Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 24(11)2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38894116

RESUMEN

BACKGROUND: Robotic devices are known to provide pivotal parameters to assess motor functions in Multiple Sclerosis (MS) as dynamic balance. However, there is still a lack of validation studies comparing innovative technologies with standard solutions. Thus, this study's aim was to compare the postural assessment of fifty people with MS (PwMS) during dynamic tasks performed with the gold standard EquiTest® and the robotic platform hunova®, using Center of Pressure (COP)-related parameters and global balance indexes. METHODS: Pearson's ρ correlations were run for each COP-related measure and the global balance index was computed from EquiTest® and hunova® in both open (EO) and closed-eyes (EC) conditions. RESULTS: Considering COP-related parameters, all correlations were significant in both EO (0.337 ≤ ρ ≤ 0.653) and EC (0.344 ≤ ρ ≤ 0.668). Furthermore, Pearson's analysis of global balance indexes revealed relatively strong for visual and vestibular, and strong for somatosensory system associations (ρ = 0.573; ρ = 0.494; ρ = 0.710, respectively). CONCLUSIONS: Findings confirm the use of hunova® as a valid device for dynamic balance assessment in MS, suggesting that such a robotic platform could allow for a more sensitive assessment of balance over time, and thus a better evaluation of the effectiveness of personalized treatment, thereby improving evidence-based clinical practice.


Asunto(s)
Esclerosis Múltiple , Equilibrio Postural , Robótica , Humanos , Esclerosis Múltiple/fisiopatología , Equilibrio Postural/fisiología , Masculino , Robótica/instrumentación , Robótica/métodos , Femenino , Adulto , Persona de Mediana Edad , Dispositivos de Autoayuda
2.
Eur J Med Res ; 28(1): 254, 2023 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-37491303

RESUMEN

INTRODUCTION: Balance disorders are common in people with Multiple Sclerosis (PwMS) and, together with other impairments and disabilities, often prevent PwMS from performing their daily living activities. Besides clinical scales and performance tests, robotic platforms can provide more sensitive, specific, and objective monitoring. Validated technologies have been adopted as gold standard, but innovative robotic solutions would represent an opportunity to detect balance impairment in PwMS. AIM: Study's aim was to compare postural assessment of 46 PwMS with a relapsing-remitting form during static tasks performed with the novel robotic platform hunova® and the gold standard EquiTest®, METHODS: Pearson's r was run on Center of Pressure (COP)-related parameters and global static balance measures computed from hunova® and EquiTest® in eyes-open (EO) and eyes-closed (EC) conditions. In addition, agreeableness level toward the use of both devices was tested through numeric rating scale. RESULTS: Considering COP-related parameters, correlations were significant for all measures (p < .001). Interestingly, in EO, a strong correlation was shown for sway area (r = .770), while Medio-Lateral (ML) and Anterior-Posterior (AP) oscillation range, path length, ML and AP speed, ML and AP root mean square distance had a relatively strong association (.454 ≤ r ≤ .576). In EC, except for ML oscillation range showing a relatively strong correlation (r = .532), other parameters were strongly associated (.603 ≤ r ≤ .782). Correlations between global balance indexes of hunova® and EquiTest® revealed a relatively strong association between the Somatosensory Score in EquiTest® and the Somatosensory Index in hunova® (r = - .488). While in EO Static Balance Index from hunova® was highly correlated with Equilibrium score of EquiTest® (r = .416), Static Balance Index had a relatively strong association with both the Equilibrium (r = .482) and Strategy Score (r = .583) of EquiTest® in EC. Results from agreeableness rating scale revealed that hunova® was highly appreciated compared to EquiTest® (p = .044). CONCLUSIONS: hunova® represents an innovative adjunct to standard robotic balance evaluation for PwMS. This confirms that combining traditional and robotic assessments can more accurately detect balance impairments in MS.


Asunto(s)
Esclerosis Múltiple , Procedimientos Quirúrgicos Robotizados , Humanos , Equilibrio Postural , Actividades Cotidianas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...