Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
J Proteome Res ; 23(3): 1049-1061, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38372774

RESUMEN

Elucidating antibody-antigen complexes at the atomic level is of utmost interest for understanding immune responses and designing better therapies. Cross-linking mass spectrometry (XL-MS) has emerged as a powerful tool for mapping protein-protein interactions, suggesting valuable structural insights. However, the use of XL-MS studies to enable epitope/paratope mapping of antibody-antigen complexes is still limited up to now. XL-MS data can be used to drive integrative modeling of antibody-antigen complexes, where cross-links information serves as distance restraints for the precise determination of binding interfaces. In this approach, XL-MS data are employed to identify connections between binding interfaces of the antibody and the antigen, thus informing molecular modeling. Current literature provides minimal input about the impact of XL-MS data on the integrative modeling of antibody-antigen complexes. Here, we applied XL-MS to retrieve information about binding interfaces of three antibody-antigen complexes. We leveraged XL-MS data to perform integrative modeling using HADDOCK (active-passive residues and distance restraints strategies) and AlphaLink2. We then compared these three approaches with initial predictions of investigated antibody-antigen complexes by AlphaFold Multimer. This work emphasizes the importance of cross-linking data in resolving conformational dynamics of antibody-antigen complexes, ultimately enhancing the design of better protein therapeutics and vaccines.


Asunto(s)
Complejo Antígeno-Anticuerpo , Espectrometría de Masas , Mapeo Epitopo
2.
Eur J Pharm Sci ; 188: 106502, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37336420

RESUMEN

Preclinical in vivo and in vitro characterization of Antibody-Drug Conjugates (ADCs) involves the development of several bioanalytical methods to address many drug exposure questions. The current pharma industry approach requires at least three different assays that must be run, i.e., total antibody (mAb), conjugated payload or conjugated mAb, and free payload assays. Herein we present analytical performances of a quantitative hybrid Ligand Binding/Liquid Chromatography High Resolution and Accuracy Mass Spectrometry (LB/LCHRAM) method that can condense much of the necessary bioanalytical information in one method. The method includes an immuno-capture step, and it detects whole ADC molecules. It was applied to plasma mouse samples and showed reliable bioanalytical performance according to full method validation standards. Quantitation using extracted ion chromatograms and deconvoluted mass peaks was evaluated. The limit of quantitation resulted in 0.5ng of protein on column with a linear dynamic range spanning from 0.5 to 10µg/mL. Moreover, lower drug-to-antibody ratio (DAR) ADC species can be simultaneously detected, also enabling qualitative characterization of in vivo ADC conjugation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA