Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 96
Filtrar
1.
Radiat Res ; 199(6): 535-555, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-37310880

RESUMEN

Tools for radiation exposure reconstruction are required to support the medical management of radiation victims in radiological or nuclear incidents. Different biological and physical dosimetry assays can be used for various exposure scenarios to estimate the dose of ionizing radiation a person has absorbed. Regular validation of the techniques through inter-laboratory comparisons (ILC) is essential to guarantee high quality results. In the current RENEB inter-laboratory comparison, the performance quality of established cytogenetic assays [dicentric chromosome assay (DCA), cytokinesis-block micronucleus assay (CBMN), stable chromosomal translocation assay (FISH) and premature chromosome condensation assay (PCC)] was tested in comparison to molecular biological assays [gamma-H2AX foci (gH2AX), gene expression (GE)] and physical dosimetry-based assays [electron paramagnetic resonance (EPR), optically or thermally stimulated luminescence (LUM)]. Three blinded coded samples (e.g., blood, enamel or mobiles) were exposed to 0, 1.2 or 3.5 Gy X-ray reference doses (240 kVp, 1 Gy/min). These doses roughly correspond to clinically relevant groups of unexposed to low exposed (0-1 Gy), moderately exposed (1-2 Gy, no severe acute health effects expected) and highly exposed individuals (>2 Gy, requiring early intensive medical care). In the frame of the current RENEB inter-laboratory comparison, samples were sent to 86 specialized teams in 46 organizations from 27 nations for dose estimation and identification of three clinically relevant groups. The time for sending early crude reports and more precise reports was documented for each laboratory and assay where possible. The quality of dose estimates was analyzed with three different levels of granularity, 1. by calculating the frequency of correctly reported clinically relevant dose categories, 2. by determining the number of dose estimates within the uncertainty intervals recommended for triage dosimetry (±0.5 Gy or ±1.0 Gy for doses <2.5 Gy or >2.5 Gy), and 3. by calculating the absolute difference (AD) of estimated doses relative to the reference doses. In total, 554 dose estimates were submitted within the 6-week period given before the exercise was closed. For samples processed with the highest priority, earliest dose estimates/categories were reported within 5-10 h of receipt for GE, gH2AX, LUM, EPR, 2-3 days for DCA, CBMN and within 6-7 days for the FISH assay. For the unirradiated control sample, the categorization in the correct clinically relevant group (0-1 Gy) as well as the allocation to the triage uncertainty interval was, with the exception of a few outliers, successfully performed for all assays. For the 3.5 Gy sample the percentage of correct classifications to the clinically relevant group (≥2 Gy) was between 89-100% for all assays, with the exception of gH2AX. For the 1.2 Gy sample, an exact allocation to the clinically relevant group was more difficult and 0-50% or 0-48% of the estimates were wrongly classified into the lowest or highest dose categories, respectively. For the irradiated samples, the correct allocation to the triage uncertainty intervals varied considerably between assays for the 1.2 Gy (29-76%) and 3.5 Gy (17-100%) samples. While a systematic shift towards higher doses was observed for the cytogenetic-based assays, extreme outliers exceeding the reference doses 2-6 fold were observed for EPR, FISH and GE assays. These outliers were related to a particular material examined (tooth enamel for EPR assay, reported as kerma in enamel, but when converted into the proper quantity, i.e. to kerma in air, expected dose estimates could be recalculated in most cases), the level of experience of the teams (FISH) and methodological uncertainties (GE). This was the first RENEB ILC where everything, from blood sampling to irradiation and shipment of the samples, was organized and realized at the same institution, for several biological and physical retrospective dosimetry assays. Almost all assays appeared comparably applicable for the identification of unexposed and highly exposed individuals and the allocation of medical relevant groups, with the latter requiring medical support for the acute radiation scenario simulated in this exercise. However, extreme outliers or a systematic shift of dose estimates have been observed for some assays. Possible reasons will be discussed in the assay specific papers of this special issue. In summary, this ILC clearly demonstrates the need to conduct regular exercises to identify research needs, but also to identify technical problems and to optimize the design of future ILCs.


Asunto(s)
Bioensayo , Recolección de Muestras de Sangre , Estudios Retrospectivos , Citocinesis , Espectroscopía de Resonancia por Spin del Electrón
2.
Radiat Res ; 197(1): 36-42, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-33652474

RESUMEN

Epidemiological studies suggest an increased incidence and risk of cataract after low-dose (<2 Gy) ionizing radiation exposures. However, the biological mechanism(s) of this process are not fully understood. DNA damage and repair are thought to have a contributing role in radiation-induced cataractogenesis. Recently we have reported an inverse dose-rate effect, as well as the low-dose response, of DNA damage and repair in lens epithelial cells (LECs). Here, we present further initial findings from two mutated strains (Ercc2+/- and Ptch1+/-) of mice, both reportedly susceptible to radiation-induced cataract, and their DNA damage and repair response to low-dose and low-dose-rate gamma rays. Our results support the hypothesis that the lens epithelium responds differently to radiation than other tissues, with reported radiation susceptibility to DNA damage not necessarily translating to the LECs. Genetic predisposition and strain(s) of mice have a significant role in radiation-induced cataract susceptibility.


Asunto(s)
Catarata/etiología , Daño del ADN/efectos de la radiación , Cristalino/efectos de los fármacos , Animales , Células Epiteliales , Rayos gamma , Humanos , Ratones , Receptor Patched-1/metabolismo , Exposición a la Radiación , Proteína de la Xerodermia Pigmentosa del Grupo D/metabolismo
3.
Radiat Res ; 197(1): 92-99, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-33984857

RESUMEN

Lens epithelial cell proliferation and differentiation are naturally well regulated and controlled, a characteristic essential for lens structure, symmetry and function. The effect of ionizing radiation on lens epithelial cell proliferation has been demonstrated in previous studies at high acute doses, but the effect of dose and dose rate on proliferation has not yet been considered. In this work, mice received single acute doses of 0.5, 1 and 2 Gy of radiation, at dose rates of 0.063 and 0.3 Gy/min. Eye lenses were isolated postirradiation at 30 min up until 14 days and flat-mounted. Then, cell proliferation rates were determined using biomarker Ki67. As expected, radiation increased cell proliferation 2 and 24 h postirradiation transiently (undetectable 14 days postirradiation) and was dose dependent (changes were very significant at 2 Gy; P = 0.008). A dose-rate effect did not reach significance in this study (P = 0.054). However, dose rate and lens epithelial cell region showed significant interactions (P < 0.001). These observations further our mechanistic understanding of how the lens responds to radiation.


Asunto(s)
Cristalino/efectos de la radiación , Animales , Diferenciación Celular/efectos de la radiación , Proliferación Celular/efectos de la radiación , Relación Dosis-Respuesta en la Radiación , Células Epiteliales , Femenino , Humanos , Ratones Endogámicos C57BL , Dosis de Radiación , Exposición a la Radiación , Radiación Ionizante
4.
Radiat Res ; 197(1): 57-66, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-33984859

RESUMEN

Recent epidemiological findings and reanalysis of historical data suggest lens opacities resulting from ionizing radiation exposures are likely induced at lower doses than previously thought. These observations have led to ICRP recommendations for a reduction in the occupational dose limits for the eye lens, as well as subsequent implementation in EU member states. The EU CONCERT LDLensRad project was initiated to further understand the effects of ionizing radiation on the lens and identify the mechanism(s) involved in radiation-induced cataract, as well as the impact of dose and dose-rate. Here, we present the results of a long-term study of changes to lens opacity in male and female adult mice from a variety of different genetic (radiosensitive or radioresistant) backgrounds, including mutant strains Ercc2 and Ptch1, which were assumed to be susceptible to radiation-induced lens opacities. Mice received 0.5, 1 and 2 Gy 60Co gamma-ray irradiation at dose rates of 0.063 and 0.3 Gy min-1. Scheimpflug imaging was used to quantify lens opacification as an early indicator of cataract, with monthly observations taken postirradiation for an 18-month period in all strains apart from 129S2, which were observed for 12 months. Opacification of the lens was found to increase with time postirradiation (with age) for most mouse models, with ionizing radiation exposure increasing opacities further. Sex, dose, dose rate and genetic background were all found to be significant contributors to opacification; however, significant interactions were identified, which meant that the impact of these factors was strain dependent. Mean lens density increased with higher dose and dose rate in the presence of Ercc2 and Ptch1 mutations. This project was the first to focus on low (<1 Gy) dose, multiple dose rate, sex and strain effects in lens opacification, and clearly demonstrates the importance of these experimental factors in radiobiological investigations on the lens. The results provide insight into the effects of ionizing radiation on the lens as well as the need for further work in this area to underpin appropriate radiation protection legislation and guidance.


Asunto(s)
Catarata/etiología , Animales , Femenino , Antecedentes Genéticos , Humanos , Cristalino/efectos de la radiación , Masculino , Ratones , Ratones Endogámicos BALB C , Ratones Endogámicos C57BL , Exposición Profesional , Receptor Patched-1/metabolismo , Dosis de Radiación , Exposición a la Radiación , Radiación Ionizante , Proteína de la Xerodermia Pigmentosa del Grupo D/metabolismo
5.
J Plast Reconstr Aesthet Surg ; 73(8): 1448-1455, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32291186

RESUMEN

INTRODUCTION: Chest wall sarcomas are rare. Resection and reconstruction pose significant anatomical and functional challenges. We present our experience of managing these tumours as plastic surgeons working within a specialist sarcoma MDT. METHODS: All cases of chest wall sarcoma in which a plastic surgeon took part were analysed (2003-2016). Tumours of the breast, abdomen and groin were excluded. Demographics, surgical details and outcomes were analysed. RESULTS: Forty-seven patients were identified. Median age at presentation was 61 years (range 7-91). Thirty-three were male and 14 were female. Chondrosarcoma (n = 16) was the most frequently occurring tumour, followed by myxofibrosarcoma (n = 6), leiomyosarcoma (n = 5) and unclassified sarcomas (n = 5). The majority of tumours were of high (n = 16) or intermediate grade (n = 17) histologically. Wide local excision was carried out in all cases. Twenty-two cases required a mesh and cement reconstruction of the chest wall. Soft tissue reconstruction involved pedicled LD flap +-skin graft (n = 17), direct closure (n = 13), pedicled VRAM (n = 7), free ALT flap (n = 6), and others (n = 4). Clear resection margins were achieved in 32 patients (68%). Fourteen patients underwent adjuvant radiotherapy and four adjuvant chemotherapy. Nine patients (19%) developed a local recurrence, and the median duration from resection to recurrence was 17 months (range 3-72). Nine patients (19%) developed metastasis. Eleven patients died (23.4%), and the median duration of survival 30 months (range 3-92). Thirty-six patients remain well, with a median duration of follow up 57.5 months (range 6-141). Estimated 5 year disease specific survival is 74.2%. CONCLUSION: Plastic surgeons have a vital role in the management of chest wall sarcomas. We present a reconstructive algorithm, which has enabled us to achieve good oncological and functional outcomes and a low complication profile .


Asunto(s)
Sarcoma/cirugía , Neoplasias Torácicas/cirugía , Pared Torácica/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Procedimientos de Cirugía Plástica
6.
Clin Radiol ; 74(10): 816.e9-816.e17, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31375261

RESUMEN

AIM: To determine cumulative scan frequencies and estimate lens dose for paediatric computed tomography (CT) head examinations in the context of potential cataract risk. MATERIALS AND METHODS: The cumulative number of head-region CT examinations among a cohort of 410,997 children and young adults who underwent CT in the UK between 1985 and 2014 was calculated. Images from a sample of these head examinations (n=668) were reviewed to determine the level of eye inclusion. Lens dose per scan was estimated using the computer program, NCICT V1.0, for different levels of eye inclusion and exposure settings typical of past and present clinical practice. RESULTS: In total 284,878 patients underwent 448,108 head-region CT examinations. The majority of patients (72%) had a single recorded head-region examination. A small subset (∼1%, n=2,494) underwent ≥10 examinations, while 0.1% (n=387) underwent ≥20. The lens was included within the imaged region for 57% of reviewed routine head examinations. In many cases, this appeared to be intentional, i.e. protocol driven. In others, there appeared to have been an attempt to exclude the eyes through gantry angulation. Estimated lens doses were 20-75 mGy (mean: 47 mGy) where the eye was fully included within the examination range and 2-7 mGy (mean: 3.1 mGy) where the lens was fully excluded. Potential cumulative lens doses ranged from ∼3 mGy to ∼4,700 mGy, with 2,335 patients potentially receiving >500 mGy. CONCLUSION: The majority of young people will receive cumulative lens doses well below 500 mGy, meaning the risk of cataract induction is likely to be very small.


Asunto(s)
Cabeza/diagnóstico por imagen , Cristalino/efectos de la radiación , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Adolescente , Catarata/etiología , Catarata/prevención & control , Niño , Preescolar , Estudios de Cohortes , Relación Dosis-Respuesta en la Radiación , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Posicionamiento del Paciente , Exposición a la Radiación/efectos adversos , Adulto Joven
7.
Clin Microbiol Infect ; 25(7): 865-871, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30391581

RESUMEN

OBJECTIVES: We conducted a cluster-randomized feasibility trial of 90-minute Chlamydia trachomatis tests and same day on-site treatment ('Test n Treat/TnT') in six technical colleges in London, England, to assess TnT uptake rates; follow-up rates; prevalence of C. trachomatis at baseline and 7 months; time to treatment; acceptability of TnT. METHODS: Participants completed questionnaires and provided genitourinary samples at baseline and 7 months. Participants were informed that baseline samples would not be tested for 7 months and were advised to get screened independently. Colleges were randomly allocated 1:1 to intervention (TnT) or control (no TnT). One month and 4 months post recruitment, participants at intervention colleges were texted invitations for on-site free C. trachomatis tests. A purposive sample of students who did/did not attend for screening were interviewed (n = 26). RESULTS: Five hundred and nine sexually active students were recruited: median age 17.9 years, 47% male, 50% black ethnicity, 55% reporting two or more sexual partners in the previous year. TnT uptake was 13% (33/259; 95% CI 8.9-17.4%) at 1 month and 10% (26/259; 6.7-14.4%) at 4 months with overall C. trachomatis positivity 5.1% (3/59; 1.1-14.2%). Follow-up at 7 months was 62% (317/509) for questionnaires and 52% (264/509) for samples. C. trachomatis prevalence was 6.2% (31/503) at baseline and 6.1% (16/264) at 7 months. Median time from test to treatment was 15 h. Interviews suggested low test uptake was associated with not feeling at risk, perceptions of stigma, and little knowledge of sexually transmitted infections (STIs). CONCLUSIONS: Despite high C. trachomatis rates at baseline and follow-up, uptake of testing was low. Like many countries, England urgently needs better sex education, including making STI testing routine/normal. Trial registration ISRCTN58038795.


Asunto(s)
Infecciones por Chlamydia/diagnóstico , Infecciones por Chlamydia/tratamiento farmacológico , Chlamydia trachomatis/aislamiento & purificación , Enfermedades de Transmisión Sexual/diagnóstico , Enfermedades de Transmisión Sexual/tratamiento farmacológico , Adolescente , Infecciones por Chlamydia/epidemiología , Programas de Detección Diagnóstica , Etnicidad , Estudios de Factibilidad , Femenino , Humanos , Londres/epidemiología , Masculino , Prevalencia , Factores de Riesgo , Conducta Sexual , Parejas Sexuales , Enfermedades de Transmisión Sexual/epidemiología , Estudiantes , Encuestas y Cuestionarios , Tiempo de Tratamiento , Adulto Joven
8.
Mar Pollut Bull ; 135: 739-758, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30301093

RESUMEN

Many offshore oil and gas production facilities are nearing the end of their operational life, with decommissioning now becoming a global challenge. The compatibility of decommissioning operations to marine protected areas (MPAs) creates further challenges. The recently-developed DAPSI(W)R(M) problem structuring framework (covering Drivers, Activities, Pressures, State changes, Impacts (on Welfare) and Responses (as Measures)) was applied here to interrogate the complexity of decommissioning oil and gas infrastructure within MPAs, with outputs feeding into the development of a novel database tool for Screening Potential Impacts of Decommissioning Activities (SPIDA). In meeting the current requirements of the marine regulatory regime, SPIDA provides a more streamlined, evidence-based process which can be applied by industry, statutory nature conservation bodies and regulators for identifying and evaluating evidence that supports the implications of decommissioning alternatives on the condition of MPAs. SPIDA has been developed to be adapted for other activities and sectors, including offshore renewables.


Asunto(s)
Conservación de los Recursos Hídricos/métodos , Bases de Datos Factuales , Yacimiento de Petróleo y Gas , Animales , Técnicas de Apoyo para la Decisión , Ecosistema , Ambiente
9.
Int J Radiat Biol ; 94(12): 1116-1124, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30359158

RESUMEN

PURPOSE: Epidemiological evidence regarding the radiosensitivity of the lens of the eye and radiation cataract development has led to changes in the EU Basic Safety Standards for protection of the lens against ionizing radiation. However, mechanistic details of lens radiation response pathways and their significance for cataractogenesis remain unclear. Radiation-induced DNA damage and the potential impairment of repair pathways within the lens epithelium, a cell monolayer that covers the anterior hemisphere of the lens, are likely to be involved. MATERIALS AND METHODS: In this work, the lens epithelium has been analyzed for its DNA double-strand break (DSB) repair response to ionizing radiation. The responses of epithelial cells located at the anterior pole (central region) have been compared to at the very periphery of the monolayer (germinative and transitional zones). Described here are the different responses in the two regions and across four strains (C57BL/6, 129S2, BALB/c and CBA/Ca) over a low dose (0-25 mGy) in-vivo whole body X-irradiation range up to 24 hours post exposure. RESULTS: DNA damage and repair as visualized through 53BP1 staining was present across the lens epithelium, although repair kinetics appeared non-uniform. Epithelial cells in the central region have significantly more 53BP1 foci. The sensitivities of different mouse strains have also been compared. CONCLUSIONS: 129S2 and BALB/c showed higher levels of DNA damage, with BALB/c showing significantly less inter-individual variability and appearing to be a more robust model for future DNA damage and repair studies. As a result of this study, BALB/c was identified as a suitable radiosensitive lens strain to detect and quantify early low dose ionizing radiation DNA damage effects in the mouse eye lens specifically, as an indicator of cataract formation.


Asunto(s)
Daño del ADN , Cristalino/metabolismo , Cristalino/efectos de la radiación , Animales , Reparación del ADN/efectos de la radiación , Relación Dosis-Respuesta en la Radiación , Epitelio/metabolismo , Epitelio/efectos de la radiación , Ratones , Ratones Endogámicos BALB C , Ratones Endogámicos C57BL , Tolerancia a Radiación/genética , Especificidad de la Especie , Factores de Tiempo
10.
Br J Dermatol ; 179(3): 662-668, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29569226

RESUMEN

BACKGROUND: Germline mutations in the tumour suppressor gene CYLD are recognized to be associated with the development of multiple cutaneous cylindromas. We encountered such a patient who presented with breathlessness because of multiple pulmonary cylindromas. OBJECTIVES: To search for clinical and radiological features of multiple pulmonary cylindromas in a cohort of 16 patients with CYLD mutations. METHODS: A retrospective case-note review was carried out in a tertiary dermatogenetics clinic where CYLD mutation carriers are reviewed on an annual basis. In-depth investigation was carried out for patients with pulmonary tumours. RESULTS: Four patients had radiological imaging of their lungs, of which two had multiple pulmonary cylindromas that were confirmed histologically. Serial computed tomography monitoring allowed for pre-emptive endobronchial laser ablation, preventing major airway obstruction and pulmonary collapse. CONCLUSIONS: Pulmonary cylindromas are an unrecognized, but infrequently symptomatic, aspect of the phenotype in these patients that can have implications for patient care. They should be considered in patients with a high tumour burden that present with respiratory symptoms, and where appropriate, monitored with serial imaging.


Asunto(s)
Portador Sano/patología , Enzima Desubiquitinante CYLD/genética , Disnea/etiología , Neoplasias Pulmonares/secundario , Síndromes Neoplásicos Hereditarios/patología , Neoplasias Cutáneas/patología , Adulto , Anciano , Portador Sano/diagnóstico por imagen , Análisis Mutacional de ADN , Femenino , Mutación de Línea Germinal , Humanos , Pulmón/diagnóstico por imagen , Neoplasias Pulmonares/complicaciones , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/genética , Masculino , Persona de Mediana Edad , Síndromes Neoplásicos Hereditarios/diagnóstico por imagen , Síndromes Neoplásicos Hereditarios/genética , Estudios Retrospectivos , Neoplasias Cutáneas/diagnóstico por imagen , Neoplasias Cutáneas/genética
11.
Vet Rec ; 178(1): 18, 2016 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-26612859

RESUMEN

In many European shelters, dogs may spend many years confined. A poor environment and inappropriate management may lead to a low quality of life. The absence of harmonised European regulatory frameworks defining the minimum requirements for shelter facilities makes the definition of welfare standards for kennelled dogs challenging. Here, a new protocol was developed and tested to help identify the main welfare issues for shelter dogs. Twenty-six indicators were identified including management, resource and animal based measures. Accuracy and interobserver reliability were checked between four assessors. The protocol was applied in 29 shelters (n=1308 dogs) in six European countries. Overall prevalence of poor health conditions was below 10%. Test-retest reliability and validity of the protocol were investigated with encouraging results. A logistic regression was carried out to assess the potential of the protocol as a tool to identify welfare hazards in shelter environments. Inappropriate space allowance, for example, was found to be a risk factor potentially affecting the animal's cleanliness, skin condition and body condition. The protocol was designed to be concise and easy to implement. Systematic data collection could help identify welfare problems that are likely to arise in certain shelter designs and thus determine improvement in animal care standards.


Asunto(s)
Bienestar del Animal/organización & administración , Bienestar del Animal/normas , Vivienda para Animales/normas , Animales , Perros , Europa (Continente) , Estudios de Factibilidad , Vivienda para Animales/estadística & datos numéricos , Factores de Tiempo
13.
Ann ICRP ; 44(1 Suppl): 84-90, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25816262

RESUMEN

The recommendation from the International Commission on Radiological Protection that the occupational equivalent dose limit for the lens of the eye should be reduced to 20 mSv year(-1), averaged over 5 years with no year exceeding 50 mSv, has stimulated a discussion on the practicalities of implementation of this revised dose limit, and the most appropriate risk and protection framework to adopt. This brief paper provides an overview of some of the drivers behind the move to a lower recommended dose limit. The issue of implementation in the medical sector in the UK has been addressed through a small-scale survey of doses to the lens of the eye amongst interventional cardiologists and radiologists. In addition, a mechanistic study of early and late post-irradiation changes in the lens of the eye in in-vivo-exposed mice is outlined. Surveys and studies such as those described can contribute to a deeper understanding of fundamental and practical issues, and therefore contribute to a robust evidence base for ensuring adequate protection of the eye while avoiding undesirable restrictions to working practices.


Asunto(s)
Oftalmopatías/etiología , Cristalino/efectos de la radiación , Exposición Profesional , Oftalmología , Optometría , Traumatismos por Radiación/etiología , Animales , Oftalmopatías/patología , Oftalmopatías/fisiopatología , Humanos , Ratones , Dosis de Radiación , Traumatismos por Radiación/patología , Traumatismos por Radiación/fisiopatología , Riesgo , Reino Unido
14.
Radiat Prot Dosimetry ; 164(3): 265-70, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25118318

RESUMEN

In the event of a mass casualty radiation incident, the gamma-H2AX foci assay could be a useful tool to estimate radiation doses received by individuals. The rapid processing time of blood samples of just a few hours and the potential for batch processing, enabling high throughput, make the assay ideal for early triage categorisation to separate the 'worried well' from the low and critically exposed by quantifying radiation-induced foci in peripheral blood lymphocytes. Within the RENEB framework, 8 European laboratories have taken part in the first European gamma-H2AX biodosimetry exercise, which consisted of a telescoring comparison of 200 circulated foci images taken from 8 samples, and a comparison of 10 fresh blood lymphocyte samples that were shipped overnight to participating labs 4 or 24 h post-exposure. Despite large variations between laboratories in the dose-response relationship for foci induction, the obtained results indicate that the network should be able to use the gamma-H2AX assay for rapidly identifying the most severely exposed individuals within a cohort who could then be prioritised for accurate chromosome dosimetry.


Asunto(s)
Bioensayo/métodos , Daño del ADN/genética , Rayos gamma , Histonas/genética , Linfocitos/efectos de la radiación , Exposición a la Radiación/análisis , Células Cultivadas , Relación Dosis-Respuesta en la Radiación , Europa (Continente) , Técnica del Anticuerpo Fluorescente , Humanos , Laboratorios , Linfocitos/fisiología , Incidentes con Víctimas en Masa , Dosis de Radiación , Liberación de Radiactividad Peligrosa
15.
Radiat Prot Dosimetry ; 164(1-2): 42-5, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25205835

RESUMEN

Creating a sustainable network in biological and retrospective dosimetry that involves a large number of experienced laboratories throughout the European Union (EU) will significantly improve the accident and emergency response capabilities in case of a large-scale radiological emergency. A well-organised cooperative action involving EU laboratories will offer the best chance for fast and trustworthy dose assessments that are urgently needed in an emergency situation. To this end, the EC supports the establishment of a European network in biological dosimetry (RENEB). The RENEB project started in January 2012 involving cooperation of 23 organisations from 16 European countries. The purpose of RENEB is to increase the biodosimetry capacities in case of large-scale radiological emergency scenarios. The progress of the project since its inception is presented, comprising the consolidation process of the network with its operational platform, intercomparison exercises, training activities, proceedings in quality assurance and horizon scanning for new methods and partners. Additionally, the benefit of the network for the radiation research community as a whole is addressed.


Asunto(s)
Bioensayo/métodos , Planificación en Desastres/organización & administración , Traumatismos por Radiación/prevención & control , Monitoreo de Radiación/métodos , Protección Radiológica/métodos , Liberación de Radiactividad Peligrosa/prevención & control , Urgencias Médicas , Europa (Continente) , Humanos , Exposición a la Radiación/prevención & control , Administración de la Seguridad/organización & administración
16.
Health Phys ; 106(6): 764-71, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24776911

RESUMEN

Large scale radiological emergencies require high throughput techniques of biological dosimetry for population triage in order to identify individuals indicated for medical treatment. The dicentric assay is the "gold standard" technique for the performance of biological dosimetry, but it is very time consuming and needs well trained scorers. To increase the throughput of blood samples, semi-automation of dicentric scoring was investigated in the framework of the MULTIBIODOSE EU FP7 project, and dose effect curves were established in six biodosimetry laboratories. To validate these dose effect curves, blood samples from 33 healthy donors (>10 donors/scenario) were irradiated in vitro with 6°Co gamma rays simulating three different exposure scenarios: acute whole body, partial body, and protracted exposure, with three different doses for each scenario. All the blood samples were irradiated at Ghent University, Belgium, and then shipped blind coded to the participating laboratories. The blood samples were set up by each lab using their own standard protocols, and metaphase slides were prepared to validate the calibration curves established by semi-automatic dicentric scoring. In order to achieve this, 300 metaphases per sample were captured, and the doses were estimated using the newly formed dose effect curves. After acute uniform exposure, all laboratories were able to distinguish between 0 Gy, 0.5 Gy, 2.0, and 4.0 Gy (p < 0.001), and, in most cases, the dose estimates were within a range of ± 0.5 Gy of the given dose. After protracted exposure, all laboratories were able to distinguish between 1.0 Gy, 2.0 Gy, and 4.0 Gy (p < 0.001), and here also a large number of the dose estimates were within ± 0.5 Gy of the irradiation dose. After simulated partial body exposure, all laboratories were able to distinguish between 2.0 Gy, 4.0 Gy, and 6.0 Gy (p < 0.001). Overdispersion of the dicentric distribution enabled the detection of the partial body samples; however, this result was clearly dose-dependent. For partial body exposures, only a few dose estimates were in the range of ± 0.5 Gy of the given dose, but an improvement could be achieved with higher cell numbers. The new method of semi-automation of the dicentric assay was introduced successfully in a network of six laboratories. It is therefore concluded that this method can be used as a high-throughput screening tool in a large-scale radiation accident.


Asunto(s)
Aberraciones Cromosómicas/efectos de la radiación , Modelos Biológicos , Radiometría/métodos , Automatización , Calibración , Relación Dosis-Respuesta en la Radiación , Humanos
17.
Radiat Prot Dosimetry ; 159(1-4): 87-94, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24743767

RESUMEN

Within the EU MULTIBIODOSE project, the automated micronucleus (MN) assay was optimised for population triage in large-scale radiological emergencies. For MN scoring, two approaches were applied using the Metafer4 platform (MetaSystems, Germany): fully automated scoring and semi-automated scoring with visual inspection of the gallery of MN-positive objects. Dose-response curves were established for acute and protracted whole-body and partial-body exposures. A database of background MN yields was set up, allowing determination of the dose detection threshold in both scoring modes. An analysis of the overdispersion of the MN frequency distribution σ(2)/µ obtained by semi-automated scoring showed that the value of this parameter represents a reliability check of the calculated equivalent total body dose in case the accident overexposure is a partial-body exposure. The elaborated methodology was validated in an accident training exercise. Overall, the semi-automated scoring procedure represents important added value to the automated MN assay.


Asunto(s)
Planificación en Desastres/organización & administración , Linfocitos/efectos de la radiación , Pruebas de Micronúcleos/métodos , Traumatismos por Radiación/diagnóstico , Monitoreo de Radiación/métodos , Triaje/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Automatización , Simulación por Computador , Relación Dosis-Respuesta en la Radiación , Femenino , Rayos gamma , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Traumatismos por Radiación/sangre , Adulto Joven
18.
Radiat Environ Biophys ; 53(2): 241-54, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24557539

RESUMEN

In the case of a large scale radiation accident high throughput methods of biological dosimetry for population triage are needed to identify individuals requiring clinical treatment. The dicentric assay performed in web-based scoring mode may be a very suitable technique. Within the MULTIBIODOSE EU FP7 project a network is being established of 8 laboratories with expertise in dose estimations based on the dicentric assay. Here, the manual dicentric assay was tested in a web-based scoring mode. More than 23,000 high resolution images of metaphase spreads (only first mitosis) were captured by four laboratories and established as image galleries on the internet (cloud). The galleries included images of a complete dose effect curve (0-5.0 Gy) and three types of irradiation scenarios simulating acute whole body, partial body and protracted exposure. The blood samples had been irradiated in vitro with gamma rays at the University of Ghent, Belgium. Two laboratories provided image galleries from Fluorescence plus Giemsa stained slides (3 h colcemid) and the image galleries from the other two laboratories contained images from Giemsa stained preparations (24 h colcemid). Each of the 8 participating laboratories analysed 3 dose points of the dose effect curve (scoring 100 cells for each point) and 3 unknown dose points (50 cells) for each of the 3 simulated irradiation scenarios. At first all analyses were performed in a QuickScan Mode without scoring individual chromosomes, followed by conventional scoring (only complete cells, 46 centromeres). The calibration curves obtained using these two scoring methods were very similar, with no significant difference in the linear-quadratic curve coefficients. Analysis of variance showed a significant effect of dose on the yield of dicentrics, but no significant effect of the laboratories, different methods of slide preparation or different incubation times used for colcemid. The results obtained to date within the MULTIBIODOSE project by a network of 8 collaborating laboratories throughout Europe are very promising. The dicentric assay in the web based scoring mode as a high throughput scoring strategy is a useful application for biodosimetry in the case of a large scale radiation accident.


Asunto(s)
Cromosomas Humanos/genética , Cromosomas Humanos/efectos de la radiación , Conducta Cooperativa , Internet , Liberación de Radiactividad Peligrosa , Radiometría/métodos , Triaje , Aberraciones Cromosómicas/efectos de la radiación , Humanos , Dosis de Radiación , Factores de Tiempo
19.
Behav Processes ; 100: 40-3, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23933377

RESUMEN

In a number of species, individuals showing lateralized hand/paw usage (i.e. the preferential use of either the right or left paw) compared to ambilateral individuals have been shown to be more proactive in novel situations. In the current study we used an established test to assess preferential paw usage in dogs (the Kong test) and then compared the performance of ambilateral and lateralized dogs as well as left- vs. right-pawed dogs in a novel manipulative problem solving task. Results showed an equal proportion of ambilateral and lateralized dogs but contrary to predictions non-lateralized dogs were faster at accessing the apparatus in test trials. No differences emerged between right- and left-pawed dogs. Results are discussed in relation to previous studies on lateralization.


Asunto(s)
Conducta Animal/fisiología , Lateralidad Funcional/fisiología , Solución de Problemas/fisiología , Desempeño Psicomotor/fisiología , Animales , Perros , Femenino , Masculino
20.
Radiat Res ; 180(2): 111-9, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23862692

RESUMEN

Rapid biodosimetry tools are required to assist with triage in the case of a large-scale radiation incident. Here, we aimed to determine the dose-assessment accuracy of the well-established dicentric chromosome assay (DCA) and cytokinesis-block micronucleus assay (CBMN) in comparison to the emerging γ-H2AX foci and gene expression assays for triage mode biodosimetry and radiation injury assessment. Coded blood samples exposed to 10 X-ray doses (240 kVp, 1 Gy/min) of up to 6.4 Gy were sent to participants for dose estimation. Report times were documented for each laboratory and assay. The mean absolute difference (MAD) of estimated doses relative to the true doses was calculated. We also merged doses into binary dose categories of clinical relevance and examined accuracy, sensitivity and specificity of the assays. Dose estimates were reported by the first laboratories within 0.3-0.4 days of receipt of samples for the γ-H2AX and gene expression assays compared to 2.4 and 4 days for the DCA and CBMN assays, respectively. Irrespective of the assay we found a 2.5-4-fold variation of interlaboratory accuracy per assay and lowest MAD values for the DCA assay (0.16 Gy) followed by CBMN (0.34 Gy), gene expression (0.34 Gy) and γ-H2AX (0.45 Gy) foci assay. Binary categories of dose estimates could be discriminated with equal efficiency for all assays, but at doses ≥1.5 Gy a 10% decrease in efficiency was observed for the foci assay, which was still comparable to the CBMN assay. In conclusion, the DCA has been confirmed as the gold standard biodosimetry method, but in situations where speed and throughput are more important than ultimate accuracy, the emerging rapid molecular assays have the potential to become useful triage tools.


Asunto(s)
Bioensayo/métodos , Cromosomas Humanos/efectos de la radiación , Roturas del ADN de Doble Cadena/efectos de la radiación , Histonas/metabolismo , Ensayos de Aptitud de Laboratorios , Leucocitos/efectos de la radiación , Pruebas de Micronúcleos , Radiometría/métodos , Adulto , Células Cultivadas/efectos de los fármacos , Células Cultivadas/efectos de la radiación , Aberraciones Cromosómicas , Citocinesis/efectos de la radiación , Relación Dosis-Respuesta en la Radiación , Expresión Génica/efectos de la radiación , Humanos , Leucocitos/ultraestructura , Masculino , Fosforilación , Procesamiento Proteico-Postraduccional , Traumatismos por Radiación/diagnóstico , Traumatismos por Radiación/genética , Liberación de Radiactividad Peligrosa , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Método Simple Ciego , Factores de Tiempo , Triaje/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...