Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Infect Dis ; 229(Supplement_2): S132-S136, 2024 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-37681583

RESUMEN

This paper describes the methods for developing and optimizing a laboratory-developed assay (LDA) for detecting clade II human mpox virus using the automated Panther Fusion platform and Open Access software. Various concentrations of reagents in a primer-probe mix were tested to optimize the LDA. The LDA was validated using 10 previously characterized positive and 10 negative human mpox samples, resulting in 95% accuracy and 100% precision. The LDA resulted in 100% specificity among previously tested HSV1-, HSV2-, and VZV-positive human samples. Several spiked media extensions were also validated and achieved 98% accuracy and 100% precision across all collection media types. The assay's limit of detection was calculated to be 1.475 copies/reaction, and the polymerase chain reaction efficiency resulted in 89.87% (slope, -3.5911; R2 = 0.9947). The methods described here can be applied to the rapid optimization and development of LDAs for many possible pathogens of public health importance.


Asunto(s)
Monkeypox virus , Virus , Humanos , Acceso a la Información , Sensibilidad y Especificidad , Reacción en Cadena de la Polimerasa
2.
J Virol Methods ; 228: 151-7, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26640122

RESUMEN

In this study, a multicenter evaluation of the Life Technologies TaqMan(®) Array Card (TAC) with 21 custom viral and bacterial respiratory assays was performed on the Applied Biosystems ViiA™ 7 Real-Time PCR System. The goal of the study was to demonstrate the analytical performance of this platform when compared to identical individual pathogen specific laboratory developed tests (LDTs) designed at the Centers for Disease Control and Prevention (CDC), equivalent LDTs provided by state public health laboratories, or to three different commercial multi-respiratory panels. CDC and Association of Public Health Laboratories (APHL) LDTs had similar analytical sensitivities for viral pathogens, while several of the bacterial pathogen APHL LDTs demonstrated sensitivities one log higher than the corresponding CDC LDT. When compared to CDC LDTs, TAC assays were generally one to two logs less sensitive depending on the site performing the analysis. Finally, TAC assays were generally more sensitive than their counterparts in three different commercial multi-respiratory panels. TAC technology allows users to spot customized assays and design TAC layout, simplify assay setup, conserve specimen, dramatically reduce contamination potential, and as demonstrated in this study, analyze multiple samples in parallel with good reproducibility between instruments and operators.


Asunto(s)
Análisis de Secuencia por Matrices de Oligonucleótidos/normas , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/normas , Bacterias/genética , Bacterias/aislamiento & purificación , Centers for Disease Control and Prevention, U.S. , Humanos , Microfluídica/métodos , Microfluídica/normas , Reacción en Cadena en Tiempo Real de la Polimerasa/instrumentación , Reproducibilidad de los Resultados , Infecciones del Sistema Respiratorio/diagnóstico , Infecciones del Sistema Respiratorio/microbiología , Infecciones del Sistema Respiratorio/virología , Sensibilidad y Especificidad , Estados Unidos , Virus/genética , Virus/aislamiento & purificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...