Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
1.
Ann Thorac Surg ; 2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38904587

RESUMEN

BACKGROUND: Although coarctation of the aorta without concomitant intracardiac pathology is relatively common, there is lack of guidance regarding aspects of its management in neonates and infants. METHODS: A panel of experienced congenital cardiac surgeons, cardiologists, and intensivists was created, and key questions related to the management of isolated coarctation in neonates and infants were formed using the PICO (Patients/Population, Intervention, Comparison/Control, Outcome) Framework. A literature search was then performed for each question. Practice guidelines were developed with classification of recommendation and level of evidence using a modified Delphi method. RESULTS: For neonates and infants with isolated coarctation, surgery is indicated in the absence of obvious surgical contraindications. For patients with risk factors for surgery, medical management before intervention is reasonable. For those stable off prostaglandin E1, the threshold for intervention remains unclear. Thoracotomy is indicated when arch hypoplasia is not present. Sternotomy is preferable when arch hypoplasia is present that cannot be adequately addressed through a thoracotomy. Sternotomy may also be considered in the presence of a bovine aortic arch. Antegrade cerebral perfusion may be reasonable when the repair is performed through a sternotomy. Extended end-to-end, arch advancement, and patch augmentation are all reasonable techniques. CONCLUSIONS: Surgery remains the standard of care for the management of isolated coarctation in neonates and infants. Depending on degree and location, arch hypoplasia may require a sternotomy approach as opposed to a thoracotomy approach. Significant opportunities remain to better delineate management in these patients.

2.
Perfusion ; : 2676591241236645, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38804020

RESUMEN

PURPOSE: The purpose of this study was to compare techniques for securing the aortic extracorporeal membrane oxygenation (ECMO) cannula, using in vitro models. METHODS: Two models were studied: a tissue model using porcine aortas and a stand model replacing the aorta with a metal stand to study the system independent of the tissue. Interventions in each model were divided into three experimental groups: Group 1 (3-0 Prolene® + 20-French Medtronic Arterial Cannula EOPA™), Group 2 (4-0 Prolene® + 16-French Medtronic Arterial Cannula DLP Pediatric), and Group 3 (5-0 Prolene® + 8-French Medtronic Arterial Cannula DLP Pediatric). In separate experiments, both gradual and rapid forces were applied to the cannulas, starting with 9.8 Newtons and increasing exponentially if the cannula remained secured. Additionally, the method of securing the tourniquet and the number of ties securing the tourniquet to the cannula were evaluated. RESULTS: In the tissue model, even with a minimum force of 9.8 Newtons, the suture pulled through the aortic tissue, leaving sutures and ties intact. In the stand model, two purse-string sutures secured by two ligaclips held the cannula reliably and withstood higher total force. Dislodgement was prevented at forces close to 60 Newtons with only two hemostatic clips included in cannulation. CONCLUSIONS: The weakest part of the aortic ECMO cannulation system using in vitro experiments was the tissue. Assuming that these experiments translate in vivo, it is therefore critical to prevent any pull on the cannulas by securing ECMO cannulas and ECMO tubing to both the patient and the patient's bed. Sutures with a larger diameter withstand more force. Two medium hemostatic clips can secure Prolene® sutures within snares as safely as a mosquito hemostat. Two polypropylene purse-string sutures secured by two hemostatic clips were most reliable at greater forces. The rationale for publishing our experiments in this manuscript is to (1) communicate our quantification of possible contributing factors to this rare and likely catastrophic complication of unintended decannulation, (2) increase awareness about this potential complication, and (3) increase vigilance to assure prevention of this dreaded complication.

3.
Ann Thorac Surg ; 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38777247

RESUMEN

BACKGROUND: This study examines 36 years of national pediatric heart transplantation data to 1) identify trends in transplant volume, centers, and one-year graft survival, and 2) assess how center transplant volume impacts outcomes over a contemporary 11-year period. METHODS: We performed a retrospective review of pediatric patients (<18 years) undergoing heart transplantation from 1/1/1987 to 12/31/2022 using the United Network for Organ Sharing Database. Trend analyses included the whole cohort, while volume-outcome analyses included a contemporary cohort to account for the temporal changes observed in transplant survival. Highest volume centers were defined by the number of heart transplants performed per center per year. RESULTS: Over 36 years, 11,828 pediatric heart transplants were performed. Transplant volume steadily rose, the number of centers remained stable, and one-year graft survival has improved significantly. In the contemporary era (2012-2022), 89 centers conducted 4,959 pediatric heart transplants. The top 15% high-volume centers (13 centers) accounted for 48.3% (2,393) of transplants, with an average of 16.7±3.8 transplants per center annually, compared to 3.9±3.1 for lower volume centers. Despite transplanting higher risk patients, high-volume centers had similar postoperative outcomes and improved long-term survival. CONCLUSIONS: While the number of US pediatric heart transplant centers has remained stable, pediatric heart transplant volume is steadily increasing, as is one-year graft survival. In a contemporary cohort, the top 15th percentile highest volume centers accounted for 48.3% of US pediatric heart transplants and transplanted higher risk patients with similar postoperative outcomes and improved longitudinal survival.

4.
Pediatr Neurol ; 155: 133-140, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38640862

RESUMEN

BACKGROUND: Children with congenital heart disease (CHD) have a higher prevalence of motor impairment secondary to brain injury, resulting in cerebral palsy (CP). The purpose of this study is to determine the prevalence of CP in CHD in a single-center cohort, stratify risk based on surgical mortality using Society of Thoracic Surgeons-European Association for Cardio-Thoracic Surgery (STAT) categories and identify risk factors. METHODS: Retrospective cohort study of pediatric patients registered in the University of Florida (UF) Society of Thoracic Surgeons Congenital Heart Surgery database from 2006 to 2017 with a diagnosis of CHD who continued follow-up for more than two years at UF. RESULTS: A total of 701 children with CHD met inclusion criteria. Children identified to have CP were 54 (7.7%). Most common presentation was spastic hemiplegic CP with a Gross Motor Function Classification System of level 2. Analysis of surgical and intensive care factors between the two groups showed that children with CHD and CP had longer time from admission to surgery (P = 0.003), higher STAT categories 4 and 5 (P = 0.038), and higher frequency of brain injury and seizures (P < 0.001). Developmental disabilities and rehabilitation needs were significantly greater for children with CHD and CP when compared with those with CHD alone (P < 0.001). CONCLUSIONS: In our cohort, 7.7% children with CHD develop CP; this is significantly higher than the 2010 US population estimate of 0.3%. Our study suggests higher STAT categories, brain injury, and seizures are associated with developing CP in children with CHD.


Asunto(s)
Parálisis Cerebral , Cardiopatías Congénitas , Humanos , Parálisis Cerebral/epidemiología , Parálisis Cerebral/complicaciones , Parálisis Cerebral/etiología , Masculino , Femenino , Cardiopatías Congénitas/cirugía , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/mortalidad , Estudios Retrospectivos , Prevalencia , Factores de Riesgo , Lactante , Preescolar , Niño , Adolescente
5.
Pediatr Cardiol ; 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38557773

RESUMEN

A variety of surgical approaches exist to treat aortic coarctation in neonates and infants. Our institutional approach is designed to match the surgical approach to the individual anatomy of the patient. The objective of this study is to evaluate operative characteristics and outcomes of all neonates and infants who underwent surgical repair of coarctation of the aorta or hypoplastic aortic arch at University of Florida from 2006 to 2021, inclusive, either in isolation or with concomitant repair of atrial septal defect (ASD) and/or ventricular septal defect (VSD). A retrospective review was performed of 132 patients aged 0-1 year who underwent surgical repair of aortic coarctation or hypoplastic aortic arch between 2006 and 2021, inclusive, either in isolation or with concomitant repair of ASD and/or VSD. Patients were divided into two groups based on the surgical approach: Group 1 = Median Sternotomy and Group 2 = Left Lateral Thoracotomy. Continuous variables are presented as median (minimum-maximum); categorical variables are presented as N (%). The most common operative technique in Group 1 was end-to-side reconstruction with ligation of the aortic isthmus. The most common operative technique in Group 2 was extended end-to-end repair. Operative Mortality was one patient (1/132 = 0.76%). Transcatheter intervention for recurrent coarctation was performed in seven patients (7/132 = 5.3%). Surgical re-intervention for recurrent coarctation was performed in three patients (3/132 = 2.3%). From these data, one can conclude that a strategy of matching the surgical approach to the anatomy of neonates and infants who underwent surgical repair of aortic coarctation or hypoplastic aortic arch, either in isolation or with concomitant repair of ASD and/or VSD, is associated with less than 1% Operative Mortality and less than 3% recurrent coarctation requiring reoperation.

6.
Perfusion ; : 2676591241246079, 2024 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-38581646

RESUMEN

Background: Nitric Oxide (NO) is a naturally occurring modulator of inflammation found in the human body. Several studies in the pediatric cardiothoracic surgery literature have demonstrated some beneficial clinical effects when NO is added to the sweep gas of the cardiopulmonary bypass circuit.Purpose: Our primary aim was to determine the safety of incorporating nitric oxide into the oxygenator sweep gas of the extracorporeal membrane oxygenation (ECMO) circuit. Secondarily, we looked at important clinical outcomes, such as survival, blood product utilization, and common complications related to ECMO.Methods: We performed a single center, retrospective review of all patients at our institution who received ECMO between January 1, 2017 and March 31, 2023. We began additing NO to the ECMO sweep gas in 2019. Results: There were no instances of clinically significant methemoglobinemia with the addition of NO to the sweep gas (0% vs 0%, p = 1). The median daily methemoglobin level was higher in those who received NO via the sweep gas when compared to those who did not (1.6 vs 1.1, p = <0.001). Conclusions: The addition of NO to the sweep gas of the ECMO circuit is safe.

7.
Cardiol Young ; : 1-8, 2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-38362907

RESUMEN

OBJECTIVES: We reviewed outcomes in all 36 consecutive children <5 kg supported with the Berlin Heart pulsatile ventricular assist device at the University of Florida, comparing those with acquired heart disease (n = 8) to those with congenital heart disease (CHD) (n = 28). METHODS: The primary outcome was mortality. The Kaplan-Meier method and log-rank tests were used to assess group differences in long-term survival after ventricular assist device insertion. T-tests using estimated survival proportions were used to compare groups at specific time points. RESULTS: Of 82 patients supported with the Berlin Heart at our institution, 49 (49/82 = 59.76%) weighed <10 kg and 36 (36/82 = 43.90%) weighed <5 kg. Of 36 patients <5 kg, 26 (26/36 = 72.22%) were successfully bridged to transplantation. (The duration of support with ventricular assist device for these 36 patients <5 kg was [days]: median = 109, range = 4-305.) Eight out of 36 patients <5 kg had acquired heart disease, and all eight [8/8 = 100%] were successfully bridged to transplantation. (The duration of support with ventricular assist device for these 8 patients <5 kg with acquired heart disease was [days]: median = 50, range = 9-130.) Twenty-eight of 36 patients <5 kg had congenital heart disease. Eighteen of these 28 [64.3%] were successfully bridged to transplantation. (The duration of support with ventricular assist device for these 28 patients <5 kg with congenital heart disease was [days]: median = 136, range = 4-305.) For all 36 patients who weighed <5 kg: 1-year survival estimate after ventricular assist device insertion = 62.7% (95% confidence interval = 48.5-81.2%) and 5-year survival estimate after ventricular assist device insertion = 58.5% (95% confidence interval = 43.8-78.3%). One-year survival after ventricular assist device insertion = 87.5% (95% confidence interval = 67.3-99.9%) in acquired heart disease and 55.6% (95% confidence interval = 39.5-78.2%) in CHD, P = 0.036. Five-year survival after ventricular assist device insertion = 87.5% (95% confidence interval = 67.3-99.9%) in acquired heart disease and 48.6% (95% confidence interval = 31.6-74.8%) in CHD, P = 0.014. CONCLUSION: Pulsatile ventricular assist device facilitates bridge to transplantation in neonates and infants weighing <5 kg; however, survival after ventricular assist device insertion in these small patients is less in those with CHD in comparison to those with acquired heart disease.

8.
Perfusion ; : 2676591241226464, 2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38391296

RESUMEN

BACKGROUND: Our team previously identified a stem cell-derived cardioprotective additive that can be added to standard cardioplegia to extend myocardial viability during prolonged myocardial cold ischemic time (CIT) in rodent models. The purpose of this study was to utilize a porcine model to compare in-vivo versus ex-vivo porcine simulation of CIT that accompanies cardiac transplantation in humans, in order to determine an optimal method for translation of our studies to larger animals. METHODS: Eight 39-55 kg Yorkshire X pigs were randomly assigned to either in-vivo or ex-vivo simulation. After administration of general anesthesia and endotracheal intubation, baseline measurement of left ventricular performance was obtained via transesophageal echocardiography (TEE). After midline sternotomy and heparin administration, the aorta was cross-clamped and two liters of HTK-Custodiol were introduced via the aortic root. The in-vivo method utilized cold ischemic heart storage in the chest cavity while supporting the experimental animal with cardiopulmonary bypass (CPB). The ex-vivo method involved standard cardiac procurement, cold ischemic storage outside of the body, and subsequent cardiac reperfusion utilizing cardiac reanimation in a Langendorff heart perfusion mode. After CIT, measurements of post-ischemic left ventricular performance were obtained via echocardiography. Results are presented as: Mean ± Standard Deviation (Median, Minimum-Maximum). RESULTS: Weight (kilograms) was similar in the in-vivo group and the ex-vivo group: 44 ± 1.8 (44, 42-46) versus 44 ± 5.1 (43.5, 39-51), respectively. Cold ischemic time (minutes) was longer in the ex-vivo group: 360 ± 0 (360, 360-360) versus 141 ± 26.7 (149, 102-163). Temperature (degrees Celsius) was colder in the ex-vivo group: 8 ± 0 (8, 8-8) versus 16.5 ± 4.2 (16, 12-16).In the in-vivo group, baseline ejection fraction and ejection fraction after CIT were: 48.25% ± 14.95% (48.5%, 33%-63%) and 41.25% ± 22.32% (41.5%, 20%-62%), respectively. In the ex-vivo group, baseline ejection fraction and ejection fraction after CIT were: 56.4% ± 5.9% (57%, 50%-67%) and 60.4% ± 7.7% (61.5%, 51.9%-67%), respectively. CONCLUSION: The ex-vivo technique is suitable to evaluate cardioplegia additives that may substantially extend myocardial tolerance to cold ischemia.

9.
Pediatr Transplant ; 28(2): e14707, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38419558

RESUMEN

Epstein-Barr Virus (EBV) is a ubiquitous herpes type virus that is associated with post-transplant lymphoproliferative disorder (PTLD). Usual management includes reduction or cessation of immunosuppression and in some cases chemotherapy including rituximab. However, limited therapies are available if PTLD is refractory to rituximab. Several clinical trials have investigated the use of EBV-directed T cells in rituximab-refractory patients; however, data regarding response is scarce and inconclusive. Herein, we describe a patient with EBV-PTLD refractory to rituximab after orthotopic heart transplantation (OHT) requiring EBV-directed T-cell therapy. This article aims to highlight the unique and aggressive clinical presentation and progression of PTLD with utilization of EBV-directed T-cell therapy for management and associated pitfalls.


Asunto(s)
Infecciones por Virus de Epstein-Barr , Trasplante de Corazón , Trasplante de Células Madre Hematopoyéticas , Trastornos Linfoproliferativos , Humanos , Preescolar , Herpesvirus Humano 4 , Rituximab/uso terapéutico , Infecciones por Virus de Epstein-Barr/terapia , Infecciones por Virus de Epstein-Barr/tratamiento farmacológico , Trastornos Linfoproliferativos/diagnóstico , Trastornos Linfoproliferativos/etiología , Trastornos Linfoproliferativos/terapia , Tratamiento Basado en Trasplante de Células y Tejidos
13.
J Neuroimmunol ; 385: 578239, 2023 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-37976996

RESUMEN

OBJECTIVES: Serum biomarkers for brain injury in neonates with congenital heart disease (CHD) provide a bedside tool for early identification and intervention. In this preliminary study, we aim to evaluate IL-18, Eotaxin-1 and Eotaxin-3 as biomarkers for the detection of brain injury in neonates with CHD. METHODS: We prospectively enrolled seven neonates diagnosed in-utero with CHD and obtained serum samples at birth, before and after surgery. Samples were analyzed using a human cytokine/chemokine multiplex assay. Brain injury was diagnosed on brain MRI before surgery. RESULTS: Samples from seven neonates at four time points before surgery and three time points after surgery were analyzed. A significant difference was found in neonates with brain injury compared to CHD neonates without. Elevations in interleukin (IL)-18 pre- and post-operative (p = 0.007), IL-18 pre-operative (p = 0.046), Eotaxin-1 pre-operative (p = 0.011), and Eotaxin-3 pre- and post-operative (p = 0.026) were found in CHD neonates with brain injury. CONCLUSION: This is the first published report on the use IL-18, Eotaxin-1, and Eotaxin-3 in the detection of brain injury for neonates with CHD. These biomarkers may provide an actionable target for neuroprotection through immunomodulation. Larger cohorts are needed to determine the significance and clinical utility of these biomarkers.


Asunto(s)
Lesiones Encefálicas , Cardiopatías Congénitas , Recién Nacido , Humanos , Interleucina-18 , Quimiocina CCL11 , Quimiocina CCL26 , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/cirugía , Biomarcadores
14.
World J Pediatr Congenit Heart Surg ; 14(6): 741-745, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37933696

RESUMEN

The 2021 International Paediatric and Congenital Cardiac Code and the Eleventh Revision of the International Classification of Diseases provide the following definition for hypoplastic left heart syndrome (HLHS): "Hypoplastic left heart syndrome (HLHS) is defined as a spectrum of congenital cardiovascular malformations with normally aligned great arteries without a common atrioventricular junction, characterized by underdevelopment of the left heart with significant hypoplasia of the left ventricle including atresia, stenosis, or hypoplasia of the aortic or mitral valve, or both valves, and hypoplasia of the ascending aorta and aortic arch." Although HLHS with intact ventricular septum (HLHS + IVS) and HLHS with ventricular septal defect (HLHS + VSD) are different cardiac phenotypes, both of these lesions are part of the spectrum of HLHS.


Asunto(s)
Cardiopatías Congénitas , Defectos del Tabique Interventricular , Síndrome del Corazón Izquierdo Hipoplásico , Humanos , Niño , Válvula Mitral/patología , Ventrículos Cardíacos/anomalías
15.
World J Pediatr Congenit Heart Surg ; 14(6): 708-715, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37609822

RESUMEN

BACKGROUND: We reviewed the outcomes of 82 consecutive pediatric patients (less than 18 years of age) supported with the Berlin Heart ventricular assist device (VAD), comparing those with congenital heart disease (CHD; n = 44) with those with acquired heart disease (AHD; n = 37). METHODS: The primary outcome was mortality after VAD insertion. Kaplan-Meier methods and log-rank tests were used to assess group differences in long-term survival. RESULTS: Forty-four CHD patients were supported (age: median = 65 days, range = 4 days-13.3 years; weight [kg]: median = 4, range = 2.4-42.3). Ten biventricular CHD patients were supported with eight biventricular assist devices (BiVADs), one left ventricular assist device (LVAD) only, and one LVAD converted to BiVAD, while 34 univentricular CHD patients were supported with single ventricle-ventricular assist devices (sVADs). In CHD patients, duration of VAD support was [days]: median = 134, range = 4-554. Of 44 CHD patients, 28 underwent heart transplantation, 15 died on VAD, and one was still on VAD. Thirty-seven AHD patients were supported (age: median = 1.9 years, range = 27 days-17.7 years; weight [kg]: median = 11, range = 3.1-112), including 34 BiVAD and 3 LVAD. In AHD patients, duration of VAD support was [days]: median = 97, range = 4-315. Of 37 AHD patients, 28 underwent transplantation, three died on VAD, five weaned off VAD (one of whom underwent heart transplantation 334 days after weaning), and one was still on VAD. One-year survival after VAD insertion was 59.9% (95% CI = 46.7%-76.7%) in CHD and 88.6% (95% CI = 78.8%-99.8%) in AHD, P = .0004. Five-year survival after VAD insertion was 55.4% (95% CI = 40.8%-75.2%) in CHD and 85.3% (95% CI = 74.0%-98.2%) in AHD, P = .002. CONCLUSIONS: Pulsatile VAD facilitates bridge-to-transplantation in neonates, infants, and children with CHD; however, survival after VAD insertion is worse in patients with CHD than in patients with AHD.


Asunto(s)
Cardiopatías Congénitas , Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Lactante , Recién Nacido , Niño , Humanos , Resultado del Tratamiento , Ventrículos Cardíacos , Estudios Retrospectivos
16.
Cardiol Young ; 33(7): 1079-1085, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37605817

RESUMEN

PURPOSE: Publicly available health information is increasingly important for patients and their families. While the average US citizen reads at an 8th-grade level, electronic educational materials for patients and families are often advanced. We assessed the quality and readability of publicly available resources regarding hypoplastic left heart syndrome (HLHS). METHODS: We queried four search engines for "hypoplastic left heart syndrome", "HLHS", and "hypoplastic left ventricle". The top 30 websites from searches on Google, Yahoo!, Bing, and Dogpile were combined into a single list. Duplicates, commercial websites, physician-oriented resources, disability websites, and broken links were removed. Websites were graded for accountability, content, interactivity, and structure using a two-reviewer system. Nonparametric analysis of variance was performed. RESULTS: Fifty-two websites were analysed. Inter-rater agreement was high (Kappa = 0.874). Website types included 35 hospital/healthcare organisation (67.3%), 12 open access (23.1%), 4 governmental agency (7.7%), and 1 professional medical society (1.9%). Median total score was 19 of 39 (interquartile range = 15.8-25.3): accountability 5.5 of 17 (interquartile range = 2.0-9.3), content 8 of 12 (interquartile range = 6.4-10.0), interactivity 2 of 6 (interquartile range = 2.0-3.0), and structure 3 of 4 (interquartile range = 2.8-4.0). Accountability was low with 32.7% (n = 17) of sites disclosing authorship and 26.9% (n = 14) citing sources. Forty-two percent (n = 22) of websites were available in Spanish. Total score varied by website type (p = 0.03), with open access sites scoring highest (median = 26.5; interquartile range = 20.5-28.6) and hospital/healthcare organisation websites scoring lowest (median = 17.5; interquartile range = 13.5-21.5). Score differences were driven by differences in accountability (p = 0.001) - content scores were similar between groups (p = 0.25). Overall readability was low, with median Flesch-Kincaid Grade Level of 11th grade (interquartile range = 10th-12th grade). CONCLUSIONS: Our evaluation of popular websites about HLHS identifies multiple opportunities for improvement, including increasing accountability by disclosing authorship and citing sources, enhancing readability by providing material that is understandable to readers with the full spectrum of educational background, and providing information in languages besides English, all of which would enhance health equity.


Asunto(s)
Síndrome del Corazón Izquierdo Hipoplásico , Médicos , Humanos , Síndrome del Corazón Izquierdo Hipoplásico/cirugía
17.
J Surg Case Rep ; 2023(7): rjad372, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37416492

RESUMEN

Experience with durable biventricular assist devices (BiVADs) as a bridge to heart transplantation (HTx) is limited, particularly in women. A 41-year-old woman with biventricular failure complicated by cardiogenic shock underwent durable concurrent BiVAD implantation and was supported for 1212 days as a bridge to HTx. During BiVAD support, she experienced bacteremia (day 1030 of support), appropriately managed with intravenous antibiotics. She is alive and well, 1479 days from BiVAD implantation and 267 days from orthotopic HTx. Strategies contributing to successful prolonged support include concurrent BiVAD implantation, aggressive cardiac rehabilitation, diet management for weight loss and frequent interval surveillance.

19.
J Heart Lung Transplant ; 42(11): 1597-1607, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37307906

RESUMEN

BACKGROUND: Intra-aortic balloon pump (IABP) and Impella device utilization as a bridge to heart transplantation (HTx) have risen exponentially. We aimed to explore the influence of device selection on HTx outcomes, considering regional practice variation. METHODS: A retrospective longitudinal study was performed on a United Network for Organ Sharing (UNOS) registry dataset. We included adult patients listed for HTx between October 2018 and April 2022 as status 2, as justified by requiring IABP or Impella support. The primary end-point was successful bridging to HTx as status 2. RESULTS: Of 32,806 HTx during the study period, 4178 met inclusion criteria (Impella n = 650, IABP n = 3528). Waitlist mortality increased from a nadir of 16 (in 2019) to a peak of 36 (in 2022) per thousand status 2 listed patients. Impella annual use increased from 8% in 2019 to 19% in 2021. Compared to IABP, Impella patients demonstrated higher medical acuity and lower success rate of transplantation as status 2 (92.1% vs 88.9%, p < 0.001). The IABP:Impella utilization ratio varied widely between regions, ranging from 1.77 to 21.31, with high Impella use in Southern and Western states. However, this difference was not justified by medical acuity, regional transplant volume, or waitlist time and did not correlate with waitlist mortality. CONCLUSIONS: The shift in utilizing Impella as opposed to IABP did not improve waitlist outcomes. Our results suggest that clinical practice patterns beyond mere device selection determine successful bridging to HTx. There is a critical need for objective evidence to guide tMCS utilization and a paradigm shift in the UNOS allocation system to achieve equitable HTx practice across the United States.

20.
J Surg Case Rep ; 2023(6): rjad262, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37293331

RESUMEN

We present the case of a 60-year-old gentleman who was admitted with acute-on-chronic cardiogenic shock and was supported with axillary Impella 5.5® for 123 days prior to heart transplantation. Total length of temporary mechanical circulatory support (MCS) was 132 days, which included 9 days with an intra-aortic balloon pump prior to Impella. During support, the patient remained extubated, participated in regular ambulation and rehabilitation with physical therapy and had continuous monitoring of device positioning. He did not experience any vascular or septic events while on temporary MCS and had improved hemodynamics and renal function after Impella initiation. Post-transplantation course was uncomplicated, and he is doing well without evidence for allograft dysfunction over 581 days post-transplantation. To our knowledge, this is the longest Impella 5.5®-supported patient during the new United Network for Organ Sharing Heart Allocation era who was successfully bridged to heart transplantation with over 1-year follow-up.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...