RESUMEN
BACKGROUND: Spatiotemporal dispersion-guided ablation is a tailored approach for patients in persistent atrial fibrillation (PsAF). The characterization of dispersion extent and distribution and its association with common clinical descriptors of PsAF patients has not been studied. OBJECTIVES: Artificial intelligence-adjudicated dispersion extent and distribution (AI-DED) was obtained with a machine/deep learning classifier (VX1 Software, Volta Medical) in PsAF patients undergoing ablation. The purpose of this study was to test the hypothesis that AI-DED is unique to each patient and independent of common procedural and clinical parameters. METHODS: In a subanalysis of the Ev-AIFib study (NCT03434964), spatiotemporal dispersion maps were built with VX1 software in 78 consecutive persistent and long-standing PsAF patients. AI-DED was quantified using 2 distinct approaches (visual regional characterization or automated global quantification of AI-DED). RESULTS: AI-DED paired-subregion Euclidean distance measurements between 78 patients (average distance 5.07 ± 0.60; min 2.23; max 9.75) demonstrate that AI-DED is a patient-unique characteristic of PsAF. Importantly, both AF type and AF history do not correlate with AI-DED levels (R2 = 0.006, P = .53; and R2 = 0.03, P = .25, respectively). The most extensive AI-DED levels are not associated with poorer procedural (83%, 81%, and 83% of AF termination in low, medium, and high dispersion groups, respectively; P = .954) and long-term (88%, 75%, and 91% of freedom from AF/atrial tachycardia after multiple procedures; P = .517) outcomes. CONCLUSION: The atrial distribution and extent of multipolar electrogram spatiotemporal dispersion follow a nonrandom, albeit patient-unique, distribution in PsAF patients. AI-DED may represent a procedure-implementable fingerprint of the PsAF substrate.
Asunto(s)
Inteligencia Artificial , Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico , Femenino , Masculino , Persona de Mediana Edad , Ablación por Catéter/métodos , Anciano , Sistema de Conducción Cardíaco/fisiopatología , Electrocardiografía , Estudios de SeguimientoRESUMEN
BACKGROUND: Recurrences of atrial fibrillation (AF) after pulmonary vein isolation (PVI) are mainly due to pulmonary vein reconnection. However, a growing number of patients have AF recurrences despite durable PVI. The optimal ablative strategy for these patients is unknown. We analyzed the impact of current ablation strategies in a large multicenter study. METHODS: Patients undergoing a redo ablation for AF and presenting durable PVI were included. The freedom from atrial arrhythmia after pulmonary vein-based, linear-based, electrogram-based, and trigger-based ablation strategies were compared. RESULTS: Between 2010 and 2020, 367 patients (67% men, 63±10 years, 44% paroxysmal) underwent a redo ablation for AF recurrences despite durable PVI at 39 centers. After durable PVI was confirmed, linear-based ablation was performed in 219 (60%) patients, electrogram-based ablation in 168 (45%) patients, trigger-based ablation in 101 (27%) patients, and pulmonary vein-based ablation in 56 (15%) patients. Seven patients (2%) did not undergo any additional ablation during the redo procedure. After 22±19 months of follow-up, 122 (33%) and 159 (43%) patients had a recurrence of atrial arrhythmia at 12 and 24 months, respectively. No significant difference in arrhythmia-free survival was observed between the different ablation strategies. Left atrial dilatation was the only independent factor associated with arrhythmia-free survival (HR, 1.59 [95% CI, 1.13-2.23]; P=0.006). CONCLUSIONS: In patients with recurrent AF despite durable PVI, no ablation strategy used alone or in combination during the redo procedure appears to be superior in improving arrhythmia-free survival. Left atrial size is a significant predictor of ablation outcome in this population.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Masculino , Humanos , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Atrios Cardíacos , Reoperación/métodos , Recurrencia , Resultado del TratamientoRESUMEN
Background: The role of atrial fibrillation (AF) drivers located at the left atrium, superior vena cava, crista terminalis and coronary sinus (CS) is well established. While these regions are classically targeted during catheter ablation, the role of right atrial appendage (RAA) drivers has been incompletely investigated. Objective: To determine the prevalence and electrophysiological characteristics of AF driver's arising from the RAA. Materials and methods: We conducted a retrospective analysis of clinical and procedural data of 317 consecutive patients who underwent an AF ablation procedure after bi-atrial mapping (multipolar catheter). We selected patients who presented with a per-procedural RAA firing (RAAF). RAAF was defined as the recording of a sustained RAA EGM with a cycle length shorter than 120 ms or 120 < RAAF CL ≤ 130 ms and ratio RAA CL/CS CL ≤ 0.75. Results: Right atrial/atrium appendage firing was found in 22 patients. The prevalence was estimated at 7% (95% CI, 4-10). These patients were mostly men (72%), median age: 66 yo ± 8 without structural heart disease (77%). RAAFs were predominantly found in paroxysmal AF patients (63%, 32%, and 5% for paroxysmal, short standing and long-standing AF, respectively, p > 0.05). RAAF median cycle length was 117 ms ± 7 while CS cycle length was 180 ms ± 10 (p < 0.01). Conclusion: In 317 consecutive AF ablation patients (22 patients, 7%) the presence of a high-voltage short-cycle-length right atrial appendage driver (RAAF) may conclusively be associated with AF termination. This case series exemplifies the not-so-uncommon role of the RAA in the perpetuation of AF.
RESUMEN
INTRODUCTION: Multiple groups have reported on the usefulness of ablating in atrial regions exhibiting abnormal electrograms during atrial fibrillation (AF). Still, previous studies have suggested that ablation outcomes are highly operator- and center-dependent. This study sought to evaluate a novel machine learning software algorithm named VX1 (Volta Medical), trained to adjudicate multipolar electrogram dispersion. METHODS: This study was a prospective, multicentric, nonrandomized study conducted to assess the feasibility of generating VX1 dispersion maps. In 85 patients, 8 centers, and 17 operators, we compared the acute and long-term outcomes after ablation in regions exhibiting dispersion between primary and satellite centers. We also compared outcomes to a control group in which dispersion-guided ablation was performed visually by trained operators. RESULTS: The study population included 29% of long-standing persistent AF. AF termination occurred in 92% and 83% of the patients in primary and satellite centers, respectively, p = 0.31. The average rate of freedom from documented AF, with or without antiarrhythmic drugs (AADs), was 86% after a single procedure, and 89% after an average of 1.3 procedures per patient (p = 0.4). The rate of freedom from any documented atrial arrhythmia, with or without AADs, was 54% and 73% after a single or an average of 1.3 procedures per patient, respectively (p < 0.001). No statistically significant differences between outcomes of the primary versus satellite centers were observed for one (p = 0.8) or multiple procedures (p = 0.4), or between outcomes of the entire study population versus the control group (p > 0.2). Interestingly, intraprocedural AF termination and type of recurrent arrhythmia (i.e., AF vs. AT) appear to be predictors of the subsequent clinical course. CONCLUSION: VX1, an expertise-based artificial intelligence software solution, allowed for robust center-to-center standardization of acute and long-term ablation outcomes after electrogram-based ablation.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/tratamiento farmacológico , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Estudios Prospectivos , Inteligencia Artificial , Resultado del Tratamiento , Antiarrítmicos/uso terapéutico , Programas Informáticos , Venas Pulmonares/cirugía , RecurrenciaRESUMEN
INTRODUCTION: During atrial fibrillation (AF) ablation, it is generally considered that atrial tachycardia (AT) episodes are a consequence of ablation. Objective: To investigate the spatial relationship between localized AT episodes and dispersion/ablation regions during persistent AF ablation procedures. Methods: We analyzed 72 consecutive patients who presented for an index persistent AF ablation procedure guided by the presence of spatiotemporal dispersion of multipolar electrograms. We characterized spontaneous or post-ablation ATs' mechanism and location in regard to dispersion regions and ablation lesions. RESULTS: In 72 consecutive patients admitted for persistent AF ablation, 128 ATs occurred in 62 patients (1.9 ± 1.1/patient). Seventeen ATs were recorded before any ablation. In a total of 100 ATs with elucidated mechanism, there were 58 localized sources and 42 macro-reentries. A large number of localized ATs arose from regions exhibiting dispersion during AF (n = 49, 84%). Importantly, these ATs' locations were generally remote from the closest ablation lesion (n = 42, 72%). CONCLUSIONS: In patients undergoing a persistent AF ablation procedure guided by the presence of spatiotemporal dispersion of multipolar electrograms, localized ATs originate within dispersion regions but remotely from the closest ablation lesion. These results suggest that ATs represent a stabilized manifestation of co-existing AF drivers rather than ablation-induced arrhythmias.
RESUMEN
BACKGROUND: Atrial fibrillation (AF) is associated with increased risk of stroke, heart failure and all-cause mortality. The Cox-Maze procedure is the most effective approach to ablate persistent AF but presents a significant morbidity and mortality. Additionally, the classical endocardial ablation approach has limited efficacy to treat long lasting persistent AF. We described a new, minimally invasive hybrid approach, combining an endocardial and epicardial ablation named convergent procedure to treat long lasting persistent AF patients. METHODS: We studied 55 consecutive patients with long lasting persistent AF who underwent the convergent procedure in 2 French centers between 2010 and 2015. All patients had at least one previous failed endocardial ablation and were highly symptomatic. Patients with a history of thoracic surgery were excluded. A 24 hour-Holter ECG was performed systematically at 3, 6 and 12 months after the convergent procedure. All patients reached 1-year follow-up. RESULTS: No death, stroke, phrenic nerve palsy or tamponade occurred immediately after the procedure. Post-surgery average length of stay was 8±4 days. Later, 3 patients (5%) developed diaphragmatic hernia resulting in a modified surgery technique. At 12 months, 76% of patients were in sinus rhythm after an average of 1.43 ablation procedure. Finally, 91% of patients were maintained on antiarrhythmic drugs. CONCLUSIONS: Thoracoscopic hybrid epicardial-endocardial ablation technique proved to be effective and safe to treat long lasting persistent AF patients with previous failed endocardial AF ablation.
Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Toracoscopía , Anciano , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Femenino , Francia , Humanos , Masculino , Persona de Mediana Edad , Supervivencia sin Progresión , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Toracoscopía/efectos adversos , Factores de TiempoAsunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Ablación por Catéter/tendencias , Difusión de Innovaciones , Medicina Basada en la Evidencia , Humanos , Venas Pulmonares/fisiopatología , Resultado del TratamientoRESUMEN
BACKGROUND: The use of intracardiac electrograms to guide atrial fibrillation (AF) ablation has yielded conflicting results. OBJECTIVES: The authors evaluated the usefulness of spatiotemporal dispersion, a visually recognizable electric footprint of AF drivers, for the ablation of all forms of AF. METHODS: The authors prospectively enrolled 105 patients admitted for AF ablation. AF was sequentially mapped in both atria with a 20-pole PentaRay catheter. The authors tagged and ablated only regions displaying electrogram dispersion during AF. Results were compared to a validation set in which a conventional ablation approach was used (pulmonary vein isolation/stepwise approach). To establish the mechanism underlying spatiotemporal dispersion of AF electrograms, the authors conducted realistic numerical simulations of AF drivers in a 2-dimensional model and optical mapping of ovine atrial scar-related AF. RESULTS: Ablation at dispersion areas terminated AF in 95% of the 105 patients. After ablation of 17 ± 10% of the left atrial surface and 18 months of follow-up, the atrial arrhythmia recurrence rate was 15% after 1.4 ± 0.5 procedures per patient versus 41% in the validation set after 1.5 ± 0.5 procedures per patient (arrhythmia free-survival: 85% vs. 59%; log-rank p < 0.001). Compared with the validation set, radiofrequency times (49 ± 21 min vs. 85 ± 34.5 min; p = 0.001) and procedure times (168 ± 42 min vs. 230 ± 67 min; p < 0.0001) were shorter. In simulations and optical mapping experiments, virtual PentaRay recordings demonstrated that electrogram dispersion is mostly recorded in the vicinity of a driver. CONCLUSIONS: The clustering of intracardiac electrograms exhibiting spatiotemporal dispersion is indicative of AF drivers. Their ablation allows for a nonextensive and patient-tailored approach to AF ablation. (Substrate Ablation Guided by High Density Mapping in Atrial Fibrillation [SUBSTRATE HD]; NCT02093949).
Asunto(s)
Técnicas de Ablación/métodos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Electrocardiografía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , RecurrenciaRESUMEN
OBJECTIVES: This study sought to evaluate the impact of a complex fractionated atrial electrogram (CFAE)-guided ablation strategy on atrial fibrillation (AF) dynamics in patients with persistent AF. BACKGROUND: It is still unclear whether complete pulmonary vein isolation (PVI) is required or if the ablation of well-delineated pulmonary vein (PV) subregions could achieve similar outcomes in persistent AF. METHODS: CFAE-guided ablations were performed in 76 patients (65.2 ± 10 years of age) with persistent AF. In 47 patients, we measured mean PVs and left atrial appendage (LAA) cycle length (CL) values (PV-CL and LAA-CL), before ablation and before AF termination. We defined "active" PVs as PV-CL ≤ LAA-CL, "rapid fires" as PV-CL ≤80% of LAA-CL, and "PV-LAA CL gradient" as a significant CL difference between the 2 regions. RESULTS: AF termination (sinus rhythm [SR] or atrial tachycardia [AT] conversion) occurred in 92% and SR conversion in 75%. The radiofrequency time for AF termination and total radiofrequency time were 26 ± 25 min and 61.1 ± 21.6 min, respectively. Thirty of 47 patients had active PV (with 19 PV "rapid fires"). Ablation significantly increased median CL, both at PVs and LAA from 188 ms (interquartile range [IQR]: 161 to 210 ms) to 227.5 ms (IQR: 200 to 256 ms) (p < 0.0001) and from 197 ms (IQR: 168 to 220 ms) to 224 ms (IQR: 193 to 250 ms) (p < 0001), respectively. After ablation, PV-LAA CL gradients were withdrawn and all PV "rapid fires" were extinguished (without PVI). After 17.2 ± 10 months of follow-up and 1.61 ± 0.75 procedures, 86.3% and 73% of the patients were free from AF and from any arrhythmia (AF/AT), respectively. CONCLUSIONS: CFAE-guided ablation leads to a large decrease in PV frequency of activation, preceding AF termination. A PV modulation approach, rather than complete PVI, may be preferable for persistent AF.
RESUMEN
BACKGROUND: The objective of this collaborative, multicenter, European effort was to evaluate the outcomes of the convergent procedure for the treatment of persistent and long-standing persistent atrial fibrillation (AF) in consecutive patients at 4 European centers. METHODS: Outcomes of consecutive patients, undergoing the convergent procedure at 4 European centers, were evaluated in this study. Epicardial ablation was performed before endocardial ablation. Convergent procedure outcomes were recorded by interrogation of implanted loop recorders or Holter monitors. Rhythm status and required interventions (antiarrhythmic drugs, cardioversions, and repeat ablations) were quantified 6 and 12 months after the procedure. Outcomes, monitoring type, and patient baseline characteristics were analyzed and reported. RESULTS: Seventy-three consecutive patients presenting with persistent AF (30.1%) or long-standing persistent AF (69.9%) underwent the convergent procedure between January 2010 and December 2011. At 6 months, 82% (56/68) were in sinus rhythm. At 12 months, 80% (53/66) were in sinus rhythm; single-procedure maintenance of sinus rhythm without postblanking period interventions was 76% (50/66); 52% (34/66) were in sinus rhythm and not receiving antiarrhythmic drugs. CONCLUSIONS: This multicenter European collaborative effort demonstrated that the convergent procedure is a safe and efficacious treatment option for persistent and long-standing persistent AF.
Asunto(s)
Fibrilación Atrial/cirugía , Adulto , Anciano , Procedimientos Quirúrgicos Cardíacos/métodos , Europa (Continente) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del TratamientoRESUMEN
AIMS: To assess whether response to cardiac resynchronization therapy (CRT) is related to myocardial viability in the paced left ventricular (LV) region, evaluated by contractile reserve (CR). Non-response to CRT may partly be due to inefficient pacing by the LV lead located in a fibrotic area. METHODS AND RESULTS: Nineteen patients (64 +/- 13 years, 14 men, 9 ischaemic) with severe heart failure (EF = 27 +/- 8%, QRS = 154 +/- 25 ms) were included in the week after device implantation. Stroke volume (SV) and LV dyssynchrony (by Tissue Doppler Imaging) were successively assessed with CRT on and CRT off. Afterwards, CRT device was maintained off during dobutamine infusion to assess CR in the LV-pacing region. LV end-systolic volume (ESV) was assessed after 6 months to quantify reverse remodelling. CR in the paced LV region (n = 10, 5/9 ischaemic and 5/10 non-ischaemic) was correlated to a reduction in LV dyssynchrony under CRT (120 +/- 76 vs. 78 +/- 64 ms, P = 0.02). Conversely, LV dyssynchrony was unchanged (161 +/- 100 vs. 163 +/- 80 ms) without CR. In desynchronized patients (>65 ms, n = 15), increase in SV under CRT and changes in ESV at 6 months were +22 and -18%, respectively, when CR was present and 0% and +9%, respectively, when absent. CONCLUSION: Acute haemodynamic response and reverse remodelling under CRT require viability in the target region of LV lead.