Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 332
Filtrar
1.
Neuroimage ; : 120742, 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39029606

RESUMEN

PURPOSE: The pathological hallmarks of Alzheimer's disease (AD), amyloid, tau, and associated neurodegeneration, are present in the cortical gray matter (GM) years before symptom onset, and at significantly greater levels in carriers of the apolipoprotein E4 (APOE4) allele. Their respective biomarkers, A/T/N, have been found to correlate with aspects of brain biochemistry, measured with magnetic resonance spectroscopy (MRS), indicating a potential for MRS to augment the A/T/N framework for staging and prediction of AD. Unfortunately, the relationships between MRS and A/T/N biomarkers are unclear, largely due to a lack of studies examining them in the context of the spatial and temporal model of T/N progression. Advanced MRS acquisition and post-processing approaches have enabled us to address this knowledge gap and test the hypotheses, that glutamate-plus-glutamine (Glx) and N-acetyl-aspartate (NAA), metabolites reflecting synaptic and neuronal health, respectively, measured from regions on the Braak stage continuum, correlate with: (i) cerebrospinal fluid (CSF) p-tau181 level (T), and (ii) hippocampal volume or cortical thickness of parietal lobe GM (N). We hypothesized that these correlations will be moderated by Braak stage and APOE4 genotype. METHODS: We conducted a retrospective imaging study of 34 cognitively unimpaired elderly individuals who received APOE4 genotyping and lumbar puncture from pre-existing prospective studies at the NYU Grossman School of Medicine between October 2014 and January 2019. Subjects returned for their imaging exam between April 2018 and February 2020. Metabolites were measured from the left hippocampus (Braak II) using a single-voxel semi-adiabatic localization by adiabatic selective refocusing sequence; and from the bilateral posterior cingulate cortex (PCC; Braak IV), bilateral precuneus (Braak V), and bilateral precentral gyrus (Braak VI) using multi-voxel echo-planar spectroscopic imaging sequence. Pearson and Spearman correlations were used to examine the relationships between absolute levels of choline, creatine, myo-inositol, Glx, and NAA and CSF p-tau181, and between these metabolites and hippocampal volume or parietal cortical thicknesses. Covariates included age, sex, years of education, Fazekas score, and months between CSF collection and MRI exam. RESULTS: There was a direct correlation between hippocampal Glx and CSF p-tau181 in APOE4 carriers (Pearson's r = 0.76, p = 0.02), but not after adjusting for covariates. In the entire cohort, there was a direct correlation between hippocampal NAA and hippocampal volume (Spearman's r = 0.55, p = 0.001), even after adjusting for age and Fazekas score (Spearman's r = 0.48, p = 0.006). This relationship was observed only in APOE4 carriers (Pearson's r = 0.66, p = 0.017), and was also retained after adjustment (Pearson's r = 0.76, p = 0.008; metabolite-by-carrier interaction p = 0.03). There were no findings in the PCC, nor in the negative control (late Braak stage) regions of the precuneus and precentral gyrus. CONCLUSIONS: Our findings are in line with the spatially- and temporally-resolved Braak staging model of pathological severity in which the hippocampus is affected earlier than the PCC. The correlations, between MRS markers of synaptic and neuronal health and, respectively, T and N pathology, were found exclusively within APOE4 carriers, suggesting a connection with AD pathological change, rather than with normal aging. We therefore conclude that MRS has the potential to augment early A/T/N staging, with the hippocampus serving as a more sensitive MRS target compared to the PCC.

2.
MAGMA ; 2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38703246

RESUMEN

OBJECTIVE: Diffusion-weighted MRI is a technique that can infer microstructural and microcirculatory features from biological tissue, with particular application to renal tissue. There is extensive literature on diffusion tensor imaging (DTI) of anisotropy in the renal medulla, intravoxel incoherent motion (IVIM) measurements separating microstructural from microcirculation effects, and combinations of the two. However, interpretation of these features and adaptation of more specific models remains an ongoing challenge. One input to this process is a whole organ distillation of corticomedullary contrast of diffusion metrics, as has been explored for other renal biomarkers. MATERIALS AND METHODS: In this work, we probe the spatial dependence of diffusion MRI metrics with concentrically layered segmentation in 11 healthy kidneys at 3 T. The metrics include those from DTI, IVIM, a combined approach titled "REnal Flow and Microstructure AnisotroPy (REFMAP)", and a multiply encoded model titled "FC-IVIM" providing estimates of fluid velocity and branching length. RESULTS: Fractional anisotropy decreased from the inner kidney to the outer kidney with the strongest layer correlation in both parenchyma (including cortex and medulla) and medulla with Spearman correlation coefficients and p-values (r, p) of (0.42, <0.001) and (0.37, <0.001), respectively. Also, dynamic parameters derived from the three models significantly decreased with a high correlation from the inner to the outer parenchyma or medulla with (r, p) ranges of (0.46-0.55, <0.001). CONCLUSIONS: These spatial trends might find implications for indirect assessments of kidney physiology and microstructure using diffusion MRI.

3.
Eur Radiol ; 34(2): 1113-1122, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37594524

RESUMEN

OBJECTIVES: To evaluate a dynamic half-Fourier acquired single turbo spin echo (HASTE) sequence following anterior cervical discectomy and fusion (ACDF) at the junctional level for adjacent segment degeneration comparing dynamic listhesis to radiographs and assessing dynamic cord contact and deformity during flexion-extension METHODS: Patients with ACDF referred for cervical spine MRI underwent a kinematic flexion-extension sagittal 2D HASTE sequence in addition to routine sequences. Images were independently reviewed by three radiologists for static/dynamic listhesis, and compared to flexion-extension radiographs. Blinded assessment of the HASTE sequence was performed for cord contact/deformity between neutral, flexion, and extension, to evaluate concordance between readers and inter-modality agreement. Inter-reader agreement for dynamic listhesis and impingement grade and inter-modality agreement for dynamic listhesis on MRI and radiographs was assessed using the kappa coefficient and percentage concordance. RESULTS: A total of 28 patients, mean age 60.2 years, were included. Mean HASTE acquisition time was 42 s. 14.3% demonstrated high grade dynamic stenosis (> grade 4) at the adjacent segment. There was substantial agreement for dynamic cord impingement with 70.2% concordance (kappa = 0.62). Concordance across readers for dynamic listhesis using HASTE was 81.0% (68/84) (kappa = 0.16) compared with 71.4% (60/84) (kappa = 0.40) for radiographs. Inter-modality agreement between flexion-extension radiographs and MRI assessment for dynamic listhesis across the readers was moderate (kappa = 0.41; 95% confidence interval: 0.16 to 0.67). CONCLUSIONS: A sagittal flexion-extension HASTE cine sequence provides substantial agreement between readers for dynamic cord deformity and moderate agreement between radiographs and MRI for dynamic listhesis. CLINICAL RELEVANCE STATEMENT: Degeneration of the adjacent segment with instability and myelopathy is one of the most common causes of pain and neurological deterioration requiring re-operation following cervical fusion surgery. KEY POINTS: • A real-time kinematic 2D sagittal HASTE flexion-extension sequence can be used to assess for dynamic listhesis, cervical cord, contact and deformity. • The additional kinematic cine sequence was well tolerated and the mean acquisition time for the 2D HASTE sequence was 42 s (range 31-44 s). • A sagittal flexion-extension HASTE cine sequence provides substantial agreement between readers for dynamic cord deformity and moderate agreement between radiographs and MRI for dynamic listhesis.


Asunto(s)
Vértebras Cervicales , Fusión Vertebral , Humanos , Persona de Mediana Edad , Vértebras Cervicales/diagnóstico por imagen , Vértebras Cervicales/cirugía , Vértebras Cervicales/patología , Fenómenos Biomecánicos , Imagen por Resonancia Magnética/métodos , Radiografía , Discectomía
4.
J Am Coll Radiol ; 21(2): 309-318, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37247831

RESUMEN

OBJECTIVE: To evaluate the efficacy of a multimodal intervention in reducing CT pulmonary angiography (CTPA) overutilization in the evaluation of suspected pulmonary embolism in the emergency department (ED). METHODS: Previous mixed-methods analysis of barriers to guideline-concordant CTPA ordering results was used to develop a provider-focused behavioral intervention consisting of a clinical decision support tool and an audit and feedback system at a multisite, tertiary academic network. The primary outcome (guideline concordance) and secondary outcomes (yield and CTPA and D-dimer order rates) were compared using a pre- and postintervention design. ED encounters for adult patients from July 5, 2017, to January 3, 2019, were included. Fisher's exact tests and statistical process control charts were used to compare the pre- and postintervention groups for each outcome. RESULTS: Of the 201,912 ED patient visits evaluated, 3,587 included CTPA. Guideline concordance increased significantly after the intervention, from 66.9% to 77.5% (P < .001). CTPA order rate and D-dimer order rate also increased significantly, from 17.1 to 18.4 per 1,000 patients (P = .035) and 30.6 to 37.3 per 1,000 patients (P < .001), respectively. Percent yield showed no significant change (12.3% pre- versus 10.8% postintervention; P = .173). Statistical process control analysis showed sustained special-cause variation in the postintervention period for guideline concordance and D-dimer order rates, temporary special-cause variation for CTPA order rates, and no special-cause variation for percent yield. CONCLUSION: Our success in increasing guideline concordance demonstrates the efficacy of a mixed-methods, human-centered approach to behavior change. Given that neither of the secondary outcomes improved, our results may demonstrate potential limitations to the guidelines directing the ordering of CTPA studies and D-dimer ordering.


Asunto(s)
Embolia Pulmonar , Adulto , Humanos , Embolia Pulmonar/diagnóstico por imagen , Servicio de Urgencia en Hospital , Productos de Degradación de Fibrina-Fibrinógeno , Proyectos de Investigación , Angiografía , Tomografía Computarizada por Rayos X , Angiografía por Tomografía Computarizada , Estudios Retrospectivos
5.
Int J Cardiovasc Imaging ; 40(1): 167-176, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37891449

RESUMEN

While there have been many descriptions of characteristic motion findings in left bundle branch block (LBBB), there are few published descriptions of such findings in right bundle branch block (RBBB). The purpose of this study was to assess the frequency of particular regional motion findings in cardiac magnetic resonance imaging (CMR) studies of patients with RBBB, compared with normal subjects. We focused on three distinctive motion patterns that can be seen in RBBB during early systole: delayed apex-ward motion of the RV base, "reverse septal flash", and "basal bulge". The presence and relative magnitude of these findings were independently scored by four experienced observers, in 3-chamber and 4-chamber CMR cines, for both normal subjects and patients with RBBB. These motion patterns were found to be strongly associated with the presence of RBBB. While only moderately sensitive, they were quite specific for RBBB, when present. In particular, with ROC analysis, a combined feature set of the findings in the 4-chamber view had an area under the curve of 0.81.This previously undescribed set of RBBB-associated early-systolic regional motion features (delayed apex-ward motion of the RV base, "reverse septal flash", and "basal bulge") is strongly suggestive of RBBB when present, particularly in the 4-chamber view. Although here evaluated with CMR, it is also likely to be associated with RBBB when seen with other cardiac imaging modalities.


Asunto(s)
Bloqueo de Rama , Imagen por Resonancia Magnética , Humanos , Bloqueo de Rama/diagnóstico por imagen , Bloqueo de Rama/complicaciones , Valor Predictivo de las Pruebas , Corazón , Ventrículos Cardíacos , Electrocardiografía
6.
Magn Reson Imaging ; 100: 93-101, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36924807

RESUMEN

PURPOSE: Diffusion-weighted imaging (DWI) of the abdomen has increased dramatically for both research and clinical purposes. Motion and static field inhomogeneity related challenges limit image quality of abdominopelvic imaging with the most conventional echo-planar imaging (EPI) pulse sequence. While reversed phase encoded imaging is increasingly used to facilitate distortion correction, it typically assumes one motion independent magnetic field distribution. In this study, we describe a more generalized workflow for the case of kidney DWI in which the field inhomogeneity at multiple respiratory phases is mapped and used to correct all images in a multi-contrast DWI series. METHODS: In this HIPAA-compliant and IRB-approved prospective study, 8 volunteers (6 M, ages 28-51) had abdominal imaging performed in a 3 T MRI system (MAGNETOM Prisma; Siemens Healthcare, Erlangen, Germany) with ECG gating. Coronal oblique T2-weighted HASTE images were collected for anatomical reference. Sagittal phase-contrast (PC) MRI images through the left renal artery were collected to determine systolic and diastolic phases. Cardiac triggered oblique coronal DWI were collected at 10 b-values between 0 and 800 s/mm2 and 12 directions. DWI series were distortion corrected using field maps generated by forward and reversed phase encoded b = 0 images collected over the full respiratory cycle and matched by respiratory phase. Morphologic accuracy, intraseries spatial variability, and diffusion tensor imaging (DTI) metrics mean diffusivity (MD) and fractional anisotropy (FA) were compared for results generated with no distortion correction, correction with only one respiratory bin, and correction with multiple respiratory bins across the breathing cycle. RESULTS: Computed field maps showed significant variation in static field with kidney laterality, region, and respiratory phase. Distortion corrected images showed significantly better registration to morphologic images than uncorrected images; for the left kidney, the multiple bin correction outperformed one bin correction. Line profile analysis showed significantly reduced spatial variation with multiple bins than one bin correction. DTI metrics were mostly similar between correction methods, with some differences observed in MD between uncorrected and corrected datasets. CONCLUSIONS: Our results indicate improved morphology of kidney DWI and derived parametric maps as well as reduced variability over the full image series using the motion-resolved distortion correction. This work highlights some morphologic and quantitative metric improvements can be obtained for kidney DWI when distortion correction is performed in a respiratory-resolved manner.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Imagen de Difusión Tensora , Humanos , Adulto , Persona de Mediana Edad , Estudios Prospectivos , Imagen de Difusión por Resonancia Magnética/métodos , Imagen por Resonancia Magnética , Riñón/diagnóstico por imagen , Imagen Eco-Planar/métodos , Movimiento (Física)
7.
Neuroimage Clin ; 37: 103325, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36724732

RESUMEN

PURPOSE: Proton magnetic resonance spectroscopy (1H MRS) offers biomarkers of metabolic damage after mild traumatic brain injury (mTBI), but a lack of replicability studies hampers clinical translation. In a conceptual replication study design, the results reported in four previous publications were used as the hypotheses (H1-H7), specifically: abnormalities in patients are diffuse (H1), confined to white matter (WM) (H2), comprise low N-acetyl-aspartate (NAA) levels and normal choline (Cho), creatine (Cr) and myo-inositol (mI) (H3), and correlate with clinical outcome (H4); additionally, a lack of findings in regional subcortical WM (H5) and deep gray matter (GM) structures (H6), except for higher mI in patients' putamen (H7). METHODS: 26 mTBI patients (20 female, age 36.5 ± 12.5 [mean ± standard deviation] years), within two months from injury and 21 age-, sex-, and education-matched healthy controls were scanned at 3 Tesla with 3D echo-planar spectroscopic imaging. To test H1-H3, global analysis using linear regression was used to obtain metabolite levels of GM and WM in each brain lobe. For H4, patients were stratified into non-recovered and recovered subgroups using the Glasgow Outcome Scale Extended. To test H5-H7, regional analysis using spectral averaging estimated metabolite levels in four GM and six WM structures segmented from T1-weighted MRI. The Mann-Whitney U test and weighted least squares analysis of covariance were used to examine mean group differences in metabolite levels between all patients and all controls (H1-H3, H5-H7), and between recovered and non-recovered patients and their respectively matched controls (H4). Replicability was defined as the support or failure to support the null hypotheses in accordance with the content of H1-H7, and was further evaluated using percent differences, coefficients of variation, and effect size (Cohen's d). RESULTS: Patients' occipital lobe WM Cho and Cr levels were 6.0% and 4.6% higher than controls', respectively (Cho, d = 0.37, p = 0.04; Cr, d = 0.63, p = 0.03). The same findings, i.e., higher patients' occipital lobe WM Cho and Cr (both p = 0.01), but with larger percent differences (Cho, 8.6%; Cr, 6.3%) and effect sizes (Cho, d = 0.52; Cr, d = 0.88) were found in the comparison of non-recovered patients to their matched controls. For the lobar WM Cho and Cr comparisons without statistical significance (frontal, parietal, temporal), unidirectional effect sizes were observed (Cho, d = 0.07 - 0.37; Cr, d = 0.27 - 0.63). No differences were found in any metabolite in any lobe in the comparison between recovered patients and their matched controls. In the regional analyses, no differences in metabolite levels were found in any GM or WM region, but all WM regions (posterior, frontal, corona radiata, and the genu, body, and splenium of the corpus callosum) exhibited unidirectional effect sizes for Cho and Cr (Cho, d = 0.03 - 0.34; Cr, d = 0.16 - 0.51). CONCLUSIONS: We replicated findings of diffuse WM injury, which correlated with clinical outcome (supporting H1-H2, H4). These findings, however, were among the glial markers Cho and Cr, not the neuronal marker NAA (not supporting H3). No differences were found in regional GM and WM metabolite levels (supporting H5-H6), nor in putaminal mI (not supporting H7). Unidirectional effect sizes of higher patients' Cho and Cr within all WM analyses suggest widespread injury, and are in line with the conclusion from the previous publications, i.e., that detection of WM injury may be more dependent upon sensitivity of the 1H MRS technique than on the selection of specific regions. The findings lend further support to the corollary that clinic-ready 1H MRS biomarkers for mTBI may best be achieved by using high signal-to-noise-ratio single-voxels placed anywhere within WM. The biochemical signature of the injury, however, may differ and therefore absolute levels, rather than ratios may be preferred. Future replication efforts should further test the generalizability of these findings.


Asunto(s)
Conmoción Encefálica , Lesiones Encefálicas , Humanos , Femenino , Adulto Joven , Adulto , Persona de Mediana Edad , Espectroscopía de Protones por Resonancia Magnética , Conmoción Encefálica/patología , Espectroscopía de Resonancia Magnética/métodos , Protones , Lesiones Encefálicas/patología , Encéfalo/patología , Ácido Aspártico , Creatina/metabolismo , Colina/metabolismo
8.
Radiology ; 307(2): e220425, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36648347

RESUMEN

Background MRI is a powerful diagnostic tool with a long acquisition time. Recently, deep learning (DL) methods have provided accelerated high-quality image reconstructions from undersampled data, but it is unclear if DL image reconstruction can be reliably translated to everyday clinical practice. Purpose To determine the diagnostic equivalence of prospectively accelerated DL-reconstructed knee MRI compared with conventional accelerated MRI for evaluating internal derangement of the knee in a clinical setting. Materials and Methods A DL reconstruction model was trained with images from 298 clinical 3-T knee examinations. In a prospective analysis, patients clinically referred for knee MRI underwent a conventional accelerated knee MRI protocol at 3 T followed by an accelerated DL protocol between January 2020 and February 2021. The equivalence of the DL reconstruction of the images relative to the conventional images for the detection of an abnormality was assessed in terms of interchangeability. Each examination was reviewed by six musculoskeletal radiologists. Analyses pertaining to the detection of meniscal or ligament tears and bone marrow or cartilage abnormalities were based on four-point ordinal scores for the likelihood of an abnormality. Additionally, the protocols were compared with use of four-point ordinal scores for each aspect of image quality: overall image quality, presence of artifacts, sharpness, and signal-to-noise ratio. Results A total of 170 participants (mean age ± SD, 45 years ± 16; 76 men) were evaluated. The DL-reconstructed images were determined to be of diagnostic equivalence with the conventional images for detection of abnormalities. The overall image quality score, averaged over six readers, was significantly better (P < .001) for the DL than for the conventional images. Conclusion In a clinical setting, deep learning reconstruction enabled a nearly twofold reduction in scan time for a knee MRI and was diagnostically equivalent with the conventional protocol. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Roemer in this issue.


Asunto(s)
Aprendizaje Profundo , Masculino , Humanos , Imagen por Resonancia Magnética/métodos , Articulación de la Rodilla/diagnóstico por imagen , Rodilla/diagnóstico por imagen , Relación Señal-Ruido
9.
Abdom Radiol (NY) ; 48(12): 3634-3642, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-36308554

RESUMEN

PURPOSE: To assess the diagnostic performance of FDG-PET/MRI for the preoperative diagnosis and staging of peritoneal carcinomatosis (PC) using surgical Sugarbaker's PC index (PCI) as the reference in a multireader pilot study. METHODS: Fourteen adult patients (M/F: 3/11, mean age: 57 ± 12 year) with PC were prospectively included in this single-center study. Patients underwent FDG-PET/MRI prior to surgery (mean delay: 14 d, range: 1-63 d). Images were reviewed independently by 2 abdominal radiologists and 2 nuclear medicine physicians. The radiologists assessed contrast-enhanced abdominal MR images, while the nuclear medicine physicians assessed PET images fused with T2-weighted images. The abdomen was divided in 13 regions, scored from 0 to 3. A hybrid FDG-PET/MRI radiological PCI was created by combining the study data. Radiological PCI was compared to the surgical PCI on a per-patient and per-region basis. Inter-reader agreement was evaluated. RESULTS: Mean surgical PCI was 10 ± 8 (range: 0-24). Inter-reader agreement was almost perfect for all sets for radiologic PCI (Kappa: 0.81-0.98). PCI scores for all reading sets significantly correlated with the surgical PCI score (r range: 0.57-0.74, p range: < 0.001-0.003). Pooled per-patient sensitivity, specificity, and accuracy were 75%/50%/71.4% for MRI, 66.7%/50%/64.3% for FDG-PET, and 91.7%/50%/85.7% for FDG-PET/MRI, without significant difference (p value range 0.13-1). FDG-PET/MRI achieved 100% sensitivity and 100% specificity for a cutoff PCI of 20. Per-region sensitivity and accuracy were lower: 37%/61.8% for MRI, 17.8%/64.3% for FDG-PET, and 52.7%/60.4% for FDG-PET/MRI, with significantly higher sensitivity for FDG-PET/MRI. Per-region specificity was higher for FDG-PET (95%) compared to MRI (78.4%) and FDG-PET/MRI (66.5%). CONCLUSION: FDG-PET/MRI achieved an excellent diagnostic accuracy per-patient and weaker performance per-region for detection of PC. The added value of PET/MRI compared to MRI and FDG-PET remains to be determined.


Asunto(s)
Fluorodesoxiglucosa F18 , Neoplasias Peritoneales , Adulto , Humanos , Persona de Mediana Edad , Anciano , Neoplasias Peritoneales/diagnóstico por imagen , Neoplasias Peritoneales/cirugía , Neoplasias Peritoneales/patología , Proyectos Piloto , Estudios Prospectivos , Imagen por Resonancia Magnética/métodos , Tomografía de Emisión de Positrones , Radiofármacos , Estadificación de Neoplasias
10.
J Magn Reson Imaging ; 58(1): 210-220, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36399101

RESUMEN

BACKGROUND: Renal diffusion-weighted imaging (DWI) involves microstructure and microcirculation, quantified with diffusion tensor imaging (DTI), intravoxel incoherent motion (IVIM), and hybrid models. A better understanding of their contrast may increase specificity. PURPOSE: To measure modulation of DWI with cardiac phase and flow-compensated (FC) diffusion gradient waveforms. STUDY TYPE: Prospective. POPULATION: Six healthy volunteers (ages: 22-48 years, five females), water phantom. FIELD STRENGTH/SEQUENCE: 3-T, prototype DWI sequence with 2D echo-planar imaging, and bipolar (BP) or FC gradients. 2D Half-Fourier Single-shot Turbo-spin-Echo (HASTE). Multiple-phase 2D spoiled gradient-echo phase contrast (PC) MRI. ASSESSMENT: BP and FC water signal decays were qualitatively compared. Renal arteries and velocities were visualized on PC-MRI. Systolic (peak velocity), diastolic (end stable velocity), and pre-systolic (before peak velocity) phases were identified. Following mutual information-based retrospective self-registration of DWI within each kidney, and Marchenko-Pastur Principal Component Analysis (MPPCA) denoising, combined IVIM-DTI analysis estimated mean diffusivity (MD), fractional anisotropy (FA), and eigenvalues (λi) from tissue diffusivity (Dt ), perfusion fraction (fp ), and pseudodiffusivity (Dp , Dp,axial , Dp,radial ), for each tissue (cortex/medulla, segmented on b0/FA respectively), phase, and waveform (BP, FC). Monte Carlo water diffusion simulations aided data interpretation. STATISTICAL TESTS: Mixed model regression probed differences between tissue types and pulse sequences. Univariate general linear model analysis probed variations among cardiac phases. Spearman correlations were measured between diffusion metrics and renal artery velocities. Statistical significance level was set at P < 0.05. RESULTS: Water BP and FC signal decays showed no differences. Significant pulse sequence dependence occurred for λ1 , λ3 , FA, Dp , fp , Dp,axial , Dp,radial in cortex and medulla, and medullary λ2 . Significant cortex/medulla differences occurred with BP for all metrics except MD (systole [P = 0.224]; diastole [P = 0.556]). Significant phase dependence occurred for Dp , Dp,axial , Dp,radial for BP and medullary λ1 , λ2 , λ3 , MD for FC. FA correlated significantly with velocity. Monte Carlo simulations indicated medullary measurements were consistent with a 34 µm tubule diameter. DATA CONCLUSION: Cardiac gating and flow compensation modulate of measurements of renal diffusion. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY STAGE: 2.


Asunto(s)
Imagen de Difusión Tensora , Riñón , Femenino , Humanos , Adulto Joven , Adulto , Persona de Mediana Edad , Imagen de Difusión Tensora/métodos , Anisotropía , Estudios Prospectivos , Estudios Retrospectivos , Riñón/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Movimiento (Física) , Agua
11.
J Orthop Surg Res ; 17(1): 42, 2022 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-35065660

RESUMEN

BACKGROUND: Image-guided joint aspirations used to assist the diagnosis of periprosthetic joint infection (PJI) may commonly result in a dry tap-or insufficient fluid for culture and cell count analysis. Dry tap aspirations are painful and invasive for patients and often utilize a subsequent saline lavage to obtain a microbiology sample. Currently, there is a paucity of the literature addressing predictors that could suggest whether a dry tap will occur. The purpose of this study was to examine the effects of various factors on "dry tap" occurrence in patients with suspected PJI following total hip arthroplasty (THA). METHODS: A retrospective review was performed among THA patients suspected for PJI who received image-guided joint aspiration procedures at our institution from May 2016 to February 2020. The procedural factors included the imaging modality used for aspiration, anatomic approach, needle gauge size used, and the presence of a trainee. The patient-specific factors included number of prior ipsilateral hip surgeries, femoral head size, ESR/CRP values, and BMI. RESULTS: In total, 336 patients met our inclusion criteria. One hundred and twenty hip aspirations resulted in a dry tap (35.7%) where the patients underwent a saline lavage. Among the procedural and patient-specific factors, none of the factors were found to be statistically different between the two cohorts nor conferred any greater odds of a dry tap occurring. CONCLUSION: No associations with dry tap occurrence were found among the procedural and patient-specific factors studied. Further research is needed to identify additional factors that may be more predictive of dry taps.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Articulación de la Cadera/cirugía , Prótesis de Cadera , Paracentesis/métodos , Infecciones Relacionadas con Prótesis/etiología , Artroplastia de Reemplazo de Cadera/efectos adversos , Articulación de la Cadera/diagnóstico por imagen , Prótesis de Cadera/efectos adversos , Humanos , Estudios Retrospectivos , Solución Salina , Líquido Sinovial , Irrigación Terapéutica/métodos
12.
Clin Imaging ; 83: 177-183, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35092926

RESUMEN

OBJECTIVE: Texture features are proposed for classification and prognostication, with lacking information about variability. We assessed 3 T liver MRI feature variability. METHODS: Five volunteers underwent standard 3 T MRI, and repeated with identical and altered parameters. Two readers placed regions of interest using 3DSlicer. Repeatability (between standard and repeat scan), robustness (between standard and parameter changed scan), and reproducibility (two reader variation) were computed using coefficient of variation (CV). RESULTS: 67%, 49%, and 61% of features had good-to-excellent (CV ≤ 10%) repeatability on ADC, T1, and T2, respectively, least frequently for first order (19-35%). 22%, 19%, and 21% of features had good-to-excellent robustness on ADC, T1, and T2, respectively. 52%, 35%, and 25% of feature measurements had good-to-excellent inter-reader reproducibility on ADC, T1, and T2, respectively, with highest good-to-excellent reproducibility for first order features on ADC/T1. CONCLUSION: We demonstrated large variations in texture features on 3 T liver MRI. Further study should evaluate methods to reduce variability.


Asunto(s)
Hígado , Imagen por Resonancia Magnética , Humanos , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Reproducibilidad de los Resultados
13.
Eur Radiol ; 32(2): 1308-1319, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34410458

RESUMEN

OBJECTIVES: To assess whether MR fingerprinting (MRF)-based relaxation properties exhibit cross-sectional and prospective correlations with patient outcome and compare the results with those from DTI. METHODS: Clinical imaging, MRF, and DTI were acquired in patients (24 ± 10 days after injury (timepoint 1) and 90 ± 17 days after injury (timepoint 2)) and once in controls. Patient outcome was assessed with global functioning, symptom profile, and neuropsychological testing. ADC and fractional anisotropy (FA) from DTI and T1 and T2 from MRF were compared in 12 gray and white matter regions with Mann-Whitney tests. Bivariate associations between MR measures and outcome were assessed using the Spearman correlation and logistic regression. RESULTS: Data from 22 patients (38 ± 12 years; 17 women) and 18 controls (32 ± 8 years; 12 women) were analyzed. Fourteen patients (37 ± 12 years; 11 women) returned for timepoint 2, while two patients provided only timepoint 2 clinical outcome data. At timepoint 1, there were no differences between patients and controls in T1, T2, and ADC, while FA was lower in mTBI frontal white matter. T1 at timepoint 1 and the change in T1 exhibited more (n = 18) moderate to strong correlations (|r|= 0.6-0.85) with clinical outcome at timepoint 2 than T2 (n = 3), FA (n = 7), and ADC (n = 2). High T1 at timepoint 1, and serially increasing T1, accounted for five of the six MR measures with the highest utility for identification of non-recovered patients at timepoint 2 (AUC > 0.80). CONCLUSION: T1 derived from MRF was found to have higher utility than T2, FA, and ADC for predicting 3-month outcome after mTBI. KEY POINTS: • In a region-of-interest approach, FA, ADC, and T1 and T2 all showed limited utility in differentiating patients from controls at an average of 24 and 90 days post-mild traumatic brain injury. • T1 at 24 days, and the serial change in T1, revealed more and stronger predictive correlations with clinical outcome at 90 days than did T2, ADC, or FA. • T1 showed better prospective identification of non-recovered patients at 90 days than ADC, T2, and FA.


Asunto(s)
Conmoción Encefálica , Encéfalo , Conmoción Encefálica/diagnóstico por imagen , Estudios Transversales , Femenino , Humanos , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Estudios Prospectivos
14.
J Am Coll Radiol ; 19(3): 407-414, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34896068

RESUMEN

OBJECTIVE: To evaluate the impact of structured recommendations on follow-up completion for incidental lung nodules (ILNs). METHODS: Patients with ILNs before and after implementation of structured Fleischner recommendations and electronic tracking were sampled randomly. The cohorts were compared for imaging follow-up. Multivariable logistic regression was used to assess appropriate follow-up and loss to follow-up, with independent variables including use of structured recommendations or tracking, age, sex, race, ethnicity, setting of the index test (inpatient, outpatient, emergency department), smoking history, and nodule features. RESULTS: In all, 1,301 patients met final inclusion criteria, including 255 patients before and 1,046 patients after structured recommendations or tracking. Baseline differences were found in the pre- and postintervention groups, with smaller ILNs and younger age after implementing structured recommendations. Comparing pre- versus postintervention outcomes, 40.0% (100 of 250) versus 29.5% (309 of 1,046) of patients had no follow-up despite Fleischner indications for imaging (P = .002), and among the remaining patients, 56.6% (82 of 145) versus 75.0% (553 of 737) followed up on time (P < .001). Delayed follow-up was more frequent before intervention. Differences postintervention were mostly accounted for by nodules ≤8 mm in the outpatient setting (P < .001). In multivariable analysis, younger age, White race, outpatient setting, and larger nodule size showed significant association with appropriate follow-up completion (P < .015), but structured recommendations did not. Similar results applied for loss to follow-up. DISCUSSION: Consistent use of structured reporting is likely key to mitigate selection bias when benchmarking rates of appropriate follow-up of ILN. Emergency department patients and inpatients are at high risk of missed or delayed follow-up despite structured recommendations.


Asunto(s)
Neoplasias Pulmonares , Nódulo Pulmonar Solitario , Electrónica , Humanos , Hallazgos Incidentales , Pulmón , Neoplasias Pulmonares/diagnóstico por imagen , Nódulo Pulmonar Solitario/diagnóstico por imagen
15.
Acad Radiol ; 28(9): 1185-1190, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34266739

RESUMEN

RATIONALE AND OBJECTIVES: The COVID-19 pandemic stresses the tenuous balance between domestic obligations and academic output for women across professions. Our investigation aims to evaluate the impact of the pandemic on the home duties and workplace productivity of academic radiologists with respect to gender. MATERIALS AND METHODS: A 49-question survey was distributed to 926 members of Association of University Radiologists in October 2020. Several categories were addressed: demographics; workplace changes; stress levels and personal experiences with illness; time spent on domestic obligations; and perception of productivity during COVID-19. Statistical analyses were performed using SAS version 9.4 software (SAS Institute, Cary, NC). RESULTS: A total of 96 responses across 30 states, 53.1% male and 46.9% female were received. Women report spending more time on unpaid domestic duties than men prior to COVID-19, with men spending a median of 5-10 h/wk and women spending a median of 10-15 h/wk (p = 0.043). With pandemic onset, both genders reported that women did more of the homecare, when not split equally. Women with young children reported a significant decrease in work-from-home productivity compared to men with young children (p = 0.007). Men reported they had more time to be productive compared to women (p = 0.012). CONCLUSION: The COVID-19 pandemic threatens to disrupt the advancement of women in radiology leadership roles by creating disparate effects on productivity due to increased workloads at home for women. This could potentially lead to decreases in promotions and research productivity in years to come that far outlast the acute phases of the pandemic.


Asunto(s)
COVID-19 , Radiología , Movilidad Laboral , Niño , Preescolar , Docentes Médicos , Femenino , Humanos , Masculino , Pandemias , SARS-CoV-2 , Factores Sexuales
16.
Cereb Cortex Commun ; 2(2): tgab015, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34296161

RESUMEN

Myelin abnormalities have been reported in schizophrenia spectrum disorders (SSD) in white matter. However, in vivo examinations of cortical myeloarchitecture in SSD, especially those using quantitative measures, are limited. Here, we employed macromolecular proton fraction (MPF) obtained from quantitative magnetization transfer imaging to characterize intracortical myelin organization in 30 SSD patients versus 34 healthy control (HC) participants. We constructed cortical myelin profiles by extracting MPF values at various cortical depths and quantified their shape using a nonlinearity index (NLI). To delineate the association of illness duration with myelin changes, SSD patients were further divided into 3 duration groups. Between-group comparisons revealed reduced NLI in the SSD group with the longest illness duration (>5.5 years) compared with HC predominantly in bilateral prefrontal areas. Within the SSD group, cortical NLI decreased with disease duration and was positively associated with a measure of spatial working memory capacity as well as with cortical thickness (CT). Layer-specific analyses suggested that NLI decreases in the long-duration SSD group may arise in part from significantly increased MPF values in the midcortical layers. The current study reveals cortical myelin profile changes in SSD with illness progression, which may reflect an abnormal compensatory mechanism of the disorder.

17.
Brain Commun ; 3(2): fcab051, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33928248

RESUMEN

The pathological cascade of tissue damage in mild traumatic brain injury is set forth by a perturbation in ionic homeostasis. However, whether this class of injury can be detected in vivo and serve as a surrogate marker of clinical outcome is unknown. We employ sodium MRI to test the hypotheses that regional and global total sodium concentrations: (i) are higher in patients than in controls and (ii) correlate with clinical presentation and neuropsychological function. Given the novelty of sodium imaging in traumatic brain injury, effect sizes from (i), and correlation types and strength from (ii), were compared to those obtained using standard diffusion imaging metrics. Twenty-seven patients (20 female, age 35.9 ± 12.2 years) within 2 months after injury and 19 controls were scanned with proton and sodium MRI at 3 Tesla. Total sodium concentration, fractional anisotropy and apparent diffusion coefficient were obtained with voxel averaging across 12 grey and white matter regions. Linear regression was used to obtain global grey and white matter total sodium concentrations. Patient outcome was assessed with global functioning, symptom profiles and neuropsychological function assessments. In the regional analysis, there were no statistically significant differences between patients and controls in apparent diffusion coefficient, while differences in sodium concentration and fractional anisotropy were found only in single regions. However, for each of the 12 regions, sodium concentration effect sizes were uni-directional, due to lower mean sodium concentration in patients compared to controls. Consequently, linear regression analysis found statistically significant lower global grey and white matter sodium concentrations in patients compared to controls. The strongest correlation with outcome was between global grey matter sodium concentration and the composite z-score from the neuropsychological testing. In conclusion, both sodium concentration and diffusion showed poor utility in differentiating patients from controls, and weak correlations with clinical presentation, when using a region-based approach. In contrast, sodium linear regression, capitalizing on partial volume correction and high sensitivity to global changes, revealed high effect sizes and associations with patient outcome. This suggests that well-recognized sodium imbalances in traumatic brain injury are (i) detectable non-invasively; (ii) non-focal; (iii) occur even when the antecedent injury is clinically mild. Finally, in contrast to our principle hypothesis, patients' sodium concentrations were lower than controls, indicating that the biological effect of traumatic brain injury on the sodium homeostasis may differ from that in other neurological disorders. Note: This figure has been annotated.

18.
Cartilage ; 13(1_suppl): 1315S-1323S, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-31455091

RESUMEN

OBJECTIVE: The outcome of arthroscopic treatment for femoroacetabular impingement (FAI) depends on the preoperative status of the hip cartilage. Quantitative T2 can detect early biochemical cartilage changes, but its routine implementation is challenging. Furthermore, intrinsic T2 variability between patients makes it difficult to define a threshold to identify cartilage lesions. To address this, we propose a normalized T2-index as a new method to evaluate cartilage in FAI. DESIGN: We retrospectively analyzed magnetic resonance imaging (MRI) data of 18 FAI patients with arthroscopically confirmed cartilage defects. Cartilage T2 maps were reconstructed from multi-spin-echo 3-T data using the echo-modulation-curve (EMC) model-based technique. The central femoral cartilage, assumed healthy in early-stage FAI, was used as the normalization reference to define a T2-index. We investigated the ability of the T2-index to detect surgically confirmed cartilage lesions. RESULTS: The average T2-index was 1.14 ± 0.1 and 1.13 ± 0.1 for 2 separated segmentations. Using T2-index >1 as the threshold for damaged cartilage, accuracy was 88% and 100% for the 2 segmentations. We found moderate intraobserver repeatability, although separate segmentations yielded comparable accuracy. Damaged cartilage could not be identified using nonnormalized average T2 values. CONCLUSIONS: This preliminary study confirms the importance of normalizing T2 values to account for interpatient variability and suggests that the T2-index is a promising biomarker for the detection of cartilage lesions in FAI. Future work is needed to confirm that combining T2-index with morphologic MRI and other quantitative biomarkers could improve cartilage assessment in FAI.


Asunto(s)
Artroscopía , Cartílago Articular/diagnóstico por imagen , Pinzamiento Femoroacetabular/cirugía , Pinzamiento Femoroacetabular/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Estudios Retrospectivos
19.
Clin Breast Cancer ; 21(1): e74-e79, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32828665

RESUMEN

BACKGROUND: Emerging data suggest screening mammography may be effective in detecting breast cancer early in high-risk men. We evaluated current screening recommendations as a risk management strategy in men at elevated risk for breast cancer. PATIENTS AND METHODS: This institutional review board-approved, Health Insurance Portability and Accountability Act (HIPAA)-compliant study reviewed consecutive men who underwent genetic counseling and multigene panel testing (MGPT) for breast cancer risk assessment at our institution between 2012 and 2018. Patient risk factors, test indications, and MGPT outcomes were recorded, then correlated with screening recommendations by either clinical breast examination or screening mammography. Recommendation consistency among practitioners was evaluated. Patient adherence to screening mammography (defined as undergoing screening mammography as recommended) was assessed. Statistical analysis was performed at the 2-sided 5% significance level. RESULTS: A total of 414 asymptomatic men underwent both genetic counseling and MGPT (mean age, 47 years; range, 18-91 years) for breast cancer risk assessment. Of this group, 18 (4.3%) of 414 had a personal history of breast cancer, and 159 (38.4%) of 414 had a family history of breast cancer before MGPT. Among 112 men with positive MGPT results, BRCA1/2 mutations were the most common (56.3%, 63/112). Most BRCA mutation carriers (80.9%, 51/63) were recommended clinical breast examination only. Only 5.9% (2/34) BRCA2 and 10.3% (3/29) BRCA1 carriers were recommended screening mammograms (7.9%, 5/63 of all BRCA carriers). Among men with a personal history of breast cancer, only 9 (50%) of 18 were recommended screening mammograms. Overall adherence to screening mammogram in men was 71.4% (10/14), which ultimately yielded two cancers. Breast cancer screening recommendations varied widely among practitioners, with some recommending clinical breast examination only, and others also recommending mammography. CONCLUSION: Men who are found to be at an elevated risk for breast cancer after undergoing genetic counseling and testing currently receive relatively inconsistent screening recommendations.


Asunto(s)
Neoplasias de la Mama Masculina/diagnóstico , Detección Precoz del Cáncer/estadística & datos numéricos , Asesoramiento Genético/estadística & datos numéricos , Pruebas Genéticas/estadística & datos numéricos , Adulto , Anciano , Predisposición Genética a la Enfermedad/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Mutación
20.
Brain ; 144(1): 213-223, 2021 02 12.
Artículo en Inglés | MEDLINE | ID: mdl-33253366

RESUMEN

The aim of this study was to determine the feasibility of diffusion basis spectrum imaging in multiple sclerosis at 7 T and to investigate the pathological substrates of tissue damage in lesions and normal-appearing white matter. To this end, 43 patients with multiple sclerosis (24 relapsing-remitting, 19 progressive), and 21 healthy control subjects were enrolled. White matter lesions were classified in T1-isointense, T1-hypointense and black holes. Mean values of diffusion basis spectrum imaging metrics (fibres, restricted and non-restricted fractions, axial and radial diffusivities and fractional anisotropy) were measured from whole brain white matter lesions and from both lesions and normal appearing white matter of the corpus callosum. Significant differences were found between T1-isointense and black holes (P ranging from 0.005 to <0.001) and between lesions' centre and rim (P < 0.001) for all the metrics. When comparing the three subject groups in terms of metrics derived from corpus callosum normal appearing white matter and T2-hyperintense lesions, a significant difference was found between healthy controls and relapsing-remitting patients for all metrics except restricted fraction and fractional anisotropy; between healthy controls and progressive patients for all metrics except restricted fraction and between relapsing-remitting and progressive multiple sclerosis patients for all metrics except fibres and restricted fractions (P ranging from 0.05 to <0.001 for all). Significant associations were found between corpus callosum normal-appearing white matter fibres fraction/non-restricted fraction and the Symbol Digit Modality Test (respectively, r = 0.35, P = 0.043; r = -0.35, P = 0.046), and between black holes radial diffusivity and Expanded Disability Status Score (r = 0.59, P = 0.002). We showed the feasibility of diffusion basis spectrum imaging metrics at 7 T, confirmed the role of the derived metrics in the characterization of lesions and normal appearing white matter tissue in different stages of the disease and demonstrated their clinical relevance. Thus, suggesting that diffusion basis spectrum imaging is a promising tool to investigate multiple sclerosis pathophysiology, monitor disease progression and treatment response.


Asunto(s)
Axones/patología , Imagen de Difusión por Resonancia Magnética/métodos , Encefalitis/diagnóstico por imagen , Esclerosis Múltiple/diagnóstico por imagen , Vaina de Mielina/patología , Sustancia Blanca/diagnóstico por imagen , Adulto , Encefalitis/complicaciones , Encefalitis/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Esclerosis Múltiple/complicaciones , Sustancia Blanca/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...