Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Brain Sci ; 12(9)2022 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-36138994

RESUMEN

A comparative single-evaluation cross-sectional study was performed to evaluate cognitive damage in post-COVID-19 patients. The psychophysics tests of Two-Alternative Forced Choice (2AFC) and Simple Reaction Time (SRT), under a designed virtual environment, were used to evaluate the cognitive processes of decision-making, visual attention, and information processing speed. The population under study consisted of 147 individuals, 38 controls, and 109 post-COVID patients. During the 2AFC test, an Emotiv EPOC+® headset was used to obtain EEG signals to evaluate their Focus, Interest, and Engagement metrics. Results indicate that compared to healthy patients or recovered patients from mild-moderate COVID-19 infection, patients who recovered from a severe-critical COVID infection showed a poor performance in different cognitive tests: decision-making tasks required higher visual sensitivity (p = 0.002), Focus (p = 0.01) and information processing speed (p < 0.001). These results signal that the damage caused by the coronavirus on the central nervous and visual systems significantly reduces the cognitive processes capabilities, resulting in a prevalent deficit of 42.42% in information processing speed for mild-moderate cases, 46.15% for decision-making based on visual sensitivity, and 62.16% in information processing speed for severe-critical cases. A psychological follow-up for patients recovering from COVID-19 is recommended based on our findings.

2.
Sensors (Basel) ; 22(15)2022 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-35957199

RESUMEN

The inclusion of the Internet of Things (IoT) in greenhouses has become a fundamental tool for improving cultivation systems, offering information relevant to the greenhouse manager for decision making in search of optimum yield. This article presents a monitoring system applied to an aeroponic greenhouse based on an IoT architecture that provides user information on the status of the climatic variables and the appearance of the crop in addition to managing the irrigation timing and the frequency of visual inspection using an application developed for Android mobile devices called Aeroponics Monitor. The proposed IoT architecture consists of four layers: a device layer, fog layer, cloud layer and application layer. Once the information about the monitored variables is obtained by the sensors of the device layer, the fog layer processes it and transfers it to the Thingspeak and Firebase servers. In the cloud layer, Thingspeak analyzes the information from the variables monitored in the greenhouse through its IoT analytic tools to generate historical data and visualizations of their behavior, as well as an analysis of the system's operating status. Firebase, on the other hand, is used as a database to store the results of the processing of the images taken in the fog layer for the supervision of the leaves and roots. The results of the analysis of the information of the monitored variables and of the processing of the images are presented in the developed app, with the objective of visualizing the state of the crop and to know the function of the monitoring system in the event of a possible lack of electricity or a service line failure in the fog layer and to avoid the loss of information. With the information about the temperature of the plant leaf and the relative humidity inside the greenhouse, the vapor pressure deficit (VPD) in the cloud layer is calculated; the VPD values are available on the Thingspeak server and in the developed app. Additionally, an analysis of the VPD is presented that demonstrates a water deficiency from the transplanting of the seedling to the cultivation chamber. The IoT architecture presented in this paper represents a potential tool for the study of aeroponic farming systems through IoT-assisted monitoring.


Asunto(s)
Agricultura , Atención a la Salud , Monitoreo Fisiológico , Presión de Vapor
3.
Sensors (Basel) ; 22(7)2022 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-35408360

RESUMEN

(1) Background: As breast cancer studies suggest, a high percentage of breast density (PBD) may be related to breast cancer incidence. Although PBD screening is one of the strongest predictors of breast cancer risk, X-ray-based mammography evaluation is subjective. Therefore, new objective PBD measuring techniques are of interest. A case study analyzing the PBD of thirteen female participants using a bioimpedance-based method, the anomalies tracking circle (ATC), is described in this paper. (2) Methods: In the first stage, the breast bioimpedance of each participant was measured. Then, the participant breast density was determined by applying a mammogram just after the breast bioimpedance measurement stage. In the third stage, the ATC algorithm was applied to the measured bioimpedance data for each participant, and a results analysis was done. (3) Results: An ATC variation according to the breast density was observed from the obtained data, this allowed the use of classification techniques to determine the PBD. (4) Conclusions: The described breast density method is a promising approach that might be applied as an auxiliary tool to the mammography in order to obtain precise and objective results for evaluation of breast density and with that determine potential breast cancer risk.


