Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 13(1): 19856, 2023 Nov 13.
Artículo en Inglés | MEDLINE | ID: mdl-37963926

RESUMEN

Mössbauer spectroscopy is a nuclear spectroscopic technique that measures changes in energy on an atomic scale. In a Mössbauer spectrometer, a velocity modulator oscillates a radioactive source to vary the energy of gamma rays. Conventional velocity modulators use wires primarily as motion guides; however, the tension state of these wires may change over time. Membrane springs are thus used as an alternative to wires; however, they also present certain challenges related to their design, manufacturing, and assembly. Instead of wires or membrane springs, this study used a linear bearing with preloaded compression springs. The advantage of this mechanism is that permanent deformation or changes in spring stiffness minimally occur during spring assembly and operation. The developed velocity modulator is compact and light, making it ideal for portable applications. A digital controller is used to easily modify and customize control parameters and the supporting algorithm, which is not easily achieved with conventional analog controllers. Moreover, by applying a switching amplifier, low-power operation is also achieved. Feedforward control values are calculated by an iterative learning method that is robust to the control of repeated motion. Using finite element method simulations and experiments, the performance of the developed prototype was evaluated. The velocity signal demonstrated linearity with a correlation with a straight line of approximately 0.996 for a triangular velocity profile (satisfactory performance).

2.
Med Phys ; 42(6): 2805-12, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26127032

RESUMEN

PURPOSE: In radiotherapy, metallic implants often detach from their deposited sites and migrate to other locations. This undesirable migration could cause inadequate dose coverage for permanent brachytherapy and difficulties in image-guided radiation delivery for patients. To prevent migration of implanted seeds, the authors propose a potential strategy to use a biocompatible and tissue-adhesive material called polydopamine. METHODS: In this study, nonradioactive dummy seeds that have the same geometry and composition as commercial I-125 seeds were coated in polydopamine. Using scanning electron microscopy and x-ray photoelectron spectroscopy, the surface of the polydopamine-coated and noncoated seeds was characterized. The detachment stress between the two types of seeds and the tissue was measured. The efficacy of polydopamine-coated seed was investigated through in vitro migration tests by tracing the seed location after tissue implantation and shaking for given times. The cytotoxicity of the polydopamine coating was also evaluated. RESULTS: The results of the coating characterization have shown that polydopamine was successfully coated on the surface of the seeds. In the adhesion test, the polydopamine-coated seeds had 2.1-fold greater detachment stress than noncoated seeds. From the in vitro test, it was determined that the polydopamine-coated seed migrated shorter distances than the noncoated seed. This difference was increased with a greater length of time after implantation. CONCLUSIONS: The authors suggest that polydopamine coating is an effective technique to prevent migration of implanted seeds, especially for permanent prostate brachytherapy.


Asunto(s)
Braquiterapia/métodos , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/metabolismo , Metales/química , Metales/metabolismo , Movimiento , Adhesividad , Animales , Línea Celular , Materiales Biocompatibles Revestidos/toxicidad , Indoles/química , Hígado/citología , Hígado/diagnóstico por imagen , Hígado/metabolismo , Ratones , Polímeros/química , Dosificación Radioterapéutica , Porcinos , Tomografía Computarizada por Rayos X
3.
J Appl Clin Med Phys ; 14(5): 25-42, 2013 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-24036857

RESUMEN

Phase-based respiratory-gated radiotherapy relies on the reproducibility of patient breathing during the treatment. To monitor the positional reproducibility of patient breathing against a 4D CT simulation, we developed a real-time motion verification system (RMVS) using an optical tracking technology. The system in the treatment room was integrated with a real-time position management system. To test the system, an anthropomorphic phantom that was mounted on a motion platform moved on a programmed breathing pattern and then underwent a 4D CT simulation with RPM. The phase-resolved anterior surface lines were extracted from the 4D CT data to constitute 4D reference lines. In the treatment room, three infrared reflective markers were attached on the superior, middle, and inferior parts of the phantom along with the body midline and then RMVS could track those markers using an optical camera system. The real-time phase information extracted from RPM was delivered to RMVS via in-house network software. Thus, the real-time anterior-posterior positions of the markers were simultaneously compared with the 4D reference lines. The technical feasibility of RMVS was evaluated by repeating the above procedure under several scenarios such as ideal case (with identical motion parameters between simulation and treatment), cycle change, baseline shift, displacement change, and breathing type changes (abdominal or chest breathing). The system capability for operating under irregular breathing was also investigated using real patient data. The evaluation results showed that RMVS has a competence to detect phase-matching errors between patient's motion during the treatment and 4D CT simulation. Thus, we concluded that RMVS could be used as an online quality assurance tool for phase-based gating treatments.


Asunto(s)
Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador , Técnicas de Imagen Sincronizada Respiratorias , Contencion de la Respiración , Tomografía Computarizada Cuatridimensional , Humanos , Masculino , Movimiento (Física) , Órganos en Riesgo , Fantasmas de Imagen , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...