Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Ophthalmology ; 120(12): 2714-2724, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24161406

RESUMEN

OBJECTIVE: To investigate the feasibility of handheld (HH) ultra-high-resolution spectral-domain optical coherence tomography (SD-OCT) in young children with nystagmus, to determine its sensitivity and specificity in classifying foveal abnormalities, and to investigate its potential to determine the cause of infantile nystagmus with the use of foveal morphology. DESIGN: Prospective, case-control study. PARTICIPANTS AND CONTROLS: A total of 50 patients with nystagmus and 50 healthy control subjects (mean age, 3.2 years; range, 0-8 years). METHODS: Each patient was scanned using HH SD-OCT (Bioptigen Inc., Research Triangle Park, NC) without sedation, and foveal morphology was classified into 1 of 4 categories: (1) typical foveal hypoplasia (predicting clinical diagnosis of albinism, PAX6 mutations, or isolated foveal hypoplasia); (2) atypical foveal hypoplasia (predicting achromatopsia); (3) other foveal changes (corresponding to retinal dystrophies); and (4) normal fovea (predicting idiopathic or manifest latent nystagmus). An independent interpretation of the HH SD-OCT scans by masked examiners was performed, and the sensitivity and specificity of the predicted diagnosis were calculated. MAIN OUTCOME MEASURES: The success rate of image acquisition and sensitivity and specificity of the HH SD-OCT in classifying foveal abnormalities. RESULTS: In 94% of examinations, HH SD-OCT was successful. Twenty-three patients had typical foveal hypoplasia (category 1). Of these patients, 21 were diagnosed with albinism and 2 were diagnosed with PAX6 mutations. Five patients were classified as atypical (category 2) and diagnosed with achromatopsia. Six patients had other abnormal foveal morphology (category 3) and were diagnosed with retinal dystrophy. Sixteen patients had normal foveal morphology (category 4). Of these patients, 12 were diagnosed with idiopathic nystagmus and 4 were diagnosed with manifest latent nystagmus. Sensitivities of HH SD-OCT for classifying typical or atypical foveal hypoplasia, other abnormal foveal morphology, and normal morphology were 92.8%, 86.7%, 41.1%, and 88.4%, respectively, with specificities of 91.4%, 94.8%, 97.7% and 95.1%, respectively. CONCLUSIONS: We demonstrate excellent feasibility of HH SD-OCT in the diagnosis of conditions associated with infantile nystagmus. The HH SD-OCT classification of foveal abnormalities was highly sensitive and specific. This classification was used to determine the underlying cause of infantile nystagmus. Handheld SD-OCT in early childhood can facilitate focused investigations and earlier diagnosis. This is important in an era when potentially time-sensitive treatment, such as gene therapy, is imminent.


Asunto(s)
Anomalías del Ojo/clasificación , Fóvea Central/anomalías , Nistagmo Congénito/etiología , Tomografía de Coherencia Óptica/instrumentación , Albinismo Ocular/diagnóstico , Aniridia/diagnóstico , Aniridia/genética , Estudios de Casos y Controles , Niño , Preescolar , Defectos de la Visión Cromática/diagnóstico , Anomalías del Ojo/diagnóstico , Proteínas del Ojo/genética , Estudios de Factibilidad , Proteínas de Homeodominio/genética , Humanos , Lactante , Nistagmo Congénito/diagnóstico , Factor de Transcripción PAX6 , Factores de Transcripción Paired Box/genética , Valor Predictivo de las Pruebas , Estudios Prospectivos , Proteínas Represoras/genética , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...