Asunto(s)
Densidad de la Mama , Neoplasias de la Mama , Algoritmos , Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Humanos , Mamografía/métodos
4.
Sensors (Basel) ; 22(6)2022 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-35336429

RESUMEN

The interruption of rehabilitation activities caused by the COVID-19 lockdown has significant health negative consequences for the population with physical disabilities. Thus, measuring the range of motion (ROM) using remotely taken photographs, which are then sent to specialists for formal assessment, has been recommended. Currently, low-cost Kinect motion capture sensors with a natural user interface are the most feasible implementations for upper limb motion analysis. An active range of motion (AROM) measuring system based on a Kinect v2 sensor for upper limb motion analysis using Fugl-Meyer Assessment (FMA) scoring is described in this paper. Two test groups of children, each having eighteen participants, were analyzed in the experimental stage, where upper limbs' AROM and motor performance were assessed using FMA. Participants in the control group (mean age of 7.83 ± 2.54 years) had no cognitive impairment or upper limb musculoskeletal problems. The study test group comprised children aged 8.28 ± 2.32 years with spastic hemiparesis. A total of 30 samples of elbow flexion and 30 samples of shoulder abduction of both limbs for each participant were analyzed using the Kinect v2 sensor at 30 Hz. In both upper limbs, no significant differences (p < 0.05) in the measured angles and FMA assessments were observed between those obtained using the described Kinect v2-based system and those obtained directly using a universal goniometer. The measurement error achieved by the proposed system was less than ±1° compared to the specialist's measurements. According to the obtained results, the developed measuring system is a good alternative and an effective tool for FMA assessment of AROM and motor performance of upper limbs, while avoiding direct contact in both healthy children and children with spastic hemiparesis.


Asunto(s)
COVID-19 , COVID-19/diagnóstico , Niño , Preescolar , Control de Enfermedades Transmisibles , Hemiplejía , Humanos , Rango del Movimiento Articular , Extremidad Superior
5.
Sensors (Basel) ; 21(23)2021 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-34883885

RESUMEN

Quantifying the quality of upper limb movements is fundamental to the therapeutic process of patients with cerebral palsy (CP). Several clinical methods are currently available to assess the upper limb range of motion (ROM) in children with CP. This paper focuses on identifying and describing available techniques for the quantitative assessment of the upper limb active range of motion (AROM) and kinematics in children with CP. Following the screening and exclusion of articles that did not meet the selection criteria, we analyzed 14 studies involving objective upper extremity assessments of the AROM and kinematics using optoelectronic devices, wearable sensors, and low-cost Kinect sensors in children with CP aged 4-18 years. An increase in the motor function of the upper extremity and an improvement in most of the daily tasks reviewed were reported. In the population of this study, the potential of wearable sensors and the Kinect sensor natural user interface as complementary devices for the quantitative evaluation of the upper extremity was evident. The Kinect sensor is a clinical assessment tool with a unique markerless motion capture system. Few authors had described the kinematic models and algorithms used to estimate their kinematic analysis in detail. However, the kinematic models in these studies varied from 4 to 10 segments. In addition, few authors had followed the joint assessment recommendations proposed by the International Society of Biomechanics (ISB). This review showed that three-dimensional analysis systems were used primarily for monitoring and evaluating spatiotemporal variables and kinematic parameters of upper limb movements. The results indicated that optoelectronic devices were the most commonly used systems. The joint assessment recommendations proposed by the ISB should be used because they are approved standards for human kinematic assessments. This review was registered in the PROSPERO database (CRD42021257211).


Asunto(s)
Parálisis Cerebral , Fenómenos Biomecánicos , Parálisis Cerebral/diagnóstico , Niño , Humanos , Movimiento , Rango del Movimiento Articular , Extremidad Superior
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA