Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Am J Gastroenterol ; 118(10): 1768-1778, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37646335

RESUMEN

Interventional endoscopic ultrasound has fueled remarkable advancements in the field of therapeutic procedures, revolutionizing minimally invasive interventions for a diverse range of conditions. This review highlights the latest breakthroughs and advancements in therapeutic endoscopic ultrasound, showcasing its potential to transform patient care.


Asunto(s)
Endoscopía , Endosonografía , Humanos , Predicción , Ultrasonografía Intervencional
2.
Curr Opin Gastroenterol ; 39(5): 356-361, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37389433

RESUMEN

PURPOSE OF REVIEW: Gastric outlet obstruction (GOO) occurs from benign or malignant causes. Historically, the treatment of benign strictures revolved around endoscopic balloon dilation, whereas, in the case of malignant strictures, the placement of self-expandable metallic stents was the focus. The advent of lumen-apposing metal stent has opened new horizons in addressing shortcomings of enteral stenting and surgical gastroenterostomies. The purpose of the review is to discuss the endoscopic approaches to small bowel strictures and to examine the supporting data behind each practice. RECENT FINDINGS: Given the risk and futility of balloon dilation for malignant strictures, enteral stenting is pursued in patients who are poor surgical candidates and with life expectancy less than 6 months. For patients with longer survival, surgical gastroenterostomy (S-GE) should be considered. Recent data have shown comparable technical and clinical success rates between EUS-gastroenterostomy and S-GE but with lower adverse event rate and hospital length of stay. SUMMARY: In recurrent benign strictures and malignant GOO, EUS-GE has recently gained momentum in providing an effective and a well tolerated alternative. Individualized therapy centered around the patient's prognosis and preference while factoring in the local expertise for the specific indication is vital.


Asunto(s)
Endoscopía , Obstrucción de la Salida Gástrica , Humanos , Constricción Patológica/cirugía , Gastroenterostomía , Obstrucción de la Salida Gástrica/cirugía , Stents/efectos adversos , Estudios Retrospectivos
3.
Gastrointest Endosc ; 97(6): 1059-1066.e3, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36738796

RESUMEN

BACKGROUND AND AIMS: Post-ERCP pancreatitis (PEP) is the most frequent adverse event of ERCP. Various prophylactic measures are endorsed by the American Society for Gastrointestinal Endoscopy and the European Society of Gastrointestinal Endoscopy to both lower the incidence of PEP and to decrease its severity. The extent to which these interventions are practiced throughout the United States is unclear. The aim of this study was to describe the utilization pattern of various PEP measures and determine factors that affect utilization of these measures. METHODS: A 27-question electronic survey was distributed using a cloud-based program (Qualtrics). The questions assessed ERCP training, practice setting, experience, practice patterns, and perceptions for PEP prophylaxis interventions. Endoscopists with practices based in the United States listed in the American Society for Gastrointestinal Endoscopy member directory received a survey invitation via e-mail. The invitation outlined the study and contained a link with instructions to complete the voluntary survey if they had an active ERCP practice. Data were de-identified for the purposes of analysis. RESULTS: Of survey respondents (N = 319), 46% reported therapeutic endoscopy fellowship training and 37% practiced in teaching programs. Annualized ERCP volume of >100 cases per year were reported by 47%, with pancreatic ERCP comprising ≤5% of procedure volume reported by the majority of respondents (61%). The majority of respondents used prophylactic pancreatic stent (PPS), and 54% reported frequent use during high-risk ERCP. The most common indications for PPS were difficult cannulation, to assist biliary access, and multiple pancreatic duct injections. Most respondents reported frequent use of indomethacin (89%). Of physicians who did not use PPS, use of indomethacin was the most common reason (80%). Variables associated with frequent use of PPS were ERCP fellowship training (P ≤ .001), practice at a teaching program (P ≤ .001), <10 years in practice (P = .005), higher procedure volume (P ≤ .001), and higher proportion of pancreatic cases (P ≤ .001). CONCLUSIONS: Physicians with higher annual ERCP volume, who teach at hospital-based ERCP practices, and who regularly perform pancreatic ERCP are more likely to use PPS. Therapeutic ERCP fellowship training and recent entry into practice were also associated with PPS utilization. Indomethacin use seems to be more frequent than PPS. Our findings suggest that indomethacin is supplanting PPS as the preferred method of PEP prophylaxis.


Asunto(s)
Colangiopancreatografia Retrógrada Endoscópica , Pancreatitis , Humanos , Colangiopancreatografia Retrógrada Endoscópica/efectos adversos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Pancreatitis/etiología , Pancreatitis/prevención & control , Pancreatitis/epidemiología , Conductos Pancreáticos , Cateterismo , Indometacina/uso terapéutico , Stents/efectos adversos , Factores de Riesgo
4.
ACG Case Rep J ; 10(1): e00963, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36699184

RESUMEN

Erdheim-Chester disease (ECD) is an exceedingly rare and aggressive disease characterized by foamy CD68 + CDa-histiocytic infiltration into multiple tissues and organs. Only 1,500 cases have been diagnosed since 1930 when ECD was first described. Biliary tract involvement of ECD has only been reported in the literature once. We report a case of ECD causing extrahepatic biliary obstruction without significant bile duct dilation, mimicking primary sclerosing cholangitis or IgG4 disease.

5.
J Clin Gastroenterol ; 57(2): 211-217, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-34009843

RESUMEN

BACKGROUND: Endoscopic ultrasound-guided rendezvous (EUS-RV) endoscopic retrograde cholangiopancreatography (ERCP) is an alternative to interventional radiology-guided rendezvous ERCP in patients who failed biliary cannulation with conventional ERCP. However, there is significant variation in reported rates of success and adverse events associated with EUS-RV-assisted ERCP. We performed a systematic review and a proportion meta-analysis to reliably assess the effectiveness and safety of the EUS-RV-assisted ERCP. MATERIALS AND METHODS: We conducted a comprehensive search of multiple electronic databases and conference proceedings (from inception through August 2020) to identify studies reporting EUS-RV-assisted ERCP in patients who failed biliary cannulation with conventional ERCP techniques. Using the random-effects model described by DerSimonian and Laird, we calculated the pooled rates of technical success, clinical success, and adverse events of EUS-RV-assisted ERCP. RESULTS: Twelve studies reporting a total of 342 patients were included in the meta-analysis. The pooled rate of technical success (12 studies reporting a total of 342 patients) was 86.1% [95% confidence interval (CI): 78.4-91.3]. The pooled rate of clinical success (4 studies reporting a total of 94 patients) was 80.8% (95% CI: 64.1-90.8). The pooled rate of overall adverse events (12 studies; 42 events in 342 patients) was 14% (95% CI: 10.5-18.4). Low to moderate heterogeneity was noted in the analyses. CONCLUSIONS: EUS-RV-assisted ERCP appears to be effective and safe in patients who failed biliary cannulation with conventional ERCP. Given the risk of adverse events, it should be performed in centers with expertise in therapeutic endoscopic ultrasound.


Asunto(s)
Cateterismo , Colangiopancreatografia Retrógrada Endoscópica , Humanos , Colangiopancreatografia Retrógrada Endoscópica/efectos adversos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Cateterismo/efectos adversos , Cateterismo/métodos , Endosonografía/efectos adversos , Endosonografía/métodos , Drenaje/métodos , Bases de Datos Factuales
6.
VideoGIE ; 7(12): 462-465, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36467535

RESUMEN

Background and Aims: Dysphagia is a common complaint for patients after radiation therapy for head and neck cancer. Chronic dysphagia ensues when the radiation-induced injury matures into a fibrotic stricture, with the severity of symptoms paralleling the degree of stenosis. Most patients experience progressive dysphagia that prompts medical attention before complete esophageal obliteration. Rarely, patients present late with inability to clear their secretions because of complete obstruction, also termed acquired atresia. These patients represent a challenge and require aggressive and unconventional interventions to reestablish lumenal patency. Using a case series, we hereby describe a novel yet simple technique to treat patients with acquired esophageal atresia. Methods: Five patients with head and neck cancer in various stages who all underwent nonsurgical treatment with definitive chemotherapy and radiation along with enteral feeding tube placement prior to/during treatment presented with acquired esophageal atresia. All patients underwent an EGD to reestablish lumenal patency. This was accomplished with gentle pressure that was applied in a to-and-fro semi-circular rotational manner as if pushing a corkscrew and twisting it in alternating clockwise and counterclockwise manner. Results: In all cases we were able to reestablish esophageal lumenal patency with a single procedure. There were no adverse events. Four of the 5 patients required additional dilations for symptomatic management. However, all patients' esophageal lumens remained patent. Conclusions: We describe a novel yet simple technique to treat acquired esophageal atresia after radiation for head and neck cancer. This technique allows for generous dilation yielding complete resolution of the stenosis in a single session. When our approach is used, the patient can be discharged home the same day and resume immediate oral intake.

