Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Clin Res Cardiol ; 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38953944

RESUMEN

BACKGROUND: Substantial controversy exists regarding the clinical benefit of patients with severe paradoxical low-flow, low-gradient aortic stenosis (PLF-LG AS) from TAVI. Therefore, we compared post-TAVI benefit by long-term mortality (all-cause, CV and SCD), clinical improvement of heart failure symptoms, and cardiac reverse remodelling in guideline-defined AS subtypes. METHODS: We prospectively included 250 consecutive TAVI patients. TTE, 6mwt, MLHFQ, NYHA status and NT-proBNP were recorded at baseline and 6 months. Long-term mortality and causes of death were assessed. RESULTS: 107 individuals suffered from normal EF, high gradient AS (NEF-HG AS), 36 from low EF, high gradient AS (LEF-HG), 52 from "classic" low-flow, low-gradient AS (LEF-LG AS), and 38 from paradoxical low-flow, low-gradient AS (PLF-LG AS). TAVI lead to a significant decrease in MLHFQ score and NT-proBNP levels in all subtypes except for PLF-LG. Regarding reverse remodelling, a significant increase in EF and decrease in LVEDV was present only in subtypes with reduced baseline EF, whereas a significant decrease in LVMI and LAVI could be observed in all subtypes except for PLF-LG. During a follow-up of 3-5 years, PLF-LG patients exhibited the poorest survival among all subtypes (HR 4.2, P = 0.0002 for CV mortality; HR 7.3, P = 0.004 for SCD, in comparison with NEF-HG). Importantly, PLF-LG was independently predictive for CV mortality (HR 2.9 [1.3-6.9], P = 0.009). CONCLUSIONS: PLF-LG patients exhibit the highest mortality (particularly CV and SCD), the poorest symptomatic benefit and the least reverse cardiac remodelling after TAVI among all subtypes. Thus, this cohort seems to gain the least benefit.

2.
ESC Heart Fail ; 11(3): 1636-1646, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38407567

RESUMEN

AIMS: Studies have reported a strongly varying co-prevalence of aortic stenosis (AS) and cardiac amyloidosis (CA). We sought to histologically determine the co-prevalence of AS and CA in patients undergoing transcatheter aortic valve replacement (TAVR). Consequently, we aimed to derive an algorithm to identify cases in which to suspect the co-prevalence of AS and CA. METHODS AND RESULTS: In this prospective, monocentric study, endomyocardial biopsies of 162 patients undergoing TAVR between January 2017 and March 2021 at the University Medical Centre Göttingen were analysed by one pathologist blinded to clinical data using haematoxylin-eosin staining, Elastica van Gieson staining, and Congo red staining of endomyocardial biopsies. CA was identified in only eight patients (4.9%). CA patients had significantly higher N-terminal pro-brain natriuretic peptide (NT-proBNP) levels (4356.20 vs. 1938.00 ng/L, P = 0.034), a lower voltage-to-mass ratio (0.73 vs. 1.46 × 10-2 mVm2/g, P = 0.022), and lower transaortic gradients (Pmean 17.5 vs. 38.0 mmHg, P = 0.004) than AS patients. Concomitant CA was associated with a higher prevalence of post-procedural acute kidney injury (50.0% vs. 13.1%, P = 0.018) and sudden cardiac death [SCD; P (log-rank test) = 0.017]. Following propensity score matching, 184 proteins were analysed to identify serum biomarkers of concomitant CA. CA patients expressed lower levels of chymotrypsin (P = 0.018) and carboxypeptidase 1 (P = 0.027). We propose an algorithm using commonly documented parameters-stroke volume index, ejection fraction, NT-proBNP levels, posterior wall thickness, and QRS voltage-to-mass ratio-to screen for CA in AS patients, reaching a sensitivity of 66.6% with a specificity of 98.1%. CONCLUSIONS: The co-prevalence of AS and CA was lower than expected, at 4.9%. Despite excellent 1 year mortality, AS + CA patients died significantly more often from SCD. We propose a multimodal algorithm to facilitate more effective screening for CA containing parameters commonly documented during clinical routine. Proteomic biomarkers may yield additional information in the future.


Asunto(s)
Amiloidosis , Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Estudios Prospectivos , Amiloidosis/complicaciones , Amiloidosis/diagnóstico , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Anciano , Biopsia , Cardiomiopatías/diagnóstico , Cardiomiopatías/etiología , Miocardio/patología , Miocardio/metabolismo , Estudios de Seguimiento , Prevalencia
3.
Clin Res Cardiol ; 2024 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-38236417

RESUMEN

BACKGROUND: Patients with severe aortic stenosis (AS) and reduced left ventricular ejection fraction (LVEF) can be distinguished into high- (HG) and low-gradient (LG) subgroups. However, less is known about their characteristics and underlying (pathophysiological) hemodynamic mechanisms. METHODS: 98 AS patients with reduced LVEF were included. Subgroup characteristics were analyzed by a multimodal approach using clinical and histological data, next-generation sequencing (NGS) and applying echocardiography as well as cardiovascular magnetic resonance (CMR) imaging. Biopsy samples were analyzed with respect to fibrosis and mRNA expression profiles. RESULTS: 40 patients were classified as HG-AS and 58 patients as LG-AS. Severity of AS was comparable between the subgroups. Comparison of both subgroups revealed no differences in LVEF (p = 0.1), LV mass (p = 0.6) or end-diastolic LV diameter (p = 0.12). Neither histological (HG: 23.2% vs. LG: 25.6%, p = 0.73) and circulating biomarker-based assessment (HG: 2.6 ± 2.2% vs. LG: 3.2 ± 3.1%; p = 0.46) of myocardial fibrosis nor global gene expression patterns differed between subgroups. Mitral regurgitation (MR), atrial fibrillation (AF) and impaired right ventricular function (MR: HG: 8% vs. LG: 24%; p < 0.001; AF: HG: 30% vs. LG: 51.7%; p = 0.03; RVSVi: HG 36.7 vs. LG 31.1 ml/m2, p = 0.045; TAPSE: HG 20.2 vs. LG 17.3 mm, p = 0.002) were more frequent in LG-AS patients compared to HG-AS. These pathologies could explain the higher mortality of LG vs. HG-AS patients. CONCLUSION: In patients with low-flow severe aortic stenosis, low transaortic gradient and cardiac output are not primarily due to LV dysfunction or global changes in gene expression, but may be attributed to other additional cardiac pathologies like mitral regurgitation, atrial fibrillation or right ventricular dysfunction. These factors should also be considered during planning of aortic valve replacement.

4.
ESC Heart Fail ; 10(4): 2307-2318, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37060191

RESUMEN

AIMS: There is evidence to suggest that the subtype of aortic stenosis (AS), the degree of myocardial fibrosis (MF), and level of aortic valve calcification (AVC) are associated with adverse cardiac outcome in AS. Because little is known about their respective contribution, we sought to investigate their relative importance and interplay as well as their association with adverse cardiac events following transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: One hundred consecutive patients with severe AS and indication for TAVR were prospectively enrolled between January 2017 and October 2018. Patients underwent transthoracic echocardiography, multidetector computed tomography, and left ventricular endomyocardial biopsies at the time of TAVR. The final study cohort consisted of 92 patients with a completed study protocol, 39 (42.4%) of whom showed a normal ejection fraction (EF) high-gradient (NEFHG) AS, 13 (14.1%) a low EF high-gradient (LEFHG) AS, 25 (27.2%) a low EF low-gradient (LEFLG) AS, and 15 (16.3%) a paradoxical low-flow, low-gradient (PLFLG) AS. The high-gradient phenotypes (NEFHG and LEFHG) showed the largest amount of AVC (807 ± 421 and 813 ± 281 mm3 , respectively) as compared with the low-gradient phenotypes (LEFLG and PLFLG; 503 ± 326 and 555 ± 594 mm3 , respectively, P < 0.05). Conversely, MF was most prevalent in low-output phenotypes (LEFLG > LEFHG > PLFLG > NEFHG, P < 0.05). This was paralleled by a greater cardiovascular (CV) mortality within 600 days after TAVR (LEFLG 28% > PLFLG 26.7% > LEFHG 15.4% > NEFHG 2.5%; P = 0.023). In patients with a high MF burden, a higher AVC was associated with a lower mortality following TAVR (P = 0.045, hazard ratio 0.261, 95% confidence interval 0.07-0.97). CONCLUSIONS: MF is associated with adverse CV outcome following TAVR, which is most prevalent in low EF situations. In the presence of large MF burden, patients with large AVC have better outcome following TAVR. Conversely, worse outcome in large MF and relatively little AVC may be explained by a relative prominence of an underlying cardiomyopathy. The better survival rates in large AVC patients following TAVR indicate TAVR induced relief of severe AS-associated pressure overload with subsequently improved outcome.


