Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Obesity (Silver Spring) ; 31 Suppl 1: 85-95, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36239695

RESUMEN

OBJECTIVE: This study explored the impact of time-restricted eating (TRE) versus standard dietary advice (SDA) on bone health. METHODS: Adults with ≥1 component of metabolic syndrome were randomized to TRE (ad libitum eating within 12 hours) or SDA (food pyramid brochure). Bone turnover markers and bone mineral content/density by dual energy x-ray absorptiometry were assessed at baseline and 6-month follow-up. Statistical analyses were performed in the total population and by weight loss response. RESULTS: In the total population (n = 42, 76% women, median age 47 years [IQR: 31-52]), there were no between-group differences (TRE vs. SDA) in any bone parameter. Among weight loss responders (≥0.6 kg weight loss), the bone resorption marker ß-carboxyterminal telopeptide of type I collagen tended to decrease after TRE but increase after SDA (between-group differences p = 0.041), whereas changes in the bone formation marker procollagen type I N-propeptide did not differ between groups. Total body bone mineral content decreased after SDA (p = 0.028) but remained unchanged after TRE (p = 0.31) in weight loss responders (between-group differences p = 0.028). Among nonresponders (<0.6 kg weight loss), there were no between-group differences in bone outcomes. CONCLUSIONS: TRE had no detrimental impact on bone health, whereas, when weight loss occurred, it was associated with some bone-sparing effects compared with SDA.


Asunto(s)
Densidad Ósea , Huesos , Adulto , Humanos , Femenino , Persona de Mediana Edad , Masculino , Densidad Ósea/fisiología , Absorciometría de Fotón , Pérdida de Peso
2.
Clin Nutr ; 41(11): 2455-2463, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36215865

RESUMEN

BACKGROUND & AIMS: The main source of error in body composition assessment of bedridden patients by bioelectrical impedance analysis (BIA) is the electrode inadequacy and placement. As electrocardiogram (ECG) electrodes are often used for BIA measurements, this study aimed to compare three of them with a reference BIA electrode. METHODS: BIA was performed sequentially on 24 healthy subjects in the supine position, using 3 different ECG electrodes (3M® Red Dot® 2330; Ambu® BlueSensor 2300; Ambu® BlueSensor SU-00-C) and the reference electrode (Bianostic AT®) for the BIA device (Nutriguard-M®, Data Input, Germany). Resistance (R), reactance (Xc), phase angle (PhA), appendicular skeletal muscle index (ASMI), fat-free mass index (FFMI) and fat mass percentage (FM%) obtained with the different electrodes were compared using Bland-Altman plots, repeated measures one-way ANOVA and paired t-test. Patient characteristics potentially involved in BIA measurement differences were assessed using linear regression analysis. RESULTS: The study population consisted of 9 men and 15 women, 33% and 47% of whom were overweight, respectively. The measured R was within the physiological range for all men (428-561 Ω) and women (472-678 Ω), regardless of the type of electrodes used. Compared to the reference electrode, the 3M® Red Dot® 2330 and Ambu® BlueSensor SU-00-C electrodes gave significantly different Xc and PhA values, but only the Ambu® BlueSensor SU-00-C gave significantly different ASMI, FFMI and FM% at 50 kHz, with biases of -0.2 kg/m2, -0.3 kg/m2 and +1.4%, respectively. The higher the current frequency, the lower was the Xc and PhA measured by the Ambu® BlueSensor SU-00-C compared to the reference electrode. These measurement differences seemed mainly due to the too small gel area of the Ambu® BlueSensor SU-00-C (154 mm2) compared to the reference electrode (1311 mm2). CONCLUSIONS: The use of electrodes with small gel area affects BIA measurement in the supine position, especially when PhA is used as an indicator of the nutritional status. Therefore, it is essential to specify the type of electrodes and carry out comparative tests before changing consumables for body composition assessment, to ensure BIA measurement reliability in clinical and research settings.


Asunto(s)
Composición Corporal , Masculino , Humanos , Femenino , Impedancia Eléctrica , Reproducibilidad de los Resultados , Posición Supina , Composición Corporal/fisiología , Electrodos , Índice de Masa Corporal , Absorciometría de Fotón
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA