Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Opt Express ; 30(16): 28632-28646, 2022 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-36299054

RESUMEN

Tunable add/drop filter based optical interconnects are an integral part of data centers as well as optical communications. Although add/drop filters based on ring resonators and waveguide Bragg gratings are well developed, long period waveguide grating (LPWG) based add/drop filters have little been investigated so far. In this article, we propose an apodized LPWG assisted co-directional coupler for narrow band add/drop filtering by combining silicon (Si) waveguide with titanium dioxide (TiO2) waveguide geometry. The proposed structure has been analyzed by combining the finite element method (FEM) and transfer matrix method (TMM), showing a good side lobe suppression ratio (SLSR) equal to 25.7 dB and an insertion loss of 0.6 dB. Owing to the high group index difference of Si and TiO2 waveguides, a narrow band response of 1.4 nm has been achieved with 800µm long LPWG. The opposite thermo-optic coefficients of Si and TiO2 ensures a good thermal tunability of the central wavelength. Considering a thin metallic heater of titanium nitride (TiN) the thermal tuning efficiency is found to be 0.07 nm/mW. Further, two LPWGs have been cascaded to realize a tunable dual channel filter with a minimum channel spacing of 185 GHz and a channel crosstalk better than 20 dB, showing its potential application towards dense wavelength division multiplexing.

2.
Biosensors (Basel) ; 12(6)2022 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-35735562

RESUMEN

The measurement of small changes in the refractive index (RI) leads to a comprehensive analysis of different biochemical substances, paving the way to non-invasive and cost-effective medical diagnosis. In recent times, the liquid biopsy for cancer detection via extracellular vesicles (EV) in the bodily fluid is becoming very popular thanks to less invasiveness and stability. In this context, here we propose a highly sensitive RI sensor based on a compact high-index-coated polymer waveguide Bragg grating with a metal under cladding. Owing to the combined effect of a metal under cladding and a high-index coating, a significant enhancement in the RI sensitivity as well as the dynamic range has been observed. The proposed sensor has been analyzed by combining finite element method (FEM) and coupled-mode theory (CMT) approaches, demonstrating a sensitivity of 408-861 nm/RIU over a broad dynamic range of 1.32-1.44, and a strong evanescent field within a 150 nm proximity to the waveguide surface compliant with EV size. The aforementioned performance makes the proposed device suitable for performing real-time and on-chip diagnoses of cancer in the early stage.


Asunto(s)
Técnicas Biosensibles , Vesículas Extracelulares , Diseño de Equipo , Polímeros , Refractometría
3.
Biosensors (Basel) ; 11(10)2021 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-34677317

RESUMEN

According to the World Health Organization forecasts, AntiMicrobial Resistance (AMR) is expected to become one of the leading causes of death worldwide in the following decades. The rising danger of AMR is caused by the overuse of antibiotics, which are becoming ineffective against many pathogens, particularly in the presence of bacterial biofilms. In this context, non-destructive label-free techniques for the real-time study of the biofilm generation and maturation, together with the analysis of the efficiency of antibiotics, are in high demand. Here, we propose the design of a novel optoelectronic device based on a dual array of interdigitated micro- and nanoelectrodes in parallel, aiming at monitoring the bacterial biofilm evolution by using optical and electrical measurements. The optical response given by the nanostructure, based on the Guided Mode Resonance effect with a Q-factor of about 400 and normalized resonance amplitude of about 0.8, allows high spatial resolution for the analysis of the interaction between planktonic bacteria distributed in small colonies and their role in the biofilm generation, calculating a resonance wavelength shift variation of 0.9 nm in the presence of bacteria on the surface, while the electrical response with both micro- and nanoelectrodes is necessary for the study of the metabolic state of the bacteria to reveal the efficacy of antibiotics for the destruction of the biofilm, measuring a current change of 330 nA when a 15 µm thick biofilm is destroyed with respect to the absence of biofilm.


Asunto(s)
Biopelículas , Técnicas Biosensibles , Monitoreo del Ambiente , Antibacterianos , Bacterias , Electricidad , Humanos , Nanoestructuras
4.
Opt Express ; 23(22): 28593-604, 2015 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-26561129

RESUMEN

A multi-analyte biosensing platform with ultra-high resolution ( = 0.2 ng/mL),-which is appropriate for the detection in the human serum of a wide range of biomarkers, e.g. those allowing the lung cancer early diagnosis, has been designed. The platform is based on a new configuration of planar ring resonator. The very strong light-matter interaction enabled by the micro-cavity allows a record limit-of-detection of 0.06 pg/mm(2), five times better than the state-of-the-art. The device with footprint = 2,200 µm(2) for each ring, due to its features, has the potential to be integrated in lab-on-chip microsystems for large-scale screenings of people with high risk of developing cancer.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...