Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Intervalo de año de publicación
1.
Braz. j. oral sci ; 19: e201704, jan.-dez. 2020. ilus
Artículo en Inglés | BBO, LILACS | ID: biblio-1116338

RESUMEN

Aim: The aim of this study was to evaluate the influence of the translucency of ceramic on water sorption and solubility of resin cements over time. Methods: Lithium disilicate ceramic slides (15x15x1 mm), A1 in color and with different translucencies (high-medium-low) were manufactured; and a glass slide with similar dimension was used as control. Under every slide, 15 specimens (8x0.5 mm) from each resin cement were prepared: light-cured (RelyX Veneer); conventional dual-cured (RelyX ARC); and self-adhesive dual-cured (Rely-X U200). The specimens were then sub-divided according to the period of evaluation (immediately, after 6 and 12 months of storage) (n=5). To evaluate the loss or gain of mass, the specimens were dried until a constant mass was reached. Subsequently, they were divided according to the respective period of storage at 37°C in distilled water and weighed immediately following removal from water. After each period, specimens underwent a new dehydration. Values from water sorption and solubility were calculated and statistically analyzed (Anova 3-way/Tukey test). Results: The lower translucency resulted in greater water sorption and solubility for all cements, regardless of the experimental period. The self-adhesive dual-cured cement showed higher water sorption under all experimental periods and had worse values after 1 year aging. Differences among solubility could only be detected after aging, and the light-cured material had higher values after 6 and 12 months. Conclusions: It could be concluded that the low degree of translucency can negatively influence the passage of light and interfere on the durability of the resin cement. The conventional dual-cured resinous agent seemed to be less affected by such condition


Asunto(s)
Solubilidad , Cerámica , Restauración Dental Permanente , Auto-Curación de Resinas Dentales
2.
Dent Mater J ; 34(1): 1-6, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-24998169

RESUMEN

The purpose of this study was to evaluate the influence of storage temperature and flask agitation on the water sorption (WS) and solubility (SL) of simplified adhesive systems. Seventy-two disc-shaped specimens were prepared according to the adhesive system (water/ethanol-based: Adper Single Bond 2; and water-based: One Coat Bond SL) and experimental conditions tested (mechanical agitation and storage temperature). Statistical analysis (3-way ANOVA, alpha=5%) found significantly greater WS and SL means for the water/ethanol-based system when compared to the water-based. Irrespective of factors studied, significant differences in WS and SL were noted between cold and room temperatures, with greater values been obtained at 1°C, and lower ones at 20°C. Agitation provided increased WS for both materials at all temperatures, but did not affect their SL. The mechanical agitation of the flask may negatively affect the dynamics of diffusion of simplified adhesive systems, even at extremely cold or warm temperatures.


Asunto(s)
Cementos Dentales/química , Metacrilatos/química , Cementos de Resina/química , Agua/química , Ensayo de Materiales , Solubilidad , Propiedades de Superficie , Temperatura
3.
Acta Odontol Latinoam ; 25(1): 109-14, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22928390

RESUMEN

This study evaluated the influence of the prolonged setting time of an ethanol-based adhesive system on the dentin bond strength and degree of conversion. Labial and lingual surfaces of fifteen human third molars were flattened until the dentin was exposed and randomly allocated to 3 groups (n = 10), according to the dwell time between the application of two consecutive layers of the adhesive system (Adper Single Bond Plus, 3M ESPE) and light activation: G1--control (no extra dwell time); G2 and G3--dwell time of 30 seconds and 60 seconds, respectively. After light curing, two cylinders (1.4 x 1 mm) of composite resin (Filtek Flow, 3M ESPE) were bonded to each surface and submitted to micro-shear testing, 24 hours after light curing. A similar adhesive procedure was used for the degree of conversion evaluation using Fourier transform infrared spectroscopy (FTIR). Significant differences between bond strength values (p = 0.0003) and degrees of conversion (p = 0.0004) were detected. The bond strength of G3 (60-second dwell time) was statistically higher than that of other groups. G1 (control) and G2 (30-second dwell time) presented similar results. Values of degree of conversion indicated that both the 30-second and 60-second dwell times resulted in similar and greater percentages of conversion. The use of a longer dwell time (60 seconds) might provide better solvent volatilization and monomer infiltration; bringing benefits to dentin bonding using simplified etch & rinse adhesive systems.


Asunto(s)
Recubrimiento Dental Adhesivo , Recubrimientos Dentinarios , Solventes , Resinas Compuestas , Etanol , Humanos , Técnicas In Vitro , Resistencia al Corte , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...