RESUMEN
INTRODUCTION: People in need of care or support are severely affected by the COVID-19 pandemic. We lack valid data of long-term assessments. We present a register study to detect the physical and psychosocial impact of the COVID-19 pandemic on people in need of care or support in Bavaria, Germany. To describe the persons' life conditions comprehensively, we assess the perspectives and needs of the respective care teams too. Results will serve as evidence-based source to manage the pandemic and long-term prevention strategies. METHODS AND ANALYSIS: The 'Bavarian ambulatory COVID-19 Monitor' is a multicentre registry including a purposive sample of up to 1000 patient-participants across three study sites in Bavaria. The study group consists of 600 people in need of care with a positive SARS-CoV-2 PCR test. Control group 1 comprises 200 people in need of care with a negative SARS-CoV-2 PCR test, while control group 2 comprises 200 people with a positive SARS-CoV-2 PCR test but are not in need of care. We assess the clinical course of infection, psychosocial aspects and care needs using validated measures. Follow-up is every 6 months for up to 3 years. Additionally, we assess up to 400 people linked to these patient-participants (caregivers, general practitioners (GPs)) for their health and needs. Main analyses are stratified by level of care I-V (I=minor/V=most severe impairment of independence), inpatient/outpatient care setting, sex and age. We use descriptive and inferential statistics to analyse cross-sectional data and changes over time. In qualitative interviews with 60 stakeholders (people in need of care, caregivers, GPs, politicians), we explore interface problems of different functional logics, of everyday and professional perspectives. ETHICS AND DISSEMINATION: The Institutional Review Board of the University Hospital LMU Munich (#20-860) and the study sites (Universities of Wurzburg and Erlangen) approved the protocol. We disseminate the results by peer-reviewed publications, international conferences, governmental reports, etc.
Asunto(s)
COVID-19 , Humanos , COVID-19/epidemiología , SARS-CoV-2 , Pandemias/prevención & control , Estudios Transversales , Pacientes AmbulatoriosRESUMEN
Short-term studies have shown an attenuated immune response in hemodialysis patients after COVID-19-vaccination. The present study examines how antibody response is maintained after vaccination against SARS-CoV-2 in a large population of hemodialysis patients from six outpatient dialysis centers. We retrospectively assessed serum antibody levels against SARS-CoV-2 spike protein and nucleocapsid protein (electrochemiluminescence immunoassays, Roche Diagnostics) after COVID-19-vaccination in 298 hemodialysis and 103 non-dialysis patients (controls), comparing early and late antibody response. Compared to a non-dialysis cohort hemodialysis patients showed a favorable but profoundly lower early antibody response, which decreased substantially during follow-up measurement (median 6 months after vaccination). Significantly more hemodialysis patients had anti-SARS-CoV-2-S antibody titers below 100 U/mL (p < 0.001), which increased during follow-up from 23% to 45% but remained low in the control group (3% vs. 7%). In multivariate analysis, previous COVID-19 infections (p < 0.001) and female gender (p < 0.05) were significantly associated with higher early as well as late antibody vaccine response in hemodialysis patients, while there was a significant inverse correlation between patient age and systemic immunosuppression (p < 0.001). The early and late antibody responses were significantly higher in patients receiving vaccination after a SARS-CoV-2 infection compared to uninfected patients in both groups (p < 0.05). We also note that a higher titer after complete immunization positively affected late antibody response. The observation, that hemodialysis patients showed a significantly stronger decline of SARS-CoV-2 vaccination antibody titers within 6 months, compared to controls, supports the need for booster vaccinations to foster a stronger and more persistent antibody response.
RESUMEN
BACKGROUND: Some studies have shown an attenuated immune response in haemodialysis patients after vaccination. The present study examines the humoral response after mRNA vaccination against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in a large population of haemodialysis patients from different outpatient dialysis centres. METHODS: We retrospectively assessed antibodies against SARS-CoV-2 spike protein and nucleocapsid protein (chemiluminescence immunoassays, Roche diagnostics) 3-6 weeks after the second mRNA vaccine dose in 179 maintenance haemodialysis and 70 non-dialysis patients (control cohort). Differences in anti-SARS-CoV-2 spike protein titers were statistically analysed with respect to patient-relevant factors, including age, gender, previous coronavirus disease 2019 (COVID-19) infection, systemic immunosuppressive therapy and time on dialysis. RESULTS: We found a favourable, but profoundly lower SARS-CoV-2 spike protein antibody response in comparison with a non-dialysis cohort (median 253.5 versus 1756 U/mL, P < 0.001). In multivariate analysis, previous COVID-19 infection (P < 0.001) and female gender were associated with a significantly higher vaccine response (P = 0.006) in haemodialysis patients, while there was a significant inverse correlation with increasing patient age and systemic immunosuppression (P < 0.001). There was no statistically significant correlation between the antibody titer and time on dialysis. Immune response in haemodialysis patients with a previous COVID-19 infection led to substantially higher antibody titers that were equal to those of vaccinated non-dialysis individuals with previous infection. CONCLUSION: We strongly argue in favour of regular antibody testing after COVID-19 vaccination in haemodialysis patients. Further studies should elucidate the utility of booster vaccinations to foster a stronger and persistent antibody response.
RESUMEN
Several studies have addressed the poor stability of meropenem in aqueous solutions, though not considering the main degradation product, the open-ring metabolite (ORM) form. In the present work, we elucidate the metabolic fate of meropenem and ORM from continuous infusion to the human bloodstream. We performed in vitro infusate stability tests at ambient temperature with 2% meropenem reconstituted in 0.9% normal saline, and body temperature warmed buffered human serum with 2, 10, and 50 mg/L meropenem, covering the therapeutic range. We also examined meropenem and ORM levels over several days in six critically ill patients receiving continuous infusions. Meropenem exhibited a constant degradation rate of 0.006/h and 0.025/h in normal saline at 22 °C and serum at 37 °C, respectively. Given that 2% meropenem remains stable for 17.5 h in normal saline (≥90% of the initial concentration), we recommend replacement of the infusate every 12 h. Our patients showed inter-individually highly variable, but intra-individually constant molar ORM/(meropenem + ORM) ratios of 0.21-0.52. Applying a population pharmacokinetic approach using the degradation rate in serum, spontaneous degradation accounted for only 6% of the total clearance.
RESUMEN
A deeper understanding of COVID-19 on human molecular pathophysiology is urgently needed as a foundation for the discovery of new biomarkers and therapeutic targets. Here we applied mass spectrometry (MS)-based proteomics to measure serum proteomes of COVID-19 patients and symptomatic, but PCR-negative controls, in a time-resolved manner. In 262 controls and 458 longitudinal samples of 31 patients, hospitalized for COVID-19, a remarkable 26% of proteins changed significantly. Bioinformatics analyses revealed co-regulated groups and shared biological functions. Proteins of the innate immune system such as CRP, SAA1, CD14, LBP, and LGALS3BP decreased early in the time course. Regulators of coagulation (APOH, FN1, HRG, KNG1, PLG) and lipid homeostasis (APOA1, APOC1, APOC2, APOC3, PON1) increased over the course of the disease. A global correlation map provides a system-wide functional association between proteins, biological processes, and clinical chemistry parameters. Importantly, five SARS-CoV-2 immunoassays against antibodies revealed excellent correlations with an extensive range of immunoglobulin regions, which were quantified by MS-based proteomics. The high-resolution profile of all immunoglobulin regions showed individual-specific differences and commonalities of potential pathophysiological relevance.
Asunto(s)
COVID-19 , Proteoma , Anticuerpos Antivirales , Arildialquilfosfatasa , Humanos , Proteómica , SARS-CoV-2 , SeroconversiónRESUMEN
OBJECTIVES: During the COVID-19 pandemic, SARS-CoV-2 antibody testing has been suggested for (1) screening populations for disease prevalence, (2) diagnostics, and (3) guiding therapeutic applications. Here, we conducted a detailed clinical evaluation of four Anti-SARS-CoV-2 immunoassays in samples from acutely ill COVID-19 patients and in two negative cohorts. METHODS: 443 serum specimens from serial sampling of 29 COVID-19 patients were used to determine clinical sensitivities. Patients were stratified for the presence of acute respiratory distress syndrome (ARDS). Individual serum specimens from a pre-COVID-19 cohort of 238 healthy subjects and from a PCR-negative clinical cohort of 257 patients were used to determine clinical specificities. All samples were measured side-by-side with the Anti-SARS-CoV-2-ELISA (IgG), Anti-SARS-CoV-2-ELISA (IgA) and Anti-SARS-CoV-2-NCP-ELISA (IgG) (Euroimmun AG, Lübeck, Germany) and the Elecsys Anti-SARS-CoV-2 ECLIA (Roche Diagnostics International, Rotkreuz, Switzerland). RESULTS: Median seroconversion occurred earlier in ARDS patients (8-9 days) than in non-ARDS patients (11-17 days), except for EUR N-IgG. Rates of positivity and mean signal ratios in the ARDS group were significantly higher than in the non-ARDS group. Sensitivities between the four tested immunoassays were equivalent. In the set of negative samples, the specificity of the Anti-SARS-CoV-2-ELISA (IgA) was lower (93.9%) compared to all other assays (≥98.8%) and the specificity of Anti-SARS-CoV-2-NCP-ELISA (IgG) was lower (98.8%) than that of Elecsys Anti-SARS-CoV-2 (100%). CONCLUSIONS: Serial sampling in COVID-19 patients revealed earlier seroconversion and higher signal ratios of SARS-CoV-2 antibodies as a potential risk marker for the development of ARDS, suggesting a utility for antibody testing in acutely diseased patients.