotemporal changes in skin temperature associated with thermoregulatory processes, to the evaluation of depth-dependent compositional properties and hydration levels, to the assessment of various features of microvascular/macrovascular blood flow. Examples of recent advances for performing such measurements include thin, skin-interfaced systems that enable continuous, real-time monitoring of the intrinsic thermal properties of the skin beyond its superficial layers, with a path to reliable, inexpensive instruments that offer potential for widespread use as diagnostic tools in clinical settings or in the home. This paper reviews the foundational aspects of the latest thermal sensing techniques with applicability to the skin, summarizes the various devices that exploit these concepts, and provides an overview of specific areas of application in the context of skin health. A concluding section presents an outlook on the challenges and prospects for research in this field.

6.
NPJ Digit Med ; 5(1): 147, 2022 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-36123384

RESUMEN

Swallowing is a complex neuromuscular activity regulated by the autonomic nervous system. Millions of adults suffer from dysphagia (impaired or difficulty swallowing), including patients with neurological disorders, head and neck cancer, gastrointestinal diseases, and respiratory disorders. Therapeutic treatments for dysphagia include interventions by speech-language pathologists designed to improve the physiology of the swallowing mechanism by training patients to initiate swallows with sufficient frequency and during the expiratory phase of the breathing cycle. These therapeutic treatments require bulky, expensive equipment to synchronously record swallows and respirations, confined to use in clinical settings. This paper introduces a wireless, wearable technology that enables continuous, mechanoacoustic tracking of respiratory activities and swallows through movements and vibratory processes monitored at the skin surface. Validation studies in healthy adults (n = 67) and patients with dysphagia (n = 4) establish measurement equivalency to existing clinical standard equipment. Additional studies using a differential mode of operation reveal similar performance even during routine daily activities and vigorous exercise. A graphical user interface with real-time data analytics and a separate, optional wireless module support both visual and haptic forms of feedback to facilitate the treatment of patients with dysphagia.

7.
Sci Adv ; 8(23): eabo0537, 2022 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-35687686

RESUMEN

Continuous health monitoring is essential for clinical care, especially for patients in neonatal and pediatric intensive care units. Monitoring currently requires wired biosensors affixed to the skin with strong adhesives that can cause irritation and iatrogenic injuries during removal. Emerging wireless alternatives are attractive, but requirements for skin adhesives remain. Here, we present a materials strategy enabling wirelessly triggered reductions in adhesive strength to eliminate the possibility for injury during removal. The materials involve silicone composites loaded with crystallizable oils with melting temperatures close to, but above, surface body temperature. This solid/liquid phase transition occurs upon heating, reducing the adhesion at the skin interface by more than 75%. Experimental and computational studies reveal insights into effects of oil mixed randomly and patterned deterministically into the composite. Demonstrations in skin-integrated sensors that include wirelessly controlled heating and adhesion reduction illustrate the broad utility of these ideas in clinical-grade health monitoring.

8.
Nat Commun ; 13(1): 3009, 2022 05 30.
Artículo en Inglés | MEDLINE | ID: mdl-35637230

RESUMEN

Continuous, real-time monitoring of perfusion after microsurgical free tissue transfer or solid organ allotransplantation procedures can facilitate early diagnosis of and intervention for anastomotic thrombosis. Current technologies including Doppler systems, cutaneous O2-sensing probes, and fluorine magnetic resonance imaging methods are limited by their intermittent measurements, requirements for skilled personnel, indirect interfaces, and/or their tethered connections. This paper reports a wireless, miniaturized, minimally invasive near-infrared spectroscopic system designed for uninterrupted monitoring of local-tissue oxygenation. A bioresorbable barbed structure anchors the probe stably at implantation sites for a time period matched to the clinical need, with the ability for facile removal afterward. The probe connects to a skin-interfaced electronic module for wireless access to essential physiological parameters, including local tissue oxygenation, pulse oxygenation, and heart rate. In vitro tests and in vivo studies in porcine flap and kidney models demonstrate the ability of the system to continuously measure oxygenation with high accuracy and sensitivity.


