Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
J Immunol Methods ; 527: 113649, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38395105

RESUMEN

While the single-platform flow cytometric CD34+ cell counting method is the preferred choice to predict the yield of mobilized peripheral blood stem cells, most flow cytometers lack the ability of hematology counter analyzers to perform volumetric counting. However, one of the problems using reference microbeads is the vanishing counting bead phenomenon. This phenomenon results in a drop in microbeads concentration and reduces the total and relative number of beads in calibration procedures. In the last years, flow cytometers including a volumetric system to quantify cells have been developed and may represent a promising alternative to enumerate CD34+ cells avoiding the use of beads. In this study we have used a direct true volumetric counting of CD34+ cells under continuous flow pump to overcome potential drawbacks with impact in rare cell analysis. To confirm this hypothesis, we have compared the results of CD34+ cell enumeration using non-volumetric vs. volumetric systems with FC500 (Beckman Coulter) and Attune NxT (ThermoFisher) flow cytometers, respectively, in mobilized peripheral blood samples. No statistically significant differences were observed between measurements of CD34+ cells using beads, when the FC500 and Attune NxT absolute counting values were compared, or when CD34+ counts were compared on the Attune NxT, either using or not using beads. Linear regressions to study the relationship between volumetric and non-volumetric CD34+ counts confirmed the accuracy of each method. Bland-Altman test showed agreement between both methods. Our data showed that CD34+ cell enumeration using a volumetric system is comparable with current counting systems. This method represents an alternative with the advantage of the simplification of sample preparation and the reduction of the analysis subjectivity.


Asunto(s)
Citometría de Flujo , Citometría de Flujo/métodos , Recuento de Células , Modelos Lineales , Antígenos CD34 , Microesferas
2.
Int J Mol Sci ; 25(4)2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38396682

RESUMEN

Leukemic stem cells (LSCs) possess similar characteristics to normal hematopoietic stem cells, including self-renewal capacity, quiescence, ability to initiate leukemia, and drug resistance. These cells play a significant role in leukemia relapse, persisting even after apparent remission. LSCs were first described in 1994 by Lapidot et al. Although they have been extensively studied in acute leukemia, more LSC research is still needed in chronic lymphocytic leukemia (CLL) to understand if reduced apoptosis in mature cells should still be considered as the major cause of this disease. Here, we provide new evidence suggesting the existence of stem-like cell populations in CLL, which may help to understand the disease as well as to develop effective treatments. In this study, we identified a potential leukemic stem cell subpopulation using the tetraploid CLL cell line I83. This subpopulation is characterized by diploid cells that were capable of generating the I83 tetraploid population. Furthermore, we adapted a novel flow cytometry analysis protocol to detect CLL subpopulations with stem cell properties in peripheral blood samples and primary cultures from CLL patients. These cells were identified by their co-expression of CD19 and CD5, characteristic markers of CLL cells. As previously described, increased alkaline phosphatase (ALP) activity is indicative of stemness and pluripotency. Moreover, we used this method to investigate the potential synergistic effect of curcumin in combination with fludarabine and ibrutinib to deplete this subpopulation. Our results confirmed the effectiveness of this ALP-based analysis protocol in detecting and monitoring leukemic stem-like cells in CLL. This analysis also identified limitations in eradicating these populations using in vitro testing. Furthermore, our findings demonstrated that curcumin significantly enhanced the effects of fludarabine and ibrutinib on the leukemic fraction, exhibiting synergistic effects (combination drug index, CDI 0.97 and 0.37, respectively). Our results lend support to the existence of potential stem-like populations in CLL cell lines, and to the idea that curcumin could serve as an effective adjuvant in therapies aimed at eliminating these populations and improving treatment efficacy.


Asunto(s)
Adenina/análogos & derivados , Curcumina , Leucemia Linfocítica Crónica de Células B , Piperidinas , Vidarabina/análogos & derivados , Humanos , Leucemia Linfocítica Crónica de Células B/metabolismo , Curcumina/farmacología , Curcumina/uso terapéutico , Tetraploidía
3.
Cytometry A ; 103(5): 447-454, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36114620

RESUMEN

Doublet discrimination is usually based on pulse analysis of light scatter parameters. A combination of two pulse parameters (Area, A; Height, H; or Width, W) can be used to discriminate a pulse originated in a single cell from a pulse originated from cells stuck together. Fluorescence signals can be also used to discriminate aggregates, being essential to identify cells in the G2/M phase from doublets in the G0/G1 phase in cell cycle/DNA applications. The most used method combines FSC-A versus FSC-H, whereas other strategies combine FSC-H versus FSC-W, SSC-H versus SSC-A and SSC-H versus SSC-W. However, when studying activated or proliferating cells, scatter discrimination can be difficult. In this study, we have compared the use of light scattering with fluorescence measurement techniques for successful doublet discrimination for single cells. Effective use of FSC and SSC height, area and width are commonly used to eliminate aggregates. However, fluorescence-based methods using viable DNA stains provide a good compromise between performance and accurate manual gating methods, especially for highly concentrated cell products and pathological specimens. Viable DNA dyes, such as Vybrant™ DyeCycle™ Violet stain or Hoechst 33342, can be used to detect nucleated cells in blood and in bone marrow, or to discriminate cell aggregates and debris based on no-lyse no-wash assays, where scatter degradation is a dominant component of the measured data, which increases with event rate.


Asunto(s)
ADN , Citometría de Flujo/métodos , Ciclo Celular , ADN/análisis
4.
Cytometry B Clin Cytom ; 100(4): 519-530, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-32961011

RESUMEN

INTRODUCTION: Pre-analytical and analytical errors can threaten the reliability of flow cytometry (FC) results. A potential solution to some of these is the use of dry, pre-mixed antibodies, such as the ClearLLab 10C system. The purpose of the present study was to compare the diagnostic performance of the ClearLLab 10C B cell tube with that of our standard laboratory practice. METHODS: We compared the diagnoses made with the ClearLLab 10C B cell tube (experimental strategy) with those made with standard laboratory practice (standard strategy). Samples were selected aiming for representation of the full spectrum of B cell disorders, with an emphasis on mature B cell malignancies, as well as healthy controls. RESULTS: We included 116 samples (34 normal controls, 4 acute lymphoblastic leukemias, 54 mature lymphoproliferative disorders in peripheral blood and bone marrow, 3 myelomas, 6 bone marrow samples with involvement by lymphoma and 1 with elevated hematogone count, 14 lymph node samples, 1 cerebrospinal fluid, and 1 pleural effusion). There were two diagnostic errors (1.7%). The agreement between the two strategies in the percentage of CD19 cells and fluorescence intensity of CD5, CD19, CD20, CD200, and CD10 was very good. CONCLUSIONS: In this study, the ClearLLab 10C B cell tube performed similarly to our standard laboratory practice to diagnose and classify mature B cell malignancies.


Asunto(s)
Linfocitos B/inmunología , Citometría de Flujo/instrumentación , Inmunofenotipificación/instrumentación , Trastornos Linfoproliferativos/sangre , Antígenos CD/sangre , Antígenos CD19/sangre , Antígenos CD20/sangre , Linfocitos B/patología , Femenino , Citometría de Flujo/métodos , Humanos , Inmunofenotipificación/métodos , Leucemia Linfocítica Crónica de Células B/sangre , Leucemia Linfocítica Crónica de Células B/diagnóstico , Leucemia Linfocítica Crónica de Células B/patología , Leucemia Linfoide/sangre , Leucemia Linfoide/patología , Linfoma/sangre , Linfoma/patología , Trastornos Linfoproliferativos/diagnóstico , Trastornos Linfoproliferativos/inmunología , Trastornos Linfoproliferativos/patología , Masculino , Neprilisina/sangre
5.
Curr Protoc Cytom ; 93(1): e76, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32543779

RESUMEN

Translational research has improved the diagnosis and follow-up of hematological diseases and malignancies. However, some classical diagnostics used for research and clinical practice that have remain practically unchanged for decades may be better addressed through advances in flow cytometry technology, whereby more precise measurements may be implemented in a straightforward manner. The current method for semiquantitative analysis of granulocytic alkaline phosphatase (GAP) activity is still based on observer-dependent color-intensity classification. Here, we describe a novel strategy for flow cytometric quantification of GAP activity in which staining and analytical flow cytometry facilitate the detection and quantification of subpopulations of leukocytes with different GAP activities. Our experiments demonstrate the potential of flow cytometry as a simple and highly sensitive approach for measuring GAP activity in unlysed whole blood. Notably, a comparison of flow cytometry and enzyme cytochemistry techniques showed that enzyme activity scores were not similar, indicating that results needs to be interpreted with caution, given that the enzyme-substrate binding affinities may differ, as well as the subjective evaluation of the intensity of the precipitated dye. © 2020 Wiley Periodicals LLC. Basic Protocol: Protocol preparation, sample acquisition, and gating strategy for flow cytometric identification of alkaline phosphatase activity in granulocytes from whole blood samples Support Protocol 1: Sample preparation for granulocyte alkaline phosphatase determination by flow cytometry using no-lyse no-wash methods Support Protocol 2: Data analysis and formula to calculate the GAP score.


Asunto(s)
Fosfatasa Alcalina/sangre , Citometría de Flujo/métodos , Granulocitos/enzimología , Análisis de Datos , Humanos
6.
Sci Rep ; 8(1): 15705, 2018 10 24.
Artículo en Inglés | MEDLINE | ID: mdl-30356059

RESUMEN

Distortions of the normal bi-concave disc shape for red blood cells (RBCs) appear in a number of pathologies resulting from defects in cell membrane skeletal architecture, erythrocyte ageing, and mechanical damage. We present here the potential of acoustic cytometry for developing new approaches to light-scattering based evaluation of red blood cell disorders and of the effects of storage and ageing on changes or damage to RBCs membranes. These approaches could be used to immediately evaluate the quality of erythrocytes prior to blood donation and following transfusion. They could also be applied to studying RBC health in diseases and other pathologies, such as artificial heart valve hemolysis, thermal damage or osmotic fragility. Abnormal distributions of erythrocytes can typically be detected after just 30 to 45 seconds of acquisition time using 1-2 µL starting blood volumes.


Asunto(s)
Eritrocitos , Citometría de Flujo/métodos , Sonido , Anexina A5 , Conservación de la Sangre/métodos , Envejecimiento Eritrocítico , Deformación Eritrocítica , Índices de Eritrocitos , Membrana Eritrocítica/ultraestructura , Transfusión de Eritrocitos , Eritrocitos/ultraestructura , Citometría de Flujo/instrumentación , Colorantes Fluorescentes , Hemólisis , Humanos , Hidrodinámica , Luz , Lípidos de la Membrana/sangre , Fosfatidilserinas/sangre , Dispersión de Radiación , Esferocitos/ultraestructura , Esferocitosis Hereditaria/sangre
7.
J Immunol ; 198(8): 3099-3108, 2017 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-28250158

RESUMEN

Soluble factors released from platelets can modulate the immune response of leukocytes. We and others have recently found that T lymphocytes with bound platelets have reduced proliferation and IFN-γ and IL-17 production. Thus, we speculate that if we induce the binding of platelets to lymphocytes, we will be able to regulate the inflammatory response. When we cocultured platelets with lymphocytes at different ratios, we were able to increase the percentage of lymphocytes with bound platelets. The coculture of platelets with lymphocytes in the presence of stimulation decreased the production of IFN-γ and TNF-α, T cell proliferation, and the expression of CD25, PD-L1, and SLAM. However, this coculture increased CD39 expression. All of these effects were dependent on the dose of platelets and operated indistinctly with platelets from different healthy donors. When platelets were cocultured in the same compartment with lymphocytes, we observed less IFN-γ and TNF-α production and T lymphocyte proliferation than in cultures with platelets separated from lymphocytes by a 0.4-µm pore size filter. The binding of platelets to lymphocytes was blocked with anti-P-selectin Abs, and when this occurred we observed higher IFN-γ and TNF-α production than in nonblocked conditions. The cocultures of platelets with synovial fluid cells from rheumatoid arthritis patients reduced inflammatory cytokine production and increased IL-10 production. These results suggest that platelet binding to lymphocytes effectively regulates T lymphocyte function. This mechanism could be easily applied to reduce inflammatory responses.


Asunto(s)
Artritis Reumatoide/inmunología , Plaquetas/inmunología , Citocinas/biosíntesis , Activación de Linfocitos/inmunología , Linfocitos T/inmunología , Técnicas de Cocultivo , Femenino , Citometría de Flujo , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA