Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Front Physiol ; 15: 1435848, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39165284

RESUMEN

Introduction: Type 2 diabetes (T2D) is the predominant form of diabetes mellitus and is among the leading causes of death with an increasing prevalence worldwide. However, the pathological mechanism underlying T2D remains complex and unclear. An increasing number of studies have suggested an association between circadian clock disruption and high T2D prevalence. Method: This review explores the physiological and genetic evidence underlying T2D symptoms associated with circadian clock disturbances, including insulin secretion and glucose metabolism. Results and Discussion: Notably, circadian clock disruption reduces insulin secretion and insulin sensitivity and negatively affects glucose homeostasis. The circadian clock regulates the hypothalamic-pituitary-adrenal axis, an important factor that regulates glucose metabolism and influences T2D progression. Therefore, circadian clock regulation is an attractive, novel therapeutic approach for T2D, and various circadian clock stabilizers play therapeutic roles in T2D. Lastly, this review suggests novel therapeutic and preventive approaches using circadian clock regulators for T2D.

2.
J Prosthodont ; 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38594949

RESUMEN

PURPOSE: To introduce a novel design for scan body accessory parts that are reusable, easy to attach and detach without permanent change of the scan body, and can be used with different inter-implant distances to enhance the accuracy of complete arch implant scans. MATERIALS AND METHODS: A maxillary polymethylmethacrylate (PMMA) model with a soft tissue replica was fabricated with four implant analogs located at tooth positions 17, 13, 22, and 27 with 18, 25, and 30 mm inter-implant distances. Four scan bodies (SBs) were attached to the implants. The model was scanned with a laboratory scanner to be used as a reference scan. A total of 40 scans were made with the same intraoral scanner and they were divided equally into two groups. Group A: Complete arch implant scans without scan body accessories (n = 20), and Group B: Complete arch implant scans with scan body accessories (n = 20). Intraoral scans were exported and superimposed on the reference scan using reverse engineering inspection software to be evaluated for 3D deviations, angular deviations, and linear deviations. Statistical analysis was performed with student t-test and analysis of variance (ANOVA) with repeated measures followed by post hoc adjusted Bonferroni test. The level of significance was set at P = 0.05. RESULTS: The scan body accessories decreased both the 3D and linear deviations, with a statistically significant difference at SB4 for the 3D deviation (P = 0.043) and the linear inter-implant discrepancies between SB1-SB2 and SB3-SB4 (P = 0.029 and < 0.001), respectively. However, there was no statistically significant difference in angular deviation between the study groups. Implant positions had significant differences within each group. CONCLUSIONS:  A significant improvement in the accuracy of the complete arch implant digital impression was achieved by using the scan body accessories, particularly in reducing the 3D and linear deviations at the most distant implant positions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...