Asunto(s)
Saturación de Oxígeno , Trasplantes , Animales , Prótesis e Implantes , Piel/diagnóstico por imagen , Espectroscopía Infrarroja Corta/métodos , Porcinos
9.
Biosens Bioelectron ; 206: 114145, 2022 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-35278852

RESUMEN

Vascular pedicle thrombosis after free flap transfer or solid organ transplantation surgeries can lead to flap necrosis, organ loss requiring re-transplantation, or even death. Although implantable flow sensors can provide early warning of malperfusion and facilitate operative salvage, measurements performed with existing technologies often depend on extrinsic conditions such as mounting methods and environmental fluctuations. Furthermore, the mechanisms for fixing such probes to vascular or skeletal structures may disrupt the normal blood flow or cause unnecessary tissue damage. Requirements for wired connections to benchtop readout systems also increase costs, complicate clinical care and constrain movements of the patient. Here, we report a wireless, miniaturized flow sensing system that exploits sub-millimeter scale, multi-nodal thermal probes, with biodegradable barbs that secure the probes to the surrounding tissues in a manner that facilitates removal after a period of use. These smartphone-readable devices, together with experimentally validated analytical models of the thermal transport physics, enable reliable, accurate flow sensing in ways that are largely immune to variations in temperature and mechanical perturbations. In vivo demonstrations of this technology in porcine myocutaneous flap and kidney malperfusion models highlight the essential capabilities in microsurgical and transplantation-related biomedical application scenarios.


Asunto(s)
Técnicas Biosensibles , Trasplantes , Animales , Humanos , Microcirculación , Prótesis e Implantes , Porcinos
10.
J Reconstr Microsurg ; 38(4): 321-327, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34553344

RESUMEN

BACKGROUND: Current near-infrared spectroscopy (NIRS)-based systems for continuous flap monitoring are limited to flaps which carry a cutaneous paddle. As such, this useful and reliable technology has not previously been applicable to muscle-only free flaps where other modalities with substantial limitations continue to be utilized. METHODS: We present the first NIRS probe which allows continuous monitoring of local tissue oxygen saturation (StO2) directly within the substance of muscle tissue. This probe is flexible, subcentimeter in scale, waterproof, biocompatible, and is fitted with resorbable barbs which facilitate temporary autostabilization followed by easy atraumatic removal. This novel device was compared with a ViOptix T.Ox monitor in a porcine rectus abdominus myocutaneous flap model of arterial and venous occlusions. During these experiments, the T.Ox device was affixed to the skin paddle, while the novel probe was within the muscle component of the same flap. RESULTS: The intramuscular NIRS device and skin-mounted ViOptix T.Ox devices produced very similar StO2 tracings throughout the vascular clamping events, with obvious and parallel changes occurring upon vascular clamping and release. The normalized cross-correlation at zero lag describing correspondence between the novel intramuscular NIRS and T.Ox devices was >0.99. CONCLUSION: This novel intramuscular NIRS probe offers continuous monitoring of oxygen saturation within muscle flaps. This experiment demonstrates the potential suitability of this intramuscular NIRS probe for the task of muscle-only free flap monitoring, where NIRS has not previously been applicable. Testing in the clinical environment is necessary to assess durability and reliability.


Asunto(s)
Colgajo Miocutáneo , Procedimientos de Cirugía Plástica , Animales , Músculos , Oxígeno , Reproducibilidad de los Resultados , Espectroscopía Infrarroja Corta/métodos , Porcinos
11.
Proc Natl Acad Sci U S A ; 118(20)2021 05 18.
Artículo en Inglés | MEDLINE | ID: mdl-33972445

RESUMEN

Vital signs monitoring is a fundamental component of ensuring the health and safety of women and newborns during pregnancy, labor, and childbirth. This monitoring is often the first step in early detection of pregnancy abnormalities, providing an opportunity for prompt, effective intervention to prevent maternal and neonatal morbidity and mortality. Contemporary pregnancy monitoring systems require numerous devices wired to large base units; at least five separate devices with distinct user interfaces are commonly used to detect uterine contractility, maternal blood oxygenation, temperature, heart rate, blood pressure, and fetal heart rate. Current monitoring technologies are expensive and complex with implementation challenges in low-resource settings where maternal morbidity and mortality is the greatest. We present an integrated monitoring platform leveraging advanced flexible electronics, wireless connectivity, and compatibility with a wide range of low-cost mobile devices. Three flexible, soft, and low-profile sensors offer comprehensive vital signs monitoring for both women and fetuses with time-synchronized operation, including advanced parameters such as continuous cuffless blood pressure, electrohysterography-derived uterine monitoring, and automated body position classification. Successful field trials of pregnant women between 25 and 41 wk of gestation in both high-resource settings (n = 91) and low-resource settings (n = 485) demonstrate the system's performance, usability, and safety.


Asunto(s)
Monitoreo Fisiológico/instrumentación , Embarazo/fisiología , Dispositivos Electrónicos Vestibles , Tecnología Inalámbrica/instrumentación , Femenino , Recursos en Salud , Frecuencia Cardíaca Fetal , Humanos , Contracción Uterina , Signos Vitales
12.
NPJ Digit Med ; 3: 29, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32195364

RESUMEN

Hydrocephalus is a common disorder caused by the buildup of cerebrospinal fluid (CSF) in the brain. Treatment typically involves the surgical implantation of a pressure-regulated silicone tube assembly, known as a shunt. Unfortunately, shunts have extremely high failure rates and diagnosing shunt malfunction is challenging due to a combination of vague symptoms and a lack of a convenient means to monitor flow. Here, we introduce a wireless, wearable device that enables precise measurements of CSF flow, continuously or intermittently, in hospitals, laboratories or even in home settings. The technology exploits measurements of thermal transport through near-surface layers of skin to assess flow, with a soft, flexible, and skin-conformal device that can be constructed using commercially available components. Systematic benchtop studies and numerical simulations highlight all of the key considerations. Measurements on 7 patients establish high levels of functionality, with data that reveal time dependent changes in flow associated with positional and inertial effects on the body. Taken together, the results suggest a significant advance in monitoring capabilities for patients with shunted hydrocephalus, with potential for practical use across a range of settings and circumstances, and additional utility for research purposes in studies of CSF hydrodynamics.

13.
Nat Med ; 26(3): 418-429, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32161411

RESUMEN

Standard clinical care in neonatal and pediatric intensive-care units (NICUs and PICUs, respectively) involves continuous monitoring of vital signs with hard-wired devices that adhere to the skin and, in certain instances, can involve catheter-based pressure sensors inserted into the arteries. These systems entail risks of causing iatrogenic skin injuries, complicating clinical care and impeding skin-to-skin contact between parent and child. Here we present a wireless, non-invasive technology that not only offers measurement equivalency to existing clinical standards for heart rate, respiration rate, temperature and blood oxygenation, but also provides a range of important additional features, as supported by data from pilot clinical studies in both the NICU and PICU. These new modalities include tracking movements and body orientation, quantifying the physiological benefits of skin-to-skin care, capturing acoustic signatures of cardiac activity, recording vocal biomarkers associated with tonality and temporal characteristics of crying and monitoring a reliable surrogate for systolic blood pressure. These platforms have the potential to substantially enhance the quality of neonatal and pediatric critical care.


Asunto(s)
Técnicas Biosensibles , Unidades de Cuidado Intensivo Neonatal , Unidades de Cuidado Intensivo Pediátrico , Monitoreo Fisiológico , Piel/anatomía & histología , Tecnología Inalámbrica , Monitoreo Ambulatorio de la Presión Arterial , Niño , Preescolar , Electrocardiografía , Diseño de Equipo , Humanos , Recién Nacido , Fotopletismografía , Factores de Tiempo
14.
Nat Biomed Eng ; 4(2): 148-158, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31768002

RESUMEN

Skin-mounted soft electronics that incorporate high-bandwidth triaxial accelerometers can capture broad classes of physiologically relevant information, including mechano-acoustic signatures of underlying body processes (such as those measured by a stethoscope) and precision kinematics of core-body motions. Here, we describe a wireless device designed to be conformally placed on the suprasternal notch for the continuous measurement of mechano-acoustic signals, from subtle vibrations of the skin at accelerations of around 10-3 m s-2 to large motions of the entire body at about 10 m s-2, and at frequencies up to around 800 Hz. Because the measurements are a complex superposition of signals that arise from locomotion, body orientation, swallowing, respiration, cardiac activity, vocal-fold vibrations and other sources, we exploited frequency-domain analysis and machine learning to obtain-from human subjects during natural daily activities and exercise-real-time recordings of heart rate, respiration rate, energy intensity and other essential vital signs, as well as talking time and cadence, swallow counts and patterns, and other unconventional biomarkers. We also used the device in sleep laboratories and validated the measurements using polysomnography.


Asunto(s)
Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Fenómenos Fisiológicos , Tecnología Inalámbrica/instrumentación , Clavícula , Diseño de Equipo , Ejercicio Físico/fisiología , Humanos , Procesamiento de Señales Asistido por Computador , Fenómenos Fisiológicos de la Piel , Sueño/fisiología , Vibración
15.
Biosens Bioelectron ; 117: 153-160, 2018 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-29894852

RESUMEN

An effective method of combating infectious diseases is the deployment of hand-held devices at the point-of-care (POC) for screening or self-monitoring applications. There is a need for very sensitive, low-cost and quantitative diagnostic devices. In this study, we present a low-cost, multiplexed fluorescence detection platform that has a high sensitivity and wide dynamic range. Our system features inexpensive 3 × 3 mm interference filters with a high stopband rejection, sharp transition edges, and greater than 90% transmission in the passband. In addition to the filters, we improve signal-to-noise ratio by leveraging time for accuracy using a charge-integration-based readout. The fluorescence sensing platform provides a sensitivity to photon flux of ∼1×104photons/mm2sec and has the potential for 2-3 orders of magnitude improvement in sensitivity over standard colorimetric detection that uses colored latex microspheres. We also detail the design, development, and characterization of our low-cost fluorescence detection platform and demonstrate 100% and 97.96% reduction in crosstalk probability and filter cost, respectively. This is achieved by reducing filter dimensions and ensuring appropriate channel isolation in a 2 × 2 array configuration. Practical considerations with low-cost interference filter system design, analysis, and system performance are also discussed. The performance of our platform is compared to that of a standard laboratory array scanner. We also demonstrate the detection of antibodies to human papillomavirus (HPV16) E7 protein, as a potential biomarker for early cervical cancer detection in human plasma.


Asunto(s)
Anticuerpos/sangre , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Detección Precoz del Cáncer/instrumentación , Detección Precoz del Cáncer/métodos , Neoplasias del Cuello Uterino/diagnóstico , Biomarcadores/sangre , Colorimetría/normas , Femenino , Humanos , Proteínas E7 de Papillomavirus/inmunología , Sistemas de Atención de Punto
16.
Artículo en Inglés | MEDLINE | ID: mdl-25570559

RESUMEN

We presents an ion sensitive field effect transistor to measure the pH of the cell culture media of human mammary adenocarcinoma (SKBR3). We use a drift mitigation technique that cycles the transistor to reset the drift in the system. We use to technique in the system to demonstrate an integrated system to monitor the pH continuously. As a part of the system a pulse width modulation circuit is designed in a 0.5 µm CMOS process which cycles the vertical electric field of the ion sensitive field effect transistor to reset the threshold voltage drift. We demonstrate the viability of a complete integrated system implementing our drift mitigation technique to monitor cultured cells. The integration is important in this application to allow for autonomous operation inside an incubator during cell culture.


Asunto(s)
Técnicas de Cultivo de Célula/instrumentación , Técnicas de Cultivo de Célula/métodos , Medios de Cultivo/química , Línea Celular Tumoral , Medios de Cultivo/análisis , Diseño de Equipo , Humanos , Concentración de Iones de Hidrógeno , Semiconductores , Procesamiento de Señales Asistido por Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...