9.
Clin Endosc ; 55(1): 33-40, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34974676

RESUMEN

BACKGROUND/AIMS: Multiple outbreaks of multidrug-resistant organisms have been reported worldwide due to contaminated duodenoscopes. In 2015, the United States Food and Drug Administration recommended the following supplemental enhanced surveillance and reprocessing techniques (ESRT) to improve duodenoscope disinfection: (1) microbiological culture, (2) ethylene oxide sterilization, (3) liquid chemical sterilant processing system, and (4) double high-level disinfection. A systematic review and meta-analysis was performed to assess the impact of ESRT on the contamination rates. METHODS: A thorough and systematic search was performed across several databases and conference proceedings from inception until January 2021, and all studies reporting the effectiveness of various ESRTs were identified. The pooled contamination rates of post-ESRT duodenoscopes were estimated using the random effects model. RESULTS: A total of seven studies using various ESRTs were incorporated in the analysis, which included a total of 9,084 post-ESRT duodenoscope cultures. The pooled contamination rate of the post-ESRT duodenoscope was 5% (95% confidence interval [CI]: 2.3%-10.8%, inconsistency index [I2]=97.97%). Pooled contamination rates for high-risk organisms were 0.8% (95% CI: 0.2%-2.7%, I2=94.96). CONCLUSION: While ESRT may improve the disinfection process, a post-ESRT contamination rate of 5% is not negligible. Ongoing efforts to mitigate the rate of contamination by improving disinfection techniques and innovations in duodenoscope design to improve safety are warranted.

10.
Gastrointest Endosc ; 94(3): 441-451, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34147512

RESUMEN

The American Society for Gastrointestinal Endoscopy's Gastrointestinal Endoscopy Editorial Board reviewed a systematic literature search of original endoscopy-related articles published during 2020 in Gastrointestinal Endoscopy and 10 other high-impact medical and gastroenterology journals. Votes from each individual board member were tallied to identify a consensus list of the 10 most significant topic areas in GI endoscopy over the calendar year of study using 4 criteria: significance, novelty, impact on national health, and impact on global health. The 10 areas identified were as follows: artificial intelligence in endoscopy, coronavirus disease 2019 and GI practice, third-space endoscopy, lumen-apposing metal stents, single-use duodenoscopes and other disposable equipment, endosonographic needle technology and techniques, endoscopic closure devices, advances in GI bleeding management, improvements in polypectomy techniques, and bariatric endoscopy. Each board member contributed a summary of important articles relevant to 1 to 2 topic areas, leading to a collective summary that is presented in this document of the "top 10" endoscopic advances of 2020.


Asunto(s)
COVID-19 , Gastroenterología , Inteligencia Artificial , Endoscopía , Endoscopía Gastrointestinal , Humanos , SARS-CoV-2
11.
Endosc Int Open ; 9(4): E513-E521, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33816771

RESUMEN

Background and study aims With the advent of deep neural networks (DNN) learning, the field of artificial intelligence (AI) is rapidly evolving. Recent randomized controlled trials (RCT) have investigated the influence of integrating AI in colonoscopy and its impact on adenoma detection rates (ADRs) and polyp detection rates (PDRs). We performed a systematic review and meta-analysis to reliably assess if the impact is statistically significant enough to warrant the adoption of AI -assisted colonoscopy (AIAC) in clinical practice. Methods We conducted a comprehensive search of multiple electronic databases and conference proceedings to identify RCTs that compared outcomes between AIAC and conventional colonoscopy (CC). The primary outcome was ADR. The secondary outcomes were PDR and total withdrawal time (WT). Results Six RCTs (comparing AIAC vs CC) with 5058 individuals undergoing average-risk screening colonoscopy were included in the meta-analysis. ADR was significantly higher with AIAC compared to CC (33.7 % versus 22.9 %; odds ratio (OR) 1.76, 95 % confidence interval (CI) 1.55-2.00; I 2  = 28 %). Similarly, PDR was significantly higher with AIAC (45.6 % versus 30.6 %; OR 1.90, 95 %CI, 1.68-2.15, I 2  = 0 %). The overall WT was higher for AIAC compared to CC (mean difference [MD] 0.46 (0.00-0.92) minutes, I 2  = 94 %). Conclusions There is an increase in adenoma and polyp detection with the utilization of AIAC.

12.
Gastrointest Endosc ; 93(1): 140-150.e2, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32526235

RESUMEN

BACKGROUND AND AIMS: EUS-guided FNA primarily provides cytologic samples. EUS-guided fine-needle biopsy (FNB) with needles that provide histologic specimens may enhance diagnostic yield and facilitate accessory tissue staining. Several different needle designs are currently available and design superiority is unknown. We designed a randomized controlled trial to compare 2 commonly used EUS-FNB needles in their ability to provide histologic tissue samples (primary endpoint) and to reach an accurate diagnosis (secondary endpoint). METHODS: A total of 150 lesions from 134 patients (November 2018 to June 2019) were randomized 1:1 between biopsy with a Franseen needle and a Fork-tip needle. The groups were compared regarding the quality of the tissue samples and diagnostic accuracy. RESULTS: Of 150 lesions, 75 were pancreatic and 75 were other solid lesions in and around the GI tract. There was no statistically significant difference between the Franseen needle and the Fork-tip needle in the yield of adequate histologic samples, 71 of 75 (94.7%) versus 72 of 75 (96%), (P = 1.00), an absolute difference of -1.3% (95% confidence interval [CI], -8.1% to 5.4%). The 2 groups were similar in the diagnostic accuracy of histologic analysis, 64 of 75 (85.3%) versus 68 of 75 (90.7%) (P = .45), absolute difference -5.4% (95% CI, -15.7% to 5%); and in the diagnostic accuracy of combined cytologic and histologic analysis, 65 of 75 (86.7%) versus 69 of 75 (92%) (P = .43), absolute difference -5.3% (95% CI, -15.2% to 4.5%). CONCLUSIONS: There was no significant difference in the performance of the Franseen needle versus the Fork-tip needle. Both needles achieved a high yield of histologic tissue samples and high diagnostic accuracy. (Clinical trial registration number: NCT03672032.).


Asunto(s)
Agujas , Neoplasias Pancreáticas , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico , Diseño de Equipo , Humanos , Páncreas/diagnóstico por imagen
13.
Indian J Gastroenterol ; 39(4): 370-376, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32705418

RESUMEN

BACKGROUND: Narrow band imaging (NBI) with magnification better visualizes the duodenal microsurface and mucosal vascularity. NBI delineates villous atrophy better than conventional white light endoscopy. AIMS: This study was conducted to evaluate the diagnostic accuracy of narrow band imaging with magnification (NBI-ME) in celiac disease (CD). METHODS: In this prospective study, consecutive patients of suspected CD and controls were subjected to tissue transglutaminase antibody test and endoscopic evaluation initially with white light followed by NBI-ME, and biopsies were taken from duodenum. Duodenal villous patterns on NBI were interpreted as normal, blunted distorted, and absent. Severity of villous atrophy was reported according to the modified Marsh criteria. RESULTS: One hundred and twenty-two patients (mean age of 27.53 ± 13.37 years and a male to female ratio of 1:1.26) and 40 controls were studied. The sensitivity and specificity of NBI-ME in predicting villous atrophy were found to be 95.54% and 90%, respectively. The specificity and negative predictive value of NBI-ME in predicting villous atrophy amongst controls was 100% and 97.5%, respectively. Abnormal findings (blunted and absent villous patterns) combined with elevated transglutaminase antibody (> 5-fold) were found to have high accuracy in predicting villous atrophy. CONCLUSION: NBI with magnification has high sensitivity and specificity in predicting villous atrophy in patients with celiac disease.


Asunto(s)
Enfermedad Celíaca/diagnóstico por imagen , Enfermedad Celíaca/patología , Imagen de Banda Estrecha/métodos , Adolescente , Adulto , Atrofia , Duodeno/irrigación sanguínea , Duodeno/diagnóstico por imagen , Duodeno/patología , Femenino , Humanos , Mucosa Intestinal/irrigación sanguínea , Mucosa Intestinal/diagnóstico por imagen , Mucosa Intestinal/patología , Masculino , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Adulto Joven
14.
Clin Endosc ; 53(4): 471-479, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32019294

RESUMEN

BACKGROUND/AIMS: Endoscopic ultrasound (EUS)-guided fine-needle aspiration is very effective for providing specimens for cytological evaluation. However, the ability to provide sufficient tissue for histological evaluation has been challenging due to the technical limitations of dedicated core biopsy needles. Recently, a modified EUS needle has been introduced to obtain tissue core samples for histological analysis. We aimed to determine (1) its ability to obtain specimens for histological assessment and (2) the diagnostic accuracy of EUS-guided fine-needle biopsy (EUS-FNB) using this needle. METHODS: We retrospectively analyzed consecutive cases of FNB using modified EUS needles for 342 lesions in 303 patients. The cytology and histological specimens were analyzed. Diagnostic accuracy was calculated. RESULTS: Adequate cytological and histological assessment was possible in 293/342 (86%) and 264/342 (77%) lesions, respectively. Diagnostic accuracy of the cytological specimen was 294/342 (86%) versus 254/342 (74%) for the histological specimen (p<0.01). Diagnostic accuracy of the combined cytological and histological assessment was 323/342 (94.4%), which was significantly higher than that of both histology alone (p<0.001) and cytology alone (p=0.001). CONCLUSION: EUS-FNB with the modified EUS needle provided histologic tissue cores in the majority of cases and achieved excellent diagnostic accuracy with few needle passes.

15.
Endoscopy ; 52(1): 61-67, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31739370

RESUMEN

BACKGROUND: Interval colorectal cancers may be associated with a low serrated polyp detection rate (SDR) and advanced adenoma detection rate (AADR). We aimed to determine the SDR and AADR for endoscopists in a United States multicenter cohort. METHODS: We included average-risk screening colonoscopies from five medical centers in the United States. Endoscopists with data on at least 100 average-risk screening colonoscopies were included. We calculated median SDR and AADR for endoscopists with adequate adenoma detection rates (ADRs) > 25 %. We analyzed the relationship between ADR and SDR, and between ADR and AADR using nonparametric Spearman correlation coefficients, scatter plots, and linear regression. RESULTS: We included 3513 screening colonoscopies performed by 26 gastroenterologists. The mean age of patients was 56.8 years (SD 7.4) and 1585 (45 %) were male. All but one endoscopist had an ADR above 25 %. There was a significant positive but modest correlation between ADR and SDR (rho = 0.67, P < 0.01), and between ADR and AADR (rho = 0.56, P < 0.01). For endoscopists with an adequate ADR, median (interquartile range) ADR was 43 % (32.0 % - 48.6 %), median SDR was 8.4 % (7.3 % - 11.4 %), and median AADR was 9.3 % (6.4 % - 12.6 %). CONCLUSION: A significant percentage of endoscopists have either a low SDR or low AADR despite an adequate ADR, justifying the need for separate SDR and AADR benchmarks. Based on our multicenter cohort, endoscopists with adequate ADRs had a median SDR and median AADR of about 8 % and 9 %, respectively.


Asunto(s)
Adenoma , Neoplasias Colorrectales , Pólipos , Adenoma/diagnóstico por imagen , Colonoscopía , Neoplasias Colorrectales/diagnóstico por imagen , Detección Precoz del Cáncer , Femenino , Humanos , Masculino , Tamizaje Masivo , Persona de Mediana Edad
16.
ACG Case Rep J ; 6(7): e00100, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31620511

RESUMEN

Caustic esophageal strictures are complex strictures with high rates of recurrence and complications. Management of these strictures requires a multipronged approach including endoscopic dilation and complex surgeries. Even with these modalities, treatment of each patient has to be individualized because it requires high clinical discretion. We present a 38-year-old female woman who had required esophagostomy and total gastrectomy in the acute phase after caustic ingestion. The definitive surgical procedure was deferred because of cicatrization of the proximal esophageal remnant. We remodeled scarred esophagus using a novel technique, which facilitated definitive surgery.

