Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Int J Biol Macromol ; 256(Pt 1): 128295, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37992929

RESUMEN

Heart failure (HF) is emerging as a leading cause of death worldwide. Estimation of BNP levels is a routine diagnosis in these patients. However, in patients having high body-mass index (BMI), renal disease or in geriatric patients, BNP level is reported to be noisy and leads to incongruous conclusion. Thus, for better risk stratification among heart failure patients, it is imperative to look for a superior biomarker. In recent times, sST2 has shown promise as a biomarker. Identifying such biomarkers in peripheral blood of HF patients, need an affine and selective molecular recognition element. Thus, in the current study an aptamer (sS9_P) against sST2 was identified from an aptamer library. Systematic Evolution of Ligands through Exponential enrichment (SELEX) derived aptamer evinced role of its primer binding domains in maintaining its selectivity. This aptamer candidate demonstrated dissociation constant (Kd) in low nanomolar range, and the Limit of Detection (LOD) was ~4 ng. Circular dichroism confirms the formation of complex stem-loop like structure. The well characterized sS9_P aptamer was used in an Aptamer Linked Immobilized Sorbent Assay (ALISA) to detect sST2 level in patients' serum (n = 99). Aptamer sS9_P has shown significant discrimination to differentiate HF patients and healthy volunteers with a reasonable specificity (~83 %) with a modest sensitivity of ~64 %. While sST-2 antibody has shown poor specificity of ~44% but good sensitivity (~87%). The insight obtained from this study indicates that a combination of aptamer and antibody-based assay can be used to design a point-of-care assay for the rapid detection of HF patients in emergency settings.


Asunto(s)
Aptámeros de Nucleótidos , Insuficiencia Cardíaca , Humanos , Anciano , Aptámeros de Nucleótidos/metabolismo , Proteína 1 Similar al Receptor de Interleucina-1 , Pronóstico , Insuficiencia Cardíaca/diagnóstico , Biomarcadores
2.
Biosensors (Basel) ; 12(5)2022 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-35624657

RESUMEN

Better diagnostics are always essential for the treatment and prevention of a disease. Existing technologies for detecting infectious and non-infectious diseases are mostly tedious, expensive, and do not meet the World Health Organization's (WHO) ASSURED (affordable, sensitive, specific, user-friendly, rapid and robust, equipment-free, and deliverable to end user) criteria. Hence, more accurate, sensitive, and faster diagnostic technologies that meet the ASSURED criteria are highly required for timely and evidenced-based treatment. Presently, the diagnostics industry is finding interest in microfluidics-based biosensors, as this integration comprises all qualities, such as reduction in the size of the equipment, rapid turnaround time, possibility of parallel multiple analysis or multiplexing, etc. Microfluidics deal with the manipulation/analysis of fluid within micrometer-sized channels. Biosensors comprise biomolecules immobilized on a physicochemical transducer for the detection of a specific analyte. In this review article, we provide an outline of the history of microfluidics, current practices in the selection of materials in microfluidics, and how and where microfluidics-based biosensors have been used for the diagnosis of infectious and non-infectious diseases. Our inclination in this review article is toward the employment of microfluidics-based biosensors for the improvement of already existing/traditional methods in order to reduce efforts without compromising the accuracy of the diagnostic test. This article also suggests the possible improvements required in microfluidic chip-based biosensors in order to meet the ASSURED criteria.


Asunto(s)
Técnicas Biosensibles , Enfermedades Transmisibles , Enfermedades no Transmisibles , Técnicas Biosensibles/métodos , Enfermedades Transmisibles/diagnóstico , Humanos , Microfluídica
3.
RSC Adv ; 10(48): 28906-28917, 2020 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-35520059

RESUMEN

Aptamers for Lucentis were selected using 10 rounds of a modified and highly stringent SELEX process. Affinity column chromatography was used for the binding, partitioning, and elution steps, and the regeneration of ssDNA was performed via asymmetric PCR in the SELEX process. The interaction of aptamers with Lucentis was studied by means of the HADDOCK web server docking program. In addition, the secondary structures of aptamers were interrogated using the mfold web server to check common regions responsible for better affinity towards Lucentis. The two best aptamers for Lucentis (aptamers 1 and 25) were found to have dissociation constant (K d) values between 23 and 35 nM by means of thermofluorimetric and non-faradaic impedance spectroscopy (NFIS) analysis. The low dissociation constants in the nanomolar range showed the high specificities of the aptamers for Lucentis. Selectivity tests were also performed using both aptamers with different proteins in which negligible responses were obtained from interfering proteins with respect to Lucentis. Although neither of the two aptamers showed prominent responses to the interfering proteins, slightly better selectivity was shown by aptamer 1. The same aptamers were tested for their application in the detection of Lucentis in spiked and real media broth samples. For this detection test, interdigitated (IDT) gold electrodes on a glass substrate were fabricated using standard photolithography and thermal deposition techniques. NFIS measurements were used for the label-free detection of Lucentis in samples. The linear ranges of detection for aptamers 1 and 25 were found to be 22-100 nM and 40-100 nM, respectively. The LODs for aptamers 1 and 25 were calculated to be 22 nM and 40 nM, respectively, which were significantly better than the values from a HPLC-based detection method (about 240 nM). The real sample analysis results were cross-checked via a standard HPLC method, and better correlation was found between the HPLC and aptamer 1 results than the aptamer 25 results; hence, aptamer 1 can be further analyzed and tested for use in affinity column chromatography and detection-kit/chip-based PAT for Lucentis bioproduction.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...