Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
AJNR Am J Neuroradiol ; 43(11): 1621-1626, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36202555

RESUMEN

BACKGROUND AND PURPOSE: Patients with acute ischemic stroke are increasingly triaged with one-stop management approaches, resulting in baseline imaging with a flat detector CT scanner. This study aimed to estimate the effective dose to a patient of a novel cervical and intracranial flat detector CT angiography and a flat detector CT perfusion protocol and to compare it with the effective dose of analogous multidetector row CT protocols. MATERIALS AND METHODS: We estimated the effective dose to the patient according to the International Commission on Radiological Protection 103 using an anthropomorphic phantom with metal oxide semiconductor field effect transistor dosimeters. Placement was according to the organ map provided by the phantom manufacturer. We used 100 measurement points within the phantom, and 18 metal oxide semiconductor field effect transistor dosimeters were placed on the surface of the phantom. All protocols followed the manufacturer's specifications, and patient positioning and collimation were performed as in routine clinical practice. Measurements were obtained on the latest-generation angiography and multidetector row CT systems with identical placement of the metal oxide semiconductor field effect transistor dosimeters. RESULTS: The estimated effective doses of the investigated perfusion protocols were 4.52 mSv (flat detector CT perfusion without collimation), 2.88 mSv (flat detector CT perfusion with collimation), and 2.17 mSv (multidetector row CT perfusion). A novel protocol called portrait flat detector CT angiography that has a z-axis coverage area comparable with that of multidetector row CT angiography had an estimated effective dose of 0.91 mSv, while the dose from multidetector row CT was 1.35 mSv. CONCLUSIONS: The estimated effective dose to the patient for flat detector CT perfusion and angiography on a modern biplane angiography system does not deviate substantially from that of analogous multidetector row CT protocols.


Asunto(s)
Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Dosis de Radiación , Fantasmas de Imagen , Angiografía/métodos , Tomografía Computarizada Multidetector , Accidente Cerebrovascular/diagnóstico por imagen , Óxidos
2.
CVIR Endovasc ; 4(1): 74, 2021 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-34633563

RESUMEN

PURPOSE: The current literature on the use of brachial artery access is controversial. Some studies found increased puncture site complications. Others found no higher complication rates than in patients with femoral or radial access. The purpose of this study was to determine the impact of ultrasound (US)-guidance on access site complications. MATERIALS AND METHODS: This is a single-center retrospective study of all consecutive patients with brachial arterial access for interventional procedures. Complications were classified into minor complications (conservative treatment only) and major complications (requiring surgical intervention). The brachial artery was cannulated in the antecubital fossa under US-guidance. After the intervention, manual compression or closure devices, both followed by a compression bandage for 3 h, either achieved hemostasis. RESULTS: Seventy-five procedures in seventy-one patients were performed in the study period using brachial access. Access was successful in all cases (100%). Procedures in different vascular territories were performed: neurovascular (10/13.5%), upper extremity (32/43.2%), visceral (20/27.0%), and lower extremity (12/16.3%). Sheath size ranged from 3.2F to 8F (mean: 5F). Closure devices were used in 17 cases (22.7%). In total, six complications were observed (8.0%), four minor complications (5.3%, mostly puncture site hematomas), and two major complications, that needed surgical treatment (2.7%). No brachial artery thrombosis or upper extremity ischemia occurred. CONCLUSION: Exclusive use of US-guidance resulted in a low risk of brachial artery access site complications in our study compared to the literature. US-guidance has been proven to reduce the risk of access site complications in several studies in femoral access. In addition, brachial artery access yields a high technical success rate and requires no additional injection of spasmolytic medication. Sheath size was the single significant predictor for complications.

3.
AJNR Am J Neuroradiol ; 41(3): 464-468, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32029470

RESUMEN

BACKGROUND AND PURPOSE: Large intracranial vessel occlusion due to calcified emboli is a rare cause of major stroke. We assessed the prevalence, imaging appearance, the effectiveness of mechanical thrombectomy, and clinical outcome of patients with large-vessel occlusion due to calcified emboli. MATERIALS AND METHODS: We performed a retrospective analysis of clinical and procedural data of consecutive patients who underwent mechanical thrombectomy due to calcified emboli in 7 European stroke centers. RESULTS: We screened 2969 patients, and 40 patients matched the inclusion criteria, accounting for a prevalence of 1.3%. The mean maximal density of the thrombus was 327 HU (range, 150-1200 HU), and the mean thrombus length was 9.2 mm (range, 4-20 mm). Four patients had multiple calcified emboli, and 2 patients had an embolic event during an endovascular intervention. A modified TICI score of ≥2b was achieved in 57.5% (23/40), with minimal-to-no reperfusion (modified TICI 0-1) in 32.5% (13/40) and incomplete reperfusion (modified TICI 2a) in 10% (4/40). Excellent outcome (mRS 0-1) was achieved in only 20.6%, functional independence (mRS 0-2) in 26.5% and 90-day mortality was 55.9%. CONCLUSIONS: Acute ischemic stroke with large-vessel occlusion due to calcified emboli is a rare entity in patients undergoing thrombectomy, with considerably worse angiographic outcome and a higher mortality compared with patients with noncalcified thrombi. Good functional recovery at 3 months can still be achieved in about a quarter of patients.


Asunto(s)
Embolia/patología , Embolia/cirugía , Procedimientos Endovasculares/métodos , Accidente Cerebrovascular/cirugía , Trombectomía/métodos , Adulto , Anciano , Anciano de 80 o más Años , Isquemia Encefálica/etiología , Isquemia Encefálica/cirugía , Calcinosis/patología , Calcinosis/cirugía , Embolia/complicaciones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recuperación de la Función , Reperfusión/métodos , Estudios Retrospectivos , Accidente Cerebrovascular/etiología , Resultado del Tratamiento
4.
AJNR Am J Neuroradiol ; 41(2): 293-299, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31879333

RESUMEN

Reversible vasoconstriction syndrome is a complex of clinical symptoms and angiographic findings, which, while having a mostly benign clinical course, has clinical and imaging overlap with more serious disorders such as vasculitis and aneurysmal SAH and itself includes a minority of patients with fulminant vasoconstriction resulting in severe intracranial complications. Endovascular options for patients with refractory reversible cerebral vasoconstriction syndrome include intra-arterial vasodilator infusion similar to therapy for patients with vasospasm after SAH. To date, only case reports and 1 small series have discussed the utility of intra-arterial vasodilators for the treatment of reversible cerebral vasoconstriction syndrome. We report an additional series of 11 medically refractory cases of presumed or proved reversible cerebral vasoconstriction syndrome successfully treated with intra-arterial verapamil infusion. Furthermore, we propose that the reversal of vasoconstriction, as seen on angiography, could fulfill a diagnostic criterion.


Asunto(s)
Trastornos Cerebrovasculares/tratamiento farmacológico , Vasoconstricción/efectos de los fármacos , Vasodilatadores/administración & dosificación , Vasoespasmo Intracraneal/tratamiento farmacológico , Verapamilo/administración & dosificación , Adulto , Anciano , Femenino , Humanos , Infusiones Intraarteriales , Masculino , Persona de Mediana Edad
5.
AJNR Am J Neuroradiol ; 40(3): 524-530, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30733254

RESUMEN

BACKGROUND AND PURPOSE: The Sim&Size software simulates case-specific intraluminal Pipeline Embolization Device behavior, wall apposition, and device length in real-time on the basis of rotational angiography DICOM data. The purpose of this multicenter study was to evaluate whether preimplantation device simulation with the Sim&Size software results in selection of different device dimensions than manual sizing. MATERIALS AND METHODS: In a multicenter cohort of 74 patients undergoing aneurysm treatment with the Pipeline Embolization Device, we compared apparent optimal device dimensions determined by neurointerventionalists with considerable Pipeline Embolization Device experience based on manual 2D measurements taken from rotational angiography with computed optimal dimensions determined by Sim&Size experts blinded to the neurointerventionalists' decision. Agreement between manually determined and computed optimal dimensions was evaluated with the Cohen κ. The significance of the difference was analyzed with the Wilcoxon signed rank test. RESULTS: The agreement index between manual selection and computed optimal dimensions was low (κ for diameter = 0.219; κ for length = 0.149, P < .01). Computed optimal device lengths were significantly shorter (median, 14 versus 16 mm, T = 402, r = -0.28, P < .01). No significant difference was observed for device diameters. CONCLUSIONS: Low agreement between manually determined and computed optimal device dimensions is not proof, per se, that virtual simulation performs better than manual selection. Nevertheless, it ultimately reflects the potential for optimization of the device-sizing process, and use of the Sim&Size software reduces, in particular, device length. Nevertheless, further evaluation is required to clarify the impact of device-dimension modifications on outcome.


Asunto(s)
Simulación por Computador , Embolización Terapéutica/instrumentación , Aneurisma Intracraneal/terapia , Programas Informáticos , Anciano , Prótesis Vascular , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
6.
J Neurointerv Surg ; 4(2): 87-93, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22278933

RESUMEN

OBJECTIVE: To summarize and classify the evidence for the use of endovascular techniques in the treatment of patients with acute ischemic stroke. METHODS: Recommendations previously published by the American Heart Association (AHA) (Guidelines for the early management of adults with ischemic stroke (Circulation 2007) and Scientific statement indications for the performance of intracranial endovascular neurointerventional procedures (Circulation 2009)) were vetted and used as a foundation for the current process. Building on this foundation, a critical review of the literature was performed to evaluate evidence supporting the endovascular treatment of acute ischemic stroke. The assessment was based on guidelines for evidence based medicine proposed by the Stroke Council of the AHA and the University of Oxford, Centre for Evidence Based Medicine (CEBM). Procedural safety, technical efficacy and impact on patient outcomes were specifically examined.


Asunto(s)
Isquemia Encefálica/terapia , Procedimientos Endovasculares/normas , Accidente Cerebrovascular/terapia , Terapia Trombolítica/normas , American Heart Association , Isquemia Encefálica/tratamiento farmacológico , Isquemia Encefálica/cirugía , Angiografía Cerebral , Terapia Combinada , Procedimientos Endovasculares/clasificación , Procedimientos Endovasculares/instrumentación , Fibrinolíticos/uso terapéutico , Humanos , Guías de Práctica Clínica como Asunto , Informe de Investigación , Sociedades Médicas/normas , Accidente Cerebrovascular/tratamiento farmacológico , Accidente Cerebrovascular/cirugía , Terapia Trombolítica/clasificación , Estados Unidos
7.
J Neurointerv Surg ; 4(1): 11-5, 2012 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-22166819

RESUMEN

This is the first in a set of documents intended to standardize techniques, procedures, and practices in the field of endovascular surgical neuroradiology. Standards are meant to define core practices for peer review, comparison, and improvement. Standards and guidelines also form the basic dialogue, reporting, and recommendations for ongoing practices and future development.


Asunto(s)
Procedimientos Endovasculares/normas , Procedimientos Neuroquirúrgicos/normas , Guías de Práctica Clínica como Asunto/normas , Sociedades Médicas/normas , Procedimientos Endovasculares/tendencias , Humanos , Procedimientos Neuroquirúrgicos/tendencias , Sociedades Médicas/tendencias , Nivel de Atención/normas , Nivel de Atención/tendencias
8.
AJNR Am J Neuroradiol ; 33(1): 77-82, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22095963

RESUMEN

BACKGROUND AND PURPOSE: MR imaging of moving patients can be challenging and motion correction techniques have been proposed though some have associated new artifacts. The objective of this study was to semiquantitatively compare brain MR images of moving patients obtained at 1.5T by using partially radial and rectilinear acquisition techniques. MATERIALS AND METHODS: FLAIR, T2-, T1-, and contrast-enhanced T1-weighted image sets of 25 patients (14-94 years) obtained by using BLADE (like PROPELLER, a partially radial acquisition) and rectilinear techniques in the same imaging session were compared by 2 neuroradiologists in terms of extent of the motion artifact, image quality, and lesion visibility. ICC between opinions of the evaluators was calculated. RESULTS: Of the total of 70 image sets, the motion artifact was small in the partially radial images in 43 and in the rectilinear images in 13, and the opinions of the evaluators were discordant in the remaining 14 sets (ICC = 0.63, P < .05). The quality of partially radial images was higher for 36 sets versus 9 rectilinear sets, with disagreement between the 2 evaluators in the remaining 25 (ICC = 0.15, P < .05). Pathologic lesions were better characterized on 37 sets of partially radial images versus 13 sets of rectilinear images, and opinions of the evaluators differed in 20 sets (ICC = 0.90, P < .05). The neuroradiologists deemed 4 sets of rectilinear images nondiagnostic compared with only 1 set of radial images. CONCLUSIONS: The data demonstrate that our application of BLADE sequences reduces the extent of motion artifacts in brain images of moving patients, improving image quality and lesion characterization.


Asunto(s)
Algoritmos , Artefactos , Encéfalo/patología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Movimiento , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
9.
AJNR Am J Neuroradiol ; 32(2): 365-73, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21163877

RESUMEN

BACKGROUND AND PURPOSE: Multichannel phased-array head coils are undergoing exponential escalation of coil element numbers. While previous technical studies have found gains in SNR and spatial resolution with the addition of element coils, it remains to be determined how these gains affect clinical reading. The purpose of this clinical study was to determine if the SNR and spatial resolution characteristics of a 32-channel head coil result in improvements in perceived image quality and lesion evaluation. MATERIALS AND METHODS: Twenty-one patients underwent MR imaging of the brain at 1.5T sequentially with both a 12-channel and a 32-channel receive-only phased-array head coil. Axial T2WIs, T1WIs, FLAIR images, and DWIs were acquired. Anonymized images were compared side-by-side and by sequence for image quality, lesion evaluation, and artifacts by 3 neuroradiologists. Results of the comparison were analyzed for the preference for a specific head coil. RESULTS: FLAIR and DWI images acquired with the 32-channel coil showed significant improvement in image quality in several parameters. T2WIs also improved significantly with acquisition by the 32-channel coil, while T1WIs improved in a limited number of parameters. While lesion evaluation also improved with acquisition of images by the 32-channel coil, there was no apparent improvement in diagnostic quality. There was no difference in artifacts between the 2 coils. CONCLUSIONS: Improvements in SNR and spatial resolution attributed to image acquisition with a 32-channel head coil are paralleled by perceived improvements in image quality.


Asunto(s)
Encefalopatías/patología , Imagen de Difusión por Resonancia Magnética/instrumentación , Imagen de Difusión por Resonancia Magnética/métodos , Artefactos , Ganglios Basales/patología , Tronco Encefálico/patología , Cerebelo/patología , Corteza Cerebral/patología , Imagen de Difusión por Resonancia Magnética/normas , Femenino , Humanos , Cápsula Interna/patología , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...