Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Brachytherapy ; 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38724315

RESUMEN

PURPOSES: In this study we aim to quantitatively evaluate the stability of implanted seeds in permanent breast seed implant (PBSI) brachytherapy and assess any impact on treatment quality. METHODS AND MATERIALS: Sixty-seven consecutive patients who received PBSI treatment at BC Cancer Kelowna from 2013 to 2021 with post-implant CT images available were included in this study. For each patient, two sets of post-implant CT scans were retrospectively analyzed: Day0, obtained immediately after implant, and Day30, obtained approximately one month following implant. Seed distributions were quantified using the 90% isodose contour, outlier seed maximum spread, and number of seeds located in the seroma as well as seroma quadrants. These were then compared between Day0 and Day30. Post-implant dosimetry of target volumes as well as critical structures were compared. RESULTS: The 90% isodose volume was found to decrease over time. All seeds remained in the breast region however the maximum spread of seeds increased in all directions from Day0 to Day30. All recorded target volume dosimetric parameters were, on average, lower on Day30 compared to Day0 but mean dosimetry levels still met clinical goals. Dose in critical structures was overall similar. CONCLUSIONS: In this study, we quantitatively described the changes in seed distributions as well as dosimetry from Day0 to Day30 post PBSI procedure. We addressed concerns related to seed stability in breast tissue and provided clinical evidence on dosimetric efficacy of the PBSI technique.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38493901

RESUMEN

PURPOSE: To compare health-related quality of life (QoL) in urinary, bowel, and sexual domains after combined external beam radiation therapy (EBRT) and either low-dose rate (LDR) or high-dose rate (HDR) prostate brachytherapy (BT). METHODS AND MATERIALS: Eligible men with intermediate or high-risk prostate cancer treated with combined pelvic EBRT and BT were randomly assigned to either HDR (15 Gy) or LDR (110 Gy) boost. International Prostate Symptom Score, Index of Erectile Function, and Expanded Prostate Cancer Composite were collected at baseline, 1, 3, 6, and 12 months, every 6 months to 3 years and then annually along with prostate-specific antigen/testosterone. Fisher's exact test compared categorical variables and the Mann-Whitney U test Expanded Prostate Cancer Index Composite (EPIC) domain scores. RESULTS: From January 2014 to December 2019, a random number generator assigned 195 men: 108 to HDR and 87 to LDR. Median age was 71 years. Risk group was high in 57% and unfavorable intermediate in 43%. Androgen deprivation (used in 74%) began with 3 months neoadjuvant and continued for median 12 months. Baseline EPIC scores were similar for the LDR/HDR cohorts: 89 and 88 respectively for Genito-urinary; 92 and 93 for Gastro-intestinal. EPIC urinary scores decreased at 1 month for HDR but recovered promptly to a steady state by 6 months. LDR scores reached a nadir at 3 months with slow recovery to 18 months, after which urinary QoL was similar for HDR and LDR. Bowel QOL scores fell in both cohorts reaching respective nadirs at 12 months. HDR patients recovered close to baseline and maintained higher scores than LDR patients to 5 years. The decline for LDR patients remained more than the minimum clinically important difference out to 5 years. CONCLUSIONS: The patient experience for combined EBRT and prostate BT is improved with HDR BT. Urinary QoL improves over time to be equivalent between the 2 modalities after 18 months, but LDR patients report lasting bowel symptoms.

3.
Brachytherapy ; 23(1): 85-95, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37949759

RESUMEN

BACKGROUND: Permanent breast seed implant (PBSI) brachytherapy is a promising treatment that has the potential to be widely utilized with increased standardization, optimization, and robustness. Excellent early efficacy and very high patient acceptance were reported, however, to further evaluate and improve planning strategies, a framework to quantify plan robustness to implant uncertainties is necessary. PURPOSE: In this study, we aim to quantify clinical seed displacement using an automated algorithm and develop and validate a PBSI post-implant dosimetry simulation framework to evaluate PBSI plan robustness to implant uncertainties. METHODS AND MATERIALS: Clinical PBSI seed displacements were quantified for 63 consecutive patients. A PBSI simulator was developed in Matlab (2020) by resampling clinical seed displacements and computing a range of possible post-implant dosimetry outcomes under various seed displacement scenarios. Simulations were performed retrospectively on 63 previous clinical plans to evaluate plan robustness to seed displacement. RESULTS: Mean seed displacement for the whole cohort was 10 ± 6 mm. A clinical seed displacement database was established and a user interface was developed for the simulation framework. For all clinical plans, the median (range) value of simulated median ETV V90 in various seed displacement scenarios was 97.8% (87.5-100%). CONCLUSIONS: A PBSI postimplant dosimetry simulation framework was developed and validated. Simulation results showed that the current PTV planning margin is sufficient to provide adequate postimplant dose coverage of ETV. This simulator can be used to evaluate plan robustness to seed displacement and will facilitate future research in improving PBSI planning methods.


Asunto(s)
Braquiterapia , Humanos , Braquiterapia/métodos , Estudios Retrospectivos , Mama , Prótesis e Implantes , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos
4.
Brachytherapy ; 22(4): 468-476, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37169607

RESUMEN

PURPOSE: Delivering highly conformal treatment plans for high-dose rate vaginal brachytherapy using commercially available applicators can be challenging. A partially automated workflow is presented for the in-house modeling and 3D printing of patient-specific cylindrical templates (PSCTs), which facilitate placement of flexible intracavitary and interstitial needles. To demonstrate feasibility, we compare PSCT treatment plans to retrospective interstitial brachytherapy plans delivered at our center. PSCTs derived from these plans were 3D printed to test the validity of the auto-design process. To facilitate clinical implementation, we validated the steam sterilization compatibility of PSCTs printed using polyetheretherketone (PEEK). METHODS AND MATERIALS: Plans for ten patients treated using a combination of vaginal cylinder and interstitial needles were compared to PSCT-based plans created for the same patient. DVH parameters for the HRCTV (V100, V150, V200, D90) and OARs (D2 cm3) were evaluated, as well as the number of needles used and the total interstitial length. Each planned PSCT was printed and compared to the intended needle geometry. 3D printed models were sterilization validated by an independent contractor for an autoclave protocol. RESULTS: PSCT plans demonstrated advantages over template based perineal BT in reducing the total interstitial needle length required while preserving or improving HRCTV and OAR dosimetry. All printed PSCTs matched planned geometry. CONCLUSIONS: PSCTs stand to be an alternative to current HDR-BT templates/applicators for patients with vaginal and locally recurrent endometrial cancers. Clinically equivalent or improved treatment plans can be created and devices to deliver these plans can be accurately printed and sterilized.


Asunto(s)
Braquiterapia , Femenino , Humanos , Braquiterapia/métodos , Estudios de Factibilidad , Estudios Retrospectivos , Dosificación Radioterapéutica , Recurrencia Local de Neoplasia/etiología , Impresión Tridimensional , Planificación de la Radioterapia Asistida por Computador/métodos
5.
Brachytherapy ; 22(1): 101-107, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36244908

RESUMEN

PURPOSE: This study investigates the feasibility and potential impacts of utilizing a Groupe Européen de Curiethérapie-European Society for Therapeutic Radiation and Oncology (GEC ESTRO) recommended surgical margin-based planning margin in permanent breast seed implant (PBSI) brachytherapy. METHODS AND MATERIALS: Seventy-nine patients were included in this retrospective study. Three margin selections were used for PTV construction: (1) 1.25 or 1.5 cm isotropic margin (PTVPBSI), (2) 2 cm minus surgical margin in each direction as recommended by GEC ESTRO (PTVaniso), and (3) 2 cm minus minimum surgical margin isotropically (PTViso). PTV volume and dose coverage using clinical PBSI plans were compared across three groups. New PBSI plans were constructed on PTVaniso for 20 patients and planning parameters were compared to original plans constructed on PTVPBSI. RESULTS: Twenty patients had surgical margins in six directions reported, with a median value of 8 mm anteriorly, and 10 mm in all other directions. PTVaniso (36.3 ± 15.0 cc) was overall smaller than PTVPBSI (55.6 ± 14.3 cc), p value < 0.05. PBSI clinical plans showed satisfactory coverage on PTVaniso, with a median (range) V100 of 97.9% (85.8%-100.0%). Comparing to original treatment plans, new plans constructed on PTVaniso reduced the number of implant seeds and skin dose. CONCLUSIONS: Clinical PBSI plans provide satisfactory coverage of GEC ESTRO recommended PTVs. In this patient cohort, GEC ESTRO planning margin resulted in smaller target volumes, and therefore, new plans constructed on PTVaniso required fewer implanted seeds and lower skin doses were achieved. However, given PBSI delivery uncertainties, further investigations are required to determine if the GEC ESTRO planning margin will be sufficiently robust.


Asunto(s)
Braquiterapia , Humanos , Braquiterapia/métodos , Estudios de Factibilidad , Márgenes de Escisión , Estudios Retrospectivos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos
6.
Brachytherapy ; 20(3): 686-694, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33551273

RESUMEN

PURPOSE: Permanent breast seed implant using 103Pd is emerging as an effective adjuvant radiation technique for early stage breast cancer. However, clinical dose evaluations follow the water-based TG-43 approach with its considerable approximations. Toward clinical adoption of advanced TG-186 model-based dose evaluations, this study presents a comprehensive investigation for permanent breast seed implant considering both target and normal tissue doses. METHODS AND MATERIALS: Dose calculations are performed with the free open-source Monte Carlo (MC) code, egs_brachy, using two types of virtual patient models: TG43sim (simulated TG-43 conditions) and MCref (heterogeneous tissue modeling from patient CT, seeds at implant angle) for 35 patients. The sensitivity of dose metrics to seed orientation and tissue segmentation are assessed. RESULTS: In the target volume, D90 is 14.1 ± 5.8% lower with MCref than with TG43sim, on average. Conversely, normal tissue doses are generally higher with MCref than with TG43sim, for example, by 22 ± 13% for skin D1cm2, 82 ± 7% for ribs Dmax, and 71 ± 23% for heart D1cm3. Discrepancies between MCref and TG43sim doses vary over the patient cohort, as well as with the tissue and metric considered. Skin doses are particularly sensitive to seed orientation, with average difference of 4% (maximum 28%) in D1cm2 for seeds modeled vertically (egs_brachy default) compared with those aligned with implant angle. CONCLUSIONS: TG-43 dose evaluations generally underestimate doses to critical normal organs/tissues while overestimating target doses. There is considerable variation in MCref and TG43sim on a patient-by-patient basis, motivating clinical adoption of patient-specific MC dose calculations. The MCref framework presented herein provides a consistent modeling approach for clinical implementation of advanced TG-186 dose calculations.


Asunto(s)
Braquiterapia , Braquiterapia/métodos , Mama/diagnóstico por imagen , Humanos , Método de Montecarlo , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
7.
Brachytherapy ; 20(1): 248-256, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-32900644

RESUMEN

PURPOSE: Permanent breast seed implant (PBSI) brachytherapy is a novel technique for early-stage breast cancer. Computed tomography (CT) images are used for treatment planning and freehand 2D ultrasound for implant guidance. The multimodality imaging approach leads to discrepancies in target identification. To address this, a prototype 3D ultrasound (3DUS) system was recently developed for PBSI. In this study, we characterize the 3DUS system performance, establish QA baselines, and develop and test a method to register 3DUS images to CT images for PBSI planning. METHODS AND MATERIALS: 3DUS system performance was characterized by testing distance and volume measurement accuracy, and needle template alignment accuracy. 3DUS-CT registration was achieved through point-based registration using a 3D-printed model designed and constructed to provide visible landmarks on both images and tested on an in-house made gel breast phantom. RESULTS: The 3DUS system mean distance measurement accuracy was within 1% in axial, lateral, and elevational directions. A volumetric error of 3% was observed. The mean needle template alignment error was 1.0° ± 0.3 ° and 1.3 ± 0.5 mm. The mean 3DUS-CT registration error was within 3 mm when imaging at the breast centre or across all breast quadrants. CONCLUSIONS: This study provided baseline data to characterize the performance of a prototype 3DUS system for PBSI planning and developed and tested a method to obtain accurate 3DUS-CT image registration for PBSI planning. Future work will focus on system validation and characterization in a clinical context as well as the assessment of impact on treatment plans.


Asunto(s)
Braquiterapia , Braquiterapia/métodos , Mama , Humanos , Imagenología Tridimensional , Fantasmas de Imagen , Ultrasonografía
8.
Med Phys ; 47(12): 5976-5985, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33034047

RESUMEN

The labor force of Medical Physics is one of the most gender diverse in the field of Physics, as it has attained the proportional achievement of ~30% women worldwide (Tsapaki et al. Phys Medica. 2018;55:33-39). While great strides have been made toward a gender diverse workforce, women still comprise an underrepresented group. Many strategies have been suggested to increase the participation of underrepresented persons by addressing unconscious biases, increasing opportunities, dedicated hiring policies, and providing support networks in science and medicine (Barabino et al. Sci Eng Ethics. 2019; Coe et al. Lancet. 2019), yet the personnel landscape remains largely uniform. Herein, the conditions, strategies, and approaches that facilitated gender diversity in Medical Physics are considered as a means to further the inclusion of other underrepresented groups through exemplars of mentorship, addressing unconscious biases and the implementation of inclusive practices. Furthermore, the potential for gender diversity to act as a catalyst to create an environment that is more accepting of diversity and supports and encourages inclusive practices for the participation and inclusion of other underrepresented groups in Medical Physics is discussed.


Asunto(s)
Física , Femenino , Humanos , Masculino
9.
Brachytherapy ; 19(5): 685-693, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32739213

RESUMEN

PURPOSE: To establish skin dose-outcome relationships using a reliable metric in permanent breast seed implant (PBSI). METHODS: Sixty-seven consecutive patients who underwent PBSI at our institution were included. Skin doses were calculated using two skin dose indices: maximum point dose to the skin surface, Dmax, and D0.2cc for a 2-mm internal skin rind (a surrogate to the dose to 1 cm2 area of skin) from CT-based postoperative treatment plans. Toxicity data were extracted from patients' charts and photographs. The associations between skin dose and skin toxicity were investigated using the analysis of variance, and the predictive performance of skin dose measures was evaluated using receiver operating characteristic curves. RESULTS: For acute reactions, 49.3% of patients had Grade 1, 4.5% Grade 2, and 1.5% Grade 3 toxicity. For telangiectasia at 3 years, very minor and minimally apparent telangiectasia was observed in 25% of patients. Moderate but asymptomatic telangiectasia was observed in 9.1% of cases. Both metrics were significantly associated with the occurrence of acute toxicity and telangiectasia at 3 years (p < 0.01). The predictive values for Dmax and D0.2cc were 0.779 and 0.763, respectively, (p < 0.0001) for acute skin toxicity and 0.786 and 0.810 for telangiectasia (p < 0.0002). Extreme dose outliers (up to 878 Gy) and a high variability were observed for Dmax but not for D0.2cc, illustrating the superior reliability of D0.2cc. CONCLUSION: D0.2cc, as an alternate skin dose measure to Dmax, is a robust metric for measuring skin dose that is simple to calculate, yet is clinically relevant and not prone to inaccuracies inherent to point dose measurement.


Asunto(s)
Braquiterapia/métodos , Neoplasias de la Mama/radioterapia , Radiodermatitis/epidemiología , Telangiectasia/epidemiología , Anciano , Anciano de 80 o más Años , Mama , Relación Dosis-Respuesta en la Radiación , Femenino , Humanos , Persona de Mediana Edad , Traumatismos por Radiación/epidemiología , Dosificación Radioterapéutica , Reproducibilidad de los Resultados , Piel
10.
Brachytherapy ; 19(6): 794-799, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32402545

RESUMEN

PURPOSE: The purpose of the study was to establish a quantitative method for implant quality evaluation in permanent seed implant brachytherapy for credentialing. Delivery-based credentialing will promote consistency in brachytherapy seed delivery and improve patient outcomes. METHODS: A workflow for delivery-based credentialing was outlined and applied to permanent breast seed implant brachytherapy. Delivery simulations were performed on implantable anthropomorphic breast phantoms. Two institutions experienced in permanent seed implant brachytherapy demonstrated the peer credentialing process. Each delivery was evaluated for seed placement accuracy as the measure of implant quality, both for implant accuracy and across five simulations to assess implant variation. Initial credentialing criteria are set based on two factors; the mean seed placement accuracy (implant accuracy) and the mean standard deviation (seed variation) with the threshold for each set with the addition of two standard deviations. RESULTS: Across two institutions, seed placement accuracy (±standard deviation) was calculated for all five delivery simulations to yield 6.1 (±2.6) mm. To set credentialing criteria, the implant accuracy (6.1 mm) plus two standard deviations (2.0 mm) and the seed variation (2.6 mm) plus two standard deviations (0.8) mm yield a threshold of 8.1 ± 3.4 mm. It is expected that 95% of experienced institutions would perform the phantom simulation within this threshold. CONCLUSION: Brachytherapy programs should validate delivery accuracy by formal credentialing, which is standard in external beam programs. This quantitative implant evaluation should be combined with current credentialing standards for permanent seed brachytherapy to form a comprehensive validation of institutional brachytherapy program quality.


Asunto(s)
Braquiterapia/normas , Neoplasias de la Mama/radioterapia , Habilitación Profesional/normas , Braquiterapia/instrumentación , Mama , Femenino , Humanos , Fantasmas de Imagen , Entrenamiento Simulado
11.
Brachytherapy ; 19(3): 316-322, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32229073

RESUMEN

PURPOSE: Cervical cancer is the leading cause of cancer mortality of women in low-/middle-income countries. Interstitial needles improve outcomes but require resources beyond those available in endemic regions. We conducted a retrospective review of the use of interstitial needles in locally advanced cervical cancer and simulated both 3D planning without needles and 2D planning to explore the benefit of interstitial needles. METHODS AND MATERIALS: 57 brachytherapy plans of 17 patients who had intracavitary tandem and ring plus interstitial brachytherapy were reviewed. Prescribed dose was 7 Gy × four fractions. 2D plans prescribed to point A were generated to represent a standard Manchester loading. Dosimetric outcomes to clinical target volume and organs at risk (OARs) were compared with those of 3D-based plans. RESULTS: High-risk clinical target volume coverage was excellent: 93.2% for 2D plans, 93.9% for 3D plans without needles, and 96.2% for 3D with needles. The mean dose to 90% of target was 8.5 Gy/fraction for 2D plans, 7.5 for 3D without needles, and 7.9 Gy/fraction for 3D with needles. However, the 2D plans delivered 12% above recommended dose constraints for OARs (except rectum). Dosimetric differences were found between 3D planning and 3D with needles for target coverage (p = 0.002). Dose to OARs was significantly lower when 3D plans with needles were compared with 2D plans. CONCLUSIONS: Interstitial needles provide an optimal therapeutic ratio for patients with high-volume disease or/and unfavorable topography. This justifies additional capital investment in resources for implementation to provide optimal treatment for locally advanced cervical cancer globally.


Asunto(s)
Braquiterapia/métodos , Países en Desarrollo , Órganos en Riesgo , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias del Cuello Uterino/radioterapia , Adulto , Braquiterapia/instrumentación , Femenino , Humanos , Persona de Mediana Edad , Agujas , Dosis de Radiación , Dosificación Radioterapéutica , Recto , Estudios Retrospectivos
12.
Brachytherapy ; 19(2): 201-209, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31959520

RESUMEN

PURPOSE: High-dose-rate (HDR) brachytherapy is a convenient treatment option for selected patients with T1-T2 penile squamous cell carcinoma (SCC), providing high rates of penile preservation and tumor control. We present the results of penile SCC treated with HDR brachytherapy either interstitially or via a surface mold. METHODS AND MATERIALS: Between November 2009 and April 2019, seven patients (2 T1a and 5 T2) were treated with interstitial HDR and 8 (1 Tis, six T1a, and one T1b) with surface mold. Prescribed dose for interstitial patients ranged from 38.4 Gy in 6 days (3.2 Gy × 12) to 53 Gy in 9 days (3.12 × 17), BID. All patients treated with mold brachytherapy received 40 Gy in 10 fractions BID. Toxicity and oncological results were assessed for both groups, and their relation with dosimetry is described. RESULTS: Median follow up was 90 months for interstitial and 27 months for those treated with surface mold. Fourteen of 15 patients are alive and disease-free; one surface mold patient died of non-small-cell lung cancer. There was one relapse in each group, each treated with salvage penectomy. The potency was preserved in 82%. For interstitial, G2 necrosis occurred in 43%, G2 meatal stenosis in 29% and G3 stenosis in 14%. CONCLUSIONS: Both techniques have excellent rates of tumor control and organ preservation. Implant geometry and homogeneity constraints must be carefully designed to minimize toxicity in interstitial brachytherapy. Urethral contouring and reporting of dosimetric parameters should be defined.


Asunto(s)
Braquiterapia/métodos , Carcinoma de Células Escamosas/radioterapia , Recurrencia Local de Neoplasia/cirugía , Neoplasias del Pene/radioterapia , Adulto , Anciano , Braquiterapia/efectos adversos , Carcinoma de Células Escamosas/patología , Supervivencia sin Enfermedad , Humanos , Masculino , Persona de Mediana Edad , Necrosis/etiología , Estadificación de Neoplasias , Neoplasias del Pene/patología , Pene/patología , Dosificación Radioterapéutica , Estrechez Uretral/etiología
13.
Brachytherapy ; 19(6): 812-819, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31786168

RESUMEN

PURPOSE: The purpose of this study was to establish a simulation-based education program for radiation oncology learners in permanent seed implant brachytherapy. The first step in formalizing any education program is a validation process that builds evidence-based verification that the learning environment is appropriate. METHODS AND MATERIALS: The primary education task allowed practitioners to use an anthropomorphic breast phantom to simulate a permanent seed implant brachytherapy delivery. Validation evidence is built by generating data to assess learner and expert cohorts according to their proficiency. Each practitioner's performance during the simulation was evaluated by seed placement accuracy, procedural time-to-complete, and two qualitative evaluation tools-a global rating scale and procedural checklist. RESULTS: The average seed placement accuracy (±SD) was 8.1 ± 3.5 mm compared to 6.1 ± 2.6 mm for the learner and expert cohort, respectively. The median (range) procedural time-to-complete was 64 (60-77) minutes and 43 (41-50) minutes for the learner and expert cohort, respectively. Seed placement accuracy (student t-test, p < 0.05) and procedural time-to-complete (Mann-Whitney U-test, p < 0.05) were statistically different between the cohorts. In both the global rating scale and procedural checklist, the expert cohort demonstrated improved proficiency compared to the learner cohort. CONCLUSIONS: This validation evidence supports the utilization of this simulation environment toward appropriately capturing the delivery experience of practitioners. The results demonstrate that, in all areas of evaluation, expert cohort proficiency was superior to learner cohort proficiency. This methodology will be used to establish a simulation-based education program for radiation oncology learners in permanent seed implant brachytherapy.


Asunto(s)
Braquiterapia/normas , Neoplasias de la Mama/radioterapia , Oncología por Radiación/educación , Entrenamiento Simulado/métodos , Braquiterapia/instrumentación , Mama , Competencia Clínica , Becas , Femenino , Humanos , Internado y Residencia , Fantasmas de Imagen , Dosificación Radioterapéutica , Factores de Tiempo
14.
Semin Radiat Oncol ; 30(1): 49-60, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31727300

RESUMEN

Brachytherapy has become an essential pillar in all-stages of localized prostate cancer, where dose escalation has been demonstrated to improve outcome. HDR brachytherapy has evolved over the decades to be administered in 1-2 fractions. As either monotherapy or in combination with external beam, it offers many advantages over other treatment alternatives. Precise control over dose delivery allows focal dose escalation while sculpting dose around critical organs to maintain excellent tolerance. The high dose per fraction exploits the low α/ß ratio of prostate cancer and triggers transcriptional changes in the tumor genome enhancing radiation sensitivity. We review the development, patient selection and results, and describe in detail the techniques for HDR brachytherapy.


Asunto(s)
Braquiterapia/métodos , Neoplasias de la Próstata/radioterapia , Braquiterapia/efectos adversos , Terapia Combinada , Fraccionamiento de la Dosis de Radiación , Humanos , Imagen por Resonancia Magnética , Masculino , Neoplasias de la Próstata/patología , Tolerancia a Radiación , Dosificación Radioterapéutica , Tomografía Computarizada por Rayos X
15.
Brachytherapy ; 18(5): 675-682, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31248822

RESUMEN

PURPOSE: This study characterizes prostatic urethra cross-section to develop a surrogate urethra for accurate prediction of urethral dose during real-time high-dose-rate prostate brachytherapy. MATERIALS AND METHODS: Archived preoperative transrectal ultrasound images from 100 patients receiving low-dose-rate prostate brachytherapy were used to characterize the prostatic urethra, contoured on ultrasound using aerated gel. Consensus contours, defined using majority vote, described commonalities in cross-sectional shape across patients. Potential simplified surrogates were defined and evaluated against the true urethra. The best performing surrogate, a circle of varying size (CS) was retrospectively contoured on 85 high-dose-rate prostate brachytherapy treatment plans. Dose to this recommended surrogate was compared with urethral doses estimated by the standard 6 mm circle surrogate. RESULTS: Clear variation in urethral cross-sectional shape was observed along its length and between patients. The standard circle surrogate had low predictive sensitivity (61.1%) compared with true urethra because of underrepresentation of the verumontanum midgland. The CS best represented the true urethra across all validation metrics (dice: 0.73, precision: 67.0%, sensitivity: 83.2%, conformity: 0.78). Retrospective evaluation of planned doses using the CS surrogate resulted in significant differences in all reported urethral dose parameters compared with the standard circle, with the exception of D100%. The urethral dose limit (115%) was exceeded in 40% of patients for the CS surrogate. CONCLUSIONS: The proposed CS surrogate, consisting of circles of varying diameter, is simple yet better represents the true urethra compared with the standard 6 mm circle. Higher urethral doses were predicted using CS, and the improved accuracy of CS may offer increased predictive power for urethral toxicity, a subject of future work.


Asunto(s)
Braquiterapia/métodos , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Uretra/efectos de la radiación , Braquiterapia/efectos adversos , Estudios Transversales , Humanos , Masculino , Órganos en Riesgo/diagnóstico por imagen , Órganos en Riesgo/efectos de la radiación , Próstata/diagnóstico por imagen , Próstata/patología , Neoplasias de la Próstata/diagnóstico por imagen , Dosis de Radiación , Traumatismos por Radiación/etiología , Traumatismos por Radiación/prevención & control , Radiometría/métodos , Dosificación Radioterapéutica , Estudios Retrospectivos , Ultrasonografía/métodos , Uretra/diagnóstico por imagen , Uretra/patología
16.
Brachytherapy ; 18(4): 510-520, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31109871

RESUMEN

PURPOSE: Adjuvant partial breast radiotherapy is the standard of care for early-stage favorable breast cancer. We report dosimetry, acute and late tolerance for 67 permanent breast seed implants. MATERIALS AND METHODS: From July 2012 to October 2018, 67 postmenopausal women with unifocal pT1pN0 invasive ductal or ductal carcinoma in situ received partial breast radiotherapy using stranded Pd-103 seeds after breast-conserving surgery, delivering 90 Gy to the seroma + margin (1.25-1.5 cm), planned with computed tomography simulation and performed as an ultrasound-guided outpatient procedure. The planning and postimplant computed tomography images were fused for seroma delineation for postimplant dosimetry. Evaluations were performed at 1, 2, 6, and 12 months and then annually. RESULTS: Although patient acceptance is high, only 40% met technical requirements of seroma volume, location, and visibility. For 67 patients, the median seroma volume was 6.6 cc, PTV 61 cc, and number of needles 18. In day 0 dosimetry, median seroma D90 dose was 132 Gy; seroma + 5 mm, 106 Gy; and seroma + 10 mm, 80 Gy. Peak reaction at 6 weeks is limited to the implant site: 51% grade 1 erythema and 12% focal desquamation. Late reactions (>2 years) are generally minimal: 35% no sequelae, 43% localized fibrosis, 20% mild telangiectasia (6% moderate but asymptomatic), 22% contour change. At minimum 6-month follow-up, 94% were "very or totally satisfied." Recurrences (median follow-up: 3.3 years) were one in breast (different quadrant) and 2 contralateral. Three patients have had biopsies of fibrosis, all negative for malignancy. CONCLUSIONS: Our experience with permanent breast seed implant is favorable with a high patient acceptance and satisfaction, excellent early efficacy, and very satisfactory cosmesis.


Asunto(s)
Braquiterapia/métodos , Neoplasias de la Mama/radioterapia , Carcinoma Ductal de Mama/radioterapia , Carcinoma Intraductal no Infiltrante/radioterapia , Recurrencia Local de Neoplasia , Seroma/etiología , Anciano , Anciano de 80 o más Años , Braquiterapia/efectos adversos , Neoplasias de la Mama/patología , Neoplasias de la Mama/cirugía , Carcinoma Ductal de Mama/patología , Carcinoma Ductal de Mama/cirugía , Carcinoma Intraductal no Infiltrante/patología , Carcinoma Intraductal no Infiltrante/cirugía , Femenino , Humanos , Mastectomía Segmentaria/efectos adversos , Persona de Mediana Edad , Recurrencia Local de Neoplasia/patología , Paladio/uso terapéutico , Satisfacción del Paciente , Radioisótopos/uso terapéutico , Dosificación Radioterapéutica , Radioterapia Adyuvante , Seroma/diagnóstico por imagen , Tomografía Computarizada por Rayos X
17.
Brachytherapy ; 18(3): 299-305, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30795889

RESUMEN

PURPOSE: To present the dosimetric results of a Phase II randomized trial comparing dose escalation to the MRI-defined dominant intraprostatic lesion (DIL) using either low-dose-rate (LDR) or high-dose-rate (HDR) prostate brachytherapy. MATERIAL AND METHODS: Patients receiving prostate brachytherapy as monotherapy were randomized to LDR or HDR brachytherapy. Prostate and DILs were contoured on preoperative multiparametric MRI. These images were registered with transrectal ultrasound for treatment planning. LDR brachytherapy was preplanned using I-125 seeds. HDR brachytherapy used intraoperative transrectal ultrasound-based planning to deliver 27 Gy/2 fractions in separate implants. DIL location was classified as peripheral, central, or anterior. A student t-test compared DIL D90 between modalities and DIL locations. RESULTS: Of 60 patients, 31 underwent LDR and 29 HDR brachytherapy. Up to three DILs were identified per patient (100 total) with 74 peripheral, six central, and 20 anterior DILs. Mean DIL volume was 1.9 cc (SD: 1.7 cc) for LDR and 1.6 cc (SD 1.3 cc) for HDR (p = 0.279). Mean DIL D90 was 151% (SD 30%) for LDR and 132% (SD 13%) for HDR. For LDR, mean peripheral DIL D90 was 159% (SD 27%) and central or anterior 127% (SD 13%). HDR peripheral DILs received 137% (SD 12%) and central or anterior 119% (SD 7%). DIL D90 for peripheral lesions was higher than anterior and central (p < 0.001). CONCLUSIONS: DIL location affects dose escalation, particularly because of urethral proximity, such as for anterior and central DILs. HDR brachytherapy may dose escalate better when target DIL is close to critical organs.


Asunto(s)
Braquiterapia/métodos , Neoplasias Primarias Múltiples/radioterapia , Neoplasias de la Próstata/radioterapia , Humanos , Radioisótopos de Yodo , Imagen por Resonancia Magnética , Masculino , Neoplasias Primarias Múltiples/diagnóstico por imagen , Neoplasias Primarias Múltiples/patología , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Carga Tumoral , Uretra/patología
18.
Pract Radiat Oncol ; 9(3): e314-e321, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30641244

RESUMEN

PURPOSE: This study aimed to evaluate the relationship between seroma visualization and seed placement accuracy in permanent breast seed implant brachytherapy (PBSI). METHODS AND MATERIALS: At the time of planning computed tomography (CT), 10 patients receiving PBSI were imaged with spatially co-registered 3-dimensional ultrasound (US). Seromas were independently contoured by 3 radiation oncologists on CT and US scans. Intra- and interuser conformity indices (CIs) were used as a surrogate for seroma visualization. Intermodality visualization differences were assessed by defining consensus contours, clinical target volume (CTV)CT and CTVUS, and evaluating the CI and the centroid position and volume differences. Seed placement accuracy was represented by the differences between the planned and implanted seed positions (displacements). Correlations among total, systematic, and random seed displacements and seroma visualization metrics were assessed. RESULTS: The median (range) intra-user CI of CT seroma contouring was 0.60 (0.46-0.72), and the median interuser CIs were 0.46 (0.38-0.58) and 0.50 (0.29-0.67) on CT and US, respectively. The CTVUS was a mean 68% ± 12% smaller than CTVCT and differed in centroid position by 8 ± 3 mm. Seeds were placed, on average, 10 ± 5 mm from their planned positions, and intrapatient systematic displacements were observed. The mean seed displacements for the implants were shown to correlate with interuser CI on CT (r = .74; P = .01) and volume differences between CTVCT and CTVUS (r = .65; P = .04), but not with intrauser CI, intermodality CI or centroid differences. Systematic displacements were correlated with interuser CT CI (r = .67; P = .03) and intermodality volume difference (r = .64; P = .04), but random seed displacements were independent of all evaluated metrics. CONCLUSIONS: Consistency in seroma delineation in treatment planning and differences between seroma visualized on CT and US scans are associated with seed placement accuracy in PBSI. Efforts to enhance seroma visualization in treatment planning and implant guidance may have a positive impact on treatment quality and should be pursued to facilitate the widespread implementation of this technique.


Asunto(s)
Braquiterapia/métodos , Neoplasias de la Mama/radioterapia , Seroma/diagnóstico por imagen , Braquiterapia/instrumentación , Neoplasias de la Mama/patología , Femenino , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Ultrasonografía Mamaria/métodos
19.
Med Phys ; 2018 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-29791029

RESUMEN

PURPOSE: Permanent breast seed implantation (PBSI) is a promising radiotherapy technique for early-stage breast cancer, completed in a single visit by permanently implanting 103 Pd seeds using needles inserted through a template and guided by two-dimensional (2D) ultrasound (US). However, operator dependence has been highlighted as a limitation of this procedure. Consequently, we propose and have developed an intraoperative guidance system using three-dimensional (3D) US and an instrumented mechanical arm to provide intraoperative 3D imaging and needle template tracking. METHODS: A mechatronic 3D US scanner reconstructs a 3D image from 150 2D images. A tracked mechanical arm mounted to the scanner locates four fiducial points on the template, registering the template to the 3D image. 3D reconstruction was validated for linear and volumetric measurement accuracy using phantoms of known geometry. In vivo breast US image quality was evaluated in a healthy volunteer. The encoded arm was calibrated and validated using a jig with divots at known locations relative to the scanner and the scanner registered to the 3D US image using intersecting strings in a fluid-filled test jig. Template registration accuracy was assessed using a machined test jig. Tracking accuracy was assessed in a liquid medium by comparing tracked and imaged needle tip positions. Finally, the system was used to guide a mock procedure in a patient-specific phantom and micro-CT imaging used to evaluate its accuracy. RESULTS: Geometric validation showed median distances within ±1.1% of expected values and volumetric validation showed differences of ≤4.1%. Tracking arm point measurements showed an average error of 0.43 mm and 3D US volume registration showed target registration error ≤0.9 mm. Mean template registration accuracy in each axis of translation/rotation was ≤1.3 mm/1.0°. Mean needle-targeting error was 2.5 mm and 1.6° for needle tips and trajectories, respectively. Mean needle tip and angular errors of the phantom procedure were 2.1 mm and 2.6°. Modeled seed displacement of the phantom procedure showed mean error of 2.6 mm and a maximum of 3.8 mm. CONCLUSIONS: A 3D US guidance system for PBSI has been developed. Benchtop performance and image quality in volunteer scans are satisfactory. A phantom PBSI procedure was successfully delivered using the system with maximum seed error within dosimetric benchmarks (<5 mm). Translation of the device into the clinic is forthcoming.

20.
Brachytherapy ; 16(1): 167-173, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-27771242

RESUMEN

PURPOSE: Planning permanent breast seed implant (PBSI) brachytherapy using CT alone may reduce treatment accuracy because of differences in seroma visualization compared with ultrasound (US). This study evaluates dosimetric effects of seroma delineation in PBSI and the potential impact of incorporating three-dimensional (3D) US into PBSI treatment planning. METHODS AND MATERIALS: Spatially coregistered CT and 3D US images from 10 patients were retrospectively analyzed to simulate the PBSI procedure. Seromas contoured on CT and US defined clinical target volumes, CTVCT and CTVUS, which were expanded to create planning target volumes (PTVs). PBSI plans were generated using PTVCT alone, and the resulting coverage to PTVUS was evaluated. To assess the potential impact of transferring to an US-guided procedure, the CT-based plans were centered on CTVUS. The volume encompassed by both PTVs was used to evaluate how 3D US can affect the planning procedure. RESULTS: Median (range) PTVCTV100 was 95.6% (93.3-97.3%), resulting in PTVUS coverage of 91.5% (80.5-97.9%). Centering plans on CTVUS decreased PTVCTV100 by a mean of 10 ± 8%, and increased PTVUSV100 by 5 ± 4%. The combined PTVs were a mean 9±6% larger than PTVCT. Acceptable dosimetry to the combined PTVs resulted in sufficient coverage to individual PTVs but with a mean 11 ± 24% increase to skin dose and 6 ± 8% increase in breast V200. CONCLUSIONS: Differences in seroma visualization have dosimetric effects in PBSI. CT-based plans can underdose US-defined volumes and may not adequately translate to an US-guided procedure. Implementing 3D US into planning can potentially compensate for differences in delineation.


Asunto(s)
Braquiterapia/métodos , Neoplasias de la Mama/radioterapia , Complicaciones Posoperatorias/diagnóstico por imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Seroma/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Ultrasonografía , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Humanos , Imagenología Tridimensional , Radiometría , Dosificación Radioterapéutica , Radioterapia Adyuvante , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA