Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Nat Commun ; 14(1): 955, 2023 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-36804939

RESUMEN

Proton-boron (p11B) fusion is an attractive potential energy source but technically challenging to implement. Developing techniques to realize its potential requires first developing the experimental capability to produce p11B fusion in the magnetically-confined, thermonuclear plasma environment. Here we report clear experimental measurements supported by simulation of p11B fusion with high-energy neutral beams and boron powder injection in a high-temperature fusion plasma (the Large Helical Device) that have resulted in diagnostically significant levels of alpha particle emission. The injection of boron powder into the plasma edge results in boron accumulation in the core. Three 2 MW, 160 kV hydrogen neutral beam injectors create a large population of well-confined, high -energy protons to react with the boron plasma. The fusion products, MeV alpha particles, are measured with a custom designed particle detector which gives a fusion rate in very good relative agreement with calculations of the global rate. This is the first such realization of p11B fusion in a magnetically confined plasma.

2.
Rev Sci Instrum ; 92(3): 033548, 2021 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-33820036

RESUMEN

In the current experimental device of TAE Technologies, C-2W (also called "Norman"), record breaking advanced beam-driven field-reversed configuration (FRC) plasmas are produced and sustained in steady state utilizing variable energy neutral beams (15-40 keV, total power up to 20 MW), advanced divertors, bias electrodes, and an active plasma control system. This fully operational experiment is coupled with a fully operational suite of advanced diagnostic systems. The suite consists of 60+ individual systems spanning 20 categories, including magnetic sensors, Thomson scattering, interferometry/polarimetry, spectroscopy, fast imaging, bolometry, reflectometry, charged and neutral particle analysis, fusion product detection, and electric probes. Recently, measurements of main ion temperatures via a diagnostic neutral beam, axial profiles of energy flux from an array of bolometers, and divertor and edge plasma parameters via an extensive set of electric probes, interferometers, and spectrometers have all been made available. All the diagnostics work together to provide a complete picture of the FRC, fast-ion inventory, and edge plasma details enabling tomographic reconstruction of plasma parameter profiles and real-time plasma control.

3.
Rev Sci Instrum ; 89(10): 10K114, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399699

RESUMEN

The new C-2W experiment (also called Norman) at TAE Technologies, Inc. studies the evolution of field-reversed configuration (FRC) plasmas sustained by neutral beam injection. Data on the FRC plasma performance are provided by a comprehensive suite of diagnostics that includes over 700 magnetic sensors, four interferometer systems, multi-chord far-infrared polarimetry, two Thomson scattering systems, ten types of spectroscopic measurements, multiple fast imaging cameras with selectable atomic line filters, bolometry, reflectometry, neutral particle analyzers, and fusion product detectors. Most of these diagnostic systems are newly built using experience and data from the preceding C-2U experiment to guide the design process. A variety of commercial and custom acquisition electronics collect over 4000 raw signals from the C-2W diagnostics. These data are processed into physics results using a large-scale database of diagnostics metadata and analysis software, both built using open-source software tools.

4.
Rev Sci Instrum ; 89(10): 10H116, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399746

RESUMEN

A versatile combination Doppler backscattering and Cross-Polarization Scattering (CPS) diagnostic for the C-2W beam-driven field-reversed configuration is described. This system is capable of measuring density fluctuations and perpendicular magnetic field fluctuations across a wide wavenumber range (2.5 ≤ k θ ρ s ≤ 50), with typical resolution Δk θ/k θ ≤ 0.4-0.8. Four tunable frequencies (26 GHz ≤ f ≤ 60 GHz corresponding to plasma cut-off densities 0.8 × 1019 ≤ n e ≤ 4.4 × 1019 m-3) are launched via quasi-optical beam combiners/polarizers and an adjustable parabolic focusing mirror selecting the beam incidence angle. GENRAY ray tracing shows that the incident O-mode and backscattered CPS X-mode beam trajectories for C-2W plasma parameters nearly overlap, allowing simultaneous detection of ñ and B̃ r or B̃ θ from essentially the same scattering volume.

5.
Rev Sci Instrum ; 89(10): 10J114, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399830

RESUMEN

Field-reversed configuration (FRC) Amplification via Translation-Collisional Merging (FAT-CM) experiments have recently commenced to study physics phenomena of colliding and merged FRC plasma states. Two independently formed FRCs are translated into the confinement region of the FAT-CM device, collided near the mid-plane of the device with a relative speed of up to ∼400 km/s, and a final merged FRC plasma state is achieved. To measure internal magnetic field profiles of the translated and merged FRC plasmas as well as to understand its collisional-merging process, an internal magnetic probe array, developed by TAE Technologies, has been installed in the mid-plane of the FAT-CM device. Initial magnetic field measurements indicate that both the translated and the merged FRC plasma states exhibit a clear field-reversed structure, which is qualitatively in good agreement with 2D MHD simulation. It is found and verified that a sufficient mirror field in the confinement region is required for colliding FRCs to be fully merged into a single FRC plasma state.

6.
Sci Rep ; 7(1): 6425, 2017 07 25.
Artículo en Inglés | MEDLINE | ID: mdl-28743898

RESUMEN

Many fields of basic and applied science require efficiently exploring complex systems with high dimensionality. An example of such a challenge is optimising the performance of plasma fusion experiments. The highly-nonlinear and temporally-varying interaction between the plasma, its environment and external controls presents a considerable complexity in these experiments. A further difficulty arises from the fact that there is no single objective metric that fully captures both plasma quality and equipment constraints. To efficiently optimise the system, we develop the Optometrist Algorithm, a stochastic perturbation method combined with human choice. Analogous to getting an eyeglass prescription, the Optometrist Algorithm confronts a human operator with two alternative experimental settings and associated outcomes. A human operator then chooses which experiment produces subjectively better results. This innovative technique led to the discovery of an unexpected record confinement regime with positive net heating power in a field-reversed configuration plasma, characterised by a >50% reduction in the energy loss rate and concomitant increase in ion temperature and total plasma energy.

7.
Nat Commun ; 7: 13860, 2016 12 21.
Artículo en Inglés | MEDLINE | ID: mdl-28000675

RESUMEN

An economic magnetic fusion reactor favours a high ratio of plasma kinetic pressure to magnetic pressure in a well-confined, hot plasma with low thermal losses across the confining magnetic field. Field-reversed configuration (FRC) plasmas are potentially attractive as a reactor concept, achieving high plasma pressure in a simple axisymmetric geometry. Here, we show that FRC plasmas have unique, beneficial microstability properties that differ from typical regimes in toroidal confinement devices. Ion-scale fluctuations are found to be absent or strongly suppressed in the plasma core, mainly due to the large FRC ion orbits, resulting in near-classical thermal ion confinement. In the surrounding boundary layer plasma, ion- and electron-scale turbulence is observed once a critical pressure gradient is exceeded. The critical gradient increases in the presence of sheared plasma flow induced via electrostatic biasing, opening the prospect of active boundary and transport control in view of reactor requirements.

8.
Rev Sci Instrum ; 87(11): 11D435, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910371

RESUMEN

The C-2U experiment at Tri Alpha Energy studies the evolution of field-reversed configuration (FRC) plasmas sustained by neutral beam injection. Data on the FRC plasma performance are provided by a comprehensive suite of diagnostics that includes magnetic sensors, interferometry, Thomson scattering, spectroscopy, bolometry, reflectometry, neutral particle analyzers, and fusion product detectors. While many of these diagnostic systems were inherited from the preceding experiment C-2, C-2U has a variety of new and upgraded diagnostic systems: multi-chord far-infrared polarimetry, multiple fast imaging cameras with selectable atomic line filters, proton detector arrays, and 100 channel bolometer units capable of observing multiple regions of the spectrum simultaneously. In addition, extensive ongoing work focuses on advanced methods of measuring separatrix shape and plasma current profile that will facilitate equilibrium reconstruction and active control of the FRC plasma.

9.
Rev Sci Instrum ; 87(11): 11D406, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910693

RESUMEN

We have developed a compact toroid (CT) injector system for particle refueling of the advanced beam-driven C-2U field-reversed configuration (FRC) plasma. The CT injector is a magnetized coaxial plasma gun (MCPG), and the produced CT must cross the perpendicular magnetic field surrounding the FRC for the refueling of C-2U. To simulate this environment, an experimental test stand has been constructed. A transverse magnetic field of ∼1 kG is established, which is comparable to the C-2U axial magnetic field in the confinement section, and CTs are fired across it. On the test stand we have been characterizing and studying CT formation, ejection/translation from the MCPG, and penetration into transverse magnetic fields.

10.
Rev Sci Instrum ; 87(5): 053512, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-27250428

RESUMEN

A compact toroid (CT) injector was developed for the C-2 device, primarily for refueling of field-reversed configurations. The CTs are formed by a magnetized coaxial plasma gun (MCPG), which consists of coaxial cylindrical electrodes and a bias coil for creating a magnetic field. First, a plasma ring is generated by a discharge between the electrodes and is accelerated by Lorenz self-force. Then, the plasma ring is captured by an interlinkage flux (poloidal flux). Finally, the fully formed CT is ejected from the MCPG. The MCPG described herein has two gas injection ports that are arranged tangentially on the outer electrode. A tungsten-coated inner electrode has a head which can be replaced with a longer one to extend the length of the acceleration region for the CT. The developed MCPG has achieved supersonic CT velocities of ∼100 km/s. Plasma parameters for electron density, electron temperature, and the number of particles are ∼5 × 10(21) m(-3), ∼40 eV, and 0.5-1.0 × 10(19), respectively.

11.
Nat Commun ; 6: 6897, 2015 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-25902924

RESUMEN

Developing a stable plasma state with high-beta (ratio of plasma to magnetic pressures) is of critical importance for an economic magnetic fusion reactor. At the forefront of this endeavour is the field-reversed configuration. Here we demonstrate the kinetic stabilizing effect of fast ions on a disruptive magneto-hydrodynamic instability, known as a tilt mode, which poses a central obstacle to further field-reversed configuration development, by energetic beam injection. This technique, combined with the synergistic effect of active plasma boundary control, enables a fully stable ultra-high-beta (approaching 100%) plasma with a long lifetime.

12.
Rev Sci Instrum ; 85(11): 11D836, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25430249

RESUMEN

A comprehensive diagnostic suite for field-reversed configuration (FRC) plasmas has been developed and installed on the C-2 device at Tri Alpha Energy to investigate the dynamics of FRC formation as well as to understand key FRC physics properties, e.g., confinement and stability, throughout a discharge. C-2 is a unique, large compact-toroid merging device that produces FRC plasmas partially sustained for up to ∼5 ms by neutral-beam (NB) injection and end-on plasma-guns for stability control. Fundamental C-2 FRC properties are diagnosed by magnetics, interferometry, Thomson scattering, spectroscopy, bolometry, reflectometry, and NB-related fast-ion/neutral diagnostics. These diagnostics (totaling >50 systems) are essential to support the primary goal of developing a deep understanding of NB-driven FRCs.

13.
Rev Sci Instrum ; 85(11): 11D840, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25430253

RESUMEN

A versatile heterodyne Doppler Backscattering (DBS) system is used to measure density fluctuation levels (in the wavenumber range kρs ≤ 50), and the toroidal E × B flow velocity in the C-2 Field-Reversed Configuration (FRC). Six tunable frequencies in three waveguide bands (26 GHz ≤ f ≤ 90 GHz) are launched using monostatic beam optics, via a quasi-optical beam combiner/polarizer and an adjustable parabolic focusing mirror (inside the vacuum enclosure) achieving Gaussian beam spot sizes of 3-5.5 cm at the X/O-mode cutoff. The DBS system covers plasma densities of 0.8 × 10(13) ≤ ne ≤ 1 × 10(14) cm(-3), and provides access to the FRC core (up to the field null) and across the FRC separatrix into the scrape-off layer plasma.

14.
Rev Sci Instrum ; 85(2): 02B102, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24593542

RESUMEN

A 1000 keV, 5 MW, 1000 s neutral beam injector based on negative ions is being developed in the Budker Institute of Nuclear Physics, Novosibirsk in collaboration with Tri Alpha Energy, Inc. The innovative design of the injector features the spatially separated ion source and an electrostatic accelerator. Plasma or photon neutralizer and energy recuperation of the remaining ion species is employed in the injector to provide an overall energy efficiency of the system as high as 80%. A test stand for the beam acceleration is now under construction. A prototype of the negative ion beam source has been fabricated and installed at the test stand. The prototype ion source is designed to produce 120 keV, 1.5 A beam.

15.
Opt Lett ; 37(18): 3855-7, 2012 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-23041882

RESUMEN

We describe the performance of a second-harmonic interferometer (SHI) to measure, on an optical path exceeding 12 m, the electron plasma density of two plasmoids formed in separate theta-pinch chambers and then merged in a central compression chamber after undergoing acceleration and compression. The excellent mechanical stability and a time resolution better than 50 ns suggest the application of SHI, especially in pulsed plasma devices with limited optical accesses.

16.
Phys Rev Lett ; 108(25): 255008, 2012 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-23004613

RESUMEN

Field reversed configurations (FRCs) with high confinement are obtained in the C-2 device by combining plasma gun edge biasing and neutral beam injection. The plasma gun creates an inward radial electric field that counters the usual FRC spin-up. The n = 2 rotational instability is stabilized without applying quadrupole magnetic fields. The FRCs are nearly axisymmetric, which enables fast ion confinement. The plasma gun also produces E × B shear in the FRC edge layer, which may explain the observed improved particle transport. The FRC confinement times are improved by factors 2 to 4, and the plasma lifetimes are extended from 1 to up to 4 ms.

17.
Phys Rev Lett ; 105(4): 045003, 2010 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-20867853

RESUMEN

A hot stable field-reversed configuration (FRC) has been produced in the C-2 experiment by colliding and merging two high-ß plasmoids preformed by the dynamic version of field-reversed θ-pinch technology. The merging process exhibits the highest poloidal flux amplification obtained in a magnetic confinement system (over tenfold increase). Most of the kinetic energy is converted into thermal energy with total temperature (T{i}+T{e}) exceeding 0.5 keV. The final FRC state exhibits a record FRC lifetime with flux confinement approaching classical values. These findings should have significant implications for fusion research and the physics of magnetic reconnection.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...