17.
World J Gastroenterol ; 25(34): 5210-5219, 2019 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-31558868

RESUMEN

BACKGROUND: Bilateral vs unilateral biliary stenting is used for palliation in malignant biliary obstruction. No clear data is available to compare the efficacy and safety of bilateral biliary stenting over unilateral stenting. AIM: To assess the efficacy and safety of bilateral vs unilateral biliary drainage in inoperable malignant hilar obstruction. METHODS: PubMed, Embase, Scopus, and Cochrane databases, as well as secondary sources (bibliographic review of selected articles and major GI proceedings), were searched through January 2019. The primary outcome was the re-intervention rate. Secondary outcomes were a technical success, early and late complications, and stent malfunction rate. Pooled odds ratio (OR) and 95% confidence interval (CI) were calculated for each outcome. RESULTS: A total of 9 studies were included (2 prospective Randomized Controlled Study, 5 retrospective studies, and 2 abstracts), involving 782 patients with malignant hilar obstruction. Bilateral stenting had significantly lower re-intervention rate compared with unilateral drainage (OR = 0.59, 95%CI: 0.40-0.87, P = 0.009). There was no difference in the technical success rate (OR = 0.7, CI: 0.42-1.17, P = 0.17), early complication rate (OR = 1.56, CI: 0.31-7.75, P = 0.59), late complication rate (OR = 0.91, CI: 0.58-1.41, P = 0.56) and stent malfunction (OR = 0.69, CI: 0.42-1.12, P = 0.14) between bilateral and unilateral stenting for malignant hilar biliary strictures. CONCLUSION: Bilateral biliary drainage had a lower re-intervention rate as compared to unilateral drainage for high grade inoperable malignant biliary strictures, with no significant difference in technical success, and early or late complication rates.


Asunto(s)
Neoplasias de los Conductos Biliares/complicaciones , Colestasis/cirugía , Drenaje/métodos , Tumor de Klatskin/complicaciones , Cuidados Paliativos/métodos , Neoplasias de los Conductos Biliares/cirugía , Colestasis/etiología , Constricción Patológica/etiología , Constricción Patológica/cirugía , Drenaje/efectos adversos , Drenaje/instrumentación , Conducto Hepático Común/patología , Conducto Hepático Común/cirugía , Humanos , Tumor de Klatskin/cirugía , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Reoperación/estadística & datos numéricos , Stents/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
18.
JGH Open ; 2(2): 47-53, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30483563

RESUMEN

BACKGROUND AND AIM: Intestinal dysmotility is considered a risk factor for small intestinal bacterial overgrowth (SIBO). Prokinetics improve intestinal motility and are often prescribed with proton pump inhibitors (PPIs) in patients with gastroesophageal reflux disease (GERD) and/or functional dyspepsia. The present study aimed to evaluate the prevalence of SIBO and the orocecal transit time (OCTT) in patients taking PPI compared with those taking PPI plus prokinetics. METHODS: The study is a single-center, cross-sectional study. Enrolled patients (with age > 12 years) were divided into two groups: patients taking PPIs for more than 3 months (Group A) and those taking PPIs with prokinetics for more than 3 months (Group B) for various indications. Lactulose breath test (LBT) for OCTT and glucose breath test (GBT) for SIBO were conducted for all patients. RESULTS: Of the 147 enrolled patients, SIBO was documented in 13.2% patients in Group A versus 1.8% in Group B, P = 0.018. Median OCTT in Group A was 130 (105-160) min compared with 120 (92.5-147.5) min in Group B (P = 0.010). Median OCTT among SIBO-positive patients was 160 (140-172.5) min compared with SIBO-negative patients, where it was 120 (103.75-150) min (P = 0.002). The duration and type of PPI used were not associated with the occurrence of SIBO in our study. CONCLUSION: The use of prokinetics in patients on PPI may reduce the risk of SIBO by enhancing intestinal motility and may reduce SIBO risk associated with long-term PPI use.

