Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Thorac Cardiovasc Surg ; 52(5): 280-6, 2004 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-15470609

RESUMEN

BACKGROUND: Use of additional sources of pulmonary blood flow (APBF) with bidirectional cavopulmonary anastomosis (BDG) and total cavopulmonary connection (TCPC) remains controversial. We have therefore assessed the effects of APBF on BDG and TCPC outcome. METHODS: From 1996 to 2000, 106 patients underwent BDG, either isolated (group 1, n = 54), or with APBF via pulmonary artery (PA) (group 2, n = 30), or Blalock-Taussig shunt (BTS) (group 3, n = 22) with 28 patients completed by TCPC. RESULTS: After BDG low output syndrome was more frequent in group 2 and less in 3 ( p = 0.01), whereas superior cava syndrome was again more common in group 2 and less in groups 1 and 3 ( p < 0.05) than expected. Mortality and complications were similar after TCPC in all groups. Oxygen saturation (SaO (2)) was lower without than with APBF ( p < 0.002) after BDG and in group 3 than in group 2 after TCPC ( p < 0.05). Repeated measures ANOVA showed no effect of APBF on SaO (2), PA pressures, fractional shortening, end-diastolic pressure and AV-valve function. CONCLUSIONS: Early after BDG, APBF via PA presents different difficulties than APBF via BTS. However, BDG and TCPC outcomes are not affected by the presence or absence of APBF.


Asunto(s)
Puente Cardíaco Derecho/métodos , Cardiopatías Congénitas/cirugía , Circulación Pulmonar , Adolescente , Implantación de Prótesis Vascular , Niño , Preescolar , Constricción Patológica , Ventrículos Cardíacos/anomalías , Humanos , Lactante , Oxígeno/sangre , Arteria Pulmonar/patología , Arteria Pulmonar/fisiopatología , Estudios Retrospectivos
2.
Swiss Surg ; 9(5): 247-52, 2003.
Artículo en Alemán | MEDLINE | ID: mdl-14601329

RESUMEN

BACKGROUND: The Sorin Pericarbon Freedom Stentless aortic valve has the potential to provide superior hemodynamic function and durability. In this study we assessed the hemodynamic performance of this valve and its impact on LV-mass regression after aortic valve replacement. METHODS: 31 consecutive patients who received a Sorin Pericarbon Freedom Stentless aortic valve were analysed. Mean age of the patients (16 female and 15 male) was 64 +/- 17 years. Five patients had isolated aortic stenosis, three isolated aortic regurgitation and one combined aortic valve disease. Three patients had combined aortic and mitral valve disease, 14 patients concomitant coronary artery disease, one congenital aortic coarctation. Three patients had an acute aortic valve endocarditis. 18 patients were classified as high-risk patients (mean EuroSCORE 9 +/- 2). Mean left ventricular ejection fraction was 52.5 +/- 15.0%. RESULTS: Valve sizes from 21 mm to 29 mm were implanted. The valves were oversized by 2 mm compared to measurement. 16 patients received isolated aortic valve replacement, Three patients aortic valve replacement and mitral valve reconstruction. 12 patients had concomitant CABG. Three procedures were reoperations. Hospital mortality was 6.4% (two patients). Both deaths occurred in high-risk patients and were not valve-related. Four patients had perioperative low-output-syndrome and needed IABP. After six months a follow up echocardiography was performed. Mean and peak gradients were 9.6 +/- 4.4 and 20.6 +/- 5.9 mmHg, respectively. Significant reduction of left ventricular hypertrophy (LV mass index 126.5 +/- 27.3 vs. 189.6 +/- 45.3 g/m2, p = 0.0313) and improvement of the ejection fraction (58 +/- 9.8 vs. 52.5 +/- 15.0%, p = 0.9749) as compared with preoperative valve. CONCLUSIONS: The hemodynamic performance of the Sorin Pericarbon Freedom Stentless aortic valve is excellent and the patient outcome is satisfying. However the implantation technique requires longer ischemic time, the prosthesis offers very satisfying hemodynamic function and accelerates probably the LV-mass regression in the mid term follow-up. Late performance and durability of the valve have to be assessed.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Hemodinámica/fisiología , Complicaciones Posoperatorias/fisiopatología , Anciano , Anciano de 80 o más Años , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Comorbilidad , Endocarditis Bacteriana/mortalidad , Endocarditis Bacteriana/fisiopatología , Endocarditis Bacteriana/cirugía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/mortalidad , Diseño de Prótesis , Factores de Riesgo , Stents , Tasa de Supervivencia , Suiza , Remodelación Ventricular/fisiología
3.
Eur J Cardiothorac Surg ; 22(4): 545-51, 2002 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-12297170

RESUMEN

OBJECTIVE: Effects of aprotinin in off-pump coronary artery bypass (OPCAB) surgery have not yet been described. This study analyses hemostasiologic changes and potential benefit in OPCAB patients treated with aprotinin. METHODS: In a prospective, double-blind, randomized study 47 patients undergoing OPCAB surgery were investigated. Patients received either aprotinin (2 x 10(6) KIU loading dose and 0.5 x 10(6) KIU/h during surgery, n=22) or saline solution (control, n=25). Activated clotting time was adjusted to a target of 250 s intraoperatively. Blood samples were taken up to 18h postoperatively: complete hematologic and hemostasiologic parameters including fibrinopeptide A (FPA) and D-dimer in a subgroup of 31 patients were analyzed. Blood loss, blood transfusion and other clinical data were collected. RESULTS: Both groups showed comparable demographic and intraoperative variables. Forty-one (87%) patients of the whole study group received aspirin within 7 days prior to surgery. Number of grafts per patient were comparable (2.9+/-1.0 [mean+/-SD] in the aprotinin group and 2.8+/-1.2 in control, P=0.83). Blood loss during the first 18 h in intensive care unit was significantly reduced in patients treated with aprotinin (median [25th-75th percentiles]: 500 [395-755] ml vs. 930 [800-1170] ml, P<0.001). Postoperatively only two patients (10%) in the aprotinin group received packed red blood cells, whereas eight (35%) in the control group (P=0.07). Perioperatively FPA levels reflecting thrombin generation were elevated in both groups. The increase in D-dimer levels after surgery was significantly inhibited in the aprotinin group (P<0.001). Early clinical outcome was similar in both groups. CONCLUSIONS: Aprotinin significantly reduces blood loss in patients undergoing OPCAB surgery. Inhibition of enhanced fibrinolysis can be observed. FPA generation during and after OPCAB surgery seems not to be influenced by aprotinin.


Asunto(s)
Aprotinina/uso terapéutico , Puente de Arteria Coronaria/métodos , Enfermedad Coronaria/cirugía , Hemorragia Posoperatoria/prevención & control , Inhibidores de Proteasas/uso terapéutico , Anciano , Análisis de Varianza , Distribución de Chi-Cuadrado , Enfermedad Coronaria/sangre , Método Doble Ciego , Femenino , Productos de Degradación de Fibrina-Fibrinógeno/análisis , Fibrinopéptido A/análisis , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Estadísticas no Paramétricas
4.
Int J Artif Organs ; 24(5): 263-73, 2001 May.
Artículo en Inglés | MEDLINE | ID: mdl-11420875

RESUMEN

With the increase in high risk patients undergoing cardiac surgery and the substantial mortality among patients waiting for cardiac transplantation, the need for mechanical circulatory support is growing. Several devices are currently available, ranging from the intra-aortic balloon pump to fully implantable ventricular assist devices. Each system has its own features, and proper patient selection as well as the timing of implantation is sometimes difficult. Algorithms for stepwise management in subgroups of patients remain controversial and the concepts of weaning patients after myocardial recovery during mechanical circulatory support need further evaluation for their long-term effects. Future identification of valuable prognostic and risk factors may help in decision-making and allow for improved survival of these often very ill patients. In this report we review the concepts of mechanical circulatory support at our institution with emphasis on a detailed overview of technical features of extracorporeal life support.


Asunto(s)
Oxigenación por Membrana Extracorpórea/métodos , Corazón Auxiliar , Cuidados para Prolongación de la Vida/métodos , Humanos , Factores de Tiempo
5.
Ann Thorac Surg ; 71(2): 723-5, 2001 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-11235745

RESUMEN

Mixed total anomalous pulmonary venous connection (TAPVC) is a rare condition, accounting for only 5% of diagnosed TAPVC. It is associated with a poor prognosis unless surgically corrected by connecting the pulmonary venous sinus to the left atrium and optionally dividing the abnormal connection to the systemic venous system. We report a modified technique of complete intracardiac repair of mixed supracardiac and cardiac TAPVC in a 3-year-old child without pulmonary venous sinus-to-left atrium anastomosis.


Asunto(s)
Cardiopatías Congénitas/cirugía , Venas Pulmonares/anomalías , Implantación de Prótesis Vascular , Preescolar , Cardiopatías Congénitas/diagnóstico , Defectos del Tabique Interatrial/diagnóstico , Defectos del Tabique Interatrial/cirugía , Humanos , Masculino , Venas Pulmonares/cirugía , Técnicas de Sutura , Vena Cava Superior/anomalías , Vena Cava Superior/cirugía
6.
J Thorac Cardiovasc Surg ; 120(6): 1034-9, 2000 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-11088023

RESUMEN

OBJECTIVE: During recent years, transcatheter closure has become an alternative to operations for the treatment of atrial septal defects and patent foramen ovale. However, this procedure may be unsuccessful or complicated and requires surgical treatment. METHODS: We retrospectively analyzed the outcomes of patients who needed surgical treatment after failed or complicated transcatheter closure of an atrial septal defect or a patent foramen ovale. RESULTS: Between April 1994 and March 1999, 124 patients were treated with transcatheter closure of an atrial septal defect or a patent foramen ovale at our institution. We report the results of 10 (8%) patients of this series who required operations after transcatheter closure attempts. In 8 of these 10 patients a significant shunt caused by malposition or dislocation of the device persisted, leading to surgical closure of the defect. In 2 patients injury of the femoral artery at the puncture site required surgical repair. In one patient the device had to be removed surgically from the iliac vein after retraction. One patient died of left ventricular perforation after dislocation of the device and several surgical attempts to close the left ventricular rupture. All other patients recovered well. CONCLUSION: An operation was required after transcatheter closure of an atrial septal defect or a patent foramen ovale in 8% of patients. After device complications, the atrial septal defect and the patent foramen ovale can still successfully be closed surgically with good results and low morbidity. However, serious complications like cardiac perforation may have a fatal outcome. Residual shunt, dislocation, or vascular complications are the most frequent problems that require surgical interventions.


Asunto(s)
Ablación por Catéter/efectos adversos , Defectos del Tabique Interatrial/cirugía , Adolescente , Adulto , Anciano , Ablación por Catéter/instrumentación , Ablación por Catéter/métodos , Ablación por Catéter/mortalidad , Niño , Preescolar , Ecocardiografía Transesofágica , Femenino , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interatrial/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Morbilidad , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía , Reoperación , Estudios Retrospectivos , Análisis de Supervivencia , Insuficiencia del Tratamiento
7.
Ann Thorac Surg ; 69(3): 692-5, 2000 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-10750745

RESUMEN

BACKGROUND: Operation of the descending and thoracoabdominal aorta may be affected by a significant perioperative morbidity, mainly because of ischemic damage of the spinal cord and malperfusion of the abdominal organs. METHODS: A comparative analysis was performed on two consecutive series of patients operated between 1982 and 1998. Group 1 consisted of 90 patients operated with moderate hypothermic left heart bypass. Group 2 included 38 patients operated using deep hypothermic cardiopulmonary bypass and a period of circulatory arrest while performing the proximal anastomosis and distal exsanguination during confection of the distal anastomosis. RESULTS: Main demographic factors and causes of the aortic disease were similar in both groups. Early mortality was significantly higher in the group of patients with aortic cross-clamping (15 of 90, 16%) than in those operated with circulatory arrest (2 of 38, 5.2%), p < 0.001. Paraplegia occurred in 8 patients in the group operated with mild hypothermia (8.8%) but in only 1 patient (2.6%) when deep hypothermia had been used. CONCLUSIONS: In our experience, deep hypothermia combined with distal exsanguination significantly improved the early postoperative outcome after operation of the descending and thoracoabdominal aorta. This technique allowed easy confection of proximal and distal anastomoses, and the duration of the operation was not prolonged significantly through this approach.


Asunto(s)
Aorta/cirugía , Puente Cardiopulmonar , Hipotermia Inducida , Flebotomía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
9.
Ann Thorac Surg ; 68(2): 532-6, 1999 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-10475424

RESUMEN

BACKGROUND: Echocardiography allows for an adequate noninvasive preoperative evaluation in an increasing proportion of pediatric patients before open heart operations. The present study assessed the diagnostic accuracy of both invasive and noninvasive preoperative evaluation in children with congenital heart disease. METHODS: We prospectively evaluated the accuracy of preoperative noninvasive or invasive diagnostic methods. Preoperatively established diagnosis was compared with the intraoperative diagnosis made by surgical inspection and routine perioperative transesophageal echocardiography. RESULTS: During the study period of 30 months (ending in December 1997) 209 open-heart procedures were performed. Eighty-one patients (39%) were in the first year of life at the time of surgery, and 43% of all patients had symptoms. Noninvasive preoperative diagnosis using echocardiography was done exclusively in 142 patients (68%). Of the 67 children who had preoperative catheterization, 4 (6%) showed an additional intraoperative finding that modified the surgical approach in 2 of them. In the 142 patients who had echocardiographic preoperative assessment, the surgeons were confronted with a previously undiagnosed finding in 12 patients (8.5%). The finding was considered significant (prolongation of cardiopulmonary bypass time) in 2 patients and might have affected the outcome in 1 of them, a neonate with transposition of the great arteries and a preoperatively undiagnosed intramural coronary artery, who died postoperatively despite a technically adequate repair. CONCLUSIONS: In many infants and children, diagnostic work-up before open heart operations could be adequately based on an exclusively noninvasive basis by relying on echocardiography alone.


Asunto(s)
Cateterismo Cardíaco , Cardiopatías Congénitas/cirugía , Adolescente , Niño , Preescolar , Anomalías de los Vasos Coronarios/diagnóstico , Anomalías de los Vasos Coronarios/mortalidad , Anomalías de los Vasos Coronarios/cirugía , Ecocardiografía Transesofágica , Femenino , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/mortalidad , Humanos , Lactante , Recién Nacido , Masculino , Estudios Prospectivos , Sensibilidad y Especificidad
10.
Ann Thorac Surg ; 67(3): 843-4, 1999 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-10215246

RESUMEN

Isolated rupture of of the ventricular septum after blunt chest trauma is a very rare traumatic affection. A 21-year-old man was admitted to our hospital because of blunt chest trauma and a forearm fracture. Initial echocardiography did not show any intracardiac or extracardiac pathologic lesions, but 12 hours later this examination was repeated because of the onset of a holosystolic murmur. An unusual traumatic rupture of the ventricular septum was demonstrated. The hemodynamically stable condition of the patient allowed surgical repair to be performed 3 months later.


Asunto(s)
Rotura Cardíaca/etiología , Tabiques Cardíacos/lesiones , Traumatismos Torácicos/complicaciones , Heridas no Penetrantes/complicaciones , Accidentes de Tránsito , Adulto , Ecocardiografía , Rotura Cardíaca/diagnóstico por imagen , Rotura Cardíaca/cirugía , Ventrículos Cardíacos , Humanos , Masculino
12.
Eur J Cardiothorac Surg ; 14 Suppl 1: S76-81, 1998 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-9814798

RESUMEN

OBJECTIVES: To assess intraoperative flow of arterial and venous coronary grafts after myocardial revascularization which may allow early detection of low flow situations, especially during minimally invasive coronary bypass surgery (MIDCAB), and lead to immediate correction of technical problems. METHODS: In two patients with severe and diffuse multi-vessel disease the left internal mammary artery (IMA) was connected to the left anterior descending artery (LAD). During reperfusion, the flow was measured in the IMA and vein grafts using a transit time flow meter. RESULTS: In both cases the IMA showed only a systolic pendulating flow curve with a mean flow of 0-1 ml/min and a high resistance. Manual IMA assessment revealed an adequate pulsation. Both distal IMA anastomoses were re-explored on cardiopulmonary bypass yielding an initial flow of 7 and 14 ml/min, respectively. After treatment with papaverine/adenosine the IMA flow increased from 7 to 26 ml/min (coronary flow reserve (CFR) = 3.7) and from 14 to 46 ml/min (CFR = 3.3), respectively. CONCLUSION: Intraoperative flow assessment of IMA and venous bypass grafts can be recommended to monitor flow; especially during MIDCAB procedures.


Asunto(s)
Circulación Coronaria/fisiología , Enfermedad Coronaria/cirugía , Anastomosis Interna Mamario-Coronaria , Anciano , Velocidad del Flujo Sanguíneo/efectos de los fármacos , Velocidad del Flujo Sanguíneo/fisiología , Circulación Coronaria/efectos de los fármacos , Enfermedad Coronaria/fisiopatología , Epinefrina/farmacología , Circulación Extracorporea , Femenino , Humanos , Cuidados Intraoperatorios , Complicaciones Intraoperatorias/diagnóstico , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos , Papaverina/farmacología , Insuficiencia del Tratamiento
13.
Ann Thorac Surg ; 66(3): 1097-100, 1998 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-9769011

RESUMEN

BACKGROUND: A low-flow situation in arterial and venous grafts has been associated with high rates of perioperative infarction and mortality. This study was designed to look at intraoperative graft flow and resistance in patients with coronary artery disease. METHODS: Coronary artery bypass graft flow was measured in 46 patients. Transit-time flow was used for coronary flow measurements at rest as well as after maximal vasodilation with adenosine infusion. RESULTS: Forty-three of the 46 patients showed normal internal mammary artery graft flow (>20 mL/min); 3 patients had no or minimal graft flow. Redoing the graft anastomosis in these 3 patients resulted in normalization of graft flow. The mean flow increased significantly after correction from 0.5 +/- 0.7 mL/min to 15.7 +/- 9.6 mL/min (p < 0.02). Conversely, vascular resistance decreased significantly from 138 +/- 10 to 4.8 +/- 1.8 Ohmv (p < 0.0001), as did the pulsatility index (from 146.9 +/- 95.7 to 3.4 +/- 1.8; p < 0.001). After correction, coronary flow reserve was 2.5 +/- 1.1. CONCLUSIONS: Measurements of intraoperative flow and resistance as well as derived variables allow assessment of early graft function and thus help prevent graft failure and reduce perioperative infarction. Transit-time volume flow might be a simple tool for quality control in coronary bypass procedures.


Asunto(s)
Hemorreología , Anastomosis Interna Mamario-Coronaria , Grado de Desobstrucción Vascular , Anastomosis Quirúrgica , Humanos , Flujo Pulsátil , Insuficiencia del Tratamiento , Resistencia Vascular
14.
Eur J Cardiothorac Surg ; 14(6): 631-4, 1998 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-9879878

RESUMEN

Heart transplantation represents a valuable therapeutical option for patients with congenital heart disease and end-stage heart failure. We report the case of a young adult patient with a situs inversus and additional complex congenital malformations of the heart who underwent several prior palliative interventions, a biventricular repair being impossible. Orthotopic cardiac transplantation with several technical modifications was performed successfully at the age of 19 years.


Asunto(s)
Puente Cardíaco Derecho , Cardiopatías Congénitas/cirugía , Trasplante de Corazón , Cuidados Paliativos/métodos , Situs Inversus/complicaciones , Anomalías Múltiples/cirugía , Adulto , Cardiopatías Congénitas/complicaciones , Humanos
15.
Ann Thorac Surg ; 66(5): 1818-9, 1998 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-9875805

RESUMEN

Treatment of a rare Streptococcus pneumoniae mycotic aneurysm by homograft replacement failed in a 59-year-old patient because of persistent lobar pneumonia. Despite reoperation with replacement of the infected homograft by a fresh one, he finally died of septicemia. This case illustrates that homograft tissue may be infected per continuum and that extensive debridement of periaortic tissue-including major lung resection-and the use of muscle flaps may be necessary in certain circumstances.


Asunto(s)
Aneurisma Infectado/cirugía , Aorta/trasplante , Infecciones Neumocócicas/cirugía , Aorta Torácica , Humanos , Masculino , Persona de Mediana Edad , Trasplante Homólogo , Insuficiencia del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...