Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 224
Filtrar
1.
Jpn J Ophthalmol ; 68(3): 183-191, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38598144

RESUMEN

PURPOSE: To assess the impact of glaucoma on perceiving three-dimensional (3D) shapes based on monocular depth cues. STUDY DESIGN: Clinical observational study. METHODS: Twenty glaucoma patients, subjected to binocular visual-field sensitivity (binocular-VFS) tests using a Humphrey Visual Field Analyzer, and 20 age-matched healthy volunteers, underwent two tasks: identifying the nearest vertex of a 3D shape using monocular shading (3D-SfS), texture (3D-SfT), or motion (3D-SfM) cues, and distinguishing elementary one-dimensional (1D) features of these cues. The association of the visual-field index (VFI) of binocular-VFS with 3D shape perception in glaucoma patients was also examined. RESULTS: Glaucoma patients demonstrated reduced accuracy in distinguishing 1D luminance brightness and a larger "error-in-depth" between the perceived and actual depths for 3D-SfM and 3D-SfS compared to healthy volunteers. Six glaucoma patients with a 100% VFI for binocular-VFS exhibited a similar error-in-depth to the other fourteen glaucoma patients; they had a larger error-in-depth for 3D-SfM compared to healthy volunteers. No correlation between the error-in-depth values and the VFI values of binocular-VFS was observed. CONCLUSIONS: The 3D shape perception in glaucoma patients varies based on the depth cue's characteristics. Impaired 1D discrimination and larger thresholds for 3D-SfM in glaucoma patients with a 100% VFI for binocular-VFS indicate more pronounced perceptual deficits of lower-level elementary features for 3D-SfS and higher-level visual processing of 3D shapes for 3D-SfM. The effects of the location and degree of binocular visual-field defects on 3D shape perception remain to be elucidated. Our research provides insights into the 3D shape extraction mechanism in glaucoma.


Asunto(s)
Señales (Psicología) , Percepción de Profundidad , Glaucoma , Visión Binocular , Visión Monocular , Campos Visuales , Humanos , Masculino , Femenino , Percepción de Profundidad/fisiología , Visión Binocular/fisiología , Campos Visuales/fisiología , Persona de Mediana Edad , Anciano , Glaucoma/fisiopatología , Glaucoma/diagnóstico , Visión Monocular/fisiología , Pruebas del Campo Visual , Presión Intraocular/fisiología , Percepción de Forma/fisiología , Adulto
3.
PLoS One ; 19(2): e0298132, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38349916

RESUMEN

PURPOSE: Measurements of macular pigment optical density (MPOD) using the autofluorescence spectroscopy yield underestimations of actual values in eyes with cataracts. Previously, we proposed a correction method for this error using deep learning (DL); however, the correction performance was validated through internal cross-validation. This cross-sectional study aimed to validate this approach using an external validation dataset. METHODS: MPODs at 0.25°, 0.5°, 1°, and 2° eccentricities and macular pigment optical volume (MPOV) within 9° eccentricity were measured using SPECTRALIS (Heidelberg Engineering, Heidelberg, Germany) in 197 (training dataset inherited from our previous study) and 157 eyes (validating dataset) before and after cataract surgery. A DL model was trained to predict the corrected value from the pre-operative value using the training dataset, and we measured the discrepancy between the corrected value and the actual postoperative value. Subsequently, the prediction performance was validated using a validation dataset. RESULTS: Using the validation dataset, the mean absolute values of errors for MPOD and MPOV corrected using DL ranged from 8.2 to 12.4%, which were lower than values with no correction (P < 0.001, linear mixed model with Tukey's test). The error depended on the autofluorescence image quality used to calculate MPOD. The mean errors in high and moderate quality images ranged from 6.0 to 11.4%, which were lower than those of poor quality images. CONCLUSION: The usefulness of the DL correction method was validated. Deep learning reduced the error for a relatively good autofluorescence image quality. Poor-quality images were not corrected.


