Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Circ Heart Fail ; 14(1): e007448, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33464953

RESUMEN

BACKGROUND: Continuous-flow (CF) left ventricular assist devices (LVADs) improve outcomes for patients with advanced heart failure (HF). However, the lack of a physiological pulse predisposes to side-effects including uncontrolled blood pressure (BP), and there are little data regarding the impact of CF-LVADs on BP regulation. METHODS: Twelve patients (10 males, 60±11 years) with advanced heart failure completed hemodynamic assessment 2.7±4.1 months before, and 4.3±1.3 months following CF-LVAD implantation. Heart rate and systolic BP via arterial catheterization were monitored during Valsalva maneuver, spontaneous breathing, and a 0.05 Hz repetitive squat-stand maneuver to characterize cardiac baroreceptor sensitivity. Plasma norepinephrine levels were assessed during head-up tilt at supine, 30o and 60o. Heart rate and BP were monitored during cardiopulmonary exercise testing. RESULTS: Cardiac baroreceptor sensitivity, determined by Valsalva as well as Fourier transformation and transfer function gain of Heart rate and systolic BP during spontaneous breathing and squat-stand maneuver, was impaired before and following LVAD implantation. Norepinephrine levels were markedly elevated pre-LVAD and improved-but remained elevated post-LVAD (supine norepinephrine pre-LVAD versus post-LVAD: 654±437 versus 323±164 pg/mL). BP increased during cardiopulmonary exercise testing post-LVAD, but the magnitude of change was modest and comparable to the changes observed during the pre-LVAD cardiopulmonary exercise testing. CONCLUSIONS: Among patients with advanced heart failure with reduced ejection fraction, CF-LVAD implantation is associated with modest improvements in autonomic tone, but persistent reductions in cardiac baroreceptor sensitivity. Exercise-induced increases in BP are blunted. These findings shed new light on mechanisms for adverse events such as stroke, and persistent reductions in functional capacity, among patients supported by CF-LVADs. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03078972.


Asunto(s)
Barorreflejo/fisiología , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Presorreceptores/fisiopatología , Anciano , Presión Sanguínea/fisiología , Prueba de Esfuerzo , Femenino , Insuficiencia Cardíaca/fisiopatología , Frecuencia Cardíaca/fisiología , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Norepinefrina/sangre , Maniobra de Valsalva/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...