Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros












Intervalo de año de publicación
3.
Einstein (Sao Paulo) ; 18: eAO4966, 2020.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-31994605

RESUMEN

OBJECTIVE: To validate multilineage score system correlating results of flow cytometry, cytogenetics, cytomorphology and histology from samples of patients with suspected myelodysplastic syndrome or cytopenia of unknown origin. METHODS: A retrospective study analyzing laboratory data of 49 patients with suspected myelodysplastic syndrome or cytopenia of unknown origin, carried out between May and September 2017. The inclusion criteria were availability of flow cytometry results, and at least one more method, such as morphology, histology or cytogenetics. Thirty-eight patients were classified as diagnosis of myelodysplastic syndromes, whereas 11 were classified as normal. Patients were evaluated based on score systems, Ogata score and flow cytometry multilineage score. RESULTS: Comparing the scores obtained in the Ogata score and the multilineage score, it was observed that in four cases the Ogata score was zero or 1 point, while the multilineage score was higher than 3 points. In addition, in 12 cases with Ogata score of 2, the multilineage score was greater than 3. CONCLUSION: The flow cytometry multilineage score system demonstrated to be more effective in dysplasia analysis, by assessing the erythroid, monocytic, granulocytic and precursor cell lineages, apart from the parameters evaluated by the Ogata score.


Asunto(s)
Citometría de Flujo/normas , Síndromes Mielodisplásicos/patología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Biopsia , Células de la Médula Ósea/patología , Niño , Preescolar , Análisis Citogenético/métodos , Análisis Citogenético/normas , Células Eritroides/patología , Femenino , Citometría de Flujo/métodos , Granulocitos/patología , Humanos , Lactante , Masculino , Persona de Mediana Edad , Monocitos/patología , Estándares de Referencia , Reproducibilidad de los Resultados , Estudios Retrospectivos , Adulto Joven
4.
Einstein (Säo Paulo) ; 18: eAO4966, 2020. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1056043

RESUMEN

ABSTRACT Objective To validate multilineage score system correlating results of flow cytometry, cytogenetics, cytomorphology and histology from samples of patients with suspected myelodysplastic syndrome or cytopenia of unknown origin. Methods A retrospective study analyzing laboratory data of 49 patients with suspected myelodysplastic syndrome or cytopenia of unknown origin, carried out between May and September 2017. The inclusion criteria were availability of flow cytometry results, and at least one more method, such as morphology, histology or cytogenetics. Thirty-eight patients were classified as diagnosis of myelodysplastic syndromes, whereas 11 were classified as normal. Patients were evaluated based on score systems, Ogata score and flow cytometry multilineage score. Results Comparing the scores obtained in the Ogata score and the multilineage score, it was observed that in four cases the Ogata score was zero or 1 point, while the multilineage score was higher than 3 points. In addition, in 12 cases with Ogata score of 2, the multilineage score was greater than 3. Conclusion The flow cytometry multilineage score system demonstrated to be more effective in dysplasia analysis, by assessing the erythroid, monocytic, granulocytic and precursor cell lineages, apart from the parameters evaluated by the Ogata score.


RESUMO Objetivo Validar ficha de escore multilinhagem correlacionando resultados obtidos de citometria de fluxo, citogenética, citomorfologia e histologia de amostras de pacientes com suspeita de síndrome mielodisplásica ou citopenias a esclarecer. Métodos Estudo retrospectivo de análise de dados laboratoriais de 49 pacientes com suspeita clínica de síndrome mielodisplásica ou citopenias a esclarecer realizado entre maio e setembro de 2017. Os critérios de inclusão foram a disponibilidade de resultados de citometria de fluxo e de, pelo menos, outra metodologia, entre morfologia, histologia, ou citogenética. Trinta e oito pacientes foram classificados como diagnosticados com síndromes mielodisplásicas enquanto 11 foram classificados como normais. Os pacientes foram avaliados utilizando sistemas de escore, escore de Ogata e ficha multilinhagem. Resultados Comparando as pontuações obtidas no escore de Ogata e na ficha multilinhagem, observou-se que, em quatro casos, o score de Ogata foi zero ou 1 ponto, enquanto, pela ficha multilinhagem, a pontuação foi superior a 3 pontos. Além disso, em 12 casos com escore de Ogata 2, a pontuação pela ficha multilinhagem foi superior a 3. Conclusão A ficha multilinhagem demonstrou ser mais eficaz na análise de displasia por avaliar as linhagens eritroide, monocítica, granulocítica e células precursoras, além dos parâmetros avaliados no escore de Ogata.


Asunto(s)
Humanos , Masculino , Femenino , Lactante , Preescolar , Niño , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Adulto Joven , Síndromes Mielodisplásicos/patología , Citometría de Flujo/normas , Estándares de Referencia , Biopsia , Células de la Médula Ósea/patología , Monocitos/patología , Reproducibilidad de los Resultados , Estudios Retrospectivos , Análisis Citogenético/métodos , Análisis Citogenético/normas , Células Eritroides/patología , Citometría de Flujo/métodos , Granulocitos/patología , Persona de Mediana Edad
5.
Front Med (Lausanne) ; 5: 70, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29876349

RESUMEN

INTRODUCTION: Infiltration of the central nervous system (CNS) by hematologic or lymphoid malignant cells can cause extensive neurological damage, be progressive and fatal. However, usually, the cerebrospinal fluid (CSF) has low cellularity and rapid cell degeneration, which can impair cytometry analysis. Storage and transport measures, sample preparation, and staining protocols can interfere with diagnostic accuracy. OBJECTIVE: To calculate the diagnostic performance of flow cytometry (FC) using a cell stabilizer for sample preservation compared to cytomorphology in the detection of CNS infiltration by lymphoid and hematologic neoplasms. METHODS: Cell samples from all consecutive patients with suspected infiltration by hematological malignancies evaluated between January 2014 and December 2016 were included. Cases were analyzed by FC using a cell preservation medium and cytomorphology. Sensitivity and specificity were calculated. RESULTS: From 414 CSF samples, 72 had a phenotype compatible with characteristics of infiltration by hematological disease, whereas cytology was positive for 35 cases. FC showed higher sensitivity and specificity when compared to cytomorphology, particularly in cases with cellularity under 5 leukocytes/mm3. CONCLUSION: We demonstrated that collecting CSF in a medium that preserves the stability of the sample improves accuracy when compared to cytomorphology, particularly in low-volume and low-cellularity samples.

6.
Front Oncol ; 7: 270, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29188193

RESUMEN

Myelodysplastic syndromes (MDSs) are a heterogeneous group of hematopoietic stem cell diseases categorized by dysplasia in one or more hematopoietic cell lineages, as well as cytopenia and functional abnormalities in bone marrow cells. Several MDS classification methods have been proposed to categorize the disease and help professionals better plan in patients' treatment. The World Health Organization classification, released in 2008 and revised in 2016, is the currently and the most used classification method worldwide. Recent advances in MDS molecular biology and innovations in flow cytometry have enabled the development of new parameters for MDS diagnosis and classification. Several groups have published flow cytometry scores and guidelines useful for the diagnosis and/or prognosis of MDS, which are mostly based on detecting immunophenotypic abnormalities in granulocyte, monocyte, and lymphoid lineages. Here, we review the current literature and discuss the main parameters that should be analyzed by flow cytometry with the aim of refining MDS diagnosis and prognosis. Furthermore, we discuss the critical role of flow cytometry and molecular biology in MDS diagnosis and prognosis, as well as the current challenges and future perspectives involving these techniques.

7.
Einstein (Sao Paulo) ; 14(3): 366-373, 2016.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-27759825

RESUMEN

OBJECTIVE:: To discuss the implementation of technical advances in laboratory diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria for validation of high-sensitivity flow cytometry protocols. METHODS:: A retrospective study based on analysis of laboratory data from 745 patient samples submitted to flow cytometry for diagnosis and/or monitoring of paroxysmal nocturnal hemoglobinuria. RESULTS:: Implementation of technical advances reduced test costs and improved flow cytometry resolution for paroxysmal nocturnal hemoglobinuria clone detection. CONCLUSION:: High-sensitivity flow cytometry allowed more sensitive determination of paroxysmal nocturnal hemoglobinuria clone type and size, particularly in samples with small clones. OBJETIVO:: Discutir as melhorias técnicas no diagnóstico e no acompanhamento laboratorial de hemoglobinúria paroxística noturna para a validação da técnica de citometria de fluxo de alta sensibilidade. MÉTODOS:: Estudo retrospectivo, que envolveu a análise de dados laboratoriais de 745 pacientes com hipótese diagnóstica e/ou acompanhamento de hemoglobinúria paroxística noturna por citometria de fluxo. RESULTADOS:: Os avanços técnicos não só reduziram o custo do ensaio, mas também melhoraram a identificação e a resolução da citometria de fluxo para a detecção de clone hemoglobinúria paroxística noturna. CONCLUSÃO:: A citometria de fluxo de alta sensibilidade possibilitou a identificação do tipo e do tamanho de clone de hemoglobinúria paroxística noturna, especialmente em amostras com pequeno clone.


Asunto(s)
Citometría de Flujo/métodos , Hemoglobinuria Paroxística/diagnóstico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Anticuerpos Monoclonales/sangre , Antígenos CD/sangre , Niño , Preescolar , Femenino , Citometría de Flujo/economía , Citometría de Flujo/instrumentación , Citometría de Flujo/normas , Hemoglobinuria Paroxística/sangre , Humanos , Lactante , Persona de Mediana Edad , Mejoramiento de la Calidad/economía , Estudios Retrospectivos , Sensibilidad y Especificidad , Adulto Joven
8.
Einstein (Säo Paulo) ; 14(3): 366-373, July-Sept. 2016. tab, graf
Artículo en Inglés | LILACS | ID: lil-796970

RESUMEN

ABSTRACT Objective: To discuss the implementation of technical advances in laboratory diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria for validation of high-sensitivity flow cytometry protocols. Methods: A retrospective study based on analysis of laboratory data from 745 patient samples submitted to flow cytometry for diagnosis and/or monitoring of paroxysmal nocturnal hemoglobinuria. Results: Implementation of technical advances reduced test costs and improved flow cytometry resolution for paroxysmal nocturnal hemoglobinuria clone detection. Conclusion: High-sensitivity flow cytometry allowed more sensitive determination of paroxysmal nocturnal hemoglobinuria clone type and size, particularly in samples with small clones.


RESUMO Objetivo: Discutir as melhorias técnicas no diagnóstico e no acompanhamento laboratorial de hemoglobinúria paroxística noturna para a validação da técnica de citometria de fluxo de alta sensibilidade. Métodos: Estudo retrospectivo, que envolveu a análise de dados laboratoriais de 745 pacientes com hipótese diagnóstica e/ou acompanhamento de hemoglobinúria paroxística noturna por citometria de fluxo. Resultados: Os avanços técnicos não só reduziram o custo do ensaio, mas também melhoraram a identificação e a resolução da citometria de fluxo para a detecção de clone hemoglobinúria paroxística noturna. Conclusão: A citometria de fluxo de alta sensibilidade possibilitou a identificação do tipo e do tamanho de clone de hemoglobinúria paroxística noturna, especialmente em amostras com pequeno clone.


Asunto(s)
Humanos , Femenino , Lactante , Preescolar , Niño , Adolescente , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Adulto Joven , Citometría de Flujo/métodos , Hemoglobinuria Paroxística/diagnóstico , Antígenos CD/sangre , Estudios Retrospectivos , Sensibilidad y Especificidad , Mejoramiento de la Calidad/economía , Citometría de Flujo/economía , Citometría de Flujo/instrumentación , Citometría de Flujo/normas , Hemoglobinuria Paroxística/sangre , Anticuerpos Monoclonales/sangre
9.
J. bras. patol. med. lab ; 47(3): 217-223, jun. 2011. tab
Artículo en Portugués | LILACS | ID: lil-600861

RESUMEN

A água é um reagente utilizado na maioria dos testes laboratoriais e por isso deve seguir um padrão de controle de qualidade rigoroso. O fornecimento urbano de água apresenta moléculas orgânicas, íons inorgânicos, partículas, coloides, gases, bactérias e seus produtos, que podem alterar os resultados dos exames laboratoriais e causar eventuais erros e falhas mecânicas em equipamentos analíticos. Para remover essas impurezas, é necessário recorrer a uma combinação de tecnologias de purificação. Há várias organizações que especificam normas sobre a água reagente, a fim de minimizar sua interferência nos ensaios laboratoriais. A maioria dos laboratórios utiliza as normas estabelecidas pelo Clinical and Laboratory Standards Institute (CLSI) que classifica a água em: clinical laboratory reagent water (CLRW), special reagent water (SRW) e instrumental feed water (IFW). O monitoramento da qualidade é realizado pela determinação de resistividade, condutividade, carbono orgânico total (TOC), controle microbiológico e endotoxinas. Os parâmetros são avaliados de acordo com a periodicidade estabelecida pela norma utilizada. Neste artigo, discutem-se a importância da água utilizada nos procedimentos laboratoriais, o controle da qualidade e as interferências nos ensaios laboratoriais.


Water is a reagent used in most laboratory tests and, therefore, must follow stringent quality control standards. The urban water supply has organic molecules, inorganic ions, particles, colloids, gases, bacteria and their products, which may alter laboratory test results and cause occasional errors and mechanical failures in diagnostic equipment. To remove these impurities, it is necessary to use a combination of purification technologies. There are several organizations that specify reagent water standards to minimize its interference in laboratory assays. Most laboratories set standards established by the Clinical and Laboratory Standards Institute (CLSI), which classifies the type of water as follows: clinical laboratory reagent water (CLRW), special reagent water (SRW) and instrumental feed water (IFW). The quality monitoring is performed by means of assessing the resistivity, conductivity, total organic carbon (TOC), microbial control and endotoxins. The parameters are evaluated in accordance with the frequency determined by the standard used. In this article we discuss the importance of water employed in laboratory procedures, its quality control and its interference in laboratory assays.


Asunto(s)
Biomarcadores Ambientales , Técnicas de Laboratorio Clínico , Laboratorios , Purificación del Agua/métodos , Control de Calidad , Contaminación del Agua , Calidad del Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...