Asunto(s)
Catarata , Aprendizaje Profundo , Pigmento Macular , Humanos , Luteína , Estudios Transversales , Zeaxantinas , Catarata/terapia , Análisis Espectral
4.
Transl Vis Sci Technol ; 13(2): 2, 2024 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-38306105

RESUMEN

Purpose: To predict Humphrey Field Analyzer 24-2 test (HFA 24-2) results using 10-2 results. Methods: A total of 175 advanced glaucoma eyes (175 patients) with HFA 24-2 mean deviation (MD24-2) of < -20 dB were prospectively followed up for five years using HFA 10-2 and 24-2 (twice and once in a year, respectively). Using all the HFA 24-2 and 10-2 test result pairs measured within three months (350 pairs from 85 eyes, training dataset), a formula to predict HFA 24-2 result using HFA 10-2 results was constructed using least absolute shrinkage and selection operator regression (LASSO). Using 90 different eyes (testing dataset), the absolute differences between the actual and LASSO-predicted MD24-2 and that between the slopes calculated using five actual and LASSO-predicted MD24-2 values, were adopted as the prediction error. Similar analyses were performed for the mean total deviation values (mTD) of the superior (or inferior) hemifield [hemi-mTDsup.24-2(-hemi-mTDinf.24-2)]. Results: The prediction error for the LASSO-predicted MD24-2 and its slope were 2.98 (standard deviation [SD] = 1.90) dB and 0.32 (0.33) dB/yr, respectively. The LASSO-predicted hemi-mTDsup.24-2 (hemi-mTDinf.24-2), and its slope were 3.02 (2.89) and 3.76 (2.72) dB, and 0.37 (0.41) and 0.44 (0.38) dB/year, respectively. These prediction errors were within two times SD of repeatability of the simulated stable HFA 24-2 VF parameter series. Conclusions: HFA 24-2 results could be predicted using the paired HFA 10-2 results with reasonable accuracy using LASSO in patients with advanced glaucoma. Translational Relevance: It is useful to predict HFA24-2 test from HFA10-2 test, when the former is not available, in advanced glaucoma.


Asunto(s)
Glaucoma , Campos Visuales , Humanos , Pruebas del Campo Visual/métodos , Glaucoma/diagnóstico , Ojo
5.
PLoS One ; 19(1): e0296167, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38285672

RESUMEN

PURPOSE: To compared the vessel density (VD) around the optic nerve head (ONH) in eyes with cone-rod dystrophy (CORD) and healthy control eyes in a sector-wise manner and to investigate the relationship between VD around the ONH and visual function in CORD eyes. METHODS: Twenty-six eyes in 14 CORD patients and 25 eyes in 25 healthy control subjects were examined. Using OCT angiography images, the VDs in the superficial and deep capillary plexus at the macula (sVDm and dVDm) and those around the ONH in the superior, temporal, inferior and nasal region (VDnh_s, VDnh_t, VDnh_i, and VDnh_n, respectively) were measured for each eye. Patient age, visual acuity (VA) and VDs were then compared between two groups. Moreover, the relationships between VA and the VDs were analyzed using a linear mixed model and AICc model selection. RESULTS: No significant difference in age was seen between the CORD and control groups (p = 0.87, Wilcoxon rank sum test), but the VA was significantly lower in the CORD group (p<0.0001). Both sVDm and dVDm were significantly lower in the CORD eyes than in the control eyes (both p<0.0001). Among VDnh_s, VDnh_t, VDnh_i, and VDnh_n, however, only VDnh_t differed significantly between the CORD and control groups (p = 0.035). Among age, VDnh_t, dVDm, and sVDm, the optimal model for VA included only VDnh_t and dVDm. CONCLUSIONS: In addition to the VD in the deep capillary plexus at the macula, the measurement of temporal VD around the ONH might be useful for predicting visual function in eyes with CORD.


Asunto(s)
Distrofias de Conos y Bastones , Disco Óptico , Humanos , Angiografía con Fluoresceína/métodos , Vasos Retinianos/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Disco Óptico/diagnóstico por imagen , Disco Óptico/irrigación sanguínea
6.
Graefes Arch Clin Exp Ophthalmol ; 262(6): 1795-1803, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38285248

RESUMEN

PURPOSE: Recent evidence suggests that venous congestion at the vortex vein significantly contributes to the development of central serous chorioretinopathy (CSCR), and sclera is observed to be thicker in affected eyes. This study aims to investigate whether eyes with CSCR exhibit stiff corneas, measured using Corneal Visualization Scheimflug Technology (Corvis ST), which may serve as an indicator of scleral stiffness. METHODS: This retrospective case-control study comprises 52 eyes from 33 patients diagnosed with CSCR and 52 eyes from 32 normal controls without CSCR. We compared biomechanical parameters measured with Corvis ST and anterior scleral thickness measured using anterior segment swept-source optical coherence tomography between the two groups. RESULTS: Age, sex, axial length, intraocular pressure, and central corneal thickness showed no significant differences between the two groups (p > 0.05, linear mixed model). Three biomechanical parameters-peak distance, maximum deflection amplitude, and integrated inverse radius-indicated less deformability in CSCR eyes compared to control eyes. The stress-strain index (SSI), a measure of stiffness, and anterior scleral thickness (AST) at temporal and nasal points were significantly higher in the CSCR eyes. SSI and AST were not correlated, yet both were significantly and independently associated with CSCR in a multivariate logistic regression model. CONCLUSIONS: Eyes affected by CSCR have stiffer corneas, irrespective of thicker scleral thickness. This suggests that stiffer sclera may play a role in the pathogenesis of CSCR.


Asunto(s)
Coriorretinopatía Serosa Central , Córnea , Tomografía de Coherencia Óptica , Humanos , Coriorretinopatía Serosa Central/fisiopatología , Coriorretinopatía Serosa Central/diagnóstico , Masculino , Femenino , Estudios Retrospectivos , Tomografía de Coherencia Óptica/métodos , Persona de Mediana Edad , Fenómenos Biomecánicos , Córnea/fisiopatología , Córnea/diagnóstico por imagen , Esclerótica/fisiopatología , Adulto , Estudios de Casos y Controles , Elasticidad/fisiología , Presión Intraocular/fisiología , Agudeza Visual/fisiología
7.
Graefes Arch Clin Exp Ophthalmol ; 262(4): 1221-1229, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37921882

RESUMEN

PURPOSE: To clarify the abilities of circumpapillary retinal nerve fiber layer thickness (cpRNFLT) obtained by optical coherence tomography (OCT) and circumpapillary vessel density (cpVD) measured by OCT-angiography to distinguish different stages in primary open-angle glaucoma determined by 24-2 or 30-2 static visual field (VF) testing. METHODS: This retrospective study includes 25 healthy normal eyes of 25 subjects and 87 primary open-angle glaucoma eyes of 87 patients. Areas under the receiver operating characteristic curves (AUROC) were evaluated for determining glaucoma stages using cpRNFLT and cpVD. The absolute errors of the estimated mean total deviation (mTD) using optimal models with cpRNFLT and cpVD were also compared. RESULTS: The AUROCs for discriminating glaucomatous eyes from normal eyes was significantly higher for cpRNFLT than the respective AUROCs for cpVD (0.969 [95% CI 0.939 to 0.998] vs. 0.872 [95% CI 0.806 to 0.938], p = 0.006), whereas cpVD had significantly higher AUROC for discriminating severe glaucoma eyes from moderate glaucoma eyes than cpRNFLT (0.771 [95% CI 0.655 to 0.886] vs. 0.578 [95% CI 0.420 to 0.736], p = 0.022). The mean absolute error in estimating mTD using both cpRNFLT and cpVD was significantly less than the error using cpRNFLT alone (4.56 ± 3.76 dB vs. 5.39 ± 4.00 dB, p = 0.027). CONCLUSION: Our results suggest that cpVD is better for follow-ups after moderate stage. The combination of cpRNFLT and cpVD may improve VF estimation compared to cpRNFLT alone.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Disco Óptico , Humanos , Glaucoma de Ángulo Abierto/diagnóstico , Disco Óptico/irrigación sanguínea , Campos Visuales , Estudios Retrospectivos , Presión Intraocular , Densidad Microvascular , Vasos Retinianos , Células Ganglionares de la Retina , Tomografía de Coherencia Óptica/métodos , Fibras Nerviosas
8.
Sci Rep ; 13(1): 21777, 2023 12 08.
Artículo en Inglés | MEDLINE | ID: mdl-38066097

RESUMEN

The present study aimed to compare retinal sensitivity (RS) at each stage and to evaluate the relationship between RS and fundus autofluorescence (FAF) pattern in adult-onset foveomacular vitelliform dystrophy (AOFVD). We retrospectively reviewed 17 eyes of 13 patients with AOFVD. In addition to best-corrected visual acuity (VA), RS within the affected lesion and optical coherence tomography (OCT) measurements were carried out in each participant. All the examined eyes were classified into 4 stages and 3 FAF patterns. RS was superimposed on OCT fundus image and RS within the affected lesion was calculated in each eye. The relationships between visual functions (VA and RS within the affected lesion) and stages and also FAF patterns were analyzed using the linear mixed model. As a result, RS within the affected lesion was significantly associated with FAF pattern, but not with stage. In contrast, VA was correlated with neither stages nor FAF patterns. Our current result suggested that RS within the affected lesion was related to FAF patterns but this was not the case with VA in eyes with AOFVD, demonstrating the usefulness of measuring RS, not only VA, to comprehend the disease status in AOFVD.


Asunto(s)
Distrofia Macular Viteliforme , Adulto , Humanos , Distrofia Macular Viteliforme/diagnóstico por imagen , Estudios Retrospectivos , Agudeza Visual , Retina/diagnóstico por imagen , Fondo de Ojo , Tomografía de Coherencia Óptica/métodos , Angiografía con Fluoresceína/métodos
9.
Sci Rep ; 13(1): 22198, 2023 12 14.
Artículo en Inglés | MEDLINE | ID: mdl-38097656

RESUMEN

Our current study aimed to investigate the association of preoperative OCT parameters with visual function after vitrectomy surgery in eyes with epiretinal membrane (ERM). This study enrolled 33 eyes with ERM that underwent vitrectomy surgery. In addition to visual acuity (VA), metamorphopsia was measured pre- and postoperatively for each eye. Using the preoperative horizontal and vertical OCT images, SUKIMA (the gap area between the ERM and retinal surface) was measured respectively and the average of horizontal SUKIMA and vertical SUKIMA was used for the analysis. The associations of baseline parameters (age, axial length, preoperative central retinal thickness [CRT], inner nuclear layer [INL] thickness, ectopic inner foveal layer [EIFL] and SUKIMA) with postoperative VA, the change in VA, postoperative metamorphopsia and the improvement in metamorphopsia were investigated using multivariate regression analysis followed by the model selection. The result suggested that age and INL thickness were related to the postoperative VA, whereas age and preoperative CRT were significantly associated with the change in VA. In contrast, only SUKIMA was correlated with the postoperative metamorphopsia, whilst age, EIFL and SUKIMA were associated with the improvement in metamorphopsia. Measuring SUKIMA might be useful for predicting postoperative metamorphopsia and the improvement in metamorphopsia in ERM eyes.


Asunto(s)
Membrana Epirretinal , Humanos , Tomografía de Coherencia Óptica/métodos , Agudeza Visual , Trastornos de la Visión , Fóvea Central , Vitrectomía , Estudios Retrospectivos
10.
PLoS One ; 18(11): e0295123, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38033010

RESUMEN

PURPOSE: In a previous cross-sectional study, we reported that the sexes can be distinguished using known factors obtained from color fundus photography (CFP). However, it is not clear how sex differences in fundus parameters appear across the human lifespan. Therefore, we conducted a cohort study to investigate sex determination based on fundus parameters in elementary school students. METHODS: This prospective observational longitudinal study investigated 109 right eyes of elementary school students over 4 years (age, 8.5 to 11.5 years). From each CFP, the tessellation fundus index was calculated as red/red + green + blue (R/[R+G+B]) using the mean value of red-green-blue intensity in eight locations around the optic disc and macular region. Optic disc area, ovality ratio, papillomacular angle, and retinal vessel angles and distances were quantified according to the data in our previous report. Using 54 fundus parameters, sex was predicted by L2 regularized binomial logistic regression for each grade. RESULTS: The right eyes of 53 boys and 56 girls were analyzed. The discrimination accuracy rate significantly increased with age: 56.3% at 8.5 years, 46.1% at 9.5 years, 65.5% at 10.5 years and 73.1% at 11.5 years. CONCLUSIONS: The accuracy of sex discrimination by fundus photography improved during a 3-year cohort study of elementary school students.


Asunto(s)
Juicio , Estudiantes , Niño , Femenino , Humanos , Masculino , Estudios de Cohortes , Fondo de Ojo , Estudios Longitudinales , Fotograbar , Tomografía de Coherencia Óptica
11.
Sci Rep ; 13(1): 19148, 2023 11 06.
Artículo en Inglés | MEDLINE | ID: mdl-37932377

RESUMEN

Minimally invasive glaucoma surgery has expanded the surgical treatment options in glaucoma, particularly when combined with cataract surgery. It is clinically relevant to understand the associated postoperative changes in biomechanical properties because they are influential on the measurement of intraocular pressure (IOP) and play an important role in the pathogenesis of open-angle glaucoma (OAG). This retrospective case-control study included OAG patients who underwent cataract surgery combined with microhook ab interno trabeculotomy (µLOT group: 53 eyes of 36 patients) or iStent implantation (iStent group: 59 eyes of 37 patients) and 62 eyes of 42 solo cataract patients without glaucoma as a control group. Changes in ten biomechanical parameters measured with the Ocular Response Analyzer and Corneal Visualization Scheimpflug Technology (Corvis ST) at 3 and 6 months postoperatively relative to baseline were compared among the 3 groups. In all the groups, IOP significantly decreased postoperatively. In the µLOT and control groups, significant changes in Corvis ST-related parameters, including stiffness parameter A1 and stress‒strain index, indicated that the cornea became softer postoperatively. In contrast, these parameters were unchanged in the iStent group. Apart from IOP reduction, the results show variations in corneal biomechanical changes from minimally invasive glaucoma surgery combined with cataract surgery.


Asunto(s)
Catarata , Glaucoma de Ángulo Abierto , Glaucoma , Trabeculectomía , Humanos , Glaucoma de Ángulo Abierto/cirugía , Estudios Retrospectivos , Estudios de Casos y Controles , Fenómenos Biomecánicos , Trabeculectomía/métodos , Glaucoma/cirugía , Presión Intraocular , Córnea
12.
Cureus ; 15(10): e46500, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37927688

RESUMEN

PURPOSE: In binocular vision, there is a dominant eye and a nondominant eye, a phenomenon termed ocular dominance. This study determined the differences and associations of the ocular blood flow parameters between dominant and nondominant eyes in healthy Japanese subjects. METHODS: This cross-sectional study included 128 eyes of 64 subjects (13 male and 51 female) aged ≥ 20 years. The ocular blood flow parameters were assessed using laser speckle flowgraphy (LSFG), and software was used to calculate the mean blur rate (MBR), which reflects the blood flow velocity. RESULTS: There were no significant differences in axial length (AL), spherical equivalent (SE), intraocular pressure (IOP), uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), or ocular blood flow parameters between the dominant and nondominant eyes. The ocular blood flow parameters of the dominant eye were significantly and positively correlated with those of the nondominant eye (all P < 0.001). CONCLUSIONS: No significant differences in ocular blood flow parameters exist between the dominant and nondominant eyes in healthy subjects. The ocular blood flow parameters in the dominant eye are associated with those in the nondominant eye.

13.
Clin Ophthalmol ; 17: 2525-2537, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37662650

RESUMEN

Purpose: To compare the efficacy of Ex-PRESS implantation (EXP) with that of trabeculectomy (TLE) with mitomycin C for maintaining low target intraocular pressure (IOP) in patients with open-angle glaucoma. Patients and Methods: Patients were randomly assigned to receive EXP or TLE. Surgical success was defined according to three target mean IOP ranges (5 mmHg ≤ IOP ≤ 18 mmHg [criterion A], 5 mmHg ≤ IOP ≤ 15 mmHg [criterion B], and 5 mmHg ≤ IOP ≤ 12 mmHg [criterion C]) representing reductions of at least 20% below the baseline on two consecutive follow-up visits 3 months post-surgery, with or without antiglaucoma medication and without further glaucoma surgery. Participants were divided into three subgroups based on baseline mean deviation (MD) values: early (MD ≥ -6 dB), moderate (-6 dB > MD ≥ -12 dB), and advanced (-12 dB > MD). Survival rates were calculated by subgroup. Results: A total of 73 patients, including 30 in the EXP group and 43 in the TLE group, were included in the study. No significant differences in baseline ocular or demographic characteristics were found between the two groups. No significant difference in IOP was noted every 6 months. After the 3-year follow-up, success rates were A) 60.0% and 60.2%, B) 45.7% and 58.1%, and C) 31.5% and 40.5% for the EXP and TLE groups, respectively. Moreover, there was no difference in success rate based on glaucoma level. Many glaucoma medications administered before surgery were associated with a higher failure rate in the TLE group but not in the EXP group. Conclusion: Both procedures resulted in similar IOP reductions and success rates for a low target IOP. The number of preoperative glaucoma medications was a risk factor for TLE failure.

14.
PLoS One ; 18(9): e0291208, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37682905

RESUMEN

PURPOSE: To investigate the clinical validity of the Guided Progression Analysis definition (GPAD) and cluster-based definition (CBD) with the Humphrey Field Analyzer (HFA) 10-2 test in retinitis pigmentosa (RP). METHODS: Ten non-progressive RP visual fields (VFs) (HFA 10-2 test) were simulated for each of 10 VFs of 111 eyes (10 simulations × 10 VF sequencies × 111 eyes = 111,000 VFs; Dataset 1). Using these simulated VFs, the specificity of GPAD for the detection of progression was determined. Using this dataset, similar analyses were conducted for the CBD, in which the HFA 10-2 test was divided into four quadrants. Subsequently, the Hybrid Definition was designed by combining the GPAD and CBD; various conditions of the GPAD and CBD were altered to approach a specificity of 95.0%. Subsequently, actual HFA 10-2 tests of 116 RP eyes (10 VFs each) were collected (Dataset 2), and true positive rate, true negative rate, false positive rate, and the time required to detect VF progression were evaluated and compared across the GPAD, CBD, and Hybrid Definition. RESULTS: Specificity values were 95.4% and 98.5% for GPAD and CBD, respectively. There were no significant differences in true positive rate, true negative rate, and false positive rate between the GPAD, CBD, and Hybrid Definition. The GPAD and Hybrid Definition detected progression significantly earlier than the CBD (at 4.5, 5.0, and 4.5 years, respectively). CONCLUSIONS: The GPAD and the optimized Hybrid Definition exhibited similar ability for the detection of progression, with the specificity reaching 95.4%.


Asunto(s)
Retinitis Pigmentosa , Campos Visuales , Humanos , Retinitis Pigmentosa/diagnóstico , Ojo
15.
Transl Vis Sci Technol ; 12(8): 19, 2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-37615642