19.
Am J Med Sci ; 356(6): 531-536, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30342719

RESUMEN

BACKGROUND: Inflammatory bowel disease (IBD) can have autoimmunity and/or intestinal barrier dysfunction as part of pathophysiology and may be refractory to all available treatment options. Serum-derived bovine immunoglobulin (SBI) binds microbial components with postulated downstream effects of normalized gut immune and barrier function, which may be useful for managing IBD. The purpose of our study was to evaluate the effectiveness of SBI in the management of refractory IBD, particularly symptoms of chronic diarrhea and loose stools. METHODS: We retrospectively analyzed charts for patients diagnosed with IBD (n = 40) who were refractory to standard treatment. Patients received oral SBI 5 g daily for a period of at least 6 weeks. Twelve patients with IBD fulfilled study inclusion criteria. Each patient graded the severity and frequency of gastrointestinal symptoms before starting SBI and at 6 weeks of treatment using a standardized patient assessment form. Means and standard deviations for all symptom scores at baseline and week 6 of treatment were analyzed. RESULTS: Mean symptom scores decreased significantly for nausea (P = 0.02 for severity and P = 0.03 for mean symptom score) and diarrhea (P = 0.0006, P = 0.0001 and P = 0.0001 for severity, frequency and mean symptom score, respectively). CONCLUSIONS: Therapy with SBI alleviated some refractory gastrointestinal symptoms in patients with IBD, including nausea and diarrhea. Increased duration, dosage and/or frequency of SBI might provide additional symptom improvement and could be tested through controlled clinical trials with larger sample sizes and longer follow-up.


Asunto(s)
Diarrea/tratamiento farmacológico , Inmunoglobulinas/uso terapéutico , Factores Inmunológicos/uso terapéutico , Enfermedades Inflamatorias del Intestino/tratamiento farmacológico , Adulto , Anciano , Animales , Bovinos , Diarrea/microbiología , Femenino , Humanos , Enfermedades Inflamatorias del Intestino/microbiología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
20.
Endoscopy ; 49(7): 643-650, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28472833

RESUMEN

Background and aims Early ( < 24 hours) esophagogastroduodenoscopy (EGD) is used to prognosticate mucosal injury after caustic ingestion. We aimed to compare differences in endoscopic grading on EGDs performed on day 5 and day 1 and to assess the impact of relook endoscopy findings on the development of esophageal and/or antropyloric cicatrization. Patients and methods Consecutive patients admitted within 24 hours of caustic ingestion between 2009 and 2014 underwent EGD and had their mucosal changes graded. Injuries of grade ≤ 2a were classified as mild and ≥ 2b were classified as severe. Patients were followed up for the development of cicatrization and managed per protocol. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and likelihood ratios (LRs) were calculated to compare day 1 and day 5 EGD findings. Results A total of 62 patients (35 men; mean age 33 ±â€Š15) underwent both day 1 and day 5 EGDs. Antropyloric stenosis developed in 16 patients, esophageal strictures in nine, and four had both esophageal and antropyloric strictures. Compared with day 1 EGD, endoscopic grading of severe injury on day 5 had higher specificity (83 % vs. 65 %), higher PPV (60 % vs. 41 %), and higher positive LR (5.65 vs. 2.66) for predicting the development of esophageal stricture. Similarly, day 5 endoscopic grading had higher specificity (95 % vs. 61 %), higher PPV (88 % vs. 54 %), and higher positive LR (16 vs. 2.5) for predicting the development of antropyloric stenosis. Conclusion Endoscopic assessment on day 5 is a better predictor of esophageal and gastric cicatrization than day 1 EGD, which significantly overestimates the grade of injury.


Asunto(s)
Quemaduras Químicas/complicaciones , Cáusticos/efectos adversos , Endoscopía Gastrointestinal , Estenosis Esofágica/inducido químicamente , Estenosis Pilórica/inducido químicamente , Adolescente , Adulto , Área Bajo la Curva , Mucosa Esofágica/lesiones , Femenino , Mucosa Gástrica/lesiones , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Curva ROC , Estudios Retrospectivos , Segunda Cirugía , Factores de Tiempo , Índices de Gravedad del Trauma , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA