Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Healthcare (Basel) ; 12(18)2024 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-39337225

RESUMEN

Aortic coarctation surgery in pediatric patients requires the placement of two arterial cannulas to monitor pressure gradients and surgical correction adequacy. Near-infrared spectroscopy (NIRS) monitoring provides insight into regional blood flow. This study aimed to investigate the correlation between NIRS values and invasive arterial pressures, exploring NIRS monitoring as a potential substitute for arterial cannulation. In a cohort of 21 consecutive pediatric patients undergoing aortic coarctation surgery, recordings of NIRS and invasive arterial pressure values were evaluated at various time intervals. Pearson correlation evaluated the relationship between NIRS values and invasively measured arterial pressures. Moderate to strong correlations were observed between the mean arterial pressure (MAP) of the upper and lower arteries and cerebral (rSO2-C) and somatic (rSO2-S) NIRS values 5 min after cross-clamp placement (r = 0.621, p = 0.003; r = 0.757, p < 0.001). Strong correlations were found 15 min after cross-clamp placement (r = 0.828, p = 0.002; r = 0.783, p = 0.004). Before transfer to the ICU, a strong correlation existed between the upper artery MAP and rSO2-C (r = 0.730, p < 0.001), but there was no correlation between the lower artery MAP and rSO2-S. These findings are promising, but further studies are required to validate it as a reliable substitute for invasive pressure monitoring in this patient population.

2.
Cardiol Young ; 33(11): 2267-2273, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36655503

RESUMEN

BACKGROUND: Balloon valvuloplasty is the primary treatment for congenital aortic valve stenosis in our centre. We sought to determine independent predictors of reintervention (surgical repair or repeated balloon dilation) after primary valvuloplasty. METHODS: We retrospectively studied patients with congenital aortic valve stenosis who underwent balloon valvuloplasty during 2004-2018. The following risk factors were analysed: aortic valve insufficiency after balloon valvuloplasty >+1/4, post-procedural gradient across the aortic valve ≥35 mmHg, pre-interventional gradient across the valve, annulus size, use of rapid pacing, and balloon/annulus ratio. Primary outcome was aortic valve reintervention. RESULTS: In total, 99 patients (median age 4 years, range 1 day to 26 years) underwent balloon valvuloplasty for congenital aortic valve stenosis. After a mean follow-up of 4.0 years, 30% had reintervention. Adjusted risks for reintervention were significantly increased in patients with post-procedural aortic insufficiency grade >+1/4 and/or residual gradient ≥35 mmHg (HR 2.55, 95% CI 1.13-5.75, p = 0.024). Pre-interventional gradient, annulus size, rapid pacing, and balloon/annulus ratio were not associated with outcome. CONCLUSION: Post-procedural aortic valve insufficiency grade >+1/4 and/or residual gradient ≥35 mmHg in patients undergoing balloon valvuloplasty for congenital aortic valve stenosis confers an increased risk for reintervention in mid-term follow-up.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Valvuloplastia con Balón , Humanos , Lactante , Recién Nacido , Resultado del Tratamiento , Estudios Retrospectivos , Dilatación , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/congénito , Válvula Aórtica/cirugía , Estudios de Seguimiento
3.
J Clin Med ; 7(12)2018 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-30513728

RESUMEN

OBJECTIVE(S): Modified ultrafiltration has gained wide acceptance as a powerful tool against cardiopulmonary bypass morbidity in pediatric cardiac surgery. The aim of our study was to assess the importance of modified ultrafiltration within conditions of contemporary cardiopulmonary bypass characteristics. METHODS: Ninety⁻eight patients (overall cohort) weighing less than 12 kg undergoing surgical repair with cardiopulmonary bypass were prospectively enrolled in a randomized protocol to receive modified and conventional ultrafiltration (MUF group) or just conventional ultrafiltration (non-MUF group). A special attention was paid to forty-nine neonates and infants weighing less than 5 kg (lower weight (LW) cohort). RESULTS: Post-filtration hematocrit was significantly higher in the MUF group for both cohorts (overall cohort p = 0.001; LW cohort p = 0.04), but not at other time points. During the postoperative course, patients in the MUF group received fewer packed red blood cells, (overall cohort p = 0.01; LW cohort p = 0.07), but required more fresh frozen plasma (overall cohort p = 0.04; LW cohort p = 0.05). There was no difference between groups in hemodynamic state, chest tube output, duration of mechanical ventilation, respiratory parameters, duration of intensive care unit, and hospitalization stay. CONCLUSIONS: If conventional ultrafiltration provides adequate hemoconcentration modified ultrafiltration does not provide additional positive benefits except for reduction in blood cell transfusion, This, however, comes at the cost of needing more fresh frozen plasma. Of particular importance is that this also applies to infants with weight bellow 5 kg where modified ultrafiltration was supposed to have the greatest positive impact.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...