Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Nanoscale ; 15(12): 5689-5695, 2023 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-36880645

RESUMEN

2-Dimensional (2D) materials are attracting strong interest in printed electronics because of their unique properties and easy processability, enabling the fabrication of devices with low cost and mass scalable methods such as inkjet printing. For the fabrication of fully printed devices, it is of fundamental importance to develop a printable dielectric ink, providing good insulation and the ability to withstand large electric fields. Hexagonal boron nitride (h-BN) is typically used as a dielectric in printed devices. However, the h-BN film thickness is usually above 1 µm, hence limiting the use of h-BN in low-voltage applications. Furthermore, the h-BN ink is composed of nanosheets with broad lateral size and thickness distributions, due to the use of liquid-phase exfoliation (LPE). In this work, we investigate anatase TiO2 nanosheets (TiO2-NS), produced by a mass scalable bottom-up approach. We formulate the TiO2-NS into a water-based and printable solvent and demonstrate the use of the material with sub-micron thickness in printed diodes and transistors, hence validating the strong potential of TiO2-NS as a dielectric for printed electronics.

2.
Diagnostics (Basel) ; 13(4)2023 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-36832066

RESUMEN

(1) Purpose: To compare the diagnostic accuracy between full multiparametric contrast-enhanced prostate MRI (mpMRI) and abbreviated dual-sequence prostate MRI (dsMRI) in men with clinically significant prostate cancer (csPCa) who were candidates for active surveillance. (2) Materials and Methods: Fifty-four patients with a diagnosis of low-risk PCa in the previous 6 months had a mpMRI scan prior to a saturation biopsy and a subsequent MRI cognitive transperineal targeted biopsy (for PI-RADS ≥ 3 lesions). The dsMRI images were obtained from the mpMRI protocol. The images were selected by a study coordinator and assigned to two readers blinded to the biopsy results (R1 and R2). Inter-reader agreement for clinically significant cancer was evaluated with Cohen's kappa. The dsMRI and mpMRI accuracy was calculated for each reader (R1 and R2). The clinical utility of the dsMRI and mpMRI was investigated with a decision-analysis model. (3) Results: The dsMRI sensitivity and specificity were 83.3%, 31.0%, 75.0%, and 23.8%, respectively, for R1 and R2. The mpMRI sensitivity and specificity were 91.7%, 31.0%, 83.3%, and 23.8%, respectively, for R1 and R2. The inter-reader agreement for the detection of csPCa was moderate (k = 0.53) and good (k = 0.63) for dsMRI and mpMRI, respectively. The AUC values for the dsMRI were 0.77 and 0.62 for the R1 and R2, respectively. The AUC values for the mpMRI were 0.79 and 0.66 for R1 and R2, respectively. No AUC differences were found between the two MRI protocols. At any risk threshold, the mpMRI showed a higher net benefit than the dsMRI for both R1 and R2. (4) Conclusions: The dsMRI and mpMRI showed similar diagnostic accuracy for csPCa in male candidates for active surveillance.

3.
Nanoscale ; 12(12): 6708-6716, 2020 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-32186302

RESUMEN

We report room temperature Hall mobility measurements, low temperature magnetoresistance analysis and low-frequency noise characterization of inkjet-printed graphene films on fused quartz and SiO2/Si substrates. We found that thermal annealing in vacuum at 450 °C is a necessary step in order to stabilize the Hall voltage across the devices, allowing their electrical characterization. The printed films present a minimum sheet resistance of 23.3 Ω sq-1 after annealing, and are n-type doped, with carrier concentrations in the low 1020 cm-3 range. The charge carrier mobility is found to increase with increasing film thickness, reaching a maximum value of 33 cm2 V-1 s-1 for a 480 nm-thick film printed on SiO2/Si. Low-frequency noise characterization shows a 1/f noise behavior and a Hooge parameter in the range of 0.1-1. These results represent the first in-depth electrical and noise characterization of transport in inkjet-printed graphene films, able to provide physical insights on the mechanisms at play.

4.
ACS Nano ; 13(1): 54-60, 2019 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-30452230

RESUMEN

A well-defined insulating layer is of primary importance in the fabrication of passive ( e.g., capacitors) and active ( e.g., transistors) components in integrated circuits. One of the most widely known two-dimensional (2D) dielectric materials is hexagonal boron nitride (hBN). Solution-based techniques are cost-effective and allow simple methods to be used for device fabrication. In particular, inkjet printing is a low-cost, noncontact approach, which also allows for device design flexibility, produces no material wastage, and offers compatibility with almost any surface of interest, including flexible substrates. In this work, we use water-based and biocompatible graphene and hBN inks to fabricate all-2D material and inkjet-printed capacitors. We demonstrate an areal capacitance of 2.0 ± 0.3 nF cm-2 for a dielectric thickness of ∼3 µm and negligible leakage currents, averaged across more than 100 devices. This gives rise to a derived dielectric constant of 6.1 ± 1.7. The inkjet printed hBN dielectric has a breakdown field of 1.9 ± 0.3 MV cm-1. Fully printed capacitors with sub-micrometer hBN layer thicknesses have also been demonstrated. The capacitors are then exploited in two fully printed demonstrators: a resistor-capacitor (RC) low-pass filter and a graphene-based field effect transistor.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...