Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Micromachines (Basel) ; 14(3)2023 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-36985107

RESUMEN

Photolithographic patterning of components and integrated circuits based on active polymers for microfluidics is challenging and not always efficient on a laboratory scale using the traditional mask-based fabrication procedures. Here, we present an alternative manufacturing process based on multi-material 3D printing that can be used to print various active polymers in microfluidic structures that act as microvalves on large-area substrates efficiently in terms of processing time and consumption of active materials with a single machine. Based on the examples of two chemofluidic valve types, hydrogel-based closing valves and PEG-based opening valves, the respective printing procedures, essential influencing variables and special features are discussed, and the components are characterized with regard to their properties and tolerances. The functionality of the concept is demonstrated by a specific chemofluidic chip which automates an analysis procedure typical of clinical chemistry and laboratory medicine. Multi-material 3D printing allows active-material devices to be produced on chip substrates with tolerances comparable to photolithography but is faster and very flexible for small quantities of up to about 50 chips.

2.
ACS Appl Mater Interfaces ; 13(41): 49433-49444, 2021 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-34612033

RESUMEN

Multienzymatic cascade reactions are a powerful strategy for straightforward and highly specific synthesis of complex materials, such as active substances in drugs. Cross-inhibitions and incompatible reaction steps, however, often limit enzymatic activity and thus the conversion. Such limitations occur, e.g., in the enzymatic synthesis of the biologically active sialic acid cytidine monophosphate N-acetylneuraminic acid (CMP-Neu5Ac). We addressed this challenge by developing a confinement and compartmentalization concept of hydrogel-immobilized enzymes for improving the efficiency of the enzyme cascade reaction. The three enzymes required for the synthesis of CMP-Neu5Ac, namely, N-acyl-d-glucosamine 2-epimerase (AGE), N-acetylneuraminate lyase (NAL), and CMP-sialic acid synthetase (CSS), were immobilized into bulk hydrogels and microstructured hydrogel-enzyme-dot arrays, which were then integrated into microfluidic devices. To overcome the cytidine triphosphate (CTP) cross-inhibition of AGE and NAL, only a low CTP concentration was applied and continuously conveyed through the device. In a second approach, the enzymes were compartmentalized in separate reaction chambers of the microfluidic device to completely avoid cross-inhibitions and enable the use of higher substrate concentrations. Immobilization efficiencies of up to 25% and pronounced long-term activity of the immobilized enzymes for several weeks were realized. Moreover, immobilized enzymes were less sensitive to inhibition and the substrate-channeling effect between immobilized enzymes promoted the overall conversion in the trienzymatic cascade reaction. Based on this, CMP-Neu5Ac was successfully synthesized by immobilized enzymes in noncompartmentalized and compartmentalized microfluidic devices. This study demonstrates the high potential of immobilizing enzymes in (compartmentalized) microfluidic devices to perform multienzymatic cascade reactions despite cross-inhibitions under continuous flow conditions. Due to the ease of enzyme immobilization in hydrogels, this concept is likely applicable for many cascade reactions with or without cross-inhibition characteristics.


Asunto(s)
Citidina Monofosfato/análogos & derivados , Enzimas Inmovilizadas/química , Hidrogeles/química , Ácidos Siálicos/síntesis química , Carbohidrato Epimerasas/química , Proteínas Portadoras/química , Citidina Monofosfato/síntesis química , Dispositivos Laboratorio en un Chip , Microfluídica/instrumentación , Microfluídica/métodos , N-Acilneuraminato Citidililtransferasa/química , Oxo-Ácido-Liasas/química , Polietilenglicoles/química
3.
Front Vet Sci ; 7: 570, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33110913

RESUMEN

This study was conducted to investigate the therapeutic effect of allogeneic adipose-derived MSCs on dogs with hip osteoarthritis (OA). Twenty dogs with bilateral osteoarthritis of the coxofemoral (hip) joint, diagnosed by a veterinarian through physical examination and radiographs were randomly allocated into four groups. Group 1 served as a placebo control and were injected with 0.9% sodium chloride (saline) (n = 4). Group 2 were injected with a single dose of 5 million MSCs (n = 5). Group 3 received a single dose of 25 million MSCs (n = 6) and Group 4 received a single dose of 50 million MSCs (n = 5). Intra-articular administration of allogeneic MSCs into multiple joints did not result in any serious adverse events. The average lameness score of the dogs in the placebo control group (-0.31) did not show improvement after 90 days of intra-articular saline administration. However, the average lameness score of the all MSC-treated dogs was improved 2.11 grade at this time point (P < 0.001). Overall, sixty five percent (65%) of the dogs that received various doses of MSCs showed improvement in lameness scores 90 days after intra-articular MSC administration. Our results showed that intra-articular administration of allogeneic adipose derived MSCs was well-tolerated and improved lameness scores and reduced pain in dogs associated with hip OA. All doses of MSCs were effective. Subsequent studies with more animals per group are needed to make a conclusion about the dose response. The improved lameness effect was present up to 90 days post-injection. Serum interleukin 10 was increased in a majority of the dogs that received MSCs and that also had improved lameness.

4.
Micromachines (Basel) ; 11(5)2020 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-32370256

RESUMEN

The interest in large-scale integrated (LSI) microfluidic systems that perform high-throughput biological and chemical laboratory investigations on a single chip is steadily growing. Such highly integrated Labs-on-a-Chip (LoC) provide fast analysis, high functionality, outstanding reproducibility at low cost per sample, and small demand of reagents. One LoC platform technology capable of LSI relies on specific intrinsically active polymers, the so-called stimuli-responsive hydrogels. Analogous to microelectronics, the active components of the chips can be realized by photolithographic micro-patterning of functional layers. The miniaturization potential and the integration degree of the microfluidic circuits depend on the capability of the photolithographic process to pattern hydrogel layers with high resolution, and they typically require expensive cleanroom equipment. Here, we propose, compare, and discuss a cost-efficient do-it-yourself (DIY) photolithographic set-up suitable to micro-pattern hydrogel-layers with a resolution as needed for very large-scale integrated (VLSI) microfluidics. The achievable structure dimensions are in the lower micrometer scale, down to a feature size of 20 µm with aspect ratios of 1:5 and maximum integration densities of 20,000 hydrogel patterns per cm². Furthermore, we demonstrate the effects of miniaturization on the efficiency of a hydrogel-based microreactor system by increasing the surface area to volume (SA:V) ratio of integrated bioactive hydrogels. We then determine and discuss a correlation between ultraviolet (UV) exposure time, cross-linking density of polymers, and the degree of immobilization of bioactive components.

5.
Micromachines (Basel) ; 11(2)2020 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-32033413

RESUMEN

Compartmentalized microfluidic devices with immobilized catalysts are a valuable tool for overcoming the incompatibility challenge in (bio) catalytic cascade reactions and high-throughput screening of multiple reaction parameters. To achieve flow control in microfluidics, stimuli-responsive hydrogel microvalves were previously introduced. However, an application of this valve concept for the control of multistep reactions was not yet shown. To fill this gap, we show the integration of thermoresponsive poly(N-isopropylacrylamide) (PNiPAAm) microvalves (diameter: 500 and 600 µm) into PDMS-on-glass microfluidic devices for the control of parallelized enzyme-catalyzed cascade reactions. As a proof-of-principle, the biocatalysts glucose oxidase (GOx), horseradish peroxidase (HRP) and myoglobin (Myo) were immobilized in photopatterned hydrogel dot arrays (diameter of the dots: 350 µm, amount of enzymes: 0.13-2.3 µg) within three compartments of the device. Switching of the microvalves was achieved within 4 to 6 s and thereby the fluid pathway of the enzyme substrate solution (5 mmol/L) in the device was determined. Consequently, either the enzyme cascade reaction GOx-HRP or GOx-Myo was performed and continuously quantified by ultraviolet-visible (UV-Vis) spectroscopy. The functionality of the microvalves was shown in four hourly switching cycles and visualized by the path-dependent substrate conversion.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...