RESUMEN

Purpose: The purpose of this study was to investigate risk factors for progression in the superior and inferior hemi-visual fields (hemi-VFs) and the corresponding hemi-disc/retinas in eyes with normal tension glaucoma (NTG). Methods: A 5-year prospective follow-up of 90 patients with NTG with untreated intraocular pressure (IOP) consistently ≤ 15 mm Hg was conducted. The IOP and Humphrey Perimeter measurements and disc/retina stereo-photographs were taken every 3 and 6 months, respectively. Risk factors for progression in the superior and inferior hemi-VFs and in the superior and inferior hemi-disc/retinas were investigated. Results: The mean total deviation values decreased at -0.50 ± 0.76 and -0.13 ± 0.34 dB/year in the superior and inferior hemi-VFs, respectively (P < 0.001). In the superior hemi-VF, the risk factor for faster progression was greater long-term IOP fluctuation (P = 0.022). In the inferior hemi-VF, the risk factors were disc hemorrhage (DH), greater myopic refraction, body mass index (BMI), and vertical cup-to-disc ratio (v-C/D; P < 0.05). The progression probability was 47.7 ± 6.0 and 17.7 ± 4.7% at 5 years in the superior and inferior hemi-disc/retinas respectively (P < 0.001), and DH was a risk factor for progression in both (P = 0.001). Conclusions: In NTG eyes, greater BMI, myopia, and v-C/D are characteristic risk factors for faster progression in the superior half of the optic nerve head (ONH), whereas long-term IOP fluctuation is the significant risk factor in the inferior half of the ONH, whereas DH is a risk factor in both. Translational Relevance: Different risk factors were identified in superior and inferior hemifields in NTG eyes.


Asunto(s)
Glaucoma , Glaucoma de Baja Tensión , Miopía , Disco Óptico , Humanos , Disco Óptico/diagnóstico por imagen , Presión Intraocular , Estudios Prospectivos , Glaucoma/diagnóstico
16.
Jpn J Ophthalmol ; 67(5): 546-559, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37540325

RESUMEN

Timely treatment is essential in the management of glaucoma. However, subjective assessment of visual field (VF) progression is not recommended, because it can be unreliable. There are two types of artificial intelligence (AI) strong and weak (machine learning). Weak AIs can perform specific tasks. Linear regression is a method of weak AI. Using linear regression in the real-world clinic has enabled analyzing and predicting VF progression. However, caution is still required when interpreting the results, because whenever the number of VF data sets investigated is small, the predictions can be inaccurate. Several other non-ordinal, or modern AI methods have been constructed to improve prediction accuracy, such as clustering and more modern AI methods of Analysis with Non-Stationary Weibull Error Regression and Spatial Enhancement (ANSWERS), Variational Bayes Linear Regression (VBLR), Kalman Filter and sparse modeling (The least absolute shrinkage and selection operator regression: Lasso). It is also possible to improve the prediction performance using retinal thickness measured with optical coherence tomography by using machine learning methods, such as multitask learning.


Asunto(s)
Glaucoma , Campos Visuales , Humanos , Inteligencia Artificial , Teorema de Bayes , Pruebas del Campo Visual/métodos , Glaucoma/diagnóstico , Progresión de la Enfermedad , Tomografía de Coherencia Óptica , Presión Intraocular
17.
J Clin Med ; 12(15)2023 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-37568510

RESUMEN

BACKGROUND: We compared corneal visualization Scheimpflug technology (CST) parameters between eyes with primary open-angle glaucoma (POAG) and primary angle-closure glaucoma (PACG). METHODS: A retrospective analysis was performed on data from 89 eyes with POAG and 83 eyes with PACG that had CST examinations. CST parameters were compared between eyes with POAG and those with PACG using a linear mixed model (LMM). RESULTS: No differences were observed in age, central corneal thickness, intraocular pressure, or use of antiglaucoma eye drops between the two groups. Patients with PACG had a significantly shorter axial length (AL), a higher proportion of females, CST parameters, longer applanation 2 (A2) time, deeper A2 deformation amplitude, shorter peak distance, longer whole eye movement, and longer whole eye movement time than patients with POAG. The highest concavity (HC) length and PD showed a significant positive correlation with AL. However, A1 length, A1 deformation amplitude, A2 time, A2 velocity, A2 length, A2 deformation amplitude, HC time, whole eye movement, and whole eye movement time were negatively correlated with AL. CONCLUSIONS: The biomechanical properties of the cornea differed between POAG and PACG. In some parts, AL differences between the POAG and PACG groups might contribute to the variation in CST parameters.

18.
Ophthalmol Ther ; 12(5): 2757-2768, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37548906

RESUMEN

INTRODUCTION: The purpose of this study was to compare the surgical outcomes between ab interno trabeculotomy (LOT) and iStent inject W implantation (iStent) both combined with cataract surgery, matching the background factors including age, intraocular pressure (IOP), medication score, central corneal thickness (CCT), and axial length. METHODS: A total of 100 eyes from 75/79 patients with primary open-angle glaucoma were included in the LOT/iStent groups. The background factors were matched between the two groups using the propensity score. RESULTS: There were no significant differences in age, IOP, medication score, CCT, and axial length, preoperatively. The postoperative medication scores were 1.3 ± 1.2 and 1.2 ± 1.2 in the LOT and iStent groups. The postoperative IOPs were 12.8 ± 2.8 and 13.1 ± 2.4 mmHg in the LOT and iStent groups, respectively. The changes in the medication score were - 0.64 ± 1.4 and - 0.44 ± 1.6 in the LOT and iStent groups, respectively. The changes in the IOP were - 2.1 ± 3.3 and - 1.5 ± 3.0 mmHg in the LOT and iStent groups, respectively. These values were not significantly different between the two groups. The postoperative IOP and changes in the IOP were significantly associated with preoperative IOP and CCT. There was no significant difference in the occurrence of postoperative complications (hyphema, 11.0% and 6.0%, and transient ocular hypertension, 8.0% and 5.0%, in the LOT and iStent groups, respectively). CONCLUSION: LOT and iStent have similar surgical outcomes with sufficient safety. Postoperative IOP was significantly associated with preoperative IOP and CCT in both groups.

19.
Retina ; 43(10): 1745-1749, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37315568

RESUMEN

PURPOSE: This study aims to investigate the postoperative refractive outcomes in eyes that underwent the flanged intrascleral intraocular lens (IOL) fixation combined with vitrectomy with or without gas/air tamponade. METHODS: The eyes were divided into two groups (Group A; eyes that underwent flanged intrascleral IOL fixation with gas/air tamponade, and Group B; eyes that underwent flanged intrascleral IOL fixation without gas/air tamponade). The predicted spherical equivalent (SE) refraction values were calculated using the Sander-Retzlaff-Kraff Theoretical formula. Then, the prediction error was calculated by subtracting the predicted SE refraction from the postoperative objective SE refraction and the absolute prediction error was calculated as the absolute value of the prediction error for each eye. RESULTS: A total of 68 eyes were included in the current study. There was a significant correlation between the predicted and postoperative SE refraction in both groups (Group A, r = 0.968, P < 0.0001, Group B, r = 0.943, P < 0.0001, linear regression analysis). The prediction error demonstrated a mild myopic shift after the flanged intrascleral IOL fixation in both groups (Group A, -0.40 ± 0.96 diopter, Group B, -0.59 ± 0.95 diopter). There was no significant difference in prediction error and absolute prediction error between the two groups ( P = 0.44, P = 0.70, Wilcoxon rank sum test). CONCLUSION: The postoperative SE refraction after flanged intrascleral IOL fixation was not influenced by gas/air tamponade.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares , Humanos , Agudeza Visual , Refracción Ocular , Esclerótica/cirugía , Estudios Retrospectivos
20.
J Biophotonics ; 16(8): e202300071, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37072378

RESUMEN

The Veggie Meter® (VM) is a refraction spectrometer that detects skin carotenoids. We tested the variability of the two modes (single-scan and averaging modes) of four VMs of three different versions (VM-1, 2, 3, 4) with 92 healthy volunteers. Both the modes exhibited a high intra-class correlation coefficient (ICC); however, the averaging mode had a significantly lower coefficient of variance than the single-scan mode. The Bland-Altman analysis showed a systematic error between VM-1 and other three VMs. The actual errors between the VM-1 and the other three VMs in the averaging mode were 7.4%, 10.4%, and 11.8% of the median of VM scores, but the errors could be reduced to 2.8%, 6.3%, and 7.0% by compensating VM scores using the regression equations. Averaging mode had higher accuracy than single-scan mode. The reliability of the VMs was validated by the small coefficient of variation and high ICC. The error was improved using linear regression compensation.


Asunto(s)
Reproducibilidad de los Resultados , Humanos , Análisis Espectral
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA