Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Occup Environ Hyg ; 20(7): 289-303, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37084391

RESUMEN

The objective of this study is to evaluate a prototype local ventilation system (LVS) intended to reduce retail store workers' exposure to aerosols. The evaluation was carried out in a large aerosol test chamber where relatively uniform concentrations of polydisperse sodium chloride and glass-sphere particles were generated to test the system with nano- and micro-size particles. In addition, a cough simulator was constructed to mimic aerosols released by mouth breathing and coughing. Particle reduction efficiencies of the LVS were determined in four different experimental conditions using direct reading instruments and inhalable samplers. The particle reduction efficiency (%) depended on the position beneath the LVS, but the percentage was consistently high at the LVS center as follows: (1) > 98% particle reduction relative to background aerosols; (2) > 97% in the manikin's breathing zone relative to background aerosols; (3) > 97% during mouth breathing and coughing simulation; and (4) > 97% with a plexiglass barrier installation. Lower particle reduction (<70%) was observed when the LVS airflow was disturbed by background ventilation airflow. The lowest particle reduction (<20%) was observed when the manikin was closest to the simulator during coughing.


Asunto(s)
Exposición por Inhalación , Respiración por la Boca , Humanos , Tamaño de la Partícula , Aerosoles y Gotitas Respiratorias
2.
Aerosol Sci Technol ; 55(10): 1183-1201, 2021 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-35923215

RESUMEN

Aerosols emitted by the explosion of lithium-ion batteries were characterized to assess potential exposures. The explosions were initiated by activating thermal runaway in three commercial batteries: (1) lithium nickel manganese cobalt oxide (NMC), (2) lithiumiron phosphate (LFP), and (3) lithium titanate oxide (LTO). Post-explosion aerosols were collected on anodisc filters and analyzed by scanning electron microscopy (SEM) and energy-dispersive x-ray spectroscopy (EDS). The SEM and EDS analyses showed that aerosol morphologies and compositions were comparable to individual grains within the original battery materials for the NMC cell, which points to the fracture and ejection of the original battery components during the explosion. In contrast, the LFP cell emitted carbonaceous cenospheres, which suggests aerosol formation by the decomposition of organics within molten microspheres. LTO explosion aerosols showed characteristics of both types of emissions. The abundance of elements from the anode, cathode, and separator in respirable aerosols underscored the need for the selection of low-toxicity battery materials due to potential exposures in the event of battery thermal runaway.

3.
Arch Environ Occup Health ; 76(3): 134-144, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-32552564

RESUMEN

Respirable dust can pass beyond ciliated airways of the respiratory tract and influence adverse health effects. Health effects can be studied using samples generated from bulk dust segregation. Because previous segregation methods diverge from size-selection criteria of the international convention for respirable particles (ICRP), a method was developed to approximate the ICRP. The method was compared to an ideal sampler by measuring the sample collection bias. The comparison shows that the uncertainty due to the bias was 0.10 based on European Standard EN13205:2014 criteria, which indicates that the segregator effectively follows the ICRP. Respirable particle size distributions were confirmed by an aerodynamic particle sizer and by computer-controlled scanning electron microscopy. Consequently, a systematic way to generate respirable powders for health effects studies and chemical analyses was developed.


Asunto(s)
Contaminantes Atmosféricos/análisis , Polvo/análisis , Monitoreo del Ambiente/métodos , Exposición por Inhalación/análisis , Monitoreo del Ambiente/instrumentación , Monitoreo del Ambiente/normas , Humanos , Tamaño de la Partícula
4.
Int J Min Sci Technol ; 30(4): 449-454, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33598313

RESUMEN

Researchers from the National Institute for Occupational Safety and Health (NIOSH) conducted a study in an isolated zone of an underground mine to characterize aerosols generated by: (1) a diesel-powered personnel carrier vehicle operated over a simulated light-duty cycle and (2) the simulated repair of existing equipment using manual metal arc welding (MMAW). Both the diesel-powered vehicle and MMAW process contributed to concentrations of nano and ultrafine aerosols in the mine air. The welding process also contributed to aerosols with electrical mobility and aerodynamic mobility count median diameters of approximately 140 and 480 nm, respectively. The welding particles collected on the filters contained carbon, iron, manganese, calcium, and aluminum.

5.
J Occup Environ Hyg ; 14(5): 323-334, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-27792474

RESUMEN

Airborne coal dust generated during mining can deposit and accumulate on mine surfaces, presenting a dust explosion hazard. When assessing dust hazard mitigation strategies for airborne dust reduction, sampling is done in high-velocity ventilation air, which is used to purge the mining face and gallery tunnel. In this environment, the sampler inlet velocity should be matched to the air stream velocity (isokinetic sampling) to prevent oversampling of coarse dust at low sampler-to-air velocity ratios. Low velocity ratios are often encountered when using low flow rate, personal sampling pumps commonly used in underground mines. In this study, with a goal of employing mine-ready equipment, a personal sampler was adapted for area sampling of coarse coal dust in high-velocity ventilation air. This was done by adapting an isokinetic nozzle to the inlet of an Institute of Occupational Medicine (Edinburgh, Scotland) sampling cassette (IOM). Collected dust masses were compared for the modified IOM isokinetic sampler (IOM-MOD), the IOM without the isokinetic nozzle, and a conventional dust sampling cassette without the cyclone on the inlet. All samplers were operated at a flow rate typical of personal sampling pumps: 2 L/min. To ensure differences between collected masses that could be attributed to sampler design and were not influenced by artifacts from dust concentration gradients, relatively uniform and repeatable dust concentrations were demonstrated in the sampling zone of the National Institute for Occupational Safety and Health experimental mine gallery. Consistent with isokinetic theory, greater differences between isokinetic and non-isokinetic sampled masses were found for larger dust volume-size distributions and higher ventilation air velocities. Since isokinetic sampling is conventionally used to determine total dust concentration, and isokinetic sampling made a difference in collected masses, the results suggest when sampling for coarse coal dust the IOM-MOD may improve airborne coarse dust assessments over "off-the-shelf" sampling cassettes.


Asunto(s)
Minas de Carbón , Carbón Mineral/análisis , Polvo/análisis , Monitoreo del Ambiente/métodos , Salud Laboral , Diseño de Equipo , Explosiones/prevención & control , Humanos , Tamaño de la Partícula , Ventilación
6.
Aerosol Sci Technol ; 46(12): 1370-1381, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26361400

RESUMEN

The extensive use of diesel-powered equipment in mines makes the exposure to diesel aerosols a serious occupational issue. The exposure metric currently used in U.S. underground noncoal mines is based on the measurement of total carbon (TC) and elemental carbon (EC) mass concentration in the air. Recent toxicological evidence suggests that the measurement of mass concentration is not sufficient to correlate ultrafine aerosol exposure with health effects. This urges the evaluation of alternative measurements. In this study, the current exposure metric and two additional metrics, the surface area and the total number concentration, were evaluated by conducting simultaneous measurements of diesel ultrafine aerosols in a laboratory setting. The results showed that the surface area and total number concentration of the particles per unit of mass varied substantially with the engine operating condition. The specific surface area (SSA) and specific number concentration (SNC) normalized with TC varied two and five times, respectively. This implies that miners, whose exposure is measured only as TC, might be exposed to an unknown variable number concentration of diesel particles and commensurate particle surface area. Taken separately, mass, surface area, and number concentration did not completely characterize the aerosols. A comprehensive assessment of diesel aerosol exposure should include all of these elements, but the use of laboratory instruments in underground mines is generally impracticable. The article proposes a new approach to solve this problem. Using SSA and SNC calculated from field-type measurements, the evaluation of additional physical properties can be obtained by using the proposed approach.

7.
J Air Waste Manag Assoc ; 60(8): 968-76, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20842937

RESUMEN

A field-aged, passive diesel particulate filter (DPF) used in a school bus retrofit program was evaluated for emissions of particle mass and number concentration before, during, and after regeneration. For the particle mass measurements, filter samples were collected for gravimetric analysis with a partial flow sampling system, which sampled proportionally to the exhaust flow. A condensation particle counter and scanning mobility particle sizer measured total number concentration and number-size distributions, respectively. The results of the evaluation show that the number concentration emissions decreased as the DPF became loaded with soot. However, after soot removal by regeneration, the number concentration emissions were approximately 20 times greater, which suggests the importance of the soot layer in helping to trap particles. Contrary to the number concentration results, particle mass emissions decreased from 6 +/- 1 mg/hp-hr before regeneration to 3 +/- 2 mg/hp-hr after regeneration. This indicates that nanoparticles with diameters less than 50 nm may have been emitted after regeneration because these particles contribute little to the total mass. Overall, average particle emission reductions of 95% by mass and 10,000-fold by number concentration after 4 yr of use provided evidence of the durability of a field-aged DPF. In contrast to previous reports for new DPFs in which elevated number concentrations occurred during the first 200 sec of a transient cycle, the number concentration emissions were elevated during the second half of the heavy-duty Federal Test Procedure (FTP) when high speed was sustained. This information is relevant for the analysis of mechanisms by which particles are emitted from field-aged DPFs.


Asunto(s)
Contaminantes Ocupacionales del Aire/química , Material Particulado/química , Emisiones de Vehículos/análisis , Contaminación del Aire/prevención & control , Monitoreo del Ambiente/métodos , Filtración , Gasolina , Tamaño de la Partícula , Presión , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...