Am J Crit Care ; 31(5): 355-365, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-36045046

RESUMEN

BACKGROUND: Respiratory rate (RR) alarms alert clinicians to a change in a patient's condition. However, RR alarms are common occurrences. To date, no study has examined RR alarm types and associated patient characteristics, which could guide alarm management strategies. OBJECTIVES: To characterize RR alarms by type, frequency, duration, and associated patient demographic and clinical characteristics. METHODS: A secondary data analysis of alarms generated with impedance pneumography in 461 adult patients admitted to either a cardiac, a medical/surgical, or a neurological intensive care unit (ICU). The RR alarms included high parameter limit (≥30 breaths/min), low parameter limit (≤5 breaths/min), and apnea (no breathing ≥20 s). The ICU type; total time monitored; and alarm type, frequency, and duration were evaluated. RESULTS: Of 159 771 RR alarms, parameter limit alarms (n = 140 975; 88.2%) were more frequent than apnea alarms (n = 18 796; 11.8%). High parameter limit alarms were most frequent (n = 131 827; 82.5%). After ICU monitoring time was controlled for, multivariate analysis showed that alarm rates were higher in patients in the cardiac and neurological ICUs (P = .001), patients undergoing mechanical ventilation (P = .005), and patients without a ventricular assist device or pacemaker (P = .02). Male sex was associated with low parameter limit (P = .01) and apnea (P = .005) alarms. CONCLUSION: High parameter limit RR alarms were most frequent. Factors associated with RR alarms included monitoring time, ICU type, male sex, and mechanical ventilation. Although these factors are not modifiable, these data could be used to guide management strategies.


Asunto(s)
Alarmas Clínicas , Frecuencia Respiratoria , Adulto , Apnea , Impedancia Eléctrica , Humanos , Masculino , Monitoreo Fisiológico
2.
J Electrocardiol ; 71: 16-24, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35007832

RESUMEN

BACKGROUND: Impedance pneumography (IP) is the current device-driven method used to measure respiratory rate (RR) in hospitalized patients. However, RR alarms are common and contribute to alarm fatigue. While RR derived from electrocardiographic (ECG) waveforms hold promise, they have not been compared to the IP method. PURPOSE: Study examined the agreement between the IP and combined-ECG derived (EDR) for normal RR (≥12 or ≤20 breaths/minute [bpm]); low RR (≤5 bpm); and high RR (≥30 bpm). METHODOLOGY: One-hundred intensive care unit patients were included by RR group: (1) normal RR (n = 50; 25 low RR and 25 high RR); (2) low RR (n = 50); and (3) high RR (n = 50). Bland-Altman analysis was used to evaluate agreement. RESULTS: For normal RR, a significant bias difference of -1.00 + 2.11 (95% CI -1.60 to -0.40) and 95% limit of agreement (LOA) of -5.13 to 3.13 was found. For low RR, a significant bias difference of -16.54 + 6.02 (95% CI: -18.25 to -14.83) and a 95% LOA of -28.33 to - 4.75 was found. For high RR, a significant bias difference of 17.94 + 12.01 (95% CI: 14.53 to 21.35) and 95% LOA of -5.60 to 41.48 was found. CONCLUSION: Combined-EDR method had good agreement with the IP method for normal RR. However, for the low RR, combined-EDR was consistently higher than the IP method and almost always lower for the high RR, which could reduce the number of RR alarms. However, replication in a larger sample including confirmation with visual assessment is warranted.


Asunto(s)
Electrocardiografía , Frecuencia Respiratoria , Impedancia Eléctrica , Electrocardiografía/métodos , Humanos , Monitoreo Fisiológico
3.
Ann Noninvasive Electrocardiol ; 26(5): e12885, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34405488

RESUMEN

BACKGROUND: Respiratory rate (RR) is one of the most important indicators of a patient's health. In critically ill patients, unrecognized changes in RR are associated with poorer outcomes. Visual assessment (VA), impedance pneumography (IP), and electrocardiographic-derived respiration (EDR) are the three most commonly used methods to assess RR. While VA and IP are widely used in hospitals, the EDR method has not been validated for use in hospitalized patients. Additionally, little is known about their accuracy compared with one another. The purpose of this systematic review was to compare the accuracy, strengths, and limitations of VA of RR to two methods that use physiologic data, namely IP and EDR. METHODS: A systematic review of the literature was undertaken using prespecified inclusion and exclusion criteria. Each of the studies was evaluated using standardized criteria. RESULTS: Full manuscripts for 23 studies were reviewed, and four studies were included in this review. Three studies compared VA to IP and one study compared VA to EDR. In terms of accuracy, when Bland-Altman analyses were performed, the upper and lower levels of agreement were extremely poor for both the VA and IP and VA and EDR comparisons. CONCLUSION: Given the paucity of research and the fact that no studies have compared all three methods, no definitive conclusions can be drawn about the accuracy of these three methods. The clinical importance of accurate assessment of RR warrants new research with rigorous designs to determine the accuracy, and clinically meaningful levels of agreement of these methods.


Asunto(s)
Electrocardiografía , Frecuencia Respiratoria , Impedancia Eléctrica , Humanos , Respiración