Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Sex Med ; 12(2): qfae018, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38560649

RESUMEN

Background: Selective androgen receptor modulators (SARMs) are small synthetic drug molecules that are still not approved as medicine in Europe or the United States but are sold on illegal websites to improve sport performance, particularly bodybuilding. Aim: To address the quality issues of illegal SARM products and their increasing diffusion in Italy with their potential health risks for consumers. Methods: Web-based tools were used to investigate retail websites, trending searches, and information exchange via social media. Thirteen SARM products, purchased on retail websites accessible from Italy, were subject to visual inspection and chemical analysis by mass spectrometry and quantitative nuclear magnetic resonance. Outcomes: The primary outcome was demonstration of additional health risks due to the illicit presence of other active ingredients, contamination, and misdosage in SARM products sold on the internet. The secondary outcome was to show the increasing trend of interest in Italy for these products. Results: Most websites reported misleading information; specifically, the statement "for research only" was reported notwithstanding indications on dosage and training phases. The trending search showed that interest toward SARMs increased in Italy in the last years. The use of these products is clearly encouraged by the emerging phenomenon of "broscience" as revealed in socials. Visual inspection evidenced nonconform labeling. Qualitative analysis confirmed the presence of the stated SARM in about 70% of samples. In 23% of samples, the expected SARM was not detected but a different one instead, and in 1 sample, no SARMs were detected. Other undeclared pharmaceutical substances (tamoxifen, clomifene, testosterone, epimethandienone, tadalafil) were measured in 30% of samples. The copresence of >1 active substance was observed in >60% of samples. Quantitative nuclear magnetic resonance data showed nonuniform content ranging from 30% to 90% of the label claim. Clinical Implications: The use of SARMs, in the presence of unexpected life-threatening reactions in persons using the products to increase sport performance, should be assessed. Strengths and Limitations: This investigation involved an integrated approach to study SARM products and related sociologic aspects. The main shortcomings are the limited number of samples and retail websites in the clear web investigated. Conclusion: SARMs sold online as food supplement-like products represent a health hazard due to the presence of unapproved and undeclared active substances. The presence of contaminants clearly indicates the absence of good manufacturing practices in the production, which increases the health risks.

2.
Ann Ist Super Sanita ; 58(4): 254-263, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36511196

RESUMEN

INTRODUCTION: A case study is reported on anti-motion sickness transdermal patches sold in the Internet, claiming to contain only natural ingredients but, actually, containing undeclared medicinal active substances. The visual inspection of the samples evidenced many inconsistencies in secondary and primary packaging, missing of various legal information and a non-compliant "CE" mark. METHODS: The qualitative analysis was performed by liquid chromatography - high resolution mass spectrometry and the quantitative by liquid chromatography with diode array detector. RESULTS: The analyses evidenced the presence of the antihistaminic drug Diphenhydramine and of other active substances (Capsaicin, a transdermal absorption enhancer, and Diclofenac in traces, probably a contaminant from other productions of the same plant). Moreover, the presence of several trace elements, including those potentially toxic to humans, was assessed by ICP-MS analysis. CONCLUSIONS: The case discussed is a new case of "medicines in disguise" never reported in literature, and shows the presence of tangible risks for public health.


Asunto(s)
Preparaciones Farmacéuticas , Humanos
3.
Ann Ist Super Sanita ; 56(4): 403-408, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33346165

RESUMEN

INTRODUCTION: Ibuprofen is one of the widespread used non-steroidal anti-inflammatory drugs. Ibuprofen active ingredient is manufactured in many sites located all around the world. The aim of this paper was to classify the geographical source of ibuprofen active pharmaceutical ingredients (APIs) from the legal market, based on chemical characteristics and its impurity pattern and to define a geographical fingerprint. METHODS: To classify ibuprofen in different geographical groups, the chemometrics by principal component analysis (PCA) and Cluster analysis was applied to HPLC, 1H-NMR data of twenty-four samples of APIs from approved manufacturers located in different European and Asian countries. RESULTS: The PCA showed clearly two different geographical groups, based on particular patterns of European or Indian samples; the cluster analysis showed the similarity of group. CONCLUSION: The chemometric analysis is an important tool for tracking the geographical origin of APIs. This could be useful to supplement the quality control ensuring safety of the medicinal products in legal market and dealing with the evolving changes of the illegal market.


Asunto(s)
Antiinflamatorios no Esteroideos/química , Antiinflamatorios no Esteroideos/clasificación , Cromatografía Líquida de Alta Presión , Ibuprofeno/química , Ibuprofeno/clasificación , Espectroscopía de Protones por Resonancia Magnética , Análisis por Conglomerados , Industria Farmacéutica/legislación & jurisprudencia , Italia , Análisis de Componente Principal
4.
Talanta ; 198: 337-343, 2019 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-30876570

RESUMEN

This paper describes a case of medicine in disguise: seized tattoo inks containing lidocaine and tetracaine at high concentration. Identification of anaesthetics was performed by LC MS Q-TOF with ESI+ source, by accurate mass measurement and by comparing the fragmentation patterns of molecular ions, at 30 V and 10 V of collision-offset voltage, with reference standards. Quantification was also performed by LC MS Q-TOF on the chromatographic peaks in the extracted ion chromatograms, by calibration curves obtained at different standard concentrations and by standard additions approach. The measurement uncertainty was estimated from validation data. The paper gives also chromatographic parameters, MS and MS/MS data and a quantitation method, with a full validation, of other six "caines". Thus the paper intends to provide a tool for identification and quantitation of the most common local anaesthetics that could be fraudulently added to tattoo inks. The results here reported show that the seized samples of inks represent a serious health risk owing to the high anaesthetic content - therapeutic-like dosage - found.


Asunto(s)
Anestésicos/análisis , Tinta , Lidocaína/análisis , Tatuaje , Tetracaína/análisis , Cromatografía Liquida , Humanos , Espectrometría de Masas
5.
Ann Ist Super Sanita ; 52(1): 128-32, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27033629

RESUMEN

OBJECTIVES: The increasing illegal and on-line market of medicines and food supplements is helping the widespread diffusion of harmful counterfeit and forbidden products among consumers of developed countries. The objectives of this survey were the description of the main frauds recognized by public officers and the detection of illegal or counterfeit drugs and food supplements. METHODS: Medicines and food supplements found by Police forces on the illegal market or resulting from seizures made by Italian Customs authorities were visually inspected and analysed to evaluate their quality and the presence of other undeclared substances. RESULTS: The visual inspection and the chemical analysis revealed unsuitable packaging (mostly lacking of adequate information for consumers), absence of the declared active substances and presence of undeclared active substances. Products containing doping agents, illegal substances and active ingredients requiring medical supervision were found. CONCLUSION: The present work confirmed the health risk associated with assumption of medicines purchased on the Internet and from the illegal supply chain and evidenced a new threat to consumer safety related to the presence of pharmaceutical active ingredients in food supplements claiming to contain only "natural ingredients".


Asunto(s)
Medicamentos Falsificados , Suplementos Dietéticos , Tráfico de Drogas , Drogas Ilícitas/efectos adversos , Internet , Seguridad de Productos para el Consumidor , Etiquetado de Medicamentos , Humanos , Italia , Preparaciones Farmacéuticas/análisis , Medición de Riesgo , Encuestas y Cuestionarios
6.
J Pharm Biomed Anal ; 96: 170-86, 2014 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-24747148

RESUMEN

Novel synthetic analogs of Sildenafil are constantly detected as adulterants in counterfeit drugs and dietary supplements. Their intake constitutes a serious health hazard as side effects are unknown. In this paper an investigation is carried out on NMR and MS/MS spectra of Sildenafil, Thiosildenafil, Acetildenafil and thirteen of their analogs: a list of key signals is reported and discussed with the intent to provide a tool that can help in detecting adulteration and in elucidating the structure of novel analogs. In this view extensive spectral data were reported, discussed and summarized in tables. A discussion on mass fragmentation and NMR chemical shifts is also provided to rationalize assignation. Moreover, a comprehensive information on the route of synthesis is provided for the benefit of those medicines control laboratories that need to synthesize analogs reference standards in-house.


Asunto(s)
Espectroscopía de Resonancia Magnética/métodos , Piperazinas/análisis , Pirimidinas/análisis , Sulfonas/análisis , Espectrometría de Masas en Tándem/métodos , Medicamentos Falsificados/análisis , Suplementos Dietéticos/análisis , Contaminación de Medicamentos , Inhibidores de Fosfodiesterasa 5/análisis , Inhibidores de Fosfodiesterasa 5/química , Piperazinas/química , Purinas/análisis , Purinas/química , Pirimidinas/química , Citrato de Sildenafil , Sulfonas/química
7.
J Sex Med ; 9(8): 2130-7, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22612848

RESUMEN

INTRODUCTION: In developed countries the phenomenon of pharmaceutical counterfeiting is steadily increasing through the illegal and the Internet market. Medicines for the treatment of erectile dysfunctions containing phosphodiesterase type 5 inhibitors (PDE5) are especially prone to falsification. AIMS: To obtain evidence of the health risks for patients taking these products and to provide useful information to general practitioners and specialists in sexual medicine. METHODS: First the samples were visually inspected and then analyzed to get information about their identity and quality. MAIN OUTCOME MEASURES: A survey on the PDE5 medicines analyzed by the Italian official medicines control laboratory between 2005 and 2011 was performed. All the analyzed medicines were gathered from the Italian illegal market (seizures by police forces) or were bought from illegal online pharmacies. Results. The study revealed that 24% of the analyzed samples were counterfeit and 54% were illegal medicines. In 12% of the cases an intermediate classification (illegal/counterfeit) was assigned. Only 7% of the samples were original. Moreover, the examination of the packaging evidenced potential risks: outer and immediate packaging missing; inconsistency between the carton box and the blister as regards the expiry date and/or the batch number; expiry date or manufacturer's name or country missing. CONCLUSIONS: In 19% of the samples a potential health risk for patients was identified due to either the presence in the sample of more than one undeclared PDE5(s) or an amount of the active ingredient higher than that declared (up to 190% of the maximum dose) or to the presence of potentially dangerous excipients of non-pharmaceutical origin or quality (e.g., gypsum or non-purified talc).


Asunto(s)
Medicamentos Falsificados/administración & dosificación , Medicamentos Falsificados/efectos adversos , Disfunción Eréctil/tratamiento farmacológico , Fraude , Humanos , Internet , Italia , Masculino , Persona de Mediana Edad , Inhibidores de Fosfodiesterasa 5
8.
J Pharm Biomed Anal ; 53(2): 215-20, 2010 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-20547026

RESUMEN

The growth of pharmaceutical counterfeiting is a major public health problem. This growth is resulting in a proportional increase in the number of samples that medicines control laboratories have to test. Thus the need for simple and affordable preliminary screening methods to be used by inspectors to decide in the field whether to collect a sample for further laboratory analysis or not. This paper intends to evaluate the possibility to employ for preliminary examinations of suspicious samples an optical spectrophotometer (colorimeter) used in the graphic industry, capable of measuring the reflectance visible spectrum of solid materials. The colorimeter was tested on original and counterfeited Viagra, Cialis and Levitra by measuring the colour of tablets' surface and of a specific spot of the packages. Various batches of the original drugs were employed both to investigate precision and robustness of the technique and to build spectral libraries. These libraries were used to compare suspicious samples to the corresponding original by means of a wavelength distance pattern recognition method. The method was eventually tested on suspicious samples sized by police authorities in order to evaluate its effectiveness. The device resulted precise and robust toward ambient conditions changes, although some limits emerged: the libraries of original samples need a frequent update and a lower precision is to be expected for tablets which surface is extremely convex.


Asunto(s)
Colorimetría/instrumentación , Fraude/prevención & control , Reconocimiento de Normas Patrones Automatizadas/métodos , Comprimidos/análisis , Colorimetría/métodos , Embalaje de Medicamentos , Propiedades de Superficie
9.
J Pharm Biomed Anal ; 48(2): 477-81, 2008 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-18599248

RESUMEN

Diclofenac sodium is a nonsteroidal anti-inflammatory drug widely used in painful and inflammatory diseases. It can exist in different hydrate phases. Recently the physico-chemical and pharmaceutical properties of a trihydrate form, named DSH3 were reported by the same authors. This short communication discusses how samples of a same polymorphic form can display dissimilar analytical signatures when obtained by different routes. Data from hot-stage microscopy, FT-IR spectroscopy, X-ray powder diffraction (XRDP) and thermal analysis were used to characterise the DSH3 samples prepared by different methods. Through the case study of diclofenac sodium, this work highlights how the method used to prepare a specific crystal modification can generate samples with different morphologies and therefore different properties and physical stability.


Asunto(s)
Diclofenaco/química , Cristalización , Espectroscopía Infrarroja por Transformada de Fourier , Difracción de Rayos X
10.
J Pharm Biomed Anal ; 45(3): 443-9, 2007 Nov 05.
Artículo en Inglés | MEDLINE | ID: mdl-17709225

RESUMEN

Diclofenac sodium is a non-steroidal anti-inflammatory drug widely used in painful and inflammatory diseases. It can exist in different hydrate phases. By exposure to different conditions of temperature and relative humidity can be isolated a trihydrate form never described in literature. The methods of preparation of the trihydrate form (named DSH3) were described and its physico-chemical properties were investigated. Data from FTIR spectroscopy, X-ray powder diffraction and thermal analysis were used for identification and characterisation of DSH3 in comparison with the anhydrous form (DS, the commercial form) and the hydrate form DSH (obtained by exposure of DS to relative humidity even below 60% and already described and characterised in a previous article of the same authors). Intrinsic dissolution studies were performed to compare the pharmaceutical properties of DS and DSH with DSH3, since this form was accidentally found on the Italian market as active pharmaceutical ingredient (API). This work stresses the importance of assessing the correct crystalline form also in API of well-established use to guarantee quality, safety and efficacy of the final dosage form. Furthermore, this study suggests that isomorphic hydrate forms with a different dislocation of water within the crystal structures can exist.


Asunto(s)
Antiinflamatorios no Esteroideos/química , Diclofenaco/química , Rastreo Diferencial de Calorimetría , Cristalización , Estabilidad de Medicamentos , Solubilidad , Espectroscopía Infrarroja por Transformada de Fourier , Termodinámica , Agua/química , Difracción de Rayos X
11.
J Pharm Biomed Anal ; 42(1): 56-63, 2006 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-16870384

RESUMEN

A measurement result cannot be properly interpreted if not accompanied by its uncertainty. Several methods to estimate uncertainty have been developed. From those methods three in particular were chosen in this work to estimate the uncertainty of the Eu. Ph. chloroquine phosphate assay, a potentiometric titration commonly used in medicinal control laboratories. The famous error-budget approach (also called bottom-up or step-by-step) described by the ISO Guide to the expression of Uncertainty in Measurement (GUM) was the first method chosen. It is based on the combination of uncertainty contributions that have to be directly derived from the measurement process. The second method employed was the Analytical Method Committee top-down which estimates uncertainty through reproducibility obtained during inter-laboratory studies. Data for its application were collected in a proficiency testing study carried out by over 50 laboratories throughout Europe. The last method chosen was the one proposed by Barwick and Ellison. It uses a combination of precision, trueness and ruggedness data to estimate uncertainty. These data were collected from a validation process specifically designed for uncertainty estimation. All the three approaches presented a distinctive set of advantages and drawbacks in their implementation. An expanded uncertainty of about 1% was assessed for the assay investigated.


Asunto(s)
Cloroquina/análogos & derivados , Cloroquina/análisis , Potenciometría , Incertidumbre
12.
J Pharm Biomed Anal ; 40(5): 1105-13, 2006 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-16256287

RESUMEN

Diclofenac sodium is a non-steroidal anti-inflammatory drug widely used in painful and inflammatory diseases. In standard conditions, by exposure to relative humidity even below 60% at 25 degrees C, the anhydrous form DS gives rise to a hydrate species DSH, a tetrahydrate form different from that obtained by crystallisation from water and previously described. The method of preparation and the physico-chemical properties of the hydrate form were investigated. Data from FTIR spectroscopy, X-ray powder diffraction and thermal analysis were used for the identification and the characterisation of DSH. DS and DSH were easily differentiated by their IR spectra, X-ray patterns and thermal behaviour. DSH stability was followed at room temperature over a period of 1 year and under different conditions of temperature to verify the tendency to solid-solid transition and to study its existence range. Solubility and intrinsic dissolution studies were performed to compare the physico-chemical properties of DS and DSH. Differences in solubility and intrinsic dissolution rates were pointed out: these studies showed that DS dissolved faster than DSH. Storage under uncontrolled environmental conditions or contact with water vapour during manufacturing process could thus influence the performance of the final dosage form.


Asunto(s)
Diclofenaco/química , Calibración , Fenómenos Químicos , Química Física , Humedad , Indicadores y Reactivos , Solubilidad , Espectroscopía Infrarroja por Transformada de Fourier , Agua , Difracción de Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...