Asunto(s)
Estenosis de la Válvula Aórtica , Cardiomiopatías , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Fibrosis
5.
J Cardiovasc Magn Reson ; 24(1): 45, 2022 07 28.
Artículo en Inglés | MEDLINE | ID: mdl-35897100

RESUMEN

BACKGROUND: Since cardiovascular magnetic resonance (CMR) imaging allows comprehensive quantification of both myocardial function and structure we aimed to assess myocardial remodeling processes in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR). METHODS: CMR imaging was performed in 40 patients with severe AS before and 1 year after TAVR. Image analyses comprised assessments of myocardial volumes, CMR-feature-tracking based atrial and ventricular strain, myocardial T1 mapping, extracellular volume fraction-based calculation of left ventricular (LV) cellular and matrix volumes, as well as ischemic and non-ischemic late gadolinium enhancement analyses. Moreover, biomarkers including NT-proBNP as well as functional and clinical status were documented. RESULTS: Myocardial function improved 1 year after TAVR: LV ejection fraction (57.9 ± 16.9% to 65.4 ± 14.5%, p = 0.002); LV global longitudinal (- 21.4 ± 8.0% to -25.0 ± 6.4%, p < 0.001) and circumferential strain (- 36.9 ± 14.3% to - 42.6 ± 11.8%, p = 0.001); left atrial reservoir (13.3 ± 6.3% to 17.8 ± 6.7%, p = 0.001), conduit (5.5 ± 3.2% to 8.4 ± 4.6%, p = 0.001) and boosterpump strain (8.2 ± 4.6% to 9.9 ± 4.2%, p = 0.027). This was paralleled by regression of total myocardial volume (90.3 ± 21.0 ml/m2 to 73.5 ± 17.0 ml/m2, p < 0.001) including cellular (55.2 ± 13.2 ml/m2 to 45.3 ± 11.1 ml/m2, p < 0.001) and matrix volumes (20.7 ± 6.1 ml/m2 to 18.8 ± 5.3 ml/m2, p = 0.036). These changes were paralleled by recovery from heart failure (decrease of NYHA class: p < 0.001; declining NT-proBNP levels: 2456 ± 3002 ng/L to 988 ± 1222 ng/L, p = 0.001). CONCLUSION: CMR imaging enables comprehensive detection of myocardial remodeling in patients undergoing TAVR. Regression of LV matrix volume as a surrogate for reversible diffuse myocardial fibrosis is accompanied by increase of myocardial function and recovery from heart failure. Further data are required to define the value of these parameters as therapeutic targets for optimized management of TAVR patients. Trial registration DRKS, DRKS00024479. Registered 10 December 2021-Retrospectively registered, https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00024479.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/cirugía , Medios de Contraste , Gadolinio , Humanos , Espectroscopía de Resonancia Magnética , Valor Predictivo de las Pruebas , Estudios Prospectivos , Volumen Sistólico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Función Ventricular Izquierda , Remodelación Ventricular
6.
J Interv Cardiol ; 2022: 1368878, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35539443

RESUMEN

Background: Cardiovascular magnetic resonance imaging is considered the reference standard for assessing cardiac morphology and function and has demonstrated prognostic utility in patients undergoing transcatheter aortic valve replacement (TAVR). Novel fully automated analyses may facilitate data analyses but have not yet been compared against conventional manual data acquisition in patients with severe aortic stenosis (AS). Methods: Fully automated and manual biventricular assessments were performed in 139 AS patients scheduled for TAVR using commercially available software (suiteHEART®, Neosoft; QMass®, Medis Medical Imaging Systems). Volumetric assessment included left ventricular (LV) mass, LV/right ventricular (RV) end-diastolic/end-systolic volume, LV/RV stroke volume, and LV/RV ejection fraction (EF). Results of fully automated and manual analyses were compared. Regression analyses and receiver operator characteristics including area under the curve (AUC) calculation for prediction of the primary study endpoint cardiovascular (CV) death were performed. Results: Fully automated and manual assessment of LVEF revealed similar prediction of CV mortality in univariable (manual: hazard ratio (HR) 0.970 (95% CI 0.943-0.997) p=0.032; automated: HR 0.967 (95% CI 0.939-0.995) p=0.022) and multivariable analyses (model 1: (including significant univariable parameters) manual: HR 0.968 (95% CI 0.938-0.999) p=0.043; automated: HR 0.963 [95% CI 0.933-0.995] p=0.024; model 2: (including CV risk factors) manual: HR 0.962 (95% CI 0.920-0.996) p=0.027; automated: HR 0.954 (95% CI 0.920-0.989) p=0.011). There were no differences in AUC (LVEF fully automated: 0.686; manual: 0.661; p=0.21). Absolute values of LV volumes differed significantly between automated and manual approaches (p < 0.001 for all). Fully automated quantification resulted in a time saving of 10 minutes per patient. Conclusion: Fully automated biventricular volumetric assessments enable efficient and equal risk prediction compared to conventional manual approaches. In addition to significant time saving, this may provide the tools for optimized clinical management and stratification of patients with severe AS undergoing TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Inteligencia Artificial , Humanos , Medición de Riesgo , Volumen Sistólico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Función Ventricular Izquierda
8.
EuroIntervention ; 17(1): 81-87, 2021 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-32657277

RESUMEN

BACKGROUND: The Cardioband tricuspid valve reconstruction system is a size-adjustable tricuspid reconstruction device for interventional treatment of tricuspid regurgitation (TR). Contraction of the device after successful implantation can be associated with an acute deformation of the right coronary artery (RCA). AIMS: The aim of this study was to provide data on the persistence and clinical significance of acute RCA deformation following Cardioband implant procedures. METHODS: Data from all patients with intraprocedural RCA deformation during Cardioband implantation were collected from four centres between October 2018 and January 2020. Control angiographies were performed in all of these patients before discharge. RESULTS: RCA deformation occurred in 14 out of 51 patients. Follow-up coronary angiography showed a complete resolution of deformation in all cases while patients remained clinically asymptomatic and had an uneventful post-interventional course. Intraprocedural coronary stent implantation was performed in two of the earlier cases according to the personal assessment of the implanters. CONCLUSIONS: RCA deformation is relatively frequent following interventional tricuspid annuloplasty but appears to be completely reversible in the absence of flow impairment or vascular damage. Based on our early experience watchful waiting is the most appropriate strategy to avoid unnecessary coronary interventions.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Cateterismo Cardíaco/efectos adversos , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía
9.
J Cardiovasc Magn Reson ; 22(1): 46, 2020 06 22.
Artículo en Inglés | MEDLINE | ID: mdl-32564773

RESUMEN

BACKGROUND: Myocardial fibrosis is a major determinant of outcome in aortic stenosis (AS). Novel fast real-time (RT) cardiovascular magnetic resonance (CMR) mapping techniques allow comprehensive quantification of fibrosis but have not yet been compared against standard techniques and histology. METHODS: Patients with severe AS underwent CMR before (n = 110) and left ventricular (LV) endomyocardial biopsy (n = 46) at transcatheter aortic valve replacement (TAVR). Midventricular short axis (SAX) native, post-contrast T1 and extracellular volume fraction (ECV) maps were generated using commercially available modified Look-Locker Inversion recovery (MOLLI) (native: 5(3)3, post-contrast: 4(1)3(1)2) and RT single-shot inversion recovery Fast Low-Angle Shot (FLASH) with radial undersampling. Focal late gadolinium enhancement was excluded from T1 and ECV regions of interest. ECV and LV mass were used to calculate LV matrix volumes. Variability and agreements were assessed between RT, MOLLI and histology using intraclass correlation coefficients, coefficients of variation and Bland Altman analyses. RESULTS: RT and MOLLI derived ECV were similar for midventricular SAX slice coverage (26.2 vs. 26.5, p = 0.073) and septal region of interest (26.2 vs. 26.5, p = 0.216). MOLLI native T1 time was in median 20 ms longer compared to RT (p < 0.001). Agreement between RT and MOLLI was best for ECV (ICC > 0.91), excellent for post-contrast T1 times (ICC > 0.81) and good for native T1 times (ICC > 0.62). Diffuse collagen volume fraction by biopsies was in median 7.8%. ECV (RT r = 0.345, p = 0.039; MOLLI r = 0.40, p = 0.010) and LV matrix volumes (RT r = 0.45, p = 0.005; MOLLI r = 0.43, p = 0.007) were the only parameters associated with histology. CONCLUSIONS: RT mapping offers fast and sufficient ECV and LV matrix volume calculation in AS patients. ECV and LV matrix volume represent robust and universally comparable parameters with associations to histologically assessed fibrosis and may emerge as potential targets for clinical decision making.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Miocardio/patología , Función Ventricular Izquierda , Anciano , Anciano de 80 o más Años , Válvula Aórtica/patología , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Biopsia , Femenino , Fibrosis , Humanos , Masculino , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Reemplazo de la Válvula Aórtica Transcatéter , Remodelación Ventricular
10.
Eur Heart J ; 41(20): 1903-1914, 2020 05 21.
Artículo en Inglés | MEDLINE | ID: mdl-32049275

RESUMEN

AIMS: Myocardial fibrosis (MF) might represent a key player in pathophysiology of heart failure in aortic stenosis (AS). We aimed to assess its impact on left ventricular (LV) remodelling, recovery, and mortality after transcatheter aortic valve implantation (TAVI) in different AS subtypes. METHODS AND RESULTS: One hundred patients with severe AS were prospectively characterized clinically and echocardiographically at baseline (BL), 6 months, 1 year, and 2 years following TAVI. Left ventricular biopsies were harvested after valve deployment. Myocardial fibrosis was assessed after Masson's trichrome staining, and fibrotic area was calculated as percentage of total tissue area. Patients were stratified according to MF above (MF+) or below (MF-) median percentage MF (≥11% or <11%). Myocardial fibrosis burden differed significantly between AS subtypes, with highest levels in low ejection fraction (EF), low-gradient AS and lowest levels in normal EF, high-gradient AS (29.5 ± 26.4% vs. 13.5 ± 16.1%, P = 0.003). In the entire cohort, MF+ was significantly associated with poorer LV function, higher extent of pathological LV remodelling, and more pronounced clinical heart failure at BL. After TAVI, MF+ was associated with a delay in normalization of LV geometry and function but not per se with absence of reverse remodelling and clinical improvement. However, 22 patients died during follow-up (mean, 11 months), and 14 deaths were classified as cardiovascular (CV) (n = 9 arrhythmia-associated). Importantly, 13 of 14 CV deaths occurred in MF+ patients (CV mortality 26.5% in MF+ vs. 2% in MF- patients, P = 0.0003). Multivariate analysis identified MF+ as independent predictor of CV mortality [hazard ratio (HR) 27.4 (2.0-369), P = 0.01]. CONCLUSION: Histological MF is associated with AS-related pathological LV remodelling and independently predicts CV mortality after TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Fibrosis , Hemodinámica , Humanos , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Remodelación Ventricular
12.
Thromb Haemost ; 119(9): 1527-1538, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31226717

RESUMEN

OBJECTIVES: This prespecified analysis of the TROPICAL-ACS trial aimed to assess the impact of gender on clinical outcomes and platelet reactivity (PR) following guided de-escalation of dual antiplatelet treatment (DAPT) in acute coronary syndrome (ACS) patients. BACKGROUND: Guided de-escalation of DAPT was recently identified as an effective alternative treatment strategy in ACS. METHODS: We used Cox proportional hazards models and linear regression analysis to assess the interaction of gender with clinical endpoints and PR. RESULTS: In both male (n = 2,052) and female (n = 558) patients, the 1-year incidence of the primary endpoint did not differ in guided de-escalation versus control group patients (male: 7.0% vs. 9.0%; hazard ratio [HR], 0.78, 95% confidence interval [CI], 0.57-1.06, p = 0.11; female: 8.4% vs. 9.2%; HR, 0.92, 95% CI, 0.53-1.62, p = 0.76, p int = 0.60). The 1-year incidence of combined ischemic events (male: 2.5% vs. 3.3%; HR, 0.76, 95% CI, 0.46-1.26, p = 0.29; female: 2.2% vs. 2.8%; HR, 0.78,95% CI, 0.27-2.25, p = 0.65, p int = 0.96) as well as Bleeding Academic Research Consortium ≥ 2 bleeding (male: 4.6% vs. 6.0%; HR, 0.77, 95% CI, 0.52-1.12, p = 0.17; female: 6.2% vs. 6.4%; HR, 0.99, 95% CI, 0.51-1.92, p = 0.97, p int = 0.51) was similar in the guided de-escalation versus control group for both male and female patients. Interaction testing revealed no significant impact of gender on PR levels (prasugrel or clopidogrel) across treatment groups (p int = 0.72). CONCLUSION: Guided de-escalation of DAPT appears to be equally safe and effective in women and men. Especially in patients with increased bleeding risk and independent from gender, a guided DAPT de-escalation strategy may be used as an alternative treatment strategy. CLINICAL TRIAL REGISTRATION: URL: https//www.clinicaltrials.gov. Unique Identifier: NCT: 01959451.


Asunto(s)
Síndrome Coronario Agudo/terapia , Plaquetas/fisiología , Clopidogrel/uso terapéutico , Terapia Antiplaquetaria Doble , Clorhidrato de Prasugrel/uso terapéutico , Factores Sexuales , Anciano , Europa (Continente)/epidemiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea , Activación Plaquetaria , Resultado del Tratamiento
14.
EuroIntervention ; 9(12): 1407-17, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24972141

RESUMEN

AIMS: MitraClip implantation is evolving as a potential alternative treatment to conventional surgery in high-risk patients with significant mitral regurgitation (MR). However, outcome predictors are under-investigated. The aim of this study was to identify predictors of midterm mortality and heart failure rehospitalisation after percutaneous mitral valve repair with MitraClip. METHODS AND RESULTS: A total of 150 consecutive patients were followed for a median of 463 days. Survival analyses were performed for baseline characteristics, risk scores and failure of acute procedural success (APS) defined as persisting MR grade 3+ or 4+. Univariate significant risk stratifiers were tested in multivariate analyses using a Cox proportional hazards model. Overall survival was 96% at 30 days, 79.5% at 12 months, and 62% at two years. Multivariate analysis identified APS failure (HR 2.13, p=0.02), NYHA Class IV at baseline (HR 2.11, p=0.01) and STS score ≥12 (HR 2.20, p<0.0001) as significant independent predictors of all-cause mortality, and APS failure (HR 2.31, p=0.01) and NYHA Class IV at baseline (HR 1.89, p=0.03) as significant independent predictors of heart failure rehospitalisation. Furthermore, a post-procedural significant decrease in hospitalisation rate could only be observed after successful interventions (0.89±1.07 per year before vs. 0.54±0.96 after implantation, p=0.01). Patients with severely dilated and overloaded ventricles who did not meet EVEREST II eligibility criteria were at higher risk of APS failure. CONCLUSIONS: The failure of acute procedural success proved to have the most important impact on outcome after MitraClip implantation.


Asunto(s)
Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Insuficiencia Cardíaca/etiología , Insuficiencia de la Válvula Mitral/terapia , Válvula Mitral/fisiopatología , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/mortalidad , Distribución de Chi-Cuadrado , Femenino , Alemania , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Análisis Multivariante , Readmisión del Paciente , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Insuficiencia del Tratamiento
15.
J Invasive Cardiol ; 25(10): 508-10, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24088424

RESUMEN

UNLABELLED: This study was designed to show the feasibility, safety, and efficacy of venous access-site closure with a single 6 Fr suture-mediated Proglide (Abbott Vascular) during MitraClip procedures. METHODS: Preclosure of the right femoral vein with Proglide used for access with the 24 Fr guiding catheter was performed. A total of 72 patients undergoing MitraClip were enrolled in this study (28 patients retrospectively and 44 patients prospectively), of whom 42 patients underwent a groin examination with ultrasound 2 days after the procedure. RESULTS: Only 1 patient (1.4%) needed transfusion of packed cells because of bleeding and hematoma in the groin due to Proglide failure. None of the patients that were examined with ultrasound revealed an arteriovenous fistula or a spurious aneurysm, a local thrombosis, or a local stenosis related to the Proglide device. CONCLUSION: This study demonstrates that vascular closure with the suture-mediated Proglide system is feasible, safe, and efficacious in large venous sites of 24 Fr as needed in patients undergoing MitraClip implantation despite the necessity of anticoagulation or platelet inhibition.


Asunto(s)
Cateterismo Cardíaco/efectos adversos , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Técnicas Hemostáticas/instrumentación , Válvula Mitral/cirugía , Hemorragia Posoperatoria/cirugía , Técnicas de Sutura/instrumentación , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/métodos , Diseño de Equipo , Femenino , Vena Femoral , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Hemorragia Posoperatoria/etiología , Estudios Prospectivos , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...