Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
IEEE Trans Biomed Eng ; PP2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39008391

RESUMEN

OBJECTIVE: Pelvic fractures often require fixation through iliosacral joint, typically guided by fluoroscopy using an untracked C-arm device. However, this involves ionizing radiation exposure and potentially inaccurate screw placement. We introduce the Navigated Orthopaedic Fixations using Ultrasound System (NOFUSS), a radiation-free ultrasound (US)-based end-to-end system for providing real-time navigation for iliosacral screw (ISS) insertions. METHODS: We performed surgeries on 8 human cadaver specimens, inserting four ISSs per specimen to directly compare NOFUSS against conventional fluoroscopy. Six specimens yielded usable (marginal or adequate quality) US images. RESULTS: The median screw entry error, midpoint error, and angulations errors for NOFUSS were 8.4 mm, 7.0 mm, and 1.4◦, compared to 7.5 mm (p = 0.52), 5.7 mm (p = 0.30), and 4.4◦ (p = 0.001) for fluoroscopy respectively. NOFUSS resulted in 6 (50%) breaches, compared to 2 (16.7%) in fluoroscopy (p = 0.19). The median insertion time was 7m 37s and 12m 36s per screw for NOFUSS and fluoroscopy respectively (p = 0.002). The median radiation exposure during the fluoroscopic procedure was 2m 44s, (range: 1m 44s - 3m 18s), with no radiation required for NOFUSS. When considering the three cadavers that yielded only adequate-quality US images (12 screws), the measured entry errors were 3.6 mm and 8.1 mm respectively for NOFUSS and fluoroscopy (p = 0.06). CONCLUSION: NOFUSS achieved insertion accuracies on par with the conventionalfluoroscopicmethod,andreducedinsertiontimesandradiation exposure significantly. SIGNIFICANCE: This study demonstrated the feasibility of an automated, radiation-free, US-based surgical navigation system for ISS insertions.

2.
J Orthop Res ; 41(9): 1855-1862, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37249119

RESUMEN

Various femoral augmentation designs have been investigated over the past decade for the prevention of geriatric hip fracture. The experimental methods used to evaluate the efficacy of these augmentations have not been critically evaluated or compared in terms of biofidelity, robustness, or ease of application. Such parameters have significant relevance in characterizing future clinical success. In this study we aimed to use a scoping review to summarize the experimental studies that evaluate femoral augmentation approaches, and critically evaluate commonly applied protocols and identify areas for concordance with the clinical situation. We conducted a literature search targeting studies that used experimental test methods to evaluate femoral augmentation to prevent geriatric fragility fracture. A total of 25 studies met the eligibility criteria. The most commonly investigated augmentation to date is the injection of bone cement or another material that cured in situ, and a popular subsequent method for biomechanical evaluation was to load the augmented proximal femur until fracture in a sideways fall configuration. We noted limitations in the clinical relevance of sideways fall scenarios being modeled and large variance in the concordance of many of the studies identified. Our review brings about recommendations for enhancing the fidelity of experimental methods modeling clinical sideways falls, which include an improved representation of soft tissue effects, using outcome metrics beyond load-to-failure, and applying loads inertially. Effective augmentations are encouraging for their potential to reduce the burden of hip fracture; however, the likelihood of this success is only as strong as the methods used in their evaluation.


Asunto(s)
Fracturas de Cadera , Huesos Pélvicos , Humanos , Anciano , Fémur , Fracturas de Cadera/prevención & control , Fracturas de Cadera/cirugía , Cementos para Huesos/uso terapéutico , Fenómenos Biomecánicos
3.
Biomed Tech (Berl) ; 66(5): 529-536, 2021 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-34243227

RESUMEN

Hexapod-ring-fixators have a characteristic rattling sound during load changes due to play in the hexapod struts. This play is perceived as unpleasant by patients and can lead to frame instability. Using slotted-ball-instead of universal-joints for the ring-strut connection could potentially resolve this problem. The purpose of the study was to clarify if the use of slotted-ball-joints reduces play and also fracture gap movement. A hexapod-fixator with slotted-ball-joints and aluminum struts (Ball-Al) was compared to universal-joint-fixators with either aluminum (Uni Al) or steel struts (Uni Steel). Six fixator frames each were loaded in tension, compression, torsion, bending and shear and mechanical performance was analyzed in terms of movement, stiffness and play. The slotted-ball-joint fixator was the only system without measurable axial play (<0.01 mm) compared to Uni-Al (1.2 ± 0.1) mm and Uni-Steel (0.6 ± 0.2) mm (p≤0.001). In both shear directions the Uni-Al had the largest play (p≤0.014). The resulting axial fracture gap movements were similar for the two aluminum frames and up to 25% smaller for the steel frame, mainly due to the highest stiffness found for the Uni-Steel in all loading scenarios (p≤0.036). However, the Uni-Steel construct was also up to 29% (450 g) heavier and had fewer usable mounting holes. In conclusion, the slotted-ball-joints of the Ball-Al fixator reduced play and minimized shear movement in the fracture while maintaining low weight of the construct. The heavier and stiffer Uni-Steel fixator compensates for existing play with a higher overall stiffness.


Asunto(s)
Fijadores Externos , Fijación de Fractura , Fenómenos Biomecánicos , Diseño de Equipo , Humanos , Movimiento , Prótesis e Implantes
4.
Injury ; 50 Suppl 1: S10-S17, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31018903

RESUMEN

The concept of supporting fractured long bones externally with mechanical fixation has been evidentially applied for over 2000 years, and since been expanded on in the mid-19th century by percutaneous bone fixation. Surgical techniques, external fixator systems, and materials have made continued progress since. The benefits of traditional external fixation have been enhanced in recent years with the introduction of hexapod-style fixators, innovative configurations, and pin modifications, among other things. It is generally agreed upon that biomechanical testing of advancements in external fixation must be inclusive of transverse or torsional loading to simulate construct behaviour in realistic scenarios. Biomechanical studies indicate that hexapod-style fixators show comparable axial stiffness to Ilizarov-style systems and improved performance under torsional and transverse forces. The addition of configuration elements to fixators, inclusion of certain carbon fibre chemical compositions, and techniques intended to augment ring thickness have also been investigated, in hopes of increasing construct stiffness under loading. Novel external fixators attempt to broaden their applications by rethinking bone mounting mechanisms and either expanding on or simplifying the implementation of 3D bone segment transport for corrective osteotomy. Older and seemingly unconventional fixation techniques are being rediscovered and evolved further in order to increase patient comfort by improving everyday usability. The development of new pin coatings can potentially enhance the pin-bone interface while lowering infection rates typically expected at thicker soft tissue envelopes. Although complication, malunion, and nonunion rates have decreased over the past 50 years, the clinical results of external fixation today can still be optimized. Unsatisfactory healing in the lower extremities has especially been reported at locations such as the distal tibia; however, advancements such as osteoinductive growth hormone treatment may provide improved results. With the current progression of technology and digitization, it is only a matter of time before 'smart', partly-autonomous external fixation systems enter the market. This review article will provide a versatile overview of biomechanically proven fixator configurations and some carefully selected innovative systems and techniques that have emerged or been established in the past two decades.


Asunto(s)
Diseño de Equipo/instrumentación , Fijación de Fractura , Fracturas Óseas/cirugía , Extremidad Inferior/cirugía , Fenómenos Biomecánicos , Diseño de Equipo/historia , Diseño de Equipo/tendencias , Fijadores Externos/historia , Fijación de Fractura/historia , Fijación de Fractura/instrumentación , Fijación de Fractura/tendencias , Curación de Fractura , Fracturas Óseas/fisiopatología , Historia del Siglo XIX , Historia del Siglo XX , Historia del Siglo XXI , Humanos
5.
J Orthop Trauma ; 31(2): 71-77, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27861456

RESUMEN

OBJECTIVES: Active plates dynamize a fracture by elastic suspension of screw holes within the plate. We hypothesized that dynamic stabilization with active plates delivers stronger healing relative to standard compression plating. METHODS: Twelve sheep were randomized to receive either a standard compression plate (CP) or an active plate (ACTIVE) for stabilization of an anatomically reduced tibial osteotomy. In the CP group, absolute stabilization was pursued by interfragmentary compression with 6 cortical screws. In the ACTIVE group, dynamic stabilization after bony apposition was achieved with 6 elastically suspended locking screws. Fracture healing was analyzed weekly on radiographs. After sacrifice 9 weeks postsurgery, the torsional strength of healed tibiae and contralateral tibiae was measured. Finally, computed tomography was used to assess fracture patterns and healing modes. RESULTS: Healing in both groups included periosteal callus formation. ACTIVE specimens had almost 6 times more callus area by week 9 (P < 0.001) than CP specimens. ACTIVE specimens recovered on average 64% of their native strength by week 9, and were over twice as strong as CP specimens, which recovered 24% of their native strength (P = 0.008). Microcomputed tomography demonstrated that compression plating induced a combination of primary bone healing and gap healing. Active plating consistently stimulated biological bone healing by periosteal callus formation. CONCLUSIONS: Compared with compression plating, dynamic stabilization of simple fractures with active plates delivers significantly stronger healing.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Curación de Fractura , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Animales , Tornillos Óseos , Análisis de Falla de Equipo , Diseño de Prótesis , Ovinos , Fracturas de la Tibia/fisiopatología , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
6.
J Bone Joint Surg Am ; 98(6): 466-74, 2016 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-26984914

RESUMEN

BACKGROUND: Axial dynamization of fractures can promote healing, and overly stiff fixation can suppress healing. A novel technology, termed active plating, provides controlled axial dynamization by the elastic suspension of locking holes within the plate. This prospective, controlled animal study evaluated the effect of active plates on fracture-healing in an established ovine osteotomy model. We hypothesized that symmetric axial dynamization with active plates stimulates circumferential callus and delivers faster and stronger healing relative to standard locking plates. METHODS: Twelve sheep were randomly assigned to receive a standard locking plate or an active locking plate for stabilization of a 3-mm tibial osteotomy gap. The only difference between plates was that locking holes of active plates were elastically suspended, allowing up to 1.5 mm of axial motion at the fracture. Fracture-healing was analyzed weekly on radiographs. After sacrifice at nine weeks postoperatively, callus volume and distribution were assessed by computed tomography. Finally, to determine their strength, healed tibiae and contralateral tibiae were tested in torsion until failure. RESULTS: At each follow-up, the active locking plate group had more callus (p < 0.001) than the standard locking plate group. At postoperative week 6, all active locking plate group specimens had bridging callus at the three visible cortices. In standard locking plate group specimens, only 50% of these cortices had bridged. Computed tomography demonstrated that all active locking plate group specimens and one of the six standard locking plate group specimens had developed circumferential callus. Torsion tests after plate removal demonstrated that active locking plate group specimens recovered 81% of their native strength and were 399% stronger than standard locking plate group specimens (p < 0.001), which had recovered only 17% of their native strength. All active locking plate group specimens failed by spiral fracture outside the callus zone, but standard locking plate group specimens fractured through the osteotomy gap. CONCLUSIONS: Symmetric axial dynamization with active locking plates stimulates circumferential callus and yields faster and stronger healing than standard locking plates. CLINICAL RELEVANCE: The stimulatory effect of controlled motion on fracture-healing by active locking plates has the potential to reduce healing complications and to shorten the time to return to function.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas/instrumentación , Curación de Fractura/fisiología , Fracturas Conminutas/cirugía , Fracturas de la Tibia/cirugía , Animales , Fenómenos Biomecánicos , Modelos Animales de Enfermedad , Estudios Prospectivos , Diseño de Prótesis , Oveja Doméstica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...