Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Chemosphere ; 247: 125933, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32079055

RESUMEN

Toxicity Identification Evaluation (TIE) is a useful method for the classification and identification of toxicants in a composite environment water sample. However, its extension to a larger sample size has been restrained owing to the limited throughput of toxicity bioassays. Here we reported the development of a high-throughput method of TIE Phase I. This newly developed method was assisted by the fluorescence-based cellular oxidation (CO) biosensor fabricated with roGFP2-expressing bacterial cells in 96-well microplate format. The assessment of four river water samples from Langat river basin by this new method demonstrated that the contaminant composition of the four samples can be classified into two distinct groups. The entire toxicity assay consisted of 2338 tests was completed within 12 h with a fluorescence microplate reader. Concurrently, the sample volume for each assay was reduced to 50 µL, which is 600 to 4700 times lesser to compare with conventional bioassays. These imply that the throughput of the CO biosensor-assisted TIE Phase I is now feasible for constructing a large-scale toxicity monitoring system, which would cover a whole watershed scale.


Asunto(s)
Técnicas Biosensibles , Pruebas de Toxicidad/métodos , Contaminantes Químicos del Agua/toxicidad , Bioensayo , Monitoreo del Ambiente/métodos , Agua Dulce , Sustancias Peligrosas , Ríos/química , Contaminantes Químicos del Agua/análisis
2.
Chemosphere ; 120: 299-304, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25151133

RESUMEN

The aquatic ecotoxicity of chemicals involved in the manufacturing process of thin film transistor liquid crystal displays was assessed with a battery of four selected acute toxicity bioassays. We focused on tetramethylammonium hydroxide (TMAH, CAS No. 75-59-2), a widely utilized etchant. The toxicity of TMAH was low when tested in the 72 h-algal growth inhibition test (Pseudokirchneriellia subcapitata, EC50=360 mg L(-1)) and the Microtox® test (Vibrio fischeri, IC50=6.4 g L(-1)). In contrast, the 24h-microcrustacean immobilization and the 96 h-fish mortality tests showed relatively higher toxicity (Daphnia magna, EC50=32 mg L(-1) and Oryzias latipes, LC50=154 mg L(-1)). Isobologram and mixture toxicity index analyses revealed apparent synergism of the mixture of TMAH and potassium iodide when examined with the D. magna immobilization test. The synergistic action was unique to iodide over other halide salts i.e. fluoride, chloride and bromide. Quaternary ammonium ions with longer alkyl chains such as tetraethylammonium and tetrabutylammonium were more toxic than TMAH in the D. magna immobilization test.


Asunto(s)
Organismos Acuáticos/efectos de los fármacos , Yoduro de Potasio/toxicidad , Compuestos de Amonio Cuaternario/toxicidad , Contaminantes Químicos del Agua/toxicidad , Aliivibrio fischeri/efectos de los fármacos , Animales , Chlorophyta/efectos de los fármacos , Daphnia/efectos de los fármacos , Sinergismo Farmacológico , Oryzias/metabolismo
3.
Sensors (Basel) ; 10(7): 6290-6306, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-22163550

RESUMEN

A highly specific, high throughput-amenable bacterial biosensor for chemically induced cellular oxidation was developed using constitutively expressed redox-sensitive green fluorescent protein roGFP2 in E. coli (E. coli-roGFP2). Disulfide formation between two key cysteine residues of roGFP2 was assessed using a double-wavelength ratiometric approach. This study demonstrates that only a few minutes were required to detect oxidation using E. coli-roGFP2, in contrast to conventional bacterial oxidative stress sensors. Cellular oxidation induced by hydrogen peroxide, menadione, sodium selenite, zinc pyrithione, triphenyltin and naphthalene became detectable after 10 seconds and reached the maxima between 80 to 210 seconds, contrary to Cd(2+), Cu(2+), Pb(2+), Zn(2+) and sodium arsenite, which induced the oxidation maximum immediately. The lowest observable effect concentrations (in ppm) were determined as 1.0 × 10(-7) (arsenite), 1.0 × 10(-4) (naphthalene), 1.0 × 10(-4) (Cu(2+)), 3.8 × 10(-4) (H(2)O(2)), 1.0 × 10(-3) (Cd(2+)), 1.0 × 10(-3) (Zn(2+)), 1.0 × 10(-2) (menadione), 1.0 (triphenyltin), 1.56 (zinc pyrithione), 3.1 (selenite) and 6.3 (Pb(2+)), respectively. Heavy metal-induced oxidation showed unclear response patterns, whereas concentration-dependent sigmoid curves were observed for other compounds. In vivo GSH content and in vitro roGFP2 oxidation assays together with E. coli-roGFP2 results suggest that roGFP2 is sensitive to redox potential change and thiol modification induced by environmental stressors. Based on redox-sensitive technology, E. coli-roGFP2 provides a fast comprehensive detection system for toxicants that induce cellular oxidation.


Asunto(s)
Fenómenos Fisiológicos Bacterianos , Técnicas Biosensibles , Proteínas Fluorescentes Verdes/metabolismo , Estrés Oxidativo , Fluorescencia , Oxidación-